Magnetic adsorbent - Matrix:SiO2,Surface group:-C18,Size:3-4um,unit:10mg/ml

Cat. No.: M121908
AVAILABLE TO ORDER
GRADE & PURITY Matrix:SiO2,Surface group:-C18,Size:3-4um,unit:10mg/ml
Storage
Room temperature
Shipped In
Normal
★
Size
Germany (EU)
USA*
Price
Qty
5ml
M121908-5ml
—
2 In stock

€98.84

€129.21
Save €30.37 (23.51%)
Enter a quantity for the sizes you want to add.

Specifications

Specifications & Purity
Matrix:SiO2,Surface group:-C18,Size:3-4um,unit:10mg/ml
Storage
Room temperature
Shipped In
Normal

Advanced Data

Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDateItem
G2228794G2228794Certificate of AnalysisMay 19, 2026 M121908
Solution Calculators
Reviews

Customer Reviews

Application Protocols

No item-specific validated protocols are provided for M121908. The following are generalized, literature-based procedures for magnetic solid-phase extraction (MSPE) and scavenging; adapt to your matrix and verify against the CoA.

Magnetic SPE (general):

  1. Equilibrate: Resuspend sorbent; wash 3× with binding buffer/solvent (1 bed volume each). For dry powders, wet with a miscible solvent before aqueous buffers.
  2. Load: Add sorbent to sample (typical 1–20 mg mL−1); mix gently 5–20 min.
  3. Separate: Place tube on magnetic rack until supernatant clears (seconds–minutes); decant.
  4. Wash: Add wash solution; resuspend; magnetically separate; repeat 1–3×.
  5. Elute: Add strong eluent (pH shift, salt, or organic solvent); mix 2–10 min; separate; collect eluate. Validate recovery.

Scavenging after synthesis (general):

  1. Condition: Pre-wet sorbent in reaction solvent.
  2. Treat: Add 5–50 wt% vs crude impurities (optimize empirically); stir 10–60 min at ambient.
  3. Quench/separate: Apply magnet; decant product solution.
  4. Rinse: Wash sorbent with fresh solvent; combine rinses with product.
  5. Analyze: Confirm impurity removal by GC/LC/ICP.

Notes:

  • For nanopowders, brief sonication improves dispersion; avoid over-sonication if it damages coatings.
  • Record separation time and recovery for reproducibility.
  • Use low-bind plastics/glassware to minimize loss of analyte by vessel adsorption.
Biological Roles

This product is an engineered material for laboratory use and does not possess an inherent biological role. No biomolecular identity, pathway involvement, or organismal function is specified for M121908.

General, literature-based context for magnetic adsorbents in biological workflows (not specific to this item):

  • As carriers: functionalized magnetic particles can present ligands (e.g., streptavidin, protein A/G, Ni-NTA) to capture biotinylated molecules, antibodies, or His-tagged proteins. The magnetic property enables rapid wash and elution steps with minimal shear.
  • Nucleic acid workflows: carboxylated or silica-like magnetic surfaces are widely used for DNA/RNA binding under chaotropic or PEG/NaCl crowding conditions; elution in low-salt buffers or water.
  • Cell isolation: surfaces bearing antibodies or small-molecule ligands can isolate specific cell populations; separation is gentle compared to centrifugation. Note: no such specificity is stated for this item.
  • Proteomics/metabolomics cleanup: removal of salts, detergents, or selective enrichment (e.g., phosphopeptides with IMAC/TiO2-like magnetics).

Caveats:

  • Biomolecule compatibility depends on surface chemistry, particle size, and buffer composition (pH, ionic strength, additives). Without item-specific details, users should validate binding capacity, nonspecific adsorption, and elution conditions empirically.

Research use only: not for diagnostic or therapeutic applications.

Buffer Applications

Traditional buffer formulation guidance is not directly applicable because this product is a solid adsorbent. However, buffers play a central role in adsorption performance and selectivity.

Item-specific buffer compatibility: Not specified for this item; refer to CoA/Spec Sheet.

General, literature-based guidance:

  • pH control: adsorption of ionizable analytes and surface-charged adsorbents follows acid–base equilibria. Choose buffer pH to favor desired charge states (e.g., opposite charges for electrostatic capture, neutralization for hydrophobic interactions).
  • Ionic strength: higher salt can screen electrostatics, reducing nonspecific binding; conversely, certain captures (e.g., ion exchange) require low ionic strength during binding and high salt for elution.
  • Common buffer systems: phosphate (pH 6–8), Tris (pH 7–9), acetate (pH 4–5.5), citrate (pH 3–6). Select compatible buffers that do not corrode the coating (avoid strong base for silica shells; avoid strong acid for iron oxide cores).
  • Additives: low concentrations of nonionic surfactants (e.g., Tween-20) may reduce nonspecific protein binding on hydrophobic surfaces; crowding agents (PEG/NaCl) promote nucleic acid binding to carboxyl/silica-like surfaces.
  • Organic modifiers: small percentages of alcohols or acetonitrile can tune hydrophobic interactions and reduce viscosity.

Practical protocol sketch (general):

  • Equilibrate beads in binding buffer (5–10 bed volumes), add sample, incubate with gentle mixing, magnetically separate, wash 2–3× with wash buffer, elute with pH/salt/organic modifier as appropriate. Validate recovery and carryover empirically.
Green Alternatives

Magnetic adsorbents support greener lab practices by enabling rapid, filtration-free separations and reduced solvent/consumable use. While item-specific details for M121908 are not provided, the following general sustainability considerations apply (literature/general):

Benefits vs conventional approaches:

  • Reduced solvent usage: magnetic separations in MSPE or scavenging often require smaller elution volumes compared to gravity or vacuum SPE cartridges.
  • Lower solid waste: eliminates filter papers and many single-use cartridges; sorbent reusability is feasible for robust coatings.
  • Energy/time efficiency: no centrifugation; ambient-temperature handling with short contact times.

Comparison (general):

  • Magnetic adsorbent vs centrifugation: avoids high-energy spinning; gentler on shear-sensitive analytes.
  • Magnetic adsorbent vs silica SPE: less backpressure, simpler workflow; however, device-based SPE may provide sharper fractionation for complex gradients.
  • Magnetic adsorbent vs precipitation: improved selectivity; fewer co-precipitated impurities.

Trade-offs:

  • Potential metal leaching (Fe) into acidic media if cores are not well protected; mitigate with robust shells (silica, carbon) and controlled pH.
  • Polymer-coated materials may introduce organic extractables; thorough pre-washing reduces blanks.
  • End-of-life: consider regeneration protocols (e.g., solvent wash, mild acid/base) and appropriate disposal routes according to SDS.

Greener practice tips:

  • Use minimal effective sorbent mass and elution volume.
  • Reuse when performance allows; document capacity fade across cycles.
  • Select aqueous-compatible workflows where possible and avoid chlorinated solvents unless required.

Consult the CoA/SDS for compatibility and regeneration guidance.

Pharmaceutical Uses

No pharmacopeial status, excipient designation, or clinical use is specified for M121908. This product is supplied strictly for research use only.

General manufacturing and R&D context (literature/general):

  • Process development: magnetic adsorbents can be used at bench scale to screen binding/elution conditions for chromatographic separations, enabling rapid DoE screens without columns.
  • Analytical sample prep: cleanup of small-molecule formulations (removal of proteins, phospholipids, or matrix interferences) prior to LC–MS; supports robust quantitation in stability or release testing workflows.
  • Catalyst removal/scavenging: in medicinal chemistry or process route scouting, functionalized magnetic sorbents remove residual metal catalysts (Pd, Cu, Ni) or reagents, accelerating iteration and reducing silica waste.
  • Affinity capture (research): testing ligands and tags (e.g., His-tag, biotin) in assay development; translating conditions to chromatographic media after optimization. Note: no specific affinity for M121908 is stated.

Considerations for regulated environments:

  • For GMP or clinical manufacturing, materials require defined specifications (particle size, extractables/leachables, bioburden/endotoxin if used near drug substance) and change control. Such controls are not specified for this catalog item; consult Aladdin for suitability.
  • Cleaning and reuse validation must document carryover, capacity loss, and potential leachables. Establish acceptance criteria and analytical monitoring (e.g., ICP for Fe, residual ligand assays).

This product should not be used as an excipient or API component.

Physical Properties

Item-specific property data are not provided in the Product Data for M121908.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Bulk density / tapped density: Not specified for this item; refer to CoA/Spec Sheet.
  • Particle size / PSD / mean diameter: Not specified for this item; refer to CoA/Spec Sheet.
  • Surface area (BET), pore size, pore volume: Not specified for this item; refer to CoA/Spec Sheet.
  • Isotherm model parameters (Langmuir/Freundlich), qmax, KD: Not specified for this item; refer to CoA/Spec Sheet.
  • Zeta potential / IEP: Not specified for this item; refer to CoA/Spec Sheet.
  • Solvent compatibility and dispersibility: Not specified for this item; refer to CoA/Spec Sheet.
  • Moisture content / LOI: Not specified for this item; refer to CoA/Spec Sheet.

Literature/general characteristics for magnetic adsorbents (for context; not item-specific):

  • Magnetic responsiveness enables rapid separation in external fields (seconds to minutes) without filtration or centrifugation.
  • Typical formats: dry powder, aqueous slurry, or ethanolic slurry; dispersibility depends strongly on surface chemistry (e.g., hydrophilic carboxylate/PEG vs hydrophobic alkyl coatings).
  • Thermal stability generally governed by coating: inorganic (silica) shells tolerate higher temperatures than polymeric shells.
  • pH stability windows vary: bare iron oxides may dissolve/transform in strong acid (pH <2) or aggregate near the isoelectric point; silica shells are sensitive to strong base (pH >10–11) (literature/general).

Always consult the CoA/Spec Sheet for numerical specifications and the SDS for handling and compatibility details.

Quality and Grades
  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.

Interpretation and general context (literature/general):

  • Magnetic adsorbents are offered in various quality tiers tailored to application: analytical grade for sample prep (e.g., magnetic solid-phase extraction, MSPE), synthesis grade for scavenging/catalysis, and bioprocess-grade for affinity capture. The grade typically constrains levels of extractables, particle-size distribution, magnetic content, and leachables (e.g., Fe release).
  • Purity/cleanliness considerations include residual monomers (polymer-coated types), surfactants, and inorganic salts from synthesis. For trace analysis, low-blank/low-background materials and pre-washes are important to minimize contamination.
  • Surface functionality quality is defined by ligand density, accessibility, and batch-to-batch reproducibility; CoA may include titration data (µmol functional group per g), which guides capacity estimates for adsorption or scavenging.
  • Endotoxin/bioburden specifications may be relevant for bioprocessing-grade materials; for research chemical use, such specs are typically not controlled unless stated.
  • UV cutoff, metal limits, water/peroxide ppm: Not specified for this item; refer to CoA/Spec Sheet.

What to verify on receipt:

  • CoA for particle size, magnetic response (e.g., separation time), solids content (if slurry), and functional group loading.
  • Visual inspection for aggregation/sedimentation behavior relative to documentation; gentle sonication may be used to re-disperse if appropriate for the coating.
Reaction and Applications

Applications for magnetic adsorbents span separations, analytics, and synthesis. Item-specific use cases for M121908 are not provided; the following are general, literature-based applications and practical tips.

  • Magnetic solid-phase extraction (MSPE):

    • Workflow: condition → load sample → adsorb → magnetic separation → wash → elute.
    • Advantages: rapid phase separation without filtration/centrifugation; scalable from µL to liters; reduced solvent consumption.
    • Targets: organic pollutants, pesticides, dyes, drugs, metals (with chelators), and biomolecules depending on surface functionality.
  • Scavenging in synthesis: removal of residual catalysts (e.g., Pd, Cu), reagents (isocyanates, acids/bases), and byproducts using functionalized surfaces; rapid magnet-enabled cleanup reduces silica waste and simplifies workups.

  • Catalyst supports: immobilized acids/bases, organocatalysts, or metal nanoparticles on magnetic cores; easy recovery and reuse via a magnet; suitable for flow or batch.

  • Biomolecule handling (research use): nucleic acid cleanups, protein/peptide enrichment, cell isolation when bearing appropriate affinity ligands (e.g., streptavidin, IMAC). For this catalog item, specific ligands are not specified.

Practical tips (general):

  • Pre-equilibrate the adsorbent in the working medium; gently vortex/sonicate to disperse.
  • Determine capacity experimentally for your matrix; start with conservative loading (e.g., 1–10 mg sorbent per mL of sample) and optimize.
  • Use clean magnetic racks; avoid strong magnetic field gradients near analytical balances.
  • Minimize irreversible aggregation: avoid high ionic strength near the isoelectric point and add dispersants compatible with your assay if needed.

Always consult the item’s CoA for coating, capacity, and recommended operating ranges.

Reaction Conditions

Item-specific operating conditions for M121908 are not provided. The following literature-based guidance summarizes typical conditions for magnetic-adsorbent workflows; users should optimize empirically.

Magnetic solid-phase extraction (general):

  • Sorbent dosage: 1–50 mg per mL of sample depending on analyte concentration, matrix complexity, and capacity.
  • Contact time: 1–30 min with gentle agitation (end-over-end or vortex); nanosized materials often reach equilibrium faster.
  • pH: set to favor adsorption (e.g., opposite charge for ion exchange; neutral for hydrophobic capture); common range pH 3–10 depending on coating stability.
  • Wash: 1–3 bed volumes of weak solvent/low salt to remove matrix interferences.
  • Elution: strong solvent, pH shift, or high ionic strength; 0.5–5 mL typical for analytical MSPE.

Scavenging (general):

  • Solvents: choose those compatible with the reaction mixture (e.g., EtOAc, MeOH, ACN, toluene, THF). Stirring/overhead mixing improves kinetics.
  • Temperature: ambient to 60 °C common; higher temperatures accelerate kinetics but must respect coating stability.
  • Time: 5–120 min; monitor by TLC/GC/LC.

Catalysis on magnetic supports (general):

  • Solvent: as required by catalyst/substrate; degas if air/moisture-sensitive.
  • Temperature: room temperature to reflux; track catalyst integrity and leaching.
  • Recovery: immobilize catalyst with an external magnet; decant; wash and reuse.

Reporting and QC:

  • Document separation time in a standardized magnetic field geometry for reproducibility.
  • Characterize reusability (cycles to 90% capacity) and potential analyte carryover.

Always verify coating compatibility and safe pH/solvent windows on the CoA/SDS.

Safety and Handling

Hazard information provided for this item: not specified.

  • Signal word: Not specified for this item; refer to SDS.
  • H-statements: Not specified for this item; refer to SDS.
  • GHS classification/pictograms: Not specified for this item; refer to SDS.

General laboratory safety guidance (literature/general):

  • PPE: wear lab coat, safety glasses, and appropriate gloves. Use a dust mask/respirator if handling fine powders that may become airborne. Work in a fume hood or ventilated enclosure when weighing nanoparticulates.
  • Incompatibilities: magnetic particles can be attracted to strong permanent magnets and magnetized tools; keep away from sensitive instruments (balances, electronic storage media) and pacemaker zones. Avoid strong acids/bases or oxidants unless compatible with the specific coating.
  • Spill/cleanup: avoid creating dust; gently wet with compatible medium to suppress dust, collect with plastic spatula. Use a magnet behind a protective film to assist in recovery of magnet-responsive material.
  • First aid (overview; defer to SDS):
    • Inhalation: move to fresh air; seek medical attention if irritation persists.
    • Skin/eye contact: rinse with water for several minutes; remove contaminated clothing; seek medical advice if irritation persists.
    • Ingestion: rinse mouth; do not induce vomiting; obtain medical attention.
  • Fire-fighting: most inorganic cores are noncombustible, but organic coatings/packaging may burn; use media appropriate for surrounding fire. Thermal decomposition of coatings may release irritating fumes.

Research use only: not for human or animal diagnostic/therapeutic use. Always consult the item-specific SDS for authoritative safety measures.

Solvent Selection

Because this product is a solid adsorbent rather than a solvent, traditional “solvent selection” does not directly apply. However, dispersion media and process fluids are critical for performance.

Item-specific compatibility: Not specified for this item; refer to CoA/Spec Sheet.

General guidance (literature/general):

  • Hydrophilic, oxide- or silica-like surfaces typically disperse in water, alcohols, and many buffers. Amino/carboxylate-functionalized materials are commonly used in aqueous systems; ionic strength and pH control electrostatic interactions and stability.
  • Hydrophobic/polymeric coatings (e.g., alkyl, polystyrene) favor organic media (e.g., alcohols, acetonitrile, ethers, hydrocarbons). Mixed solvent systems can tune polarity during adsorption/desorption sequences.
  • Avoid media that degrade the coating: strong base can etch silica; strong acid can dissolve iron oxide; good practice is to maintain pH 3–10 unless the coating is rated otherwise.
  • For LC–MS sample prep, choose high-purity solvents with low nonvolatile residue; pre-equilibrate the adsorbent in the same solvent composition as the sample to minimize perturbations.

Small comparison (general):

  • Water/buffers: best for biomolecule capture, ion exchange; easy magnetic handling.
  • Alcohols (MeOH/EtOH/i-PrOH): moderate polarity, useful for conditioning and elution.
  • Acetonitrile: strong eluent for organics; compatible with many polymer/silica shells.
  • Nonpolar solvents (hexanes/toluene): used with hydrophobic coatings or for scavenging nonpolar reagents.

Always confirm solvent compatibility and recommended pH window with the item’s CoA/SDS.

Storage and Reconstitution
  • Storage conditions (as provided): Room temperature. Shipped at ambient (Normal). Protect from extremes of heat and cold.
  • Packaging state (dry vs slurry), stabilizers/preservatives, and exact storage limits: Not specified for this item; refer to CoA/Spec Sheet and SDS.

General storage guidance (literature/general):

  • Dry powders: store tightly sealed in a desiccated environment to minimize moisture uptake and aggregation. Keep away from strong magnetic fields. If hygroscopic, handle quickly under low humidity.
  • Aqueous slurries: store tightly capped to prevent evaporation; gently invert before use to re-homogenize. If biologically sensitive applications are not intended, low levels of a compatible preservative are sometimes used; follow item-specific SDS—do not add preservatives unless validated for your workflow.
  • Organic slurries: ensure cap integrity to limit solvent loss; periodically check solids content and dispersion.

Reconstitution/dispersion (general):

  • For dry materials: wet with a miscible solvent (e.g., ethanol or the target solvent) before transferring to the working medium; vortex or briefly sonicate to disperse. Avoid pH/extremes that destabilize the coating (unknown for this item—titrate cautiously).
  • For slurries: mix thoroughly to a uniform suspension prior to aliquoting; determine solids content to dose by mass of solids.

Stability checks:

  • Monitor separation time, adsorption capacity, and visible aggregation over time. If performance drifts, regenerate per CoA (if available) or replace the material.

Always defer to the product’s CoA/Spec Sheet and SDS for definitive storage and handling instructions.

Structure and Identity
  • Item name: Magnetic adsorbent (SKU: M121908)
  • Identity specifics for this catalog item are not disclosed.
    • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
    • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
    • CAS/CID: Not specified for this item; refer to CoA/Spec Sheet.

General chemistry context (literature/general):

  • “Magnetic adsorbent” commonly denotes particulate solids with a magnetic core (often iron oxide such as magnetite Fe3O4 or maghemite γ‑Fe2O3) and a surface engineered for adsorption (e.g., bare oxide, silica shell, polymer coating, or functional ligands like –COOH, –NH2, –SO3H, chelators, or affinity groups).
  • Typical architecture: core–shell nanoparticles or microbeads; core provides magnetic responsiveness; shell/skin provides chemical selectivity and colloidal stability.
  • 2D structural features (descriptive): spherical particulate domains with an inorganic magnetic core; optional inorganic or organic shell; terminal functional groups confer acid/base/ion-exchange/hydrophobic or affinity behavior.
  • Magnetic behavior (literature): nanoscale iron oxide cores often exhibit superparamagnetism—rapid magnetization under a field and negligible remanence, enabling quick magnetic separation without permanent aggregation when the field is removed.

Important note:

  • Because the exact composition, surface chemistry, and particle size distribution for M121908 are not specified here, treat the above as general guidance. For precise identity, surface groups, and assay data, consult the product’s CoA/Spec Sheet and SDS.
Synthetic Utility

Magnetic adsorbents provide versatile tools in organic and organometallic synthesis by combining tunable surface chemistry with magnet-enabled separations. Item-specific functionality for M121908 is not provided; below are general, literature-based utilities.

  • Scavenger resins: remove electrophiles (e.g., acid chlorides, isocyanates), nucleophiles (amines, thiols), acids/bases, or metals via functional groups such as primary amines, thiols, sulfonic acids, or chelators immobilized on the particle surface. Rapid magnetic decantation simplifies workups and scale-down purifications.
  • Heterogeneous catalysis: support for Pd/Cu/Ni nanoparticles, organocatalysts (e.g., proline derivatives), or acid/base sites (sulfonic acid, amines). Easy recovery allows catalyst reuse and minimizes metal contamination in products.
  • Flow/batch adaptability: magnetically retained beds can be created in microreactors; in batch, a magnet immobilizes the catalyst during reagent transfers.
  • Solid-phase synthesis and catch-and-release: temporary immobilization of intermediates or protecting-group-laden species followed by on-bead transformations and magnetic separation.

Practical notes:

  • Pre-condition the adsorbent in the reaction solvent; ensure compatibility of shell/coating with temperature and reagents.
  • Determine sorbent capacity by small-scale titration; avoid overloading which can reduce kinetics.
  • For metal-scavenging, validate residual metal by ICP-MS/ICP-OES; for catalyst supports, track activity decay across cycles and monitor leaching.
  • Avoid strong acids/bases or high temperatures that compromise the shell (silica/base; iron oxide/acid) unless the material is rated accordingly.

Consult the CoA/Spec Sheet for coating identity and recommended operating ranges before deploying in synthesis.

Target Specificity

No target, antigen, ligand, or selectivity information is specified for M121908 in the Product Data.

General note (literature/general):

  • Magnetic adsorbents may be engineered with specific functionalities (e.g., ion-exchange groups, hydrophobic coatings, chelators, affinity ligands like streptavidin, protein A/G, or Ni-NTA) that confer target specificity. In absence of item-specific details, do not assume any selectivity.

Action for users:

  • Consult the CoA/Spec Sheet for surface chemistry, functional group loading (µmol g−1), and validated targets if applicable.
  • If unspecified, perform small-scale screening to map binding vs pH/ionic strength/organic modifier and to quantify nonspecific adsorption.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.