Calcium Ion Selective Electrode Solutions - ISA

Cat. No.: I123795
AVAILABLE TO ORDER
GRADE & PURITY ISA
Storage
Room temperature
Shipped In
Normal
★
Size
Germany (EU)
USA*
Price
Qty
125ml
I123795-125ml
Made to order · 8–12 wks

€62.39

€81.48
Save €19.09 (23.43%)
500ml
I123795-500ml
Made to order · 8–12 wks

€138.75

€162.18
Save €23.43 (14.45%)
Enter a quantity for the sizes you want to add.
🧪
Why this grade

ISA for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Room temperature Ships Normal Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Specifications

Specifications & Purity
ISA
Storage
Room temperature
Shipped In
Normal

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDateItem
G1529038Certificate of AnalysisMar 08, 2023 I123795
FAQs and Articles
Solution Calculators
Reviews

Customer Reviews

Application Protocols

Below is a general protocol for Ca2+ ISE calibration and measurement. This is literature-based guidance and not specific to this item; adjust to the actual solutions provided in the kit and follow your electrode manufacturer’s instructions.

  • Item-specific facts (from Product Data)

    • Supplied components, concentrations, and exact steps: Not specified for this item; refer to CoA/Spec Sheet.
  • General Ca2+ ISE protocol (literature/general)

    1. Preparation
      • Equilibrate all solutions to measurement temperature. If provided, add the recommended volume of ISA to all standards and samples.
      • Condition the electrode in conditioning solution as specified by the electrode manufacturer.
    2. Calibration
      • Prepare at least two standards bracketing expected sample activity (e.g., 10^−3 and 10^−2 M Ca2+). Record potentials once stable.
      • Construct E vs. log a_Ca2+ plot; verify slope near the expected Nernstian value for Ca2+ at your temperature.
    3. Measurement
      • Rinse electrode with matrix-matched water, blot tip gently, immerse in sample+ISA, and record potential after stabilization.
      • For multiple samples, re-check one standard every 10–15 measurements to confirm drift is acceptable.
    4. Quality control
      • Include a mid-range check standard. If drift >2 mV or slope deviates significantly, recondition and recalibrate.
  • Notes

    • Avoid chelators (EDTA, citrate, phosphate) unless explicitly part of the method.
    • Report temperature, ISA composition, calibration points, slope, and intercept with results.
Biological Roles

Context: The product supports measurement of calcium ion activity; the following describes Ca2+ roles in biology (general knowledge), not product claims.

  • Calcium in biology (literature/general)

    • Signaling: Ca2+ serves as a ubiquitous second messenger regulating muscle contraction, neurotransmitter release, secretion, and gene expression. Transient changes in cytosolic Ca2+ are tightly controlled by channels, pumps, exchangers, and buffers.
    • Homeostasis: Organisms maintain extracellular and intracellular Ca2+ concentrations over orders of magnitude difference (mM extracellular vs. nM–µM cytosolic free Ca2+), involving bone mineral reservoirs and proteins such as calmodulin and troponin.
    • Binding and buffering: Proteins and small molecules (e.g., EGTA, BAPTA) chelate Ca2+ with diverse affinities, which is critical to consider because chelators reduce free Ca2+ activity and can bias potentiometric readings.
    • Speciation: In aqueous media, Ca2+ forms complexes with carbonate, sulfate, phosphate, and organic ligands; pH, ionic strength, and total inorganic carbon strongly influence free Ca2+ activity.
  • Analytical implication (general)

    • Ca2+ ISE measurements reflect activity, not total calcium. For biological samples, pretreatment (e.g., dilution, ionic strength adjustment, pH control) is often required to minimize matrix effects and complexation artifacts.
Buffer Applications

These solutions are not buffers per se; they are intended for electrode calibration/conditioning. However, buffer choice in sample preparation can affect Ca2+ ISE accuracy.

  • Item-specific facts (from Product Data)

    • Buffer identities or inclusion: Not specified for this item; refer to CoA/Spec Sheet.
  • General guidance (literature/general)

    • Avoid strong Ca2+-complexing buffers (e.g., phosphate, citrate, EDTA-containing systems) in standards and samples intended for free Ca2+ measurement. If buffering is necessary, choose low-complexation buffers and maintain identical buffer composition across standards and samples.
    • pH range: Keep pH away from ranges that promote CaCO3 or Ca(OH)2 precipitation (typically high pH) or that significantly change activity coefficients. Many Ca2+ ISE methods target near-neutral pH with ISA addition to stabilize ionic strength.
    • Preparation tips: Use CO2-minimized water for carbonate-sensitive measurements; equilibrate solutions to measurement temperature prior to calibration to maintain consistent activity coefficients.
  • Electrophoresis/cell culture

    • These solutions are not designed for electrophoresis or cell culture buffering. For those applications, use purpose-built buffers and, if measuring Ca2+, ensure matrix compatibility with potentiometric methods.
Green Alternatives

These are aqueous solutions used for electroanalytical measurements; environmental concerns mainly relate to salt load, preservatives, and packaging. No specific composition is provided for this item, so the following are general sustainability considerations.

  • Item-specific facts (from Product Data)

    • Composition and preservatives: Not specified for this item; refer to CoA/Spec Sheet.
  • General greener-practice options (literature/general)

    • Concentrates vs. ready-to-use: Using concentrates that are diluted on-site reduces packaging and transport impact; ensure calibration accuracy with Class A glassware.
    • Minimize waste: Prepare only the volume of working standards needed for the session. Collect spent solutions for appropriate disposal to limit salt discharge.
    • Preservative selection: Choose preservative-free or low-toxicity preservatives when microbial growth control is required, provided they do not complex Ca2+.
    • Reuse policy: Do not reuse calibration standards between sessions, but unopened stock standards can have extended shelf life; verify integrity periodically.

Comparison (general; not item-specific)

  • Ready-to-use aqueous standards

    • Pros: Convenience, reduced preparation error, high reproducibility
    • Cons: Higher shipping mass/volume, more packaging waste
  • Concentrated stock standards

    • Pros: Lower footprint, flexible preparation of ranges
    • Cons: Requires careful dilution, potential for operator error
Pharmaceutical Uses

No clinical or therapeutic claims apply. The following describes non-clinical, laboratory roles for Ca2+ ISE solutions in pharmaceutical and related QC settings (general guidance).

  • Item-specific facts (from Product Data)

    • Regulatory status or pharmacopeial compliance: Not specified for this item; refer to CoA/Spec Sheet.
  • General laboratory uses (literature/general)

    • Raw-material testing: Potentiometric determination of calcium in excipients (e.g., calcium salts) where rapid activity-based assessment is useful.
    • Process monitoring: Inline or at-line checks of Ca2+ activity in process waters or formulation steps, with matrix-matched calibration.
    • Method development: Establishing selectivity and robustness of Ca2+ measurements in complex matrices; assessing interference from Mg2+, Na+, K+, and formulation excipients.
    • Stability studies: Tracking changes in free Ca2+ activity in buffered systems where complexation or precipitation could occur over time.
  • Practical considerations

    • Documentation: Maintain calibration records (slope, intercept, temperature) with each assay series.
    • Cross-validation: Where specifications require total calcium, validate ISE results against a reference method (e.g., complexometric titration or ICP) to correlate activity-based readings with total content.
Physical Properties

Because this is a set of aqueous solutions (not a single compound), item-specific physicochemical constants are not applicable.

  • Item-specific facts (from Product Data)

    • Physical state/appearance: Not specified for this item; refer to CoA/Spec Sheet.
    • Density, pH, conductivity, refractive index, exact composition/concentrations: Not specified for this item; refer to CoA/Spec Sheet.
  • Literature/general values (for context; not item specifications)

    • Calibration standards for Ca2+ ISE commonly span 10^−1 to 10^−5 M Ca2+ to bracket sample activity; narrower ranges (e.g., 10^−2 to 10^−4 M) are often chosen for environmental or biological matrices.
    • Ionic strength adjusters (ISA) are often concentrated salt solutions (e.g., ~1–5 M of an inert electrolyte) used at a defined addition volume to each standard and sample to ensure constant ionic strength and improve linearity.
    • Conditioning/soak solutions are typically matched to the membrane chemistry (e.g., moderate Ca2+ concentration with background electrolyte) to equilibrate the membrane and enhance response stability.
    • Temperature dependence: Ca2+ ISE slopes are temperature-dependent via the Nernst term (59.16 mV/dec at 25 °C for a divalent ion ideal slope is ~29.58 mV/decade). Automated temperature compensation or constant-temperature measurements are recommended.
  • Practical notes (general)

    • Always prepare fresh working standards from higher-purity stock solutions using Class A glassware to minimize dilution error.
    • Use CO2-free water where carbonate complexation may bias free Ca2+ activity.
Quality and Grades

These solutions are intended for analytical potentiometry with calcium ion-selective electrodes. Performance depends on concentration accuracy, ionic strength control, and trace contamination management.

  • Item-specific facts (from Product Data)

    • Grade/purity: Not specified for this item; refer to CoA/Spec Sheet.
  • General guidance (literature/general)

    • Calibration standards: Analytical-grade standards are prepared gravimetrically or volumetrically from high-purity calcium salts (e.g., CaCl2) in high-resistivity water. Trace metal and carbonate control is important to preserve free Ca2+ activity.
    • Ionic strength adjuster (ISA): Consistency of ionic strength and composition across standards and samples is essential for Nernstian response and accurate activity calculations.
    • Traceability: Many laboratories require standards traceable to national metrology institutes or verified by titrimetry/ICP-OES; check the CoA for concentration uncertainty and traceability statements.
    • Low adsorption packaging: For dilute standards, low-adsorption plastics or borosilicate glass minimize analyte loss; leachables should be controlled.
    • Stabilizers/preservatives: If present, these should be disclosed on the CoA; they must not complex Ca2+ or alter ionic strength unpredictably. Not specified for this item; refer to CoA/Spec Sheet.
  • Practical QC tips

    • Verify electrode slope and intercept with a two- or three-point calibration before use.
    • Periodically check standards against a secondary source to detect drift or contamination.
Reaction and Applications

These solutions are designed for analytical potentiometry rather than synthetic reactions.

  • Item-specific facts (from Product Data)

    • Manufacturer applications: Not specified beyond product name; refer to CoA/Spec Sheet.
  • Analytical applications (literature/general)

    • Calibration of Ca2+ ion-selective electrodes (ISEs) for determining free calcium activity in water, soil extracts, process streams, and research samples.
    • Construction of calibration curves (E vs. log a_Ca2+) and verification of Nernstian slope for quality control. For a divalent ion, an ideal slope is approximately 29.58 mV/decade at 25 °C.
    • Electrode conditioning and storage using dedicated solutions to maintain membrane performance and shorten stabilization time.
    • Method development for interference mitigation using matched ionic strength, pH control, and, when appropriate, separate solution method (SSM) or fixed interference method (FIM) to evaluate selectivity coefficients.
    • Instrument qualification: Routine checks of electrode response time, drift, and repeatability using standardized solutions.
  • Practical tips (general)

    • Always calibrate bracketing the expected sample activity; avoid extrapolation.
    • Rinse electrode with matrix-matched water between measurements; blot dry (do not wipe the membrane) to avoid cross-contamination.
    • Maintain constant temperature; a 1–2 °C shift can noticeably change the slope and intercept.
Reaction Conditions

This section is interpreted for electroanalytical measurement conditions rather than chemical reactions.

  • Item-specific facts (from Product Data)

    • Specific concentrations/compositions: Not specified for this item; refer to CoA/Spec Sheet.
  • General measurement conditions (literature/general)

    • Calibration: Two- or three-point calibration using bracketing Ca2+ activities; ensure identical ISA addition to standards and samples. Target Nernstian slope near 29.6 mV/dec at 25 °C for Ca2+.
    • Temperature: Measure and calibrate at the same temperature; 20–25 °C is common. Record temperature for traceability.
    • Equilibration: Allow the electrode to condition in a medium appropriate for the membrane (per manufacturer) prior to first use; between measurements, rinse and blot.
    • Response time: Typically seconds to a couple of minutes depending on concentration step and membrane condition; wait for a stable potential (drift < ~0.2 mV/min) before recording.
    • Interferences: Evaluate Mg2+ and monovalent cations using separate solution or fixed interference methods to obtain selectivity coefficients if required by the method.
    • pH/Matrix: Maintain pH to avoid precipitation and complexation. Use CO2-minimized water and avoid chelators.
  • Data treatment

    • Plot E vs. log a_Ca2+; use linear regression to obtain slope/intercept. Apply activity corrections if needed or report in terms of concentration under constant ionic strength.
Safety and Handling

Safety depends on the exact composition of the solutions supplied. In the absence of specified hazards, adopt conservative aqueous-chemical handling practices.

  • Item-specific facts (from Product Data)

    • GHS classification, pictograms, H-statements, signal word: Not specified for this item; refer to SDS.
    • Storage: Room temperature; shipped under normal conditions.
  • General safe handling (literature/general; defer to SDS for this product)

    • PPE: Safety glasses, lab coat, and appropriate chemical-resistant gloves. Avoid contact with skin and eyes. Use in a well-ventilated area.
    • Incompatibilities: Avoid mixing with strong acids/bases or oxidizers unless the solutions are known to be compatible. Do not add sodium azide–containing reagents to copper/lead plumbing due to azide salt formation risk.
    • First aid: In case of skin/eye contact, rinse with water for at least 15 minutes; remove contaminated clothing. If ingested or inhaled, seek medical attention. Provide SDS to responders.
    • Spill response: For small aqueous spills, absorb with inert material and collect for disposal. Rinse area with water if appropriate and permitted by local regulations.
    • Special risks: Some ISE accessories may include chloride-rich or nitrate-based salts; manage corrosion potential on stainless steels and proper segregation of waste.
    • Disposal: Dispose according to local regulations for aqueous salt solutions; segregate any heavy-metal containing wastes if applicable.

Always consult the product’s SDS/CoA for definitive hazard and response information.

Solvent Selection

This product comprises aqueous analytical solutions; conventional solvent selection for organic reactions is not applicable.

  • Item-specific facts (from Product Data)

    • Matrix/solvent system: Not specified for this item; refer to CoA/Spec Sheet.
  • General guidance for Ca2+ ISE measurements (literature/general)

    • Medium: Deionized water is the standard solvent for Ca2+ standards and measurements. Maintain consistent ionic strength via ISA to minimize junction potentials and activity coefficient variability.
    • pH control: Ca2+ ISEs exhibit optimal performance in a pH range that avoids precipitation (e.g., CaCO3, Ca(OH)2) and suppresses complexation by chelators. If buffering is required, use buffers that do not complex Ca2+ strongly and keep their concentration constant across standards and samples.
    • Interferences: High concentrations of Na+, K+, Mg2+, and H+ can affect selectivity depending on the membrane formulation. Maintain consistent matrix to limit bias.
  • Comparisons (general)

    • Aqueous standards with ISA vs. neat water standards: ISA typically improves linearity and reproducibility, at the cost of introducing additional ions; ensure compatibility with your electrode and reference system.
    • Buffered vs. unbuffered media: Buffers improve pH stability but may change Ca2+ activity via complexation; select buffers with low Ca2+ binding.
Storage and Reconstitution

Storage and preparation requirements depend on the exact solutions included.

  • Item-specific facts (from Product Data)

    • Storage conditions: Room temperature
    • Shipping: Normal
    • Reconstitution: Not specified for this item; refer to CoA/Spec Sheet.
  • General guidance (literature/general)

    • Shelf life: Follow labeled expiry. Store tightly capped to prevent evaporation and CO2 absorption that could change carbonate content and pH.
    • Light/temperature: Protect from extreme temperatures and direct sunlight. Maintain consistent room temperature when possible to avoid crystallization of concentrated salts.
    • Cleanliness: Use clean, dedicated polypropylene or borosilicate glassware for dispensing. Do not return used aliquots to stock.
    • Microbial control: If solutions are preservative-free, minimize contamination by avoiding bottle-to-sample contact and using sterile techniques when necessary.
    • Reconstitution/dilution: If provided as concentrates, dilute with freshly prepared deionized water using Class A volumetrics. Mix thoroughly; verify concentration gravimetrically if high accuracy is required.
    • Electrode care: Store the Ca2+ ISE per the electrode manufacturer’s recommendations (often in a dedicated storage/conditioning solution). Do not store dry unless specified for that membrane type.

Always consult the product’s CoA and SDS for the authoritative storage and handling instructions specific to this item.

Structure and Identity

Brief overview: This product consists of prepared solutions intended for use with calcium ion-selective electrodes (Ca2+ ISE) in analytical potentiometry. It is not a single defined compound but an analytical solution set.

  • Item-specific facts (from Product Data)

    • Product type: Calcium Ion Selective Electrode Solutions (mixtures; not a single molecule)
    • Storage conditions: Room temperature
    • Shipping: Normal
    • Research use: For research use only
    • CAS, InChIKey, SMILES, Molecular formula, Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • General chemistry context (literature/general)

    • Typical components for Ca2+ ISE solution sets may include one or more of the following: calibration standards containing known activities of Ca2+ in aqueous matrix; an ionic strength adjuster (ISA) to maintain constant ionic strength and mitigate junction potential; a conditioning/soaking solution for the Ca2+ selective membrane; and a reference electrode filling solution if supplied for a double-junction setup.
    • Structural features: As aqueous solutions, these are mixtures of inorganic salts/acids/bases in water. No discrete “structure” applies as it would for a pure compound.
    • Measurement principle: The Ca2+ ISE develops a membrane potential proportional to the logarithm of Ca2+ activity according to the Nernst equation, enabling direct potentiometric quantification when used with appropriate standards and ionic strength control.
Synthetic Utility

Not typically applicable. Calcium Ion Selective Electrode Solutions are analytical standards/auxiliaries rather than reagents for chemical synthesis.

  • General note (literature/general)
    • While not used as reactants, accurate potentiometric quantification of Ca2+ can be valuable for monitoring processes where calcium salts precipitate or are consumed/produced, informing process adjustments.
    • For synthetic work requiring strict control of divalent cations (e.g., polymerization catalysts sensitive to alkaline earth metals), Ca2+ ISEs can be used to characterize and control aqueous feeds, but the solutions themselves are not synthetic building blocks.
Target Specificity

Not applicable. This product is not a biological affinity reagent (e.g., antibody or ligand) and has no species or epitope specificity.

  • Item-specific facts (from Product Data)

    • None specified beyond product type; refer to CoA/Spec Sheet if any selectivity data for the electrode/membrane are provided.
  • General note (literature/general)

    • In ISE work, "selectivity" refers to membrane selectivity for Ca2+ over interfering ions (e.g., Mg2+, Na+, K+, H+), quantified by potentiometric selectivity coefficients. Those parameters pertain to the electrode, not the calibration/conditioning solutions themselves.

Frequently Asked Questions

How should this product be stored?
Store at room temperature.
How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.