CHO-C-PEG2-C-CHO is a PEG-based PROTAC linker that can be used in the synthesis of PROTACs.
Specifications
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
This product requires cold chain shipping. Ground and other economy services are not available.
Names and Identifiers
Molecular Weight
190.19
Advanced Data
Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Solution Calculators
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Reviews
Customer Reviews
Application Protocols
No item-specific, validated application protocols are provided for this SKU. The following general workflows for aldehyde-based conjugation are literature-based and should be optimized per system.
Protocol A: Reductive amination to amine-bearing biomolecule
Dissolve linker in anhydrous DMSO (10–50 mM). Prepare biomolecule in 50 mM phosphate buffer, pH 7.4.
Mix to achieve 10–20% DMSO final; add linker to 1–5 mM and biomolecule to provide 2–10× amine molar excess relative to aldehyde.
Incubate 1–2 h at RT. Add NaCNBH3 or picoline borane to 10–20 mM. React 2–4 h.
Quench unreacted aldehydes with 50 mM hydroxylamine, 15–30 min. Desalt by SEC or dialysis.
Combine aldehyde linker (1–5 mM) and alkoxyamine partner (5–10 mM). Incubate 1–4 h at RT.
Optional: Reduce oxime to secondary amine with borane–pyridine or NaBH3CN if permanent linkage desired.
Quality control
Assess coupling by LC–MS or, for proteins, by intact MS and SDS-PAGE. Quantify residual carbonyls using DNPH or hydroxylamine assays.
Note: Adjust concentrations and times to balance solubility, biomolecule stability, and desired crosslink density.
Biological Roles
This product is a synthetic bifunctional linker and does not have inherent biological roles as a metabolite or natural product.
General/literature context for aldehyde-terminated PEG linkers (not item-specific):
Bioconjugation utility: Terminal aldehydes undergo Schiff base, oxime, and hydrazone formation with lysine ε-amines or hydrazide-modified biomolecules, enabling site-accessible coupling under mild, aqueous conditions.
Spacer effects: A short PEG2 segment imparts hydrophilicity and conformational flexibility while maintaining compact spacing between conjugated partners—often beneficial for reducing steric hindrance and improving aqueous dispersibility relative to hydrocarbon linkers.
Protein and surface immobilization: Aldehyde-functional surfaces created with such linkers permit reversible imine capture and subsequent stabilization via reduction, aiding biosensor assembly, enzyme immobilization, and affinity purification matrices.
Glycoconjugation: Reaction with hydrazide/alkoxyamine tags selectively targets aldehydes generated on oxidized glycans (periodate oxidation), facilitating glycan-directed labeling.
Restrictions:
No therapeutic or clinical claims are made. Use is restricted to research settings.
Note:
The reactivity of aldehydes toward biological nucleophiles necessitates careful control of exposure and quenching in cell- or protein-facing contexts. Stability can be enhanced post-coupling by reductive fixation to minimize imine hydrolysis.
Buffer Applications
While this product is not a buffering agent, buffer choice critically affects aldehyde-based conjugation performance. The guidance below reflects general/literature practice and is not item-specific.
Recommended buffer systems for aldehyde coupling:
Phosphate buffer (PBS without amines), pH 6.0–7.4: Compatible with Schiff base formation and subsequent reductive amination. Avoid Tris or glycine, which contain primary amines.
Acetate or MES buffers, pH 4.5–6.0: Favor oxime and hydrazone formation; adding aniline (10–100 mM) can catalyze and accelerate ligation.
Carbonyl-free buffers: Ensure the buffer does not contain competing carbonyl-reactive components (amines, hydrazides) unless intentionally used as catalysts.
Practical tips:
Co-solvent: Include 10–30% v/v DMSO or acetonitrile if needed to solubilize the linker while maintaining biomolecule stability.
Concentration ranges: Typical aldehyde concentrations for bioconjugation fall between 0.1–10 mM, with biomolecule amine partners at 1–20× molar excess depending on desired crosslinking density (optimize empirically).
Quenching: After coupling, quench unreacted aldehydes with hydroxylamine (10–50 mM) or ethanolamine (careful if protein amines are present) to cap residual reactivity.
Verification:
Monitor conjugation in real time by UV–Vis labeling stoichiometry (if chromophore present), mass spectrometry, or SDS-PAGE mobility shifts. For small-molecule assemblies, use LC–MS or derivatization assays (DNPH/hydroxylamine).
Green Alternatives
Assessment here compares typical PEG dialdehydes and common crosslinkers from a green chemistry perspective. These points are general and not item-specific.
Considerations for CHO-terminated PEG2 linkers (general):
Advantages: Low volatility (reduced inhalation exposure vs small aldehydes like glutaraldehyde); PEG backbone can improve aqueous handling, potentially lowering need for harmful organic solvents. Enables chemoselective ligations that proceed at ambient temperature and near-neutral pH.
Concerns: Aldehyde functionalities are reactive electrophiles; waste streams may contain residual reactive carbonyls and borohydrides if reductive amination is used.
Potential greener choices and tradeoffs:
Enzymatic ligation (e.g., microbial transglutaminase) versus chemical aldehyde crosslinking: avoids reactive carbonyls but requires specific peptide motifs and biocatalyst sourcing.
Click chemistry (azide–alkyne, SPAAC) linkers: often superior selectivity and benign byproducts; requires pre-installation of azide/alkyne groups and may involve copper catalysts (for CuAAC) with associated disposal.
Oxime/hydrazone ligation in water with aniline catalysts: avoids strong reducing agents; reversible unless subsequently reduced—balance between reversibility and stability.
Process improvements (greener practice):
Use water or aqueous-organic mixtures with minimal organic solvent loading consistent with solubility needs.
Replace sodium cyanoborohydride with picoline borane or hydrogenation where compatible.
Employ catalytic aniline at low loadings and recover by dialysis or chromatography.
Neutralize residual aldehydes post-reaction via oxime quench to reduce toxicity in waste streams.
Pharmaceutical Uses
No pharmacopeial status or excipient role is provided for this item; consult the CoA/Spec Sheet for any regulatory annotations. The following describes general R&D uses only.
General R&D and process development context (not item-specific):
Conjugation/process reagent: Bifunctional PEG dialdehydes are used in development to crosslink or functionalize biomolecules and polymers under mild conditions, enabling prototype ADC linkers, polymer–protein conjugates, and hydrogel formation for drug delivery research.
Spacer engineering: Short PEG2 spacers adjust hydrophilicity and spatial separation in conjugates, which can inform structure–property relationships during pre-formulation screening.
Immobilization for analytics: Creation of aldehyde-terminated surfaces for assay development (e.g., immobilizing capture ligands on sensor chips or plates) to screen binding interactions.
Caveats:
Not for human or veterinary use. No clinical/therapeutic claims are made.
Any move toward GMP or clinical development would require fully qualified grades, impurity controls, residual solvent limits, and validated methods; such information is Not specified for this item; refer to CoA/Spec Sheet.
Process considerations:
Residual aldehyde must be controlled in final materials; implement robust quench and clearance steps.
Selection of reducing agents (e.g., picoline borane over cyanoborohydride) may simplify impurity control in pharmaceutical settings.
Physical Properties
Item-specific physical constants have not been supplied for this SKU. Do not treat the following as specifications; consult the CoA/Spec Sheet for definitive values.
Item-specific (from Product Data):
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
General/literature expectations for short PEG dialdehydes (not item-specific):
Physical state: typically low-melting solids, semi-solids, or viscous oils depending on exact spacer and purity.
Solubility: good in polar aprotic solvents (DMSO, DMF, acetonitrile). Many short PEG derivatives show partial to good solubility in water, alcohols, and acetone; terminal aldehydes may hydrate in water.
Density/refractive index: comparable to short PEG oligomers; refractive index typically higher than water for liquid forms.
Sensitivity: aldehydes can oxidize to acids and form acetals/hemiacetals with alcohols; hydrate in aqueous media; may oligomerize under acidic/basic conditions.
Practical guidance (general):
Prepare solutions freshly in anhydrous solvents to minimize hydrate/acetal formation.
Verify concentration by quantitative NMR or derivatization assays when precise stoichiometry is critical.
For exact BP/MP, logP, pKa, density, and refractive index of this item: Not specified for this item; refer to CoA/Spec Sheet.
Quality and Grades
From Product Data (item-specific):
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Guidance for interpreting grade (general, not item-specific):
Research grade: Intended for laboratory R&D only; impurity profiles tailored to synthetic/analytical needs rather than clinical use.
Purity descriptors (e.g., ≥95%, HPLC grade, LC–MS grade): Indicate assay methodology and impurity limits relevant to application. For reactive linkers, functional end-group integrity can be as important as bulk purity.
Stabilizers: Not specified for this item; refer to CoA/Spec Sheet. Some aldehyde reagents are supplied without stabilizers; others may be protected as acetals and deprotected prior to use.
End-group functionality (titration or derivatization test for –CHO content).
Residual solvents, water (Karl Fischer), and inorganic impurities (ICP) if critical to your application.
Identity confirmation (NMR, HRMS) matched to the CAS and supplier’s structural depiction.
Practical tip:
For bioconjugation, prioritize lots with high active aldehyde content and low water to minimize hydrate formation and ensure reproducible coupling kinetics.
Reaction and Applications
This reagent class serves as a bifunctional aldehyde linker enabling chemoselective conjugation and polymer/surface modification.
Schiff base formation with primary amines to give imines, typically followed by reductive amination (NaCNBH3 or picoline borane) to yield stable secondary amines. Useful for crosslinking proteins/peptides to amine-functionalized surfaces or polymers.
Oxime ligation with alkoxyamines (–ONH2) and hydrazone formation with hydrazides (–CONHNH2). Oximes/hydrazones can be accelerated by aniline catalysts and tuned by pH (oxime/hydrazone optimal pH ~4.5–6.0; aniline catalysis broadens range).
End-group modification of polymers: Installing dialdehyde ends on PEG-like scaffolds allows subsequent diversification (Wittig, Horner–Wadsworth–Emmons, Grignard addition to each aldehyde under controlled conditions).
Surface chemistry: Creating aldehyde-presenting monolayers/films for immobilizing biomolecules via their lysine residues or hydrazide-tagged glycans.
Dynamic covalent chemistry: Reversible imine/acylhydrazone networks for self-healing materials or stimuli-responsive assemblies.
Practical tips (general):
Minimize adventitious water before coupling; aldehyde hydration reduces effective concentration.
For bioconjugation, avoid amine-containing buffers (Tris, glycine). Use phosphate, acetate, or MES buffers instead.
Verify coupling completion by monitoring disappearance of aldehydic 1H NMR signal (~9–10 ppm) or by derivatization assays (e.g., DNPH, hydroxylamine titration).
After imine formation, immediate reductive stabilization minimizes hydrolysis and scrambling.
Reaction Conditions
The following are literature/general conditions for aldehyde coupling chemistry and are not item-specific specifications.
Schiff base formation and reductive amination:
Solvent: Aqueous phosphate buffer (50–100 mM, pH 6.5–7.5) with 10–30% DMSO or ACN if needed.
Reagents: Primary amine partner (1–20 equiv relative to aldehyde). Reductant: NaCNBH3 (5–50 mM) or picoline borane (safer alternative) added after imine formation.
Temperature/time: RT, 1–16 h. Reduction typically complete within 1–4 h post-addition.
Oxime/hydrazone ligation:
Solvent: Acetate or MES buffer, pH 4.5–6.0, optionally 10–20% organic co-solvent.
Catalyst: Aniline (10–100 mM) or p-anisidine to accelerate. Hydroxylamine/hydrazide partner at 1–10 equiv.
Temperature/time: RT, 0.5–6 h to substantial conversion; can be driven to completion overnight.
Carbon–carbon bond-forming reactions (on small-molecule scale):
Wittig/HWE: Anhydrous THF/DMF, 0–25°C, base as appropriate (e.g., NaH for HWE ester phosphonates). Strictly exclude water.
Organometallic additions: Anhydrous ether/THF at −78 to 0°C. Quench carefully to avoid over-addition or side reactions.
Workup/purification:
For bioconjugates, remove catalysts/reagents by dialysis or desalting columns; quench residual aldehyde with hydroxylamine (10–50 mM).
For small molecules, use silica gel chromatography; note that aldehydes can tail—pre-derivatization or addition of 0.1–1% Et3N to eluent may help.
Monitoring:
Aldehyde disappearance at 1H NMR 9–10 ppm; LC–MS for mass shifts; colorimetric DNPH assays for residual carbonyl content.
Safety and Handling
Authoritative safety information must be taken from the product SDS. The following are general best practices for aldehyde-terminated PEG linkers.
From Product Data (item-specific):
GHS Classification: Not specified for this item; refer to SDS.
Signal Word: Not specified for this item; refer to SDS.
H-Statements/Pictograms: Not specified for this item; refer to SDS.
Storage: Store at -20°C. Shipped cold (ice chest + ice pads).
General safety considerations (literature/general):
Hazards: Aldehydes are electrophiles and can be irritating to skin, eyes, and respiratory tract; sensitization is possible. PEG backbones are generally of low acute toxicity, but terminal –CHO groups confer reactivity.
PPE: Lab coat, nitrile gloves, safety glasses. Use in a fume hood to avoid inhalation of vapors/aerosols when preparing solutions.
Incompatibilities: Strong oxidizers (risk of over-oxidation to acids), strong bases/acids (can promote aldol, acetalization, or decomposition), nucleophilic amines (unintended imine formation), and reducing agents when reductive amination is not desired.
Handling: Work under dry conditions; aldehydes may form hydrates/acetal byproducts in protic media. Use anhydrous solvents and amber containers if light sensitivity is suspected.
First aid (overview; defer to SDS): Eye/skin contact—rinse with water for 15 minutes; remove contaminated clothing. Inhalation—move to fresh air. Ingestion—rinse mouth, seek medical attention. Provide SDS to responders.
Waste: Collect aldehyde-containing waste separately; quench reactivity by controlled conversion to oxime/hydrazone where appropriate, then dispose per institutional and local regulations.
Solvent Selection
Item-specific solvent compatibility is not provided; consult the CoA/SDS. The following guidance reflects literature behavior of short PEG dialdehydes.
General solvent behavior (literature/general):
Polarity: Moderately polar due to PEG ether oxygens; terminal aldehydes add polarity and reactivity.
Likely miscibility: High solubility in polar aprotic solvents (DMSO, DMF, acetonitrile). Often soluble in alcohols and acetone; variable solubility in water depending on spacer and exact structure.
Aqueous buffers: Aldehydes hydrate in water and may slowly undergo side reactions; use immediately after dissolution. Avoid buffers containing primary amines (Tris, glycine) during conjugation.
Selection tips by application:
Bioconjugation (Schiff base/oxime/hydrazone): Use aqueous buffer mixed with an organic co-solvent (10–50% v/v DMSO or ACN) to maintain solubility while controlling reaction pH.
Reductive amination: Polar aprotic solvents or mixed aqueous systems with sodium cyanoborohydride or picoline borane; exclude excess water to limit hydrate formation.
Surface/linker assembly: Use anhydrous DMF or DCM/DMF blends when immobilizing on amine-functionalized substrates via imines followed by reduction.
Comparison (general):
Versus glutaraldehyde: PEG dialdehydes are less volatile, often less odorous, and can improve spacer hydrophilicity; glutaraldehyde offers rapid crosslinking but is more hazardous and less selective.
Versus longer PEGn dialdehydes: PEG2 offers shorter reach and potentially higher rigidity; longer PEGs improve water solubility but may reduce control over spacing.
Storage and Reconstitution
From Product Data (item-specific):
Storage Conditions: Store at -20°C.
Shipped In: Ice chest + Ice pads.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
General handling and reconstitution guidance (not item-specific):
Moisture sensitivity: Aldehydes can hydrate and form acetals; handle quickly under dry conditions. Allow container to equilibrate to room temperature before opening to minimize condensation.
Stock solutions: Prepare fresh stocks in anhydrous DMSO or DMF (e.g., 10–100 mM). Filter through 0.2 µm PTFE if particulate is present.
Aliquoting: Dispense single-use aliquots and refreeze at −20°C or below to avoid repeated freeze–thaw. Protect from light if the supplier indicates photosensitivity.
Aqueous use: If dissolution in buffer is required, mix immediately before use and proceed with conjugation promptly to limit hydrate/acetal formation. Avoid amine-containing buffers unless intended for imine formation.
Stability: Exact shelf life and stability-indicating parameters are Not specified for this item; refer to CoA/Spec Sheet. Monitor by 1H NMR (aldehydic signal) or LC–MS to confirm integrity over time.
Disposal:
Quench residual aldehyde in solutions (e.g., hydroxylamine) before disposal. Follow institutional and local regulations for organic chemical waste.
Structure and Identity
Item-specific identifiers provided in Product Data are limited for this entry; definitive identity parameters should be confirmed against the item’s CoA/Spec Sheet.
From Product Data (item-specific):
CAS: 92351-72-9
Storage: Store at -20°C
Shipped in: Ice chest + Ice pads
Research use: For research use only
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
General/literature description of the name (not item-specific):
“CHO-C-PEG2-C-CHO” typically denotes a short polyethylene glycol linker (approx. two oxyethylene units, “PEG2”) terminated at both ends with aldehyde (–CHO) functions, often separated by short methylene spacers (“–CH2–”, denoted by “C”). This class belongs to bifunctional PEG dialdehydes used as crosslinkers and end-group modifiers.
Key functional groups: two terminal aldehydes; internal ether oxygens of PEG; possible methylene spacers between PEG and aldehyde carbons.
2D structural features (literature-style, descriptive):
Linear chain comprising –O–CH2–CH2–O–CH2–CH2– segments (PEG2) with terminal –CH2–CHO (or analogous) moieties. Planar sp2 carbonyl carbons at each terminus; remainder is flexible, rotatable C–C and C–O bonds.
Important note:
Exact atom count, formula, and mass depend on the specific spacer pattern used by the manufacturer; consult the CoA for the definitive structure corresponding to CAS 92351-72-9.
Synthetic Utility
As a bifunctional aldehyde with a short PEG spacer, this reagent class is versatile for stepwise or convergent assembly in solution or on surfaces. The points below are general/literature and not item-specific.
Transformations enabled:
Dual imine formation followed by reduction to install two secondary amines at defined spacing—useful for bridging diamines or grafting onto polyamines.
Oxime/hydrazone ligation to introduce hydroxylamine/hydrazide-bearing motifs, optionally followed by reduction to stable C–N bonds.
Carbonyl chemistry: Wittig/Horner–Wadsworth–Emmons olefination, cyanohydrin formation, nucleophilic addition (e.g., organometallics) at each aldehyde under anhydrous conditions.
Protective chemistry: Temporary acetal formation to mask one or both aldehydes for orthogonal, sequential functionalization.
Polymer end-group modification: Converting dialdehyde into diacetal or diol derivatives or diversifying termini for block-copolymer synthesis and surface grafting.
Strategic use:
The PEG2 segment imparts hydrophilicity and flexibility, improving compatibility with aqueous media while maintaining compact spacing—valuable in designing crosslink length and solvation.
Orthogonal assembly: One end can be engaged (e.g., hydrazone to a hydrazide surface), leaving the other aldehyde for subsequent coupling to an amine-bearing partner.
Tips:
Control chemoselectivity using protecting groups or kinetic preference (e.g., preforming an oxime at mildly acidic pH, then reductive amination on the remaining aldehyde at neutral pH).
Target Specificity
Not applicable. This product is a small-molecule linker, not a biological affinity reagent. No antigen/epitope, clone, isotype, or species reactivity applies. For conjugation targets and selectivity, refer to the Reaction & Applications and Synthetic Utility sections.
Frequently Asked Questions
How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 92351-72-9, the molecular formula is C8H14O5, and the molecular weight is 190.19 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.