GNF-PF-3777 (8-Nitrotryptanthrin) is a potent human indoleamine 2,3-dioxygenase 2 (h IDO2 ) inhibitor which significantly reduces IDO2 activity with K i of 0.97 μM.
In Vitro
The typtanthrin derivative GNF-PF-3777 (8-Nitrotryptanthrin; Compound 5i) is found to be a potent hIDO2 inhibitor with superior efficiency far better than that of the most frequently-used inhibitor L-1-MT. The IC 50 values show that all nine tryptanthrin compounds display hIDO2 inhibitory activities, GNF-PF-3777 demonstrates much stronger inhibition (1.87 μM) than both L-1-MT (82.53 μM) and D-1-MT (262.75 μM). GNF-PF-3777 exhibits significant antitrypanosomal activity with EC 50 of 0.82 μM. GNF-PF-3777 (8-Nitrotryptanthrin) has a microplate Alamar Blue assay (MABA) minimum inhibitory concentration (MIC) value of 0.032 μg/mL. GNF-PF-3777 also has a LORA MIC value of 2.4 μg/mL, while the majority of analogues lack LORA activity. MCE has not independently confirmed the accuracy of these methods. They are for reference only.
GNF-PF-3777 (8-Nitrotryptanthrin) is a potent human indoleamine 2,3-dioxygenase 2 (h IDO2 ) inhibitor which significantly reduces IDO2 activity with K i of 0.97 μM.
Conditions de stockage de stockage
Store at -80°C
Expédié en
Dry ice packs + Cold packs
Ce produit nécessite l'expédition en chaîne froide. Les services terrestres et autres services économiques ne sont pas disponibles.
Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculateurs de solution
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Avis
Avis des clients
Application Protocols
Item-specific tested applications and dilutions:
Not specified for this item; no validated application protocols are provided.
General laboratory protocol (non-item-specific) for preparing screening stocks:
Weighing: Equilibrate vial to room temperature in a desiccator to avoid condensation. Tare a clean vial. Quickly transfer the required mass to minimize atmospheric moisture uptake.
Stock solution: Dissolve in anhydrous DMSO to 10–50 mM. Vortex and, if needed, sonicate gently. If incomplete dissolution, warm to 30–40°C and re-mix.
Sterile filtration (optional for cell assays): Filter through a 0.22 µm PTFE or PVDF syringe filter into a sterile, low-bind vial.
Aliquoting: Dispense single-use aliquots (e.g., 10–50 µL) into siliconized or low-bind tubes/plates to minimize adsorption and freeze–thaw.
Storage: Freeze aliquots at −80°C (per Product Data). Record lot number, concentration, solvent, date, and number of freeze–thaw cycles.
Assay dosing: Thaw on ice, briefly vortex. Add to assay to achieve desired final concentration with matched vehicle control; keep final DMSO ≤0.1–0.5% v/v unless assay supports higher.
Notes:
Validate solubility/clarity upon dilution. If precipitation occurs, reduce concentration, adjust cosolvent fraction, or modify dosing scheme (pre-dilute in media plus surfactant if compatible).
Biological Roles
Item-specific biological targets/roles:
Not specified for this item; refer to CoA/Spec Sheet and any linked database records (CAS 77603-42-0; CID 478573) for known annotations.
General context (for screening compounds; informational):
Screening library members may have annotated activities against enzymes, receptors, ion channels, or may be phenotypic modulators. Activities can be context-dependent and vary with assay system, isoform, and species.
Potential assay interferences include aggregation, fluorescence quenching/auto-fluorescence, redox cycling, covalent reactivity, and metal chelation. Employ orthogonal readouts, detergent controls, and redox/thiol scavengers as appropriate.
If pursuing target deconvolution after phenotypic hits, consider chemoproteomics (e.g., thermal proteome profiling), CRISPR-based modifier screens, CETSA, or affinity-based pull-downs with an immobilized analog—subject to the compound’s functional handles (not disclosed here).
Best practices:
Determine concentration–response curves across multiple assay formats to verify reproducibility and eliminate artifacts.
Assess basic ADME properties in vitro (permeability, metabolic stability, plasma protein binding) to contextualize cellular potency; these are general recommendations and not item-specific claims.
No clinical or therapeutic assertions are made for this product; it is for research use only.
Buffer Applications
Applicability:
This material is not a buffering agent. Buffer formulation is typically relevant only to dissolving and testing the compound in bioassays.
Practical assay-buffer guidance (general):
Choose buffers compatible with assay biology and detection technology: PBS (pH 7.2–7.4), HEPES (pH 6.8–8.2), or Tris (pH 7.0–9.0). Maintain ionic strength to support protein stability.
Keep final DMSO ≤0.1–0.5% v/v when diluting concentrated DMSO stocks to minimize solvent effects; match vehicle in all controls.
Use low-detergent buffers (e.g., 0.01–0.05% Tween-20 or 0.01% Triton X-100) to reduce colloidal aggregation artifacts if assay-tolerant.
For poorly soluble or sticky compounds, include carrier protein (0.1% BSA) or 0.05–0.1% pluronic to limit adsorption to plastics, validating that these additives do not perturb readouts.
Filter buffers (0.22 µm) and equilibrate to assay temperature. Verify compound stability in chosen buffer over assay time (co-incubate and re-measure by LC–MS or plate reader signal drift).
Item-specific buffer compatibility: Not specified for this item; consult CoA/Spec Sheet and perform small-scale compatibility checks.
Green Alternatives
Context:
For screening compounds, the primary sustainability lever is solvent choice during stock preparation, assay dilutions, and any synthetic modification steps. No item-specific solvent requirements are specified.
General greener choices and trade-offs (literature/practice):
| Use case | Conventional option | Greener alternative | Notes |
|---|---|---|---|
| Stock prep | DMSO | Retain DMSO (no broadly greener drop-in) | DMSO remains standard due to unmatched solvency and bio-compatibility; minimize volumes and wastage. |
| Cosolvent | DMF, NMP | Ethanol, isopropanol, acetonitrile (with care) | Improve safety profile; verify assay tolerance. |
| Synthesis | DMF, NMP, dichloromethane | 2-MeTHF, CPME, EtOAc, propylene carbonate | Evaluate solubility and reactivity; often effective for extractions and some couplings. |
| Chromatography | Hexane/DCM | Heptane/EtOAc, cyclopentyl methyl ether | Similar elution strength with better EHS profile. |
Operational tips:
Right-size batches and use miniaturized assay formats to reduce solvent consumption.
Implement solvent recycling where feasible (ACN/MeOH from LC, EtOAc/heptane from flash).
Prefer aqueous buffers and short contact times with organic solvents when preparing dilutions for biological assays.
Pharmaceutical Uses
Item-specific pharmacopeial status or excipient role:
Not specified for this item; no pharmacopeial monograph is provided. This product is supplied strictly for research use only and is not intended for human or veterinary administration.
General context (discovery-stage small molecules; informational only):
Screening compounds are typically used in early discovery to explore structure–activity relationships and identify leads. They are not manufactured under GMP nor qualified as APIs or excipients unless explicitly stated (not the case here).
For pre-formulation experiments (in vitro), solubilization strategies may include DMSO stock dosing, pH adjustment for ionizable molecules, and enabling excipients (cyclodextrins, PEGylated surfactants) in research settings—subject to assay compatibility.
If a compound advances, subsequent steps (salt selection, polymorph screening, stability studies) are undertaken under stringent quality systems; none of these claims apply to this catalog entry without further documentation.
Compliance note:
Do not use in clinical, diagnostic, or therapeutic applications. Handle and dispose per institutional research chemical policies.
Physical Properties
Item-specific values:
Not specified for this item; refer to CoA/Spec Sheet for: molecular weight, melting point, boiling point, density, refractive index, logP/logD, pKa, and aqueous/organic solubility limits.
General guidance (literature/practice for small-molecule screening solids):
Many screening compounds are crystalline or amorphous solids that are sparingly soluble in water and freely soluble in polar aprotic solvents (e.g., DMSO, DMF) and moderately soluble in alcohols (MeOH, EtOH).
Typical handling concentrations for DMSO stock solutions: 10–50 mM; working assay dilutions often achieve final DMSO ≤0.1–0.5% v/v to maintain biological system tolerance. These are general practices, not item specifications.
Practical notes:
If solubility data are absent, perform a small-scale solubility screen across DMSO, DMF, MeOH, EtOH, acetonitrile, and buffered aqueous media (with/without 0.1–1% v/v co-solvent). Warm (30–40°C) and vortex/sonication may aid dissolution.
Record pH-dependent solubility if the compound bears ionizable groups (unknown here). Use Good–Henderson rationale: acidic compounds often dissolve better at pH > pKa + 1; basic compounds at pH < pKa − 1. This is general guidance only.
Quality and Grades
Item-specific quality details:
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
General context for screening compounds (informational, not item-specific):
Typical QC for discovery compounds includes identity confirmation by LC–MS/HRMS and structural verification by 1H NMR (and 13C NMR as needed). Purity is commonly assessed by HPLC/UPLC with UV/ELSD, frequently targeting ≥90–95% area purity for screening libraries. Actual specification for this item must be taken from its CoA.
Trace residual solvents, water content (KF), and salts/counterions may affect potency or solubility; verify on the Spec Sheet if critical to your study.
If a stabilizer or salt form is present (e.g., HCl salt for amines), this will influence solubility and storage; none is stated here for this item.
Recommendations:
Prior to biological testing or SAR, independently confirm purity and identity (HPLC, LC–MS, NMR) to your lab’s acceptance criteria.
For quantitative work (e.g., IC50, KD), consider preparing calibration with analytical reference material if available, and document lot-to-lot comparisons.
Reaction and Applications
Applicability:
This product is supplied as a screening compound for discovery research rather than as a synthetic reagent. No item-specific synthetic applications are provided in the Product Data.
General research applications (non-item-specific):
Use as a test article in high-throughput screening (HTS), biochemical target assays, cell-based phenotypic assays, or probe validation studies.
Serve as a reference material or spike-in for method development in LC–MS quantitation if analytical response is characterized in-house.
If the compound is repurposed for synthesis (structure-dependent; not specified here):
Functional-group transformations, protection/deprotection, or conjugation (e.g., amide coupling, click chemistry) may be feasible depending on the scaffold. These possibilities are speculative without the disclosed structure; consult structural data first.
Best practices:
Confirm chemical identity and purity before biological evaluation.
Evaluate solubility/aggregation and redox stability to mitigate assay artifacts (e.g., PAINS, redox cyclers, metal chelators). Use orthogonal assays and counter-screens.
Maintain rigorous plate handling (edge effect controls, DMSO normalization) and document freeze–thaw history.
Reaction Conditions
Item-specific reaction conditions: Not applicable—this catalog entry is a screening compound and no synthetic transformations are specified for this item.
General guidance (if derivatization is pursued; non-item-specific):
Solvents: Select based on functional groups—polar aprotics (DMF, DMSO, NMP, ACN) for couplings; ethers or alcohols for reductions; greener options (2-MeTHF, EtOAc) where feasible.
Temperature: Start at ambient; escalate (40–80°C) as needed while monitoring stability by LC–MS. Avoid prolonged high temperatures for potentially labile heterocycles.
Catalysts/bases: For amide couplings, HATU/EDC with DIPEA/TEA; for cross-couplings, Pd catalysts (e.g., XPhos/Pd-2) with K3PO4 or Cs2CO3. These are general literature examples and not recommendations for this specific item.
Workup/purification: Favor minimal aqueous workups for highly lipophilic compounds; use reverse-phase prep-LC when normal-phase chromatography fails.
Note: All conditions above are generic and should only be applied after confirming the compound’s structure and stability profile.
Safety and Handling
Item-specific hazard information:
Signal Word: Not specified for this item; refer to SDS.
H-Statements: Not specified for this item; refer to SDS.
GHS Classification: Not specified for this item; refer to SDS.
Pictograms: Not specified for this item; refer to SDS.
General safety guidance (non-item-specific; defer to SDS for authoritative data):
Handle unknown small molecules as potentially harmful. Avoid inhalation, ingestion, and skin/eye contact. Use appropriate PPE: lab coat, safety glasses, and disposable nitrile gloves; upgrade to double-gloving and splash protection when weighing powders or preparing concentrated stocks.
Work in a fume hood during weighing and solution prep to control dust/aerosols and solvent vapors (e.g., DMSO, DMF).
Storage incompatibilities: Keep separate from strong oxidizers, strong acids/bases, and reducing agents unless compatibility is known. Protect from light and moisture as prudent practice for heteroaromatics or halogenated scaffolds (structure not provided).
First aid (general): In case of skin/eye contact, rinse with water for ≥15 minutes; remove contaminated clothing. If inhaled, move to fresh air. If ingested, rinse mouth; do not induce vomiting; seek medical attention. Always follow your institution’s EHS procedures.
Waste: Collect solid and solution waste in halogenated organic waste or appropriate container per solvent matrix; label clearly. Decontaminate surfaces with suitable solvent and detergent.
Special risks: Many screening compounds may be bioactive; minimize exposure and avoid environmental release.
Solvent Selection
Item-specific solubility/solvent compatibility: Not specified for this item; refer to CoA/Spec Sheet.
General guidance for dissolving small-molecule screening compounds (literature/practice):
Primary solvent: DMSO is the default due to broad solubilizing power and biological compatibility at ≤0.1–0.5% v/v in assays.
Alternative polar aprotics: DMF and NMP improve solubility for very lipophilic or H-bonding compounds but may be less cell-compatible.
Protic solvents: MeOH/EtOH can aid dissolution and co-solvency with aqueous buffers; limit to ≤1–2% v/v in sensitive assays.
Aqueous media: Use buffer systems matched to assay pH (e.g., PBS, HEPES, Tris). Surfactants (0.01–0.05% Tween-20 or Pluronic F-68) can mitigate aggregation, if assay-tolerant.
Practical tips:
Start with a concentrated DMSO stock (e.g., 10–50 mM), then serially dilute into medium/buffer with vigorous mixing to avoid precipitation.
Pre-wet plasticware with buffer or 0.1% BSA when dealing with sticky/hydrophobic compounds to reduce adsorption.
Verify clarity after dilution; if haze forms, increase dilution factor, add a small co-solvent fraction (ACN/EtOH), or gently warm to 30–37°C.
Brief comparison (general):
DMSO: best breadth; high boiling point; hygroscopic.
ACN/EtOH: fast mixing, volatile; better for MS workflows.
2-MeTHF/CPME: greener for synthesis, not typically used for bioassay dosing.
Storage and Reconstitution
Item-specific instructions (from Product Data):
Storage Conditions: Store at −80°C.
Shipped In: Dry ice packs + Cold packs.
Additional item-specific details:
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Stabilizers/solvent: Not specified for this item; refer to CoA/Spec Sheet.
General best practices (non-item-specific):
Upon receipt: Keep vial frozen. Allow to warm in a desiccator to room temperature before opening to prevent condensation on a cold solid.
Reconstitution: Prepare concentrated stock in dry DMSO (typical 10–50 mM) unless the Spec Sheet indicates different solvent preferences. Record exact concentration gravimetrically or by UV if chromophore permits (extinction coefficient would be structure-dependent and is not provided here).
Aliquoting: Create single-use aliquots in low-bind tubes to avoid repeated freeze–thaw; purge headspace with inert gas (N2/Ar) if oxidation is a concern (structure not disclosed).
Storage of solutions: Store DMSO stocks at −80°C, protected from light. Avoid more than 2–3 freeze–thaw cycles; discard aliquots showing discoloration or precipitation that does not redissolve.
Stability: Not specified for this item; consult CoA/Spec Sheet and verify by periodic LC–MS/HPLC.
Note: All handling must adhere to your institution’s chemical hygiene plan. For definitive stability, impurities, and reconstitution solvent guidance, rely on the product’s CoA/Spec Sheet.
Structure and Identity
Concise overview: This listing is for a small-molecule screening compound designated GNF-PF-3777, supplied for research use.
Item-specific (from Product Data):
SKU: G655978
Product Name: GNF-PF-3777
CAS: 77603-42-0
PubChem CID: 478573
Storage: Store at −80°C
Shipped on: Dry ice packs + Cold packs
Intended use: For research use only
Not specified for this item; refer to CoA/Spec Sheet:
Molecular formula
Molecular weight
SMILES
InChIKey
Stereochemistry, functional groups, and structural class
General notes (chemistry background):
Without a disclosed structure, specific functional groups, ring systems, or stereocenters cannot be described for this catalog entry. The CAS and CID identifiers enable cross-referencing in public databases; consult the Certificate of Analysis (CoA) or Spec Sheet for definitive identity attributes, including spectral data (1H/13C NMR, LC–MS, HRMS) and purity.
For screening collection compounds, suppliers commonly confirm identity by LC–MS and purity by HPLC; however, these are general practices and not item-specific. Always verify against the item’s CoA.
Synthetic Utility
Applicability:
This product is offered as a screening compound rather than a building block. No item-specific functional group information is provided; synthetic applications cannot be assigned without the disclosed structure.
General considerations (informational):
If the scaffold contains common handles (e.g., aryl halide, anilide, nitrile, carboxylate, alkyne/azide), it could in principle undergo cross-coupling, hydrolysis, reduction/oxidation, or click conjugation to generate analogs or linkers. Such possibilities are structure-dependent and speculative here.
For tag installation (biotin, fluorophores) in probe development, amide coupling (HATU/EDC), CuAAC, or SuFEx are typical routes if compatible handles are present.
Recommendations:
Obtain and review the structural data (CoA/Spec Sheet) before planning any synthetic modification.
Perform small-scale scouting reactions with analytical monitoring (LC–MS) to confirm reactivity and stability.
If salt form or tautomeric state is unknown, determine by NMR/HRMS first to avoid misassignments in derivatization campaigns.
Target Specificity
Item-specific data:
Not specified for this item; no validated molecular target(s), binding constants, or selectivity profiles are provided in the Product Data. Consult CoA/Spec Sheet or primary literature associated with CAS 77603-42-0 / CID 478573 if available.
General guidance (for hit characterization; informational):
Use orthogonal assays (biochemical vs. cellular) to confirm activity.
Profile counterscreens against close homologs/isoforms to assess selectivity.
Evaluate off-target liabilities (CYP inhibition, hERG, kinome panels) early in discovery to avoid assay artifacts or safety flags.
Consider target engagement assays (CETSA, NanoBRET, SPR, ITC) for mechanistic validation when feasible.
Foire aux questions
How should this product be stored?
Store at ?80 °C. Ultra-low temperature storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships frozen with dry ice and cold packs. Unpack on arrival and transfer it to the storage condition stated above; handle dry ice with insulated gloves in a ventilated area.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 77603-42-0, the molecular formula is C15H7N3O4, and the molecular weight is 293.23 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Nous utilisons des cookies pour garantir le bon fonctionnement du site et, lorsque cela est autorisé, pour améliorer votre expérience. Vous pouvez gérer vos préférences à tout moment dans les Paramètres. Pour en savoir plus, consultez notre Politique relative aux cookies.
Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?
Me rappeler plus tard
Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.