ER-Tracker Red

Cat. No.: E745770
DISPONIBLE À COMMANDE
Storage
Protected from light,Store at -20°C
Shipped In
Ice chest + Ice pads
★
Taille
USA
Allemagne (EU)*
Prix
Qté
20μl
E745770-20μl
Fabrication sur commande aux États-Unis · 2–4 semaines ·
—

558,90$US

652,90$US
Enregistrer 94,00 $US (14.40%)
100μl
E745770-100μl
Fabrication sur commande aux États-Unis · 2–4 semaines ·
—

1 542,90$US

1 799,90$US
Enregistrer 257,00 $US (14.28%)
500μl
E745770-500μl
Fabrication sur commande aux États-Unis · 2–4 semaines ·
—

4 285,90$US

4 999,90$US
Enregistrer 714,00 $US (14.28%)
Enter a quantity for the sizes you want to add.
🧪
Pourquoi cette qualité

pour les flux de travail chromatographiques et analytiques sensibles nécessitant une interférence de ligne de base minimale.

🌡

Stockage & expédition

Protected from light,Store at -20°C Expédition Ice chest + Ice pads. Consultez le COA spécifique au lot pour les spécifications exactes.

📋

Documents qualité

SDS, COA, fiche technique et fiche de spécifications disponibles au téléchargement. COA spécifique au lot accessible via la recherche par numéro de lot.

📚

Preuve documentaire

Cité dans 0 publications à comité de lecture couvrant la chromatographie, la synthèse organique et les réactions de couplage croisé.

Vue d’ensemble

Precautions:

ER-Tracker Red (1mM) will solidify on ice or at lower temperatures such as 4℃ and stick to the bottom, walls or lid of the centrifuge tube. It should be thawed completely in a water bath at 20-25℃ prior to use. For trace amounts of liquid, centrifuge briefly before each use to collect the liquid at the bottom of the tube.Fluorescence intensity decays. Avoid light to minimize the quenching of fluorescence.Coverslips and slides are required but not supplied. They can be ordered from .The pharmacological activity of glibenclamide may affect some functions of the ER. Variable expression of sulfonylurea receptors in some specific cells may result in non-ER-specific staining.ER-Tracker Red is suitable for staining ER in live cells, but not ER in fixed cells. When cells stained with ER-Tracker Red need to be fixed, fix cells with 4% paraformaldehyde at 37℃ for 2 minutes.ER-Tracker Red stained cells cannot be permeabilized with Triton X-100 which will result in the loss of ER-Tracker Red fluorescent staining.This product is for R&D only. Not for drug, household, or other uses.For your safety and health, please wear a lab coat and disposable gloves during the operation.


Instructions for Use:

1.Preparation of ER-Tracker Red working solutiona.Dilute an appropriate amount of ER-Tracker Red (1mM) in the ER-Tracker Red Dilution Buffer at a ratio of 1:1000. For example, mix 1µl of ER-Tracker Red with 1ml of ER-Tracker Red Dilution buffer to obtain the ER-Tracker Red working solution.b.Prewarm the ER-Tracker Red working solution at 37℃ before use.Note: The dilution ratio of ER-Tracker Red can be adjusted within the range of 1:1000-1:3000 based on the staining results. To minimize the staining background, a lower concentration of ER-Tracker Red is preferred as long as an acceptable staining result can be obtained.2.Fluorescent labeling of ERa.Remove the cell culture medium and wash cells grown on coverslips with an appropriate amount of solution such as Hanks' Balanced Salt Solution with Ca2+ & Mg2+ (, C0219). For staining of suspension cells, centrifuge to collect cells and refer to the staining method for adherent cells .b.Remove the wash buffer, add the ER-Tracker Red working solution pre-incubated at 37℃, and incubate at 37℃ for 15-30 min.c. Remove the ER-Tracker Red working solution and wash cells 1-2 times with cell culture medium.d.Examine cells by fluorescence microscope or confocal microscope.e.If the ER-Tracker Red stained cells need to be fixed, fix with 4% paraformaldehyde for 2 min at 37℃. After fixation, wash cells 2-3 times with appropriate wash buffer for 5 minutes each, and then counterstain cells or mount cells with an appropriate antifade mounting medium. Note: ER-Tracker Red stained cells cannot be permeabilized with Triton X-100 which will result in the loss of ER-Tracker Red fluorescent staining.


Spécifications

Stabilité et stockage
Stored at -20 ℃, effective for six months. ER Tracker Red needs to be stored at -20 ℃ away from light.
Conditions de stockage de stockage
Protected from light,Store at -20°C
Expédié en
Ice chest + Ice pads
Ce produit nécessite l'expédition en chaîne froide. Les services terrestres et autres services économiques ne sont pas disponibles.
Product Line
Produits biologiques

Documentation

📋 Fiche de données de sécurité (FDS)

Document complet couvrant les dangers, la manipulation, le stockage et la conformité réglementaire.

<<<<<<< HEAD Télécharger la SDS → ======= Télécharger la SDS → >>>>>>> release248-p3

✅ Certificat d'analyse (COA)

Données qualité spécifiques au lot. Saisissez votre numéro de lot pour récupérer le COA exact.

Rechercher le COA →

📊 Fiche technique

Résumé de référence rapide des spécifications et applications du produit.

Voir la fiche technique →

🔬 Fiche de spécifications

Attributs de qualité complets et critères d'acceptation pour cette qualité.

Voir la fiche de spécifications →

Données avancées

Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
FAQ et articles
Calculateurs de solution
Avis

Avis des clients

Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?

Me rappeler plus tard

Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.

Oups ! Les notifications sont désactivées.