Determine the necessary mass, volume, or concentration for preparing a solution.
BioReagent, Colorimetry, Suitable for Analysis BioReagent,Colorimetry,Suitable for Analysis for sensitive chromatographic and analytical workflows requiring minimal baseline interference.
Store at 2-8°C,Protected from light Ships Wet ice,Do not freeze Check lot-specific COA for exact specifications.
SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.
Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.
Background Introduction:
The phenolic substances in the soil are mainly released by plants and produced by the decomposition of plant residues and fallen leaves. Due to the difficulty in their degradation, the accumulation of phenolic substances in the soil can affect the carbon-nitrogen transformation and greenhouse gas emissions of the soil, thereby causing a decline in soil fertility. Back. In addition, phenolic substances also have significant effects on the mineralization of soil organic matter and the nutrient cycle. This kit uses the Folin phenol method to determine the content of phenolic substances in the soil. Under alkaline conditions, phenolic substances will reduce tungsten molybdate, generating a blue compound. There is a characteristic absorption peak at 750 nm. By detecting the absorbance value at 750 nm, the content of phenolic substances in the soil can be calculated.
Components:
|
Required instruments and supplies:
Enzyme analyzer, 96-well plate, adjustable pipette, balance, centrifuge.
Determination of total phenolic content in soil:
It is recommended to select 2 samples for prediction before the formal experiment. This will help us understand the situation of this batch of samples, familiarize ourselves with the experimental process, and avoid waste of experimental samples and reagents!
1. Sample preparation:
Take approximately 0.5 g of soil sample, add 1 mL of extraction solution, and shake at room temperature for 30 minutes. Centrifuge at 25℃ and 8000 rpm for 10 minutes, then take the supernatant for testing.
2. Machine testing:
(1) The spectrophotometer was preheated for 30 minutes, the wavelength was adjusted to 750 nm, and distilled water was used for zero adjustment.
(2) Add successively in the 96-well plate:
|
Result Calculation:
1. Standard curve: Y = 0.2325*X + 0.04542, where X represents the mass of the standard sample (in μg) and Y represents ΔA.
2. Total phenol content in soil (μg/g soil) = (∆A - 0.04542) ÷ 0.2325 ÷ (V1 ÷ V × W) × D
V---Volume of the extracted liquid, 1 mL;
D---Dilution factor, 1 for undiluted sample;
V1---Volume of the sample in the reaction, 0.05 mL;
W---Mass of soil sample, g.

Appendix Procedure for preparing the standard curve:
1. Prepare standard stock solution (10 mg/mL): Add 1 mL distilled water to the standard powder vial, sonicate until fully dissolved.
2. Dilute the mother solution with distilled water to prepare five concentration gradients of standard samples: 0, 0.02, 0.04, 0.06, 0.08, 0.1 mg/mL. The concentration of the standard substance can also be adjusted according to the actual sample.
Operation Table (Take 50 μL of the standard solution stock solution, add 4.95 mL of distilled water, and mix well to obtain a 0.1 mg/mL standard dilution solution for later use):
|
3. Operate following the pipetting protocol for test tubes above, then plot the standard curve using recorded absorbance values.
| S1521998 | Components | Appearance | 48T | 96T | Storage | Quantity Per Test |
| S1521998A | Extraction Solution | Colorless clear liquid | 60 mL | 100 mL | 2-8℃. Store in the dark | 1 mL for 1 reaction |
| S1521998B | Reagent 1 | Yellow liquid | 7 mL | 14 mL | 2-8℃. Store in the dark | 125 μL for 1 reaction |
| S1521998C | Reagent 2 | Colorless clear liquid | 1.5 mL | 2.5 mL | 2-8℃ | 25 μL for 1 reaction |
| S1521998D | Standard Sample | White powder | 10 mg | 10 mg | 2-8℃ | Use as per requirements |
Comprehensive hazard, handling, storage, and regulatory compliance document.
Download SDS →Lot-specific quality data. Enter your lot number to retrieve the exact COA.
Look up COA →Full quality attributes and acceptance criteria for this grade.
View spec sheet →Find and download the COA for your product by matching the lot number on the packaging.
| Lot Number | Certificate Type | Date | Item |
|---|---|---|---|
| Certificate of Analysis | Aug 27, 2026 | S1521998 | |
| Certificate of Analysis | Aug 27, 2026 | S1521998 |
Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.
View BioReagent grade guide → View Suitable for Analysis grade guide → View Colorimetry grade guide →