Peroxide Value Assay Kit (Micro Method)

Cat. No.: P1522268
DISPONIBLE À COMMANDE
QUALITÉ & PURETÉ BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Taille
USA
Allemagne (EU)*
Prix
Qté
96T
P1522268-96T
Sur commande · 8–12 semaines
139,90$US
Enter a quantity for the sizes you want to add.
🧪
Pourquoi cette qualité

BioReagent BioReagent pour les flux de travail chromatographiques et analytiques sensibles nécessitant une interférence de ligne de base minimale.

🌡

Stockage & expédition

Store at 2-8°C,Protected from light Expédition Wet ice. Consultez le COA spécifique au lot pour les spécifications exactes.

📋

Documents qualité

SDS, COA, fiche technique et fiche de spécifications disponibles au téléchargement. COA spécifique au lot accessible via la recherche par numéro de lot.

📚

Preuve documentaire

Cité dans 0 publications à comité de lecture couvrant la chromatographie, la synthèse organique et les réactions de couplage croisé.

Vue d’ensemble

Peroxide value is an important indicator of the degree of oxidation of oils, fats, and fatty acids, usually expressed as millimoles of active oxygen per kilogram of sample. It is used to determine whether food has deteriorated due to oxidation and is a key parameter for evaluating food hygiene quality. The higher the peroxide value, the more severe the rancidity of the oil, and the lower the quality and safety of the food.

Principle: Peroxides in the sample oxidize ferrous ions (Fe²⁺) to ferric ions (Fe³⁺). Ferric ions react with thiocyanate to form an orange-red ferric thiocyanate complex. The peroxide value can be determined by measuring the absorbance of this complex at 500 nm.

Contents & Storage:

Component No.Component NameAppearance96TStorage
P1522268AReagent ILiquid1EA2-8℃. Store in the dark
P1522268BReagent IIPowder1EA2-8℃. Store in the dark
P1522268CStandardLiquid2mL2-8℃. Store in the dark

Precautions for Reagent Use:

1.Before opening Reagent II, ensure the powder has settled to the bottom (shake manually). When using, dissolve in 1.2 mL of pure water. The storage period is the same as the kit's shelf life.

2.Extraction solution must be prepared by the user. Pure methanol (analytical grade or higher, purity ≥98%) is recommended.

Experimental Equipment:

Mortar (homogenizer), ice box (ice machine), benchtop centrifuge, adjustable pipette, 96-well plate, centrifuge tubes, microplate reader, pure methanol, distilled water (deionized water or ultrapure water are all acceptable).

Measurement Procedure:

It is recommended to first select 1–3 samples with large differences (e.g., different types or groups) for a preliminary experiment to familiarize yourself with the procedure and determine or adjust the sample concentration based on the preliminary results, so as to avoid unnecessary waste of samples or reagents.

1. Sample Extraction:

① Animal and plant tissue samples:

Take approximately 0.1 g of tissue, add 1 mL of extraction solution, and homogenize in an ice bath. Centrifuge at 12,000 rpm at 4°C for 10 min. Collect the supernatant and keep it on ice until measurement.

② Liquid samples:

Measure directly. If turbid, centrifuge and use the supernatant for detection.

③ Bacterial/cell samples:

First collect the bacteria or cells into a centrifuge tube, centrifuge, and discard the supernatant. Take 5 million bacteria or cells, add 1 mL of extraction solution, and homogenize in an ice bath (various common electric homogenizers may be used); alternatively, use an ultrasonic disruptor to sonicate the bacteria or cells in an ice bath (power 200 W, sonication 3 s, interval 10 s, repeat 30 times). Centrifuge at 12,000 rpm at 4°C for 10 min and collect the supernatant for measurement.

[Note]: Cell samples may also be lysed with a lysis buffer for subsequent detection; the lysis method should follow the lysis buffer's operating instructions.

2. Detection Steps:

① Preheat the microplate reader for 30 min (waiting for the instrument to complete its self-check procedure is also acceptable), and set the wavelength to 500 nm.

② Bring all reagents to room temperature, and add them sequentially to EP tubes as shown in the table below:

Reagent (μL)Assay TubeBlank Tube (once only)
Sample50—
Pure methanol900950
Reagent I1010
Reagent II1010

Mix well and incubate at room temperature for 5 min. Transfer 200 μL to a 96-well plate and measure the absorbance (A) at 500 nm.ΔA = Aassay − Ablank.

[Note]: 

1. If the value of the assay tube (A) exceeds 1.8, the sample may be diluted before measurement; the dilution factor D should be substituted into the calculation formula.

2.If ΔA is less than 0.01, the sample mass W may be increased; the changed W must be substituted into the formula for recalculation.

Result Calculation:

Standard curve equation: y = 0.0055x − 0.0165, where x is the standard concentration (μg/mL) and y is ΔA.

1.Calculation based on mass:

Peroxide value (μg/g) = [(ΔA + 0.0165) ÷ 0.0055 × V₁] ÷ (W × V₁ ÷ V) × D= 181.82 × (ΔA + 0.0165) ÷ W × D

2.Calculation based on protein content:

Peroxide value (μg/mg prot) = [(ΔA + 0.0165) ÷ 0.0055 × V₁] ÷ (Cpr × V₁ ÷ V) × D= 181.82 × (ΔA + 0.0165) ÷ Cpr × D

3.Calculation based on liquid volume:

Peroxide value (μg/mL) = [(ΔA + 0.0165) ÷ 0.0055] × D = 181.82 × (ΔA + 0.0165) × D

4.Calculation based on bacterial/cell density:

Peroxide value (μg/10⁴ cells) = [(ΔA + 0.0165) ÷ 0.0055 × V₁] ÷ (V₁ ÷ V × 500) × D= 181.82 × (ΔA + 0.0165) ÷ 500 × D

W: sample mass, g;

V: extraction solution volume, 1 mL;

V₁: sample volume added, 0.05 mL;

500: total number of bacteria or cells, in units of 10⁴;

D: dilution factor (1 if undiluted);

Cpr: protein concentration of the supernatant, mg/mL.

Appendix: Standard Curve Preparation Procedure:

1.The standard curve is optional. Users may prepare a standard curve according to experimental needs, or directly use the calculation formula in the instructions for result calculation.

2.The standard stock solution concentration is 1000 μg/mL. Dilute the stock solution with pure methanol to prepare six concentration gradients of standards, for example: 0, 20, 40, 60, 80, 100 μg/mL. The standard concentrations may also be adjusted according to actual samples.

3.Refer to the following table for standard dilution:

Pipette 100 μL of the standard stock solution, add 900 μL of pure methanol, and mix well to obtain a 100 μg/mL standard diluent for later use.
Standard concentration (μg/mL)020406080100
Standard diluent (μL)04080120160200
Pure methanol (μL)20016012080400
Mix each standard tube well and set aside for use.

4.Operate according to the assay tube loading table. Based on the results, subtract the absorbance at 0 concentration from the absorbance at each concentration, and construct the standard curve through the zero point.

Reagent (μL)Standard Tube (A)Zero Concentration Tube A0 (once only)
Standard50—
Pure methanol910960
Reagent II1010
Mix well and incubate at room temperature for 5 min. Transfer 200 μL to a 96-well plate and measure the absorbance (A) at 500 nm. ΔA = Astandard tube − A0 concentration tube.

Spécifications

Spécifications et pureté
BioReagent
Grade
BioReagent
Application
Cell Metabolism
Type d'échantillon
Animal and Plant tissues, Bacteria, Cell
Méthode de détection
Colorimetric Method
Quantitatif
Quantitative
Detection instrument
Microplate reader
Detection wavelength
500nm
Sensibilité
Light-sensitive
Stockage et expédition
Conditions de stockage de stockage
Store at 2-8°C,Protected from light
Expédié en
Wet ice
Stabilité et stockage
Store at 2-8℃ long term (12 months). Store in the dark.
Contents & Storage
Component No.Component NameAppearance96TStorage
P1522268AReagent ILiquid1EA2-8℃. Store in the dark
P1522268BReagent IIPowder1EA2-8℃. Store in the dark
P1522268CStandardLiquid2mL2-8℃. Store in the dark

Documentation

📋 Fiche de données de sécurité (FDS)

Document complet couvrant les dangers, la manipulation, le stockage et la conformité réglementaire.

<<<<<<< HEAD Télécharger la SDS → ======= Télécharger la SDS → >>>>>>> release248-p3

✅ Certificat d'analyse (COA)

Données qualité spécifiques au lot. Saisissez votre numéro de lot pour récupérer le COA exact.

Rechercher le COA →

📊 Fiche technique

Résumé de référence rapide des spécifications et applications du produit.

Voir la fiche technique →

🔬 Fiche de spécifications

Attributs de qualité complets et critères d'acceptation pour cette qualité.

Voir la fiche de spécifications →

Données avancées

Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculateurs de solution
Avis

Avis des clients

Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?

Me rappeler plus tard

Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.

Oups ! Les notifications sont désactivées.