"}

Panitumumab ELISA Kit

In stock
SKU
EJ1515740
Grouped product items
Product Name Qty
[EJ1515740-48T] Panitumumab ELISA Kit (48T)
€494.52
[EJ1515740-96T] Panitumumab ELISA Kit (96T)
€754.85

This kit employs the indirect enzyme-linked immunosorbent assay (ELISA) principle. Microplate wells are pre-coated with Human EGFR antigen. The sample or standard is first added to the wells, followed by an HRP (horseradish peroxidase)-labeled secondary antibody. The procedure involves incubation and wash steps between each addition. TMB substrate is then added for color development. Under the catalysis of the peroxidase (HRP), TMB is converted into a blue product, which subsequently turns into a final stable yellow color upon the addition of an acid stop solution. The intensity of the yellow color is directly proportional to the concentration of Panitumumab in the sample. The optical density (OD) is measured at a wavelength of 450 nm using a microplate reader, and the concentration of the target analyte in the sample is calculated based on the standard curve.

More Information

More Information
Specifications & PurityBioReagent
Detection Range0.78ng/mL~50ng/mL
Detected Species ObjectHuman
SpecificityDetecting Human Panitumumab in samples, with no significant cross-reactivity to other homologs.
Product Description

This kit employs the indirect enzyme-linked immunosorbent assay (ELISA) principle. Microplate wells are pre-coated with Human EGFR antigen. The sample or standard is first added to the wells, followed by an HRP (horseradish peroxidase)-labeled secondary antibody. The procedure involves incubation and wash steps between each addition. TMB substrate is then added for color development. Under the catalysis of the peroxidase (HRP), TMB is converted into a blue product, which subsequently turns into a final stable yellow color upon the addition of an acid stop solution. The intensity of the yellow color is directly proportional to the concentration of Panitumumab in the sample. The optical density (OD) is measured at a wavelength of 450 nm using a microplate reader, and the concentration of the target analyte in the sample is calculated based on the standard curve.

StorageStore at 2-8°C
Shipped InWet ice
Stability And StorageStore at 2-8℃ for 6 months.

Reviews

Customer Reviews

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.

Copyright © 2023-present Aladdin Scientific Corp All rights reserved.