NXP800 - Moligand™, 10mM in DMSO , CAS No.1693734-80-3

CAS: 1693734-80-3 Cat. No.: N656606 Formule: C32H32FN5O4 Poids moléculaire: 569.63 Numéro CE: 891-238-1
DISPONIBLE À COMMANDE
QUALITÉ & PURETÉ Moligand™ ? Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools. 10mM in DMSO
Storage
Store at -80°C
Shipped In
Dry ice packs + Cold packs
★
Taille
USA
Allemagne (EU)*
Prix
Qté
1ml
N656606-1ml
Sur commande · 8–12 semaines
315,90$US
Enter a quantity for the sizes you want to add.

Vue d’ensemble

NXP800 (CCT361814) is a potent and orally active heat shock factor 1 (HSF1) pathway inhibitor. NXP800 has the potential for cancer research

In Vitro

NXP800 (example 169) inhibits U20S cells viability (IC 50 =0.056 μM). MCE has not independently confirmed the accuracy of these methods. They are for reference only.

In Vivo

NXP800 (35 mg/kg; po; once daily for 20 days) inhibits the established SK-OV-3 human ovarian cancer solid tumor xenografts grown subcutaneously, with tumor growth inhibition (TGI) of 120% relative to control. Pharmacokinetic AnalysisSpecies Route Dose (mg/kg) T max (h) AUC last (ng·h/mL) Cl tb (mL/min/kg) t 1/2 (h) F (%) AUC u 0-t (h·nM) Free C av 0-24h (nM) Cl u (mL/min/kg) mouse po/iv 5/5 2.0 6000 (7800-4600) (po) 10 (10-9.7) (iv) 4.0 42 (po) 72 3.3 830 (iv) rat po/iv 5/1 6.0 2600 (po) 24 (iv) 3.1 45 (po) 86 3.7 730 (iv) dog po/iv 2.5/0.5 2.0 250 (po) 21 (iv) 1.4 9.1 (po) 35 1.9 150 (iv) MCE has not independently confirmed the accuracy of these methods. They are for reference only.

IC50& Target:HSF1

Spécifications

Spécifications et pureté
Moligand™, 10mM in DMSO
Mécanismes biochimiques et physiologiques
NXP800 (CCT361814) is a potent and orally active heat shock factor 1 (HSF1) pathway inhibitor. NXP800 hasxa0thexa0potentialxa0forxa0cancer research.
Conditions de stockage de stockage
Store at -80°C
Expédié en
Dry ice packs + Cold packs
Ce produit nécessite l'expédition en chaîne froide. Les services terrestres et autres services économiques ne sont pas disponibles.
Grade
Moligand™
Type d'action
INHIBITOR
Noms et identifiants
Poids moléculaire
569.63

Données avancées

Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculateurs de solution
Avis

Avis des clients

Application Protocols
  • Item-specific (from Product Data)

    • Tested applications, recommended dilutions, and positive controls: Not specified for this item; refer to CoA/Spec Sheet.
  • General small-molecule handling protocols

    • Stock solution: Dissolve in anhydrous DMSO to 10–50 mM. Aliquot (single-use) into low-bind tubes and store at -80°C.
    • Thawing: Warm briefly to room temperature, vortex to ensure homogeneity, and immediately return unused aliquots to -80°C. Avoid repeated freeze–thaw cycles.
    • Working solutions: Prepare fresh on the day of use. For cell assays, titrate concentrations spanning ≥8–10 points (e.g., 0.03–30 µM) to generate robust CRCs; keep vehicle constant across wells.
    • Analytics: Verify concentration by LC/UV or qNMR if potency/PK studies demand accuracy. Inspect for precipitation/turbidity after dilution into assay media.
    • Documentation: Record lot number, stock concentration, solvent, preparation date, and storage conditions in ELN/LIMS.
Biological Roles
  • Item-specific (from Product Data)

    • No target, pathway, or mechanism information is provided for NXP800.
  • Scope statement

    • Without disclosed structure or target annotation, specific biological roles cannot be assigned to this item. Any functional characterization should be derived from your in-house screening data or primary literature tied unambiguously to this CAS.
  • General research uses (non-clinical)

    • Can be evaluated as a tool compound in phenotypic or target-based assays, ADME profiling (microsomal stability, permeability, plasma protein binding), and selectivity panels.
    • Early triage experiments: solubility in assay media, chemical stability (pH 2–9), redox stability, and photostability. Establish a clean concentration–response with appropriate vehicle controls.
  • Documentation

    • Record batch/lot, preparation date, solvent, and storage history to correlate biological readouts with material quality. Validate integrity periodically by LC/MS.
Buffer Applications

This item is not a buffer component per se. Guidance below focuses on preparing assay-compatible solutions of small molecules.

  • Stock preparation (general)

    • Dissolve in anhydrous DMSO to 10–50 mM. Filter through 0.2 µm PTFE if particulates are present (avoid adsorption-prone membranes for lipophilic compounds).
    • For aqueous assays, dilute into buffer (e.g., PBS, HEPES, Tris) under strong mixing; target final DMSO ≤0.5–1% v/v for cells, ≤2% for many biochemical assays (confirm assay tolerance).
  • Precipitation control

    • Prepare intermediate cosolvent mixtures (e.g., 50% ACN/H2O or MeOH/H2O) before final dilution to reduce crash-out.
    • Warm gently (≤37–40°C) and sonicate briefly if needed. Avoid pH adjustments unless ionizable groups are known.
  • Adsorption and loss

    • To limit nonspecific binding, use low-bind polypropylene tubes and add carrier protein (e.g., 0.1% BSA) only if compatible and after establishing it does not affect the readout.
  • Verification

    • Inspect for turbidity after dilution and confirm concentration via LC/UV or qNMR when extinction coefficients are unknown.
Green Alternatives

Green chemistry considerations are generally less applicable to finished library compounds than to bulk solvents and reagents. Nonetheless, solvent and handling choices can reduce environmental impact.

  • Not item-specific; general guidance

    • Prefer greener solvents for dissolution and work-up when possible: ethanol or isopropanol for benign extraction/cleaning steps; acetonitrile or methanol (over chlorinated solvents) for LC workflows where compatible.
    • Avoid DMF/DMAc/NMP when DMSO or alcoholic solvents suffice for stock preparation.
    • Minimize DMSO waste by preparing concentrated aliquots and diluting at point-of-use; consolidate waste streams for appropriate disposal.
  • Example comparison (general)

    • Ethanol vs. DCM: ethanol is less hazardous and more sustainable but may have lower solvency for highly lipophilic compounds.
    • 2-Propanol vs. acetonitrile: greener but higher viscosity and different elution strength; may not substitute in LC methods without retuning.
  • Operational practices

    • Use microscale assays and miniaturized plates to reduce solvent consumption.
    • Store at recommended low temperatures to extend shelf-life and minimize repeat syntheses and shipments.
Pharmaceutical Uses
  • Item-specific (from Product Data)

    • Research Use Only. No medical or clinical use is intended or implied.
  • Context (general, non-clinical)

    • Compounds of this type may be used as reference materials, assay controls, or starting points for medicinal chemistry in preclinical research. Any excipient roles, compendial status, or formulation functions are not specified for this item and should not be assumed.
  • Formulation in research settings (general guidance)

    • Prepare concentrated DMSO stocks and dilute into suitable vehicles (e.g., PEG400/saline, Captisol, or acidified/surfactant-containing systems) for in vivo exploratory studies, subject to institutional approvals and safety review. Verify solubility and stability; avoid precipitation at the point of administration.
  • Compliance note

    • For GLP/GMP or regulatory workflows, obtain a detailed CoA/Spec Sheet, impurity profile, and stability data. This product is not certified for human or veterinary use.
Physical Properties
  • Item-specific (from Product Data)

    • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • Typical physicochemical parameters (literature/general guidance; not item-specific)

    • Without a disclosed structure, properties such as melting point, boiling point, density, logP/logD, pKa, refractive index, and aqueous solubility cannot be assigned. These must be obtained from the CoA/Spec Sheet or determined experimentally.
  • Practical guidance (general chemistry knowledge)

    • Initial solubility screening: DMSO (anhydrous) at 10–50 mM stock is commonly used for small-molecule libraries; confirm clarity and absence of precipitation upon dilution into assay buffer.
    • If salt form is unknown, titrate a small portion in mixed solvents (e.g., DMSO, DMF, MeOH, 1:1 DMSO:H2O) to identify a workable vehicle.
    • For hygroscopic or polymorphic materials, record any observed deliquescence or phase changes upon exposure to ambient humidity; store promptly per guidance in Storage & Reconstitution.
    • If UV methods are used for quantification but ε (molar absorptivity) is unknown, favor gravimetric or quantitative NMR (qNMR) for concentration determination.
Quality and Grades
  • Item-specific (from Product Data)

    • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
  • Interpreting grade and documentation (general guidance)

    • For screening compounds and library members, vendors typically provide purity by HPLC/UPLC (area %) and identity by MS/HRMS (and sometimes 1H NMR). Confirm acceptance criteria on the CoA (e.g., ≥95% by HPLC) before use in SAR or biological assays.
    • If a stabilizer or counterion is present (not specified for this item), it should be declared on the CoA; account for this in molecular weight calculations and solution preparation.
    • For LC/MS-driven workflows, low non-volatile impurity content (salts, buffers) is preferred. If residual solvents are a concern, check the residual solvent profile on the CoA.
    • If UV transparency is critical (e.g., photochemical studies), request a UV-Vis spectrum or evaluate in-house, as low-level chromophores or impurities can influence assay baselines.
Reaction and Applications

This product is offered as a small-molecule library compound/tool, not as a synthetic reagent or solvent.

  • Item-specific (from Product Data)

    • Category: Small molecules and compound libraries (全部 / 可售 / 小分子和化合物库).
  • Applicability (honest scope)

    • Not typically used as a reagent, catalyst, or bulk solvent. Therefore, discussions of named-reaction performance, cross-coupling scope, or reagent-specific transformations do not apply here without structural information.
  • Practical research applications (general, non-clinical)

    • Suitable for target-agnostic screening, hit confirmation, orthogonal assay development, and reference control in biochemical/cell-based assays.
    • Can be profiled for physicochemical properties (solubility, stability in buffer/sera, microsomal stability) to inform follow-up SAR.
    • For analytical chemistry: serve as an internal/external standard in method development if purity and extinction/conductivity permit (verify via CoA and in-house QC).
  • Tips

    • Verify identity and purity (HPLC, MS, 1H NMR) before mechanistic biology or SAR decisions.
    • Prepare aliquoted DMSO stocks to avoid freeze–thaw degradation; document any observed time-dependent precipitation or color change.
Reaction Conditions

Not applicable in the usual sense: NXP800 is provided as a screening compound/tool rather than a reagent. No reaction condition data are provided for this item.

  • General guidance (if modification is undertaken post-structure disclosure)

    • Select conditions based on the known functional groups; begin with chemoselective transformations and mild conditions to preserve scaffold integrity.
    • Use microscale scouting (0.5–5 mg) to probe solubility and stability across solvent systems (MeCN, MeOH, DCM, toluene, 2-MeTHF) and temperatures (rt to 60°C) before scale-up.
    • Monitor by LC/MS for degradants; collect stability-indicating chromatograms in relevant media (pH 2, 7.4, 9) and common organic solvents.
  • Yield/kinetics

    • No literature values can be provided without structural information; consult primary references once the scaffold is identified.
Safety and Handling
  • Item-specific (from Product Data)

    • GHS Classification: Not specified for this item; refer to SDS.
    • Signal word / H-statements / Pictograms: Not specified for this item; refer to SDS.
    • Storage conditions: Store at -80°C.
    • Shipping: Dry ice packs + cold packs.
  • General safety guidance (defer to SDS for authoritative information)

    • Handle unknown small molecules in a chemical fume hood with appropriate PPE: lab coat, safety glasses, and nitrile gloves; consider double-gloving for DMSO stocks due to dermal transport potential.
    • Avoid inhalation of dust/aerosols; minimize skin contact; prevent ingestion.
    • Incompatibilities are structure-dependent; as a precaution, segregate from strong oxidizers and acids/bases until specific data are available.
    • First aid (general): If on skin, wash with soap and water; if in eyes, rinse cautiously for several minutes; if inhaled, move to fresh air; if ingested, rinse mouth. Seek medical attention if symptoms occur.
    • Spill response: Absorb liquids with inert material; pick up solids with dampened disposable wipes to minimize dusting. Dispose as organic laboratory waste per institutional and local regulations.
    • Fire fighting: Use CO2, dry chemical, or foam; combustion products unknown—firefighters should wear self-contained breathing apparatus.
Solvent Selection
  • Item-specific (from Product Data)

    • No solvent preferences are specified for this item; refer to CoA/Spec Sheet.
  • Practical selection for unknown small molecules (general chemistry knowledge)

    • Primary vehicles: DMSO (anhydrous) is the default for 10–50 mM stocks. For immediate use, N,N-dimethylformamide (DMF) or ethanol can be alternatives if compatible with the assay.
    • Aqueous delivery: Dilute DMSO stocks into buffered saline (e.g., PBS, HEPES, or assay-specific media) under vigorous mixing to avoid local supersaturation; final DMSO typically ≤0.5–1% v/v for cell-based assays.
    • Low-polarity options (for analytics/preparative work): Acetonitrile, methanol, isopropanol for LC; ethyl acetate, MTBE, dichloromethane for extractions (observe safety and waste rules).
    • Troubleshooting solubility: Use co-solvent blends (e.g., 30–60% ACN/H2O or MeOH/H2O), slight warming (≤40°C), or sonication. Avoid high pH/strong base unless salt form/functional groups are known.
  • Small comparison (general)

    • DMSO: maximal solvating power; may affect biology; strong skin penetration.
    • DMF: good solvency; more toxic; less preferred in bioassays.
    • Ethanol/IPA: biocompatible at low %; lower solvency for highly lipophilic compounds.
Storage and Reconstitution
  • Item-specific (from Product Data)

    • Storage: Store at -80°C.
    • Shipping: Dry ice packs + Cold packs.
  • Reconstitution (general guidance for small molecules)

    • Preferred solvent: Anhydrous DMSO. Prepare concentrated stocks (e.g., 10–50 mM) to minimize freeze–thaw and solvent volume in assays.
    • Aliquoting: Dispense into single-use, low-bind polypropylene vials under dry, inert conditions if feasible (desiccator or glovebox) to limit moisture uptake.
    • Thaw/minimize degradation: Thaw quickly at room temperature, vortex to fully dissolve, and use immediately. Refreeze unused aliquots once; avoid multiple freeze–thaw cycles.
  • Stability considerations (not item-specific)

    • Protect from light if chromophores are suspected; store desiccated. Track stability by periodic LC/MS or HPLC purity checks.
    • For aqueous solutions, use immediately or store short-term at 2–8°C (hours to a day) depending on observed stability; long-term storage of aqueous solutions is not recommended without supporting data.
  • Record keeping

    • Maintain logs of aliquot preparation date, concentration, and storage location. Always defer to the CoA/Spec Sheet and SDS for any item-specific stability or incompatibility notes.
Structure and Identity

Brief overview: NXP800 is listed as a small-molecule library member. No structural identifiers are provided in the product data.

  • Item-specific (from Product Data)

    • Product name: NXP800 (SKU: N656606)
    • CAS: 1693734-80-3
    • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
    • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
  • Structural features

    • Not specified for this item; refer to CoA/Spec Sheet. No ring system, functional group, or stereochemical information has been provided.
  • Practical note (general chemistry knowledge)

    • For uncharacterized screening compounds, structure verification (NMR, HRMS) and identity confirmation against the CoA are recommended prior to critical studies.
    • If the compound is supplied as a solid or film, confirm salt form (free base/acid vs. salt) on the CoA, as this impacts solubility and molecular weight for dosing calculations.
Synthetic Utility

This product is supplied as a finished small molecule rather than a building block or reagent.

  • Applicability

    • Without structural information (functional groups, handles), discussion of reactivity, protecting-group strategies, or named transformations is not appropriate for this item.
  • Practical notes (general)

    • If derivatization is planned (e.g., for probe development or bioconjugation), obtain the full structure and assess feasible attachment points; confirm that IP and licensing allow modifications.
    • For analytical derivatization (e.g., isotope labeling for PK standards), validate stability and chromatographic behavior of both parent and derivative.
  • Recommendation

    • Use this item for biological/analytical evaluation. Source or synthesize dedicated intermediates for SAR exploration once structural information is available.
Target Specificity
  • Item-specific (from Product Data)

    • Target, mechanism of action, and selectivity profile: Not specified for this item; refer to CoA/Spec Sheet or primary literature explicitly linked to CAS 1693734-80-3.
  • Guidance (general)

    • Establish target engagement using orthogonal assays (biochemical potency vs. cell-based reporter/phenotype), and evaluate off-target risks via panel screening when applicable.
    • If used as a tool compound, include inactive analogs and perform counter-screens to deconvolute assay interference (e.g., redox cycling, aggregation). Employ detergent controls and light/dye interference assessments where relevant.

Besoin d'aide pour choisir la qualité ?

Notre guide de sélection des qualités couvre la pureté, le statut du stabilisant et l'adéquation à l'application pour toutes les variantes de notre catalogue.

Voir le guide des qualités Moligand™ →

Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?

Me rappeler plus tard

Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.

Oups ! Les notifications sont désactivées.