DBCO PEG Amine, DBCO-PEG-NH2 - MW 5000 Da

Cat. No.: D163521
AVAILABLE TO ORDER
GRADE & PURITY MW 5000 Da
Storage
Room temperature
Shipped In
Normal
★
Size
Germany (EU)
USA*
Price
Qty
20mg
D163521-20mg
Made to order · 8–12 wks

€1,027.32

€1,199.13
Save €171.81 (14.33%)
Enter a quantity for the sizes you want to add.

Specifications

Specifications & Purity
MW 5000 Da
Storage
Room temperature
Shipped In
Normal

Advanced Data

Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
FAQs and Articles
Solution Calculators
Reviews

Customer Reviews

Application Protocols

Note: No item-specific, tested protocols are provided in the Product Data. The following are general literature-style procedures to guide use. Adjust to your system.

A. Installing DBCO-PEG-NH2 onto a carboxylated protein (EDC/sulfo-NHS)

  • Buffer exchange protein into 50 mM MES, pH 5.8 (no amines). Add EDC (5–10 mM) and sulfo-NHS (10–25 mM) to activate for 15–30 min at room temp.
  • Adjust to pH 7.8–8.2 with 10× HEPES or phosphate. Add DBCO-PEG-NH2 at 2–10 equiv per estimated accessible carboxyl group or 3–10 equiv per protein lysine target; react 1–2 h at RT (or 4 °C overnight).
  • Quench with 20 mM Tris or 50 mM ethanolamine. Purify by desalting column (e.g., 7 kDa MWCO). Verify DBCO incorporation by UV or MS.

B. SPAAC with an azide-labeled partner

  • Prepare conjugation buffer: PBS, pH 7.4 (no sodium azide). Combine DBCO-bearing material with azide partner at 1.1–2.0 equiv DBCO per azide site, final concentration 10–100 µM (biomolecules).
  • Incubate 30–120 min at 20–37 °C with gentle mixing. Optional: include 5–10% DMSO to aid solubility. Monitor by MS or SEC.
  • Purify by SEC, dialysis, or spin filtration.

C. Small-molecule amide coupling (HATU)

  • Dissolve carboxylic acid (1.0 equiv) and DBCO-PEG-NH2 (1.2–1.5 equiv) in anhydrous DMF (0.05–0.2 M). Cool to 0 °C; add HATU (1.2–1.5 equiv) and DIPEA (2–4 equiv). Stir 1–3 h at 0–25 °C.
  • Quench with water, extract with EtOAc, wash, dry, and purify by chromatography.

General tips

  • Avoid Tris/glycine buffers during NHS coupling; avoid sodium azide during SPAAC.
  • Protect from strong light; store and handle under dry conditions for best performance.
Biological Roles

Item-specific biological roles

  • None specified; this product is a synthetic reagent for research use only.

General context (literature)

  • Bioorthogonality: DBCO–azide SPAAC proceeds without interfering with native biological functional groups, enabling labeling in complex media and on living systems (when cell-compatible conditions are used).
  • PEG effects: The PEG spacer reduces nonspecific binding, improves aqueous dispersibility, and can increase hydrodynamic radius, thereby enhancing accessibility of the DBCO group to azide partners on biomolecules or surfaces.
  • Azide introduction: Azido groups are often incorporated metabolically (e.g., azido sugars into glycans) or via synthetic modification (NHS–azide reagents) to create SPAAC-ready targets.
  • Applications in biochemical workflows: Affinity tagging, imaging probe attachment, pull-down assays, creation of triazole-stabilized conjugates, and distance-controlled multivalent displays using PEG spacers.

Limitations/considerations

  • Reaction selectivity relies on the absence of competing azides; buffers preserved with sodium azide will consume DBCO.
  • The amine terminus can engage in side reactions with electrophiles in biological matrices; protect or block as needed if only the DBCO is intended to react.

Note

  • No therapeutic/clinical role is claimed. Use is restricted to laboratory research, assay development, and materials preparation.
Buffer Applications

Applicability

  • This reagent is not a buffering agent. However, buffer choice is critical for its two primary uses: (1) amide coupling via the terminal amine and (2) SPAAC via the DBCO.

Recommended buffer systems (general/literature)

  • NHS/EDC coupling to carboxyls:
    • Buffer: 50–100 mM phosphate or HEPES, pH 7.5–8.5; alternatively 50–100 mM bicarbonate, pH ~8.3 for direct NHS reactions.
    • Avoid: Primary amine-containing buffers (Tris, glycine) during coupling as they compete with the reagent.
  • SPAAC with azides:
    • Buffer: PBS or HEPES, pH 6.5–8.0. Ionic strength (100–300 mM NaCl) can reduce nonspecific interactions without impairing click kinetics.
    • Compatibility: Catalyst-free; Mg2+/Ca2+ salts, mild detergents (0.01–0.1% Tween-20), and 0–20% DMSO or DMF cosolvent are generally tolerated by SPAAC.

Practical buffer tips

  • Degassing is not required for SPAAC. Maintain neutral pH to preserve protein integrity.
  • For sensitive proteins, include 0.5–2 mM EDTA only if metal chelation is needed; EDTA is compatible with SPAAC but avoid sodium azide preservatives.
  • After coupling, remove excess reagent by desalting columns (e.g., 7–10 kDa MWCO for proteins) or dialysis into storage buffer.
Green Alternatives

Context

  • DBCO-PEG-NH2 is a high-value bioconjugation reagent used in small amounts. While not a bulk solvent, greener choices can be made in solvent and reaction design.

Greener design choices (general)

  • Copper-free SPAAC vs CuAAC: SPAAC avoids copper catalysts and associated chelators, reducing metal waste and cytotoxicity in biological workflows.
  • Aqueous media: Favor buffered aqueous systems (PBS, HEPES) with minimal organic cosolvent for SPAAC steps when solubility permits.
  • Safer coupling agents: For amide formation, consider water-soluble carbodiimides (EDC) with NHS over uronium/PHOS coupling reagents that can be more hazardous.

Alternative click handles (comparison; literature)

  • BCN/DIBAC vs DBCO: Similar copper-free reactivity; BCN variants can offer different solubility and stability profiles. Choice may depend on payload hydrophobicity and protein compatibility.
  • Tetrazine–TCO (iEDDA): Faster kinetics in water and no catalyst; however, tetrazines can be air/light sensitive and less robust than DBCO in storage.

Mini-comparison table (general)

  • SPAAC (DBCO): Catalyst-free, moderate–fast rates, robust storage; sometimes needs organic cosolvent.
  • SPAAC (BCN): Catalyst-free, good aqueous compatibility for some analogs; slightly different kinetics.
  • iEDDA (TCO–tetrazine): Very fast, fully aqueous; reagents can be less stable and more costly.

Operational tips

  • Use high-atom economy linkers and minimize protecting groups.
  • Recover and appropriately dispose of DMF/DMSO; consider MeCN or greener solvents if compatible.
Pharmaceutical Uses

Item-specific regulatory/compendial status

  • Not specified for this item; refer to CoA/Spec Sheet. Supplied for research use only.

General roles in pharmaceutical R&D (literature)

  • Bioconjugation scaffold: DBCO-PEG-NH2 is used to introduce a SPAAC-ready handle onto drug candidates, peptides, proteins, polymers, and nanoparticles via amide bond formation. This enables modular attachment of azide-bearing payloads (imaging labels, affinity tags, solubilizers).
  • Process development: Evaluating linker length (PEG units) to tune PK/PD surrogates, sterics, and hydrodynamics in preclinical materials.
  • Analytical conjugation standards: Preparation of model conjugates for method development (HIC, SEC, CE-SDS, LC–MS) without introducing copper.
  • Device/surface modification: Functionalization of diagnostic surfaces and delivery devices to immobilize azide-containing capture ligands.

Manufacturing considerations (general)

  • Reagent quality: Low endotoxin/bioburden and defined PEG polydispersity may be desired depending on application; verify with supplier documentation.
  • Residuals: Removal of DMF/DMSO and coupling byproducts via diafiltration or chromatography is standard.
  • Stability: Protect from light and store as directed. Validate shelf life and reactivity in your process.

Note

  • No therapeutic claims are made. This product is not an API or excipient as supplied; it is a research reagent used to assemble conjugates in development settings.
Physical Properties

Item-specific data (from Product Data)

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • Other specs (MP/BP, density, solubility, pKa, logP, UV cutoff, water/peroxide/metal limits): Not specified for this item; refer to CoA/Spec Sheet.

General/literature guidance for DBCO–PEG–NH2 class

  • Physical form: Typically off-white solid or viscous syrup depending on PEG length (short PEGs often waxy solids; longer PEGs viscous oils).
  • Solubility profile: PEG imparts good solubility in polar aprotic solvents (DMSO, DMF, NMP, acetonitrile) and mixed aqueous/organic systems. Many DBCO–PEG–NH2 variants are soluble to partially soluble in water; solubility improves with longer PEG.
  • pKa (amine, literature): Primary aliphatic amine conjugate acid pKa typically ~9–10; effective nucleophilicity for amide coupling near pH 7.5–8.5.
  • Stability: DBCO strained alkyne is stable under neutral conditions but can undergo slow reaction with azides and certain nucleophiles; light and heat can accelerate side reactions. PEG and amine are generally robust.
  • Hygroscopicity: PEG chains can be mildly hygroscopic; handle under dry conditions for moisture-sensitive couplings.

Practical handling implications (general)

  • Avoid prolonged exposure to strong acids/bases and oxidants.
  • For accurate solubility and extinction coefficients of a specific lot/length, consult the CoA/Spec Sheet.
Quality and Grades

Item-specific grade/purity (from Product Data)

  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.

How to interpret quality for this reagent class (general guidance)

  • Functional integrity: For DBCO–PEG–NH2, the key quality attributes are (a) DBCO functionality (active strained alkyne, low polymeric or oxidized byproducts), (b) PEG length distribution (polydispersity), and (c) free amine content (titrable amine).
  • Typical assays (literature/industry): NMR to confirm DBCO aromatic and alkyne signals; LC–MS or MALDI to assess MW distribution; HPLC/UPLC purity; amine value (TNBS or NMR integration); residual solvents and water by KF.
  • Stabilizers: These materials are commonly supplied without stabilizers; if any stabilizer or salt form is used, it will be disclosed on the CoA. Implications: stabilizers can affect reactivity in conjugation; check documentation before critical applications.
  • Absorbance/UV: DBCO chromophore exhibits UV absorbance in the near-UV; if low-UV background is required (e.g., analytical methods), verify with the CoA.
  • Trace metals/peroxides: Not specified for this item; refer to CoA/Spec Sheet. For sensitive bioconjugations, low metal content may be desirable.

Practical recommendations

  • Request a CoA with exact PEG length distribution and purity for method validation.
  • For regulated workflows, qualify a lot by in-house test coupling to an NHS ester and an azide model substrate to confirm performance.
Reaction and Applications

Core reactions (literature)

  • Copper-free click (SPAAC): Strained alkyne (DBCO) reacts rapidly and selectively with organic azides to form triazoles without Cu(I) catalysis. Effective in live-cell compatible buffers and on biomacromolecules.
  • Amide formation: Terminal primary amine enables conjugation to carboxylic acids via NHS esters, carbodiimide coupling (EDC/NHS), or activated carbonates.

Representative applications (general)

  • Two-step bioconjugation: Install DBCO-PEG-NH2 onto carboxyl-bearing biomolecules (proteins, polymers, nanoparticles), then click with azide-bearing probes, polymers, or payloads.
  • Surface functionalization: Introduce DBCO handles on carboxylated surfaces (COOH-terminated SAMs, carboxylated polystyrene, silica) for subsequent azide immobilization.
  • Polymer chemistry: Synthesize block copolymers or networks via SPAAC, controlling spacing with PEG length to reduce steric hindrance and improve hydration.
  • ADC/biomaterial research: Use the amine to couple to activated linkers or spacers; employ DBCO for site-selective labeling of azide-tagged residues.

Practical tips (general)

  • Keep reagents and glassware free of adventitious azides (e.g., from NaN3-preserved buffers) unless intended for reaction.
  • For NHS coupling, maintain pH 7.5–8.5; minimize primary amine buffers (Tris) during coupling to avoid competition.
  • SPAAC is effective across pH 6–8; reaction rate increases with temperature and concentration; PEG helps mitigate aggregation.
  • Analyze conversions by LC–MS, SDS-PAGE (for proteins), or SPR/QCM for surfaces. Remove excess reagent by desalting or dialysis as appropriate.
Reaction Conditions

The following are general literature guidelines; optimize per system. No item-specific specifications are provided in the Product Data.

SPAAC (DBCO + Azide)

  • Solvent/buffer: PBS or HEPES, pH 6.5–8.0; 0–20% DMSO/DMF cosolvent if needed for solubility.
  • Concentration: 10–500 µM for biomolecules; 1–50 mM for small-molecule synthesis.
  • Stoichiometry: 1.1–2.0 equiv DBCO per azide site for complete conversion on biomolecules.
  • Temperature/time: 20–37 °C; minutes to a few hours depending on concentration and sterics. Gentle mixing; no degassing required.
  • Notes: Exclude sodium azide; light protection can minimize side reactions.

Amide coupling (installing DBCO-PEG-NH2 onto carboxyls)

  • Activation: EDC (1–1.5 equiv) + NHS or sulfo-NHS (1.2–2 equiv) in aqueous buffer pH 5.5–6.0 for activation, then adjust to pH 7.5–8.5 for amine coupling; or use NHS-activated esters directly.
  • Organic media alternative: In anhydrous DMF or DCM, use HATU/HOAt or TBTU with DIPEA (2–4 equiv) at 0–25 °C for 0.5–4 h for small molecules.
  • Protein conjugation: Work at 4–25 °C, pH 7.5–8.3, with limited organic cosolvent. Quench unreacted NHS esters with Tris or ethanolamine after coupling.

Workup/purification

  • Small molecules: Aqueous workup, extraction, and silica or reverse-phase chromatography (protect DBCO from prolonged strong acid/base).
  • Bioconjugates: Desalting columns, dialysis, spin filters (MWCO 3–30 kDa), or size-exclusion chromatography.

Analytics

  • Follow reaction by LC–MS (small molecules), UV–Vis (if payload is chromophoric), or SDS-PAGE/SEC for proteins.
Safety and Handling

Item-specific safety (from Product Data)

  • GHS classification, signal word, hazard statements, and pictograms: Not specified for this item; refer to SDS.

General safety considerations for DBCO–PEG–NH2 (literature/practice)

  • Potential hazards: Primary amines may cause skin/eye irritation and respiratory irritation if aerosolized. Aromatic strained alkynes can be harmful if ingested/inhaled and may be light-sensitive.
  • PPE: Wear lab coat, safety glasses or face shield, and appropriate chemically resistant gloves (e.g., nitrile). Use in a fume hood to avoid inhalation of vapors/aerosols.
  • Incompatibilities: Avoid strong oxidizers, strong acids/bases, and azide-containing decontamination solutions that could trigger unintended SPAAC. Copper is not required; avoid copper catalysts if copper-free bioconjugation is intended.
  • First aid (overview; defer to SDS):
    • Skin/eye contact: Rinse with water for ≥15 minutes; remove contaminated clothing. Seek medical attention for persistent irritation.
    • Inhalation: Move to fresh air; seek medical attention if symptoms persist.
    • Ingestion: Rinse mouth; do not induce vomiting; seek medical attention.
  • Spill response: Absorb with inert material, collect in compatible container, and decontaminate surfaces with suitable solvent/detergent. Prevent environmental discharge.
  • Storage notes: Store tightly closed at room temperature per Product Data. General best practice: protect from light and moisture, and keep desiccant in the container.

Authoritative source: Always consult the product-specific SDS for definitive hazard and response information.

Solvent Selection

Applicability

  • This is a bifunctional linker/reagent rather than a bulk solvent. Solvent selection here refers to media for dissolution and for conjugation reactions.

General solvent behavior (literature)

  • Polarity: Amphiphilic. PEG chain confers hydrophilicity; DBCO aromatic system imparts hydrophobic character.
  • Common solvents: High solubility in DMSO, DMF, NMP, dichloromethane (DCM), and acetonitrile. Many variants are moderately to highly soluble in aqueous buffers, especially with longer PEG.
  • Aqueous miscibility: Stock solutions are often prepared at 10–50 mM in anhydrous DMSO or DMF, then diluted into phosphate or HEPES buffers for SPAAC.

Choosing media by use-case (general)

  • Amide coupling (to carboxylates/NHS esters): DMF, DMSO, or DCM with a base (e.g., DIPEA) for small molecules; mixed DMF/buffer systems (pH 7.5–8.5) for biomolecules.
  • SPAAC with azides on biomolecules: Aqueous buffers (PBS, HEPES, or saline) at pH 6.5–8.0; small organic cosolvent (≤10–20% DMF or DMSO) can aid solubility without denaturing proteins.
  • Surface modification: Use anhydrous organic solvents for polymer substrates; buffered aqueous media for hydrophilic surfaces.

Brief comparison (general)

  • DBCO vs BCN/DIBAC: DBCO is typically more hydrophobic but highly reactive; BCN can offer improved aqueous solubility when PEG length is short.
  • Solvent cautions: Avoid amine-reactive solvents/additives (e.g., phosgene derivatives) and azide contaminants that can consume DBCO.
Storage and Reconstitution

Item-specific storage and shipping (from Product Data)

  • Storage conditions: Room temperature.
  • Shipped in: Normal.

General best practices (literature/practice)

  • Light/moisture protection: Store in a tightly sealed, light-resistant container with desiccant to preserve DBCO activity and minimize PEG hygroscopic uptake.
  • Stock solutions: Prepare concentrated stocks (e.g., 10–50 mM) in anhydrous DMSO or DMF for convenience. Aliquot to minimize freeze–thaw and headspace moisture.
  • Aqueous solutions: Prepare fresh before use; the amine can undergo slow degradation and DBCO can be consumed by trace azides over time. Short-term storage at 4 °C is acceptable; avoid sodium azide preservatives.
  • Shelf life: Not specified for this item; refer to CoA/Spec Sheet. Verify activity by a small-scale test click if material has been stored for extended periods.
  • Compatibility: Avoid prolonged exposure to strong acids/bases and oxidants. Do not store in buffers containing primary amines (may react with activated forms) or azides (will consume DBCO).

Reconstitution guidance

  • Warm viscous materials gently to room temperature to facilitate dissolution. Sonication can aid dissolution in DMSO/DMF.
  • Filter sterilization (0.22 µm) is possible for aqueous working solutions if required for biological assays; verify no loss by adsorption to filters for low-concentration work.

Research use note

  • For research use only.
Structure and Identity

Item-specific identifiers (from Product Data)

  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • CAS, CID, InChIKey, SMILES: Not specified for this item; refer to CoA/Spec Sheet.

General structural description (literature)

  • Core motif: DBCO (dibenzocyclooctyne) — a strained cyclooctyne fused to two benzene rings; the ring strain activates the alkyne for copper-free azide–alkyne cycloaddition (SPAAC).
  • Linker: Poly(ethylene glycol) chain (PEGn) providing hydrophilicity, reduced aggregation, and increased aqueous compatibility; PEG length varies by product definition (not specified here).
  • Terminus: Primary amine (–NH2) at the PEG end, enabling amide formation with activated carboxyls (e.g., NHS esters) or other electrophiles.
  • Functional groups: Strained internal alkyne (DBCO), aryl rings (two benzene rings), ether repeats (–CH2–CH2–O–)n in PEG, terminal primary amine.
  • 2D depiction in words: Two fused benzene rings share a cyclooctyne ring bearing an internal alkyne; one benzylic position is tethered to a flexible –(O–CH2–CH2)n– chain that terminates in –NH2.

Stereochemistry (literature)

  • DBCO ring adopts conformations driven by ring strain; no stereocenters are inherent. PEG segment is achiral and conformationally flexible.

Naming notes (literature)

  • Common synonyms: DBCO–PEG–NH2, DBCO-amine linker, dibenzocyclooctyne–PEG–amine. Exact PEG length and counterions (if any) determine formal registries and MW.
Synthetic Utility

Functional group strategy (literature)

  • Dual-function linker: The molecule presents a nucleophilic primary amine and a strained alkyne. This orthogonality enables sequential ligations: first amide coupling (amine→carboxyl), then SPAAC (DBCO→azide), or the reverse when using activated azides.
  • PEG spacer: Controls distance and solubility, reduces steric hindrance in macromolecular or surface settings, and allows fine-tuning of conjugate properties by varying PEG length.

Common transformations

  • Amide coupling: With NHS esters, acid chlorides, anhydrides, or via EDC/NHS activation of carboxylates on biomolecules, polymers, or small molecules.
  • Urethane/thiourea formation: Reaction of the amine with chloroformates/activated carbonates or isothiocyanates to create carbamate/thiourea linkages.
  • SPAAC click: Rapid, selective triazole formation with organic azides on probes, polymers, or biomolecules; no copper catalyst required.

Retrosynthetic planning

  • Use DBCO-PEG-NH2 as a convergent module: install onto one partner through its amine, then connect to an azide-functional counterpart late-stage to minimize protecting group manipulations.

Selectivity and compatibility

  • The DBCO alkyne tolerates water, oxygen, and many functional groups; avoid azide-containing preservatives to prevent premature consumption.
  • The amine may require protection (e.g., Boc) if orthogonal manipulations are planned prior to final conjugation.

Characterization

  • Monitor progress by NMR (aromatic DBCO signals, PEG envelope), LC–MS/MALDI for mass shifts, and chromatographic purity (HPLC/SEC for bioconjugates).
Target Specificity

Not applicable to this product type.

  • This reagent is a chemical linker for SPAAC and amide coupling. It does not possess inherent biological target specificity (no antigen/epitope/clone/isotype). Any selectivity arises solely from the presence of azide partners or accessible carboxyl groups created by the user on their substrate.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.