PLLA5000-PEG5000-RhB is a terminal rhodamine-labeled polylactic acid derivative. PLLA5000-PEG5000-RhB can be used to label nanomicelles for real-time monitoring of drug release in vivo.
Specifications
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
This product requires cold chain shipping. Ground and other economy services are not available.
Advanced Data
Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Solution Calculators
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Reviews
Customer Reviews
Application Protocols
No manufacturer-validated application protocols are provided for this specific item. The following are general, literature-based workflows for amphiphilic PLLA–PEG–dye materials; adjust to your system and refer to internal SOPs.
Preparation of fluorescent micelles (nanoprecipitation):
Dissolve polymer at 5 mg/mL in acetone. 2) Filter (0.22 µm PTFE). 3) Add 1 mL stock dropwise into 10 mL PBS (pH 7.4) under 800 rpm stirring. 4) Stir 30 min. 5) Remove acetone by nitrogen sparging or dialysis (MWCO 10–50 kDa). 6) Store dispersion at 4 °C protected from light. Measure DLS and fluorescence.
Removal of free dye (if present):
Dialysis against PBS with 2–3 buffer exchanges over 24 h or size-exclusion chromatography (e.g., Sephadex G-25) to separate small molecules from polymer assemblies.
Film casting for imaging:
Dissolve polymer (10 mg/mL) in ethyl acetate. 2) Spin coat on clean glass at 2,000 rpm for 60 s. 3) Vacuum dry ≥4 h. 4) Image with TRITC filter set.
Spectroscopic characterization:
Record UV–Vis of stock solution to confirm RhB absorbance peak. Determine fluorescence spectra using TRITC settings; maintain absorbance ≤0.05 AU to avoid inner-filter effects.
Note: No item-specific recommended concentrations or instrument settings are provided; optimize per application.
Biological Roles
This product is intended strictly for research use. The notes below describe general, literature-based roles of the constituent motifs; they are not product specifications or medical claims.
PEG segment (literature/general): Hydrophilic, flexible chains that promote hydration layer formation and reduce nonspecific protein adsorption on surfaces ("stealth" behavior). In assemblies, PEG provides steric stabilization and can modulate biological interactions.
PLLA segment (literature/general): Aliphatic polyester that undergoes hydrolytic degradation to lactic acid; degradation rate depends on crystallinity, molecular weight, and environment (pH, temperature, enzymes). Serves as a biodegradable hydrophobic domain for cargo encapsulation in research carriers.
Rhodamine B label (literature/general): Bright xanthene dye with excitation/emission typically ~540–560/570–590 nm. Often used to visualize nanostructure localization, adsorption, or uptake in cell culture and to quantify partitioning or diffusion in biomimetic systems.
Assembly behavior: Amphiphiles of this type form micelles or nanoparticles in water/buffers with PEG coronas and PLLA-rich cores. The fluorescent tag allows tracking of particle stability, dissolution (as PLLA degrades), and interactions with biomolecules.
Note: Actual in vitro/in vivo biological performance depends on many experimental variables (concentration, serum proteins, ionic strength, pH, shear, and any co-formulated actives). Verify behavior empirically for each application.
Buffer Applications
This material is not a buffering reagent. However, it is commonly dispersed in buffers for colloidal assembly and biointerface studies (literature/general guidance):
Compatible buffers: PBS (pH ~7.4), HEPES (pH 7.2–7.6), and citrate/phosphate buffers for stability screens. Filter buffers (0.22 µm) to prevent nucleation on particulates.
pH considerations:
PLLA ester bonds hydrolyze faster at elevated pH (>8) and temperature; neutral buffers slow degradation and are generally preferred for stability work.
Rhodamine B fluorescence is pH-sensitive; protonation state can affect quantum yield and spectral position (monitor with controls).
Ionic strength: High salt can compress the PEG corona slightly and influence aggregation number; test NaCl from 0–150 mM to map stability windows.
Additives: Small percentages of ethanol (5–20%) or acetone can assist initial dispersion before complete solvent exchange; remove by dialysis or nitrogen sparging.
Practical recipe (example workflow, literature): Dissolve polymer at 1–10 mg/mL in acetone or THF; add dropwise into 10× volume of buffer under vigorous stirring; continue stirring 1 h; remove residual solvent; optional dialysis (MWCO selected above expected micelle size) against fresh buffer.
Always validate fluorescence baselines of the buffer system to correct for inner-filter effects and dye–buffer interactions.
Green Alternatives
Opportunities exist to reduce environmental impact during formulation and processing without changing the polymer itself.
Greener solvent choices for processing (literature/general):
Ethyl acetate: Good solubility for PLLA and miscible with limited water; relatively low toxicity and biodegradable.
2-Methyltetrahydrofuran (2-MeTHF): Bio-based ether, similar solubilizing power to THF, lower peroxide tendency and better safety profile; still flammable.
Acetone or ethanol: Widely available, low toxicity; suitable for nanoprecipitation and solvent-switch methods.
Comparison (general):
THF vs 2-MeTHF: 2-MeTHF offers greener sourcing and higher boiling point (easier handling) but can have distinct solubility/selectivity; verify particle size impacts experimentally.
DCM/CHCl3 vs ethyl acetate: EtOAc reduces halogenated waste and is often adequate for film casting; drying may take longer due to higher boiling point.
DMSO/DMF vs ethanol/acetone: DMSO/DMF increase solvency but complicate removal and biological compatibility; EtOH/acetone ease purification but may alter micelle size.
Operational practices:
Employ solvent recycling (rotavap with cold trap) and minimize volumes via concentrated stocks.
Prefer aqueous processing where feasible (thin-film hydration into buffered saline).
Use amber glassware and low-intensity lighting to reduce dye degradation, avoiding repeated remake and waste generation.
Pharmaceutical Uses
No clinical or therapeutic uses are claimed or supported. For research and development contexts only.
Formulation roles (literature/general):
Model carrier polymer: PLLA-PEG amphiphiles are frequently used as research excipients for nanoparticle, micelle, and depot formulations to study encapsulation and release of hydrophobic actives.
Surface modification: PEGylated, fluorescent coatings on test devices or model surfaces to investigate antifouling behavior and surface–protein interactions.
Imaging tag: Rhodamine B labeling enables tracking of polymer carriers during process development (e.g., mixing studies, filtration, and stability testing) without biological claims.
Regulatory/compendial status:
Item-specific pharmacopeial compliance (e.g., USP/NF, EP) is not provided: Not specified for this item; refer to CoA/Spec Sheet.
Residual solvent, monomer, and endotoxin limits relevant to pharmaceutical development are not specified here and should be established via internal specifications if used in preformulation research.
Process considerations:
Ensure thorough removal of organic solvents and free dye prior to biological testing to avoid artifacts.
Evaluate filterability (0.22 µm) and sterility practices if preparing materials for sterile research workflows.
Characterize particle size, PDI, zeta potential, and dye content for batch-to-batch comparability.
Physical Properties
Item-specific physico-chemical parameters are not provided.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight (Mn/Mw, Đ): Not specified for this item; refer to CoA/Spec Sheet. Note: Product name suggests nominal PLLA ~5 kDa and PEG ~5 kDa (literature naming convention, not a specification).
Solubility (general/literature guidance):
PEG segment imparts solubility in polar protic solvents (e.g., water, lower alcohols) when sufficiently hydrated; the PLLA block drives self-assembly in water.
Good solubility typically observed in organic solvents such as DMSO, DMF, THF, dioxane, CHCl3, and acetone for processing and film casting (literature for PLLA-PEG block copolymers).
Critical micelle concentration (CMC): Depends on block lengths and solvent; typically µg/mL to low mg/mL range in aqueous media for 5k-5k amphiphiles (literature, indicative only).
Thermal transitions (literature, general):
PEG crystallization/melting can occur around 45–60 °C depending on block ratio and hydration; PLLA Tg often 50–65 °C and Tm 150–180 °C in homopolymers, but depressed in block copolymers.
Density, refractive index, pKa, logP, BP/MP: Not applicable or not defined for polymers; Not specified for this item; refer to CoA/Spec Sheet.
Note: The presence of Rhodamine B confers strong absorption/emission in the green/orange region (literature: Ex ~540–560 nm, Em ~570–590 nm), but exact photophysics depend on environment and loading; not specified for this item.
Quality and Grades
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Polymer metrics (item-specific): Mn/Mw, dispersity (Đ), dye substitution level, residual solvent/monomer levels, and ash/metals are not provided here; refer to CoA/Spec Sheet for acceptance criteria.
Interpretation (general guidance for polymer/dye conjugates):
Nominal block sizes (e.g., “PLLA5000-PEG5000”) indicate targeted average molecular weights from synthesis; actual Mn, Mw, and Đ should be verified on the accompanying CoA (commonly by GPC/SEC with appropriate calibration).
Dye loading: For end-labeled materials, labeling is often ~1 dye per chain (literature); exact labeling efficiency and residual free dye content materially affect fluorescence background and should be reported on CoA.
Residuals and volatiles: For nanoparticle and bio-interface research, low residual solvent and free dye are preferred to minimize cytotoxic artifacts and background signal. Ask for data on residual solvents (GC), monomer content (e.g., lactide), and water content (Karl Fischer). If not specified, verify in-house.
Stabilizers: Not specified for this item; refer to CoA/Spec Sheet. If present, antioxidants or acid scavengers can influence degradation kinetics and should be disclosed.
Quality impact on use:
Narrow dispersity and accurate dye substitution enhance reproducibility of micellization, particle size, and fluorescence quantitation.
UV–Vis/fluorescence QC (absorbance peak position, extinction coefficient) can serve as a rapid check for dye integrity and lot-to-lot consistency.
Reaction and Applications
Primary utility is as a self-assembling, fluorescent amphiphile for nanomaterials and biointerface studies rather than as a classical small-molecule reagent.
Research applications (literature/general):
Fluorescent micelles and nanoparticles: The PLLA core drives hydrophobic domain formation; PEG corona imparts colloidal stability and protein-resistance; Rhodamine B enables optical tracking (excitation/emission typically in the green–orange region).
Drug encapsulation studies: Model carrier for hydrophobic payloads to investigate loading capacity, release kinetics (PLLA hydrolysis), and stability in serum-mimicking media.
Imaging-assisted transport assays: Track uptake in cell culture models, permeation across barriers, or distribution in microfluidic devices (research use only).
FRET or quenching studies: RhB label can participate in energy transfer in co-assemblies with complementary dyes (literature), allowing probing of assembly morphology.
Film and coating fabrication: Spin-cast or dip-coated fluorescent films for surface energy studies and erosion-controlled release testing.
Practical tips:
Protect from light throughout preparation and storage to minimize photobleaching.
Remove free RhB (if any) via dialysis/SEC to reduce background fluorescence.
Control assembly size by solvent choice, polymer concentration, water addition rate, and temperature. Dynamic light scattering (DLS) is recommended for size QC.
For payload studies, quantify encapsulation efficiency by UV–Vis/HPLC; correct for RhB absorbance overlap.
Reaction Conditions
Not used in classic stoichiometric organic reactions; instead, consider formulation/assembly conditions (literature/general guidance):
Nanoprecipitation:
Stock: 1–10 mg/mL in acetone, ACN, THF, or DMSO.
Antisolvent: Water or buffer at 10–20× volume, stirred vigorously (600–1,000 rpm) at room temperature.
Addition: Dropwise or via syringe pump (0.1–1 mL/min) to control nucleation; maintain constant temperature.
Post-processing: Stir 30–60 min; remove solvent by rotary evaporation under reduced pressure or dialysis; optional 0.22 µm filtration.
Thin-film hydration:
Dissolve polymer in CHCl3/MeOH, THF, or EtOAc; cast a thin film; dry under vacuum (≥4 h) to remove residual solvent.
Hydrate with buffer (polymer 0.5–5 mg/mL), vortex/sonicate as needed; equilibrate 1–2 h.
Particle sizing and stability:
DLS target hydrodynamic diameters often 30–200 nm depending on protocol; verify by TEM/AFM as needed.
Stability screens across pH 5–8 and 0–150 mM NaCl; monitor fluorescence to assess dye leakage/photobleaching.
Fluorescence measurement (RhB, literature): Excitation ~540–560 nm; emission collect ~570–600 nm; use low light to limit bleaching; correct for inner-filter effects above ~0.05 AU.
Note: The above are general conditions reported in literature for similar 5k–5k amphiphiles; optimize empirically for this specific item.
Safety and Handling
GHS classification, signal word, pictograms, H-statements: Not specified for this item; refer to SDS.
General hazards (literature/practice):
Solid polymers may pose low acute toxicity but can cause mechanical irritation; avoid dust generation and inhalation.
Rhodamine dyes can be harmful if ingested; avoid skin/eye contact and inhalation of powders or aerosols.
PPE: Laboratory coat, nitrile gloves, and splash goggles are recommended. Handle in a fume hood when dissolving in volatile organic solvents.
Light sensitivity: Rhodamine B is light-sensitive; minimize exposure to ambient light to prevent photobleaching. Wrap containers in foil during handling and storage.
Incompatibilities (general): Strong oxidizers, strong acids/bases (may hydrolyze PLLA ester linkages), and chlorinating agents. Avoid prolonged exposure to moisture/alkaline media if preserving molecular integrity is critical.
Thermal/processing cautions: Avoid overheating; polymers can degrade to produce irritating fumes. Use inert atmosphere if performing melt-processing or solvent evaporation at elevated temperature.
First aid (overview; defer to SDS):
Skin/eye contact: Rinse cautiously with water for several minutes; remove contaminated clothing; seek medical attention if irritation persists.
Inhalation: Move to fresh air; seek medical attention if symptoms occur.
Ingestion: Rinse mouth; seek medical attention.
Waste: Collect dye-containing polymer waste as hazardous chemical waste; follow institutional and local regulations.
Solvent Selection
This amphiphilic block copolymer is typically processed from organic solvents and then transferred to aqueous media for self-assembly.
Polarity/miscibility (literature/general):
Good solubility in polar aprotic solvents: DMSO, DMF, NMP, THF, dioxane, acetone, acetonitrile.
Soluble in chlorinated solvents: CH2Cl2, CHCl3 (use with caution; consider greener options where feasible).
Limited direct solubility in pure water due to PLLA block; forms micelles/assemblies when dispersed using cosolvents or nanoprecipitation.
Typical use scenarios:
Nanoprecipitation or solvent switch: Dissolve polymer in a water-miscible organic solvent (e.g., acetone, ACN, THF, DMSO), then add to water/buffer under stirring to form micelles or nanoparticles.
Thin-film hydration: Cast a thin film from volatile solvent (e.g., CHCl3/MeOH or THF), remove solvent thoroughly, then hydrate with aqueous buffer.
Buffer compatibility (general): Physiological buffers (PBS, HEPES) are commonly used for dispersion; avoid high pH (>8–9) if ester hydrolysis of PLLA is a concern.
Comparison (selection hints):
THF/acetone enable rapid nanoprecipitation and small particle sizes but may require careful solvent removal.
DMSO offers high solubility but slower removal and potential biological assays interference; dialyze thoroughly.
Ethanol/water systems can be a greener choice with lower toxicity in downstream steps.
Always filter organic stock solutions (0.22 µm PTFE) to remove particulates before formulation.
Storage and Reconstitution
Storage conditions (item-specific): Store at -20°C. Protect from light. Keep tightly sealed. Avoid repeated freeze–thaw cycles of solutions.
Shipped in (item-specific): Ice chest + Ice pads.
Stability (general/literature): Solid polymer–dye conjugates are typically stable for months at -20°C when protected from moisture and light. Hydrolysis of PLLA can occur over time, accelerated by heat, moisture, and base.
Handling:
Allow container to equilibrate to room temperature in the dark before opening to minimize condensation.
Work quickly under low-light or amber conditions to preserve dye integrity.
Reconstitution (general guidance):
Prepare a concentrated stock (e.g., 5–20 mg/mL) in a suitable organic solvent such as DMSO, THF, acetone, or ethyl acetate. Filter through 0.22 µm PTFE.
For aqueous use, employ nanoprecipitation or thin-film hydration followed by exhaustive solvent removal (rotary evaporation, dialysis, or diafiltration).
Solution storage (general):
Short-term (hours–days): 2–8°C protected from light.
Longer-term: Freeze aliquots at -20°C in the dark; avoid repeated freeze–thaw. Assess for changes in DLS size distribution and fluorescence before use.
Specifications not provided: Exact shelf life, water content limits, and residual solvent limits are not specified for this item; refer to CoA/Spec Sheet and confirm with in-house QC as needed.
Structure and Identity
Amphiphilic fluorescent block copolymer composed of poly(L-lactic acid) (PLLA), poly(ethylene glycol) (PEG), and Rhodamine B (RhB) as a terminal dye.
CAS: Not specified for this item; refer to CoA/Spec Sheet.
CID: Not specified for this item; refer to CoA/Spec Sheet.
InChIKey: Not applicable for high-polydispersity polymers; not defined.
SMILES: Not applicable to polymers of undefined length; not defined.
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Structural features (general/literature description):
Architecture: AB-type block copolymer with a hydrophobic PLLA block and a hydrophilic PEG block; Rhodamine B is covalently attached (commonly at one terminus of PEG in literature, exact attachment for this item not specified).
Blocks: “5000-5000” in the name typically denotes nominal number-average molecular weights Mn ≈ 5 kDa for each block (literature naming convention; not a specification for this item).
Functional groups: Ester linkages in PLLA backbone; ether linkages in PEG; xanthene dye core and carboxamide/ester features in RhB (literature, general to RhB).
Stereochemistry: PLLA segment derived from L-lactide (isotactic segments); PEG is achiral and flexible (literature, general).
2D structure in words (literature/general): A linear PEG chain covalently joined to a PLLA chain; a RhB fluorophore appended to one terminus yields an amphiphile with one fluorescent end and one biodegradable polyester segment.
Synthetic Utility
This product functions primarily as a pre-assembled amphiphilic polymer rather than a reactive building block. Without item-specific end-group information, no particular coupling chemistry can be recommended for this lot.
End-group functionality: Not specified for this item; refer to CoA/Spec Sheet. Literature variants of PLLA-PEG-RhB may feature methoxy-PEG termini or functional handles (e.g., NHS, maleimide) for bioconjugation, but these are not assumed here.
Utility in materials synthesis (literature/general):
Template and structure-directing agent for forming core–shell nanoparticles, hybrid inorganic–organic composites, or layer-by-layer films.
Component in block-copolymer blends to tune micelle size, critical micelle concentration, and mechanical properties of films.
Fluorescent tracer in process development (solvent casting, emulsification) to optimize mixing and solvent removal protocols.
Post-assembly modifications: While PEG corona can be derivatized in some systems, any such chemistry requires confirmed functional groups; otherwise, noncovalent loading of hydrophobes into the PLLA-rich core is the standard approach.
Analytical methods supporting synthetic use:
SEC/GPC for molecular weight and dispersity (with multi-angle light scattering if available).
UV–Vis/fluorescence to verify RhB integrity and quantify labeling per chain (using extinction coefficients determined for the specific solvent system).
FTIR/NMR to confirm block composition and to monitor PLLA hydrolysis during processing.
Target Specificity
Not an antibody, enzyme, or ligand with defined biological target specificity.
Antigen/epitope, species reactivity, clone, isotype: Not applicable.
Use the fluorescence label primarily for physicochemical tracking of assemblies or surfaces. Any biological interactions observed arise from colloidal properties (size, charge, corona) rather than specific binding to a defined target.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.