StabilCoat™ Plus Stabilizer

Cat. No.: S573243
AVAILABLE TO ORDER
Storage
Store at 2-8°C
Shipped In
Wet ice
★
Size
Germany (EU)
USA*
Price
Qty
50ml
S573243-50ml
Made to order · 8–12 wks

€90.16

€105.78
Save €15.62 (14.77%)
Enter a quantity for the sizes you want to add.

Overview

Protein:Bovine

Specifications

Storage
Store at 2-8°C
Shipped In
Wet ice
This product requires cold chain shipping. Ground and other economy services are not available.
Names and Identifiers
PH
7.0 - 7.4

Advanced Data

Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Solution Calculators
Reviews

Customer Reviews

Application Protocols

No item-specific tested applications, dilutions, or protocols are provided in the Product Data.

General workflow outlines (not product-specific; validate in-house):

  • Plate coating preservation:
    1. Coat plates with capture protein in a suitable coating buffer; incubate per assay design.
    2. Aspirate and rinse as required.
    3. Add stabilizer to cover wells; incubate briefly to ensure contact; seal and store at 2–8°C.
    4. Before use, remove stabilizer and proceed with blocking and assay steps.
  • Conjugate storage:
    1. After purification, exchange conjugate into stabilizer using desalting/spin columns if compatible.
    2. Aliquot to minimize freeze–thaw; store at 2–8°C.
    3. Verify activity retention by periodic QC.
  • Low-adsorption handling:
    1. Pre-rinse tubes/tips with stabilizer.
    2. Maintain proteins at working concentration with stabilizer present to reduce surface losses.

For SKU S573243, consult the CoA/Spec Sheet or SDS for any manufacturer-recommended dilutions, compatible buffers, and specific cautions; these details are not specified here.

Biological Roles

This product is a research reagent designed to preserve the structural and functional integrity of biomolecules; it is not a biologically active therapeutic. No biological activity or target specificity is claimed.

General/literature context on stabilizers (not item-specific):

  • Protein stabilization: Osmolytes, sugars, and compatible polymers shift folding equilibria toward native states, reduce aggregation, and protect against interfacial denaturation (air–liquid, solid–liquid).
  • Adsorption suppression: Surface-active or hydrophilic excipients can limit nonspecific adsorption to plastics and glass, improving recovery of low-abundance proteins.
  • Enzyme and antibody preservation: Appropriate excipients can maintain catalytic activity and antigen-binding by moderating microenvironmental pH, ionic strength, and water activity, and by quenching reactive species.
  • Storage benefits: Stabilizers may mitigate degradation mechanisms such as deamidation, oxidation, and fragmentation indirectly by controlling conditions and minimizing stress; exact mechanisms depend on formulation.

For SKU S573243, no composition or performance specifications are provided; confirm empirical compatibility with your proteins and assays. This product is for research use only.

Buffer Applications

Highly relevant. While item-specific recipes are not disclosed, the following best practices apply when using aqueous stabilizers for immunoassays and protein storage. Treat as general guidance and validate for your system.

Common use cases (general/literature context):

  • Antibody/antigen coating: Dilute capture proteins in a recommended coating buffer, apply to plates/tubes, incubate to adsorb, then replace with stabilizer to preserve the coated surface during storage at 2–8°C. For this item, specific dilution factors and pH are not specified.
  • Conjugate storage: Maintain enzyme- or fluorophore-conjugated antibodies at 2–8°C in stabilizer to reduce activity loss and nonspecific adsorption. Avoid freeze–thaw unless validated.
  • Low-concentration handling: Add stabilizer to minimize losses on plastics, particularly below 1 µg/mL protein concentrations.

Practical tips:

  • Pre-rinse plastics with stabilizer or buffer containing stabilizer components to condition surfaces.
  • Confirm that the stabilizer does not inhibit downstream detection chemistry (e.g., HRP substrates, fluorescent readouts); run side-by-side controls.
  • If plates are to be stored long-term, verify microbial control and sealing. Preservative content for this product is not specified; check SDS.
  • Typical storage: 2–8°C per Product Data. Protect from contamination; use sterile technique where required.

Documentation: For any item-specific parameters (pH, ionic strength, recommended dilutions), consult the CoA/Spec Sheet for SKU S573243.

Green Alternatives

As an aqueous stabilizing formulation, this product is generally aligned with greener laboratory practices compared with organic solvent–rich systems. Nonetheless, greener choices relate to preservative selection, biodegradability, and waste minimization.

General sustainability considerations (not product-specific):

  • Solvent base: Water is preferred under green chemistry principles. Minimize addition of VOCs. If organic cosolvents are required for your biomolecule, choose lower-toxicity options (e.g., glycerol) where compatible.
  • Preservatives: Some formulations use isothiazolinones or azides; selection affects aquatic toxicity and metal compatibility. This product’s preservative content is not specified—consult SDS and choose disposal routes accordingly.
  • Waste reduction: Use concentrated formats if available, aliquot to reduce contamination and extend shelf life, and adopt recyclable plastics.
  • Energy: 2–8°C storage is less energy-intensive than frozen storage; avoid unnecessary freeze–thaw if not required by your protocol.

Illustrative comparison (literature context):

  • Simple buffers (PBS/TBS) vs aqueous stabilizers: Stabilizers may enable 2–8°C storage without freezing, reducing energy and dry ice shipments; verify performance for your system.
  • Organic-additive heavy formulations vs minimal additive systems: Lower additive loads reduce environmental impact but may offer less protection—balance performance with sustainability in validation.
Pharmaceutical Uses

This product is designated For research use only and is not intended for human or animal therapeutic or diagnostic applications.

General industry context (not product-specific):

  • In pharmaceutical development, stabilizers and excipients are used to preserve protein therapeutics during manufacture and storage (e.g., sugars, polyols, amino acids, surfactants, polymers). Such uses require GMP-grade materials and compendial compliance (USP/EP/JP), with rigorous quality attributes (bioburden, endotoxin, residual solvents, elemental impurities).
  • Typical excipient functions include cryo-/lyoprotection, adsorption suppression, and interface protection in vials/syringes.

Applicability to this item:

  • SKU S573243 has no stated GMP status or compendial listing. Grade/purity are not specified for this item; refer to CoA/Spec Sheet.
  • It should be limited to laboratory research workflows such as assay reagent stabilization and method development. For clinical or manufacturing use, source appropriate GMP/compendial materials and validate according to regulatory guidance.
Physical Properties

Only item-specific facts listed below are definitive; all other values are general/literature context and not product specifications.

Item-specific (from Product Data):

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Physical state: Expected to be an aqueous solution or concentrate, but composition/state is not disclosed. Not specified for this item; refer to CoA/Spec Sheet.

General/literature context for protein stabilizer formulations (not product-specific):

  • Typical matrix: Aqueous buffer systems in the pH 6–8 range to support protein stability and activity.
  • Possible excipients: Carbohydrates (e.g., sucrose, trehalose), polyols (e.g., glycerol), amino acids, polymers (e.g., dextran), and surfactants (e.g., nonionic) may be used in stabilizers; exact constituents for this product are not specified.
  • Density/refractive index: Generally similar to water when dilute; can increase with excipient concentration.
  • Solubility: Miscible with water; compatibility with organic solvents varies with composition. For this item, compatibility is not specified.

Do not treat the above general properties as specifications for SKU S573243. For exact parameters (pH, osmolality, conductivity, preservative content), consult the CoA/Spec Sheet.

Quality and Grades

Item-specific grade/purity are not provided in the Product Data.

  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
  • Intended use: For research use only (from Product Data). Not for diagnostic or therapeutic use.

General context for stabilizer grades (literature/industry, not product-specific):

  • RUO stabilizers are produced for laboratory workflows (e.g., ELISA, IHC, flow cytometry reagent storage) and may emphasize lot-to-lot consistency, low background, and compatibility with proteins and enzyme conjugates.
  • HPLC/LC-MS grades are typically defined for solvents, not stabilizer formulations. For stabilizers, quality is more often defined by functional performance (e.g., retention of antigen-binding activity, low nonspecific binding) and by analytical controls (pH, conductivity, microbial limits, bioburden/endotoxin for certain applications when specified).
  • Stabilizers sometimes include defined preservatives to limit microbial growth. Presence/absence and level of any preservative for this product are not specified; consult CoA/SDS.

Quality considerations when selecting a stabilizer:

  • Demonstrated compatibility with your target protein/enzyme and assay format.
  • Low assay background and minimal interference with detection chemistry.
  • Lot documentation (CoA) including key release tests relevant to your workflow.
Reaction and Applications

This product is not a synthetic reagent and is not typically used as a reagent in small‑molecule or organometallic transformations. Classic reaction families (e.g., cross-coupling, reductions, condensations) are not applicable.

Relevant laboratory applications (general/literature context, not product-specific claims):

  • Stabilization of capture/detection antibodies and antigens for immunoassays (ELISA, LFAs), helping maintain binding activity during storage and after coating on polystyrene surfaces.
  • Preservation of enzyme conjugates (e.g., HRP, AP) and fluorescently labeled proteins by minimizing denaturation and surface adsorption.
  • Reduction of nonspecific adsorption to plastics and glass during low-concentration handling and storage.
  • Support for shelf-life extension at 2–8°C by moderating chemical and physical degradation pathways (aggregation, oxidation, interface denaturation). Actual performance for this item is not specified.

Practical considerations:

  • Verify that the stabilizer does not interfere with assay chemistries (e.g., HRP/TMB, AP/PNPP, fluorescent readouts). Test small-scale before full workflow adoption.
  • Confirm compatibility with blocking agents and wash buffers in your platform.
  • Follow manufacturer CoA/SDS for any constraints on pH, ionic strength, or preservatives; these are not specified here for SKU S573243.
Reaction Conditions

Not directly applicable to classical chemical reactions. For biomolecule handling, consider the following general, non–product-specific guidance:

  • Temperature: Store and handle at 2–8°C as per Product Data unless assay protocols specify ambient equilibration. Avoid repeated freeze–thaw cycles unless validated for your protein.
  • pH/ionic strength: Use stabilizer within the pH and salt ranges compatible with your protein and assay; item-specific pH/salt for SKU S573243 are not specified.
  • Contact materials: Use low-bind plastics or precondition with stabilizer to reduce adsorption at low protein concentrations.
  • Filtration/sterility: If sterile handling is required, use sterile techniques and 0.22 µm filtration where appropriate. Verify that filtration is compatible with the formulation; composition is not specified for this product.
  • Additive interference: Before coupling reactions (e.g., NHS ester labeling) or enzymatic assays, confirm that the stabilizer does not contain amines, thiols, or surfactants that interfere. Composition for this item is not specified—perform pilot tests.
Safety and Handling

Authoritative safety information is found in the product SDS. In the absence of item-specific hazard statements, apply prudent laboratory precautions.

Item-specific:

  • GHS classification: Not specified for this item; refer to SDS.
  • Signal word/H-statements/Pictograms: Not specified for this item; refer to SDS.
  • Storage conditions: Store at 2–8°C (from Product Data). Shipped on wet ice.

General safe-handling guidance for aqueous stabilizer formulations (not product-specific):

  • PPE: Lab coat, safety glasses, and suitable chemical-resistant gloves. Avoid skin/eye contact and ingestion. Use in a well-ventilated area or biosafety cabinet if handling biological materials.
  • Incompatibilities: Avoid mixing with strong oxidizers or reactive chemicals until compatibility is confirmed. Some stabilizers may contain preservatives (e.g., azide, ProClin); verify SDS before using with azide‑sensitive metals or concentrated acids. This product’s preservative content is not specified.
  • First aid: Rinse skin/eyes with water for several minutes if contacted; remove contaminated clothing. Seek medical attention if irritation persists. If inhaled, move to fresh air. If ingested, rinse mouth and seek medical advice. Follow SDS instructions.
  • Spill/cleanup: Absorb with inert material, collect for disposal, and wash area with water. Prevent release to drains if the solution contains biocidal preservatives.

Always defer to the current SDS for SKU S573243 for definitive hazard, handling, and disposal guidance.

Solvent Selection

This product is a stabilizing solution/formulation rather than a solvent. Conventional solvent-selection frameworks (polarity, donicity, proticity) do not directly apply.

General guidance (literature context):

  • Matrix: Typically aqueous. When diluting or formulating with StabilCoat‑type reagents, use high-purity water (e.g., 18 MΩ·cm) or the recommended buffer to maintain conductivity, pH, and excipient balance. Item-specific diluent recommendations are not specified for this product; refer to CoA/Spec Sheet.
  • Miscibility/compatibility: Aqueous stabilizers are generally miscible with water and common biological buffers (PBS, TBS). Compatibility with high levels of organic cosolvents (e.g., >10–20% v/v MeOH, EtOH, DMSO) depends on composition and protein tolerance; evaluate empirically.
  • When to choose: Use an aqueous protein stabilizer to reduce denaturation, aggregation, and surface adsorption during storage, coating, or transport of antibodies/antigens and enzyme conjugates. If downstream steps require lyophilization or specific buffer constituents, ensure the stabilizer is compatible with those operations.

Brief comparison (general):

  • Simple buffers (PBS/TBS) offer pH control but limited stabilization against adsorption and freeze–thaw.
  • Additive-based stabilizers provide enhanced protection (osmolytes, polymers, surfactants) but must be screened for assay interference. The exact composition of this item is not specified; test compatibility with your readout chemistry.
Storage and Reconstitution

Item-specific storage is provided; reconstitution details and appearance are not.

  • Storage temperature: Store at 2–8°C (from Product Data).
  • Shipping: Shipped on wet ice (from Product Data).
  • Appearance/state: Not specified for this item; refer to CoA/Spec Sheet.
  • Reconstitution: Not specified for this item; refer to CoA/Spec Sheet. If provided as a concentrate or lyophilized format, follow the label instructions and use high-purity water or specified buffer.
  • Handling: Minimize contamination—work aseptically when sterility is required. Mix gently by inversion; avoid generating foam if the formulation contains surfactants (composition not specified).
  • Aliquoting: If frequent access is expected, aliquot into sterile containers to reduce contamination risk and extend shelf life at 2–8°C.
  • Freeze–thaw: Unless explicitly recommended by the manufacturer, avoid freezing to prevent phase separation or component precipitation; this product’s freeze stability is not specified.
  • Documentation: For shelf-life, pH, compatible diluents, and any preservative content, consult the current CoA/Spec Sheet and SDS for SKU S573243.

Research Use Note: For research use only (from Product Data).

Structure and Identity

Item-specific identifiers for this proprietary stabilizer are not disclosed. Where analytical identifiers are required for method validation or documentation, consult the product’s CoA/Specification Sheet.

  • Product type: Proprietary aqueous protein-stabilizing formulation intended to preserve antibodies/antigens and other biomolecules during coating, storage, and routine handling (general description; not item-specific composition).
  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
  • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
  • CAS: Not specified for this item; refer to CoA/Spec Sheet.
  • Structural features: As a formulation, it may comprise multiple stabilizing components (e.g., osmolytes, polymers, buffering salts) rather than a single defined small molecule (general literature context). No specific constituents are provided for this item.

2D structural description: Not applicable to a proprietary multi‑component stabilizer; individual constituent structures are not disclosed for this product.

Synthetic Utility

Not typically applicable. This product is a protein stabilizer formulation rather than a discrete reagent for synthetic organic or inorganic chemistry.

General notes for laboratory planning:

  • Do not substitute stabilizers for reaction solvents, bases, acids, or ligands. Their complex composition can unpredictably affect reaction outcomes.
  • If biomolecule conjugation chemistry is planned (e.g., NHS ester labeling, maleimide coupling), confirm that the stabilizer components do not contain competing nucleophiles or reducing agents that could quench reactive handles. For this item, composition is not specified—conduct small-scale compatibility tests or perform conjugation in defined buffers.
Target Specificity

Not applicable. SKU S573243 is a stabilizer formulation, not an antibody or affinity reagent. It has no antigen/epitope specificity, clone, isotype, or species reactivity. For immunoassay workflows requiring capture/detection specificity, pair this stabilizer with appropriate validated antibodies.

Frequently Asked Questions

How should this product be stored?
Store at 2–8 °C. Refrigerated storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.