Soil Total Phosphate Assay Kit (MB, Micro Method)

Cat. No.: S1522127
DISPONIBLE À COMMANDE
QUALITÉ & PURETÉ BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Taille
USA
Allemagne (EU)*
Prix
Qté
48T
S1522127-48T
Fabrication sur commande aux États-Unis · 2–4 semaines ·
—
179,90$US
96T
S1522127-96T
Sur commande · 8–12 semaines
299,90$US
Enter a quantity for the sizes you want to add.
🧪
Pourquoi cette qualité

BioReagent BioReagent pour les flux de travail chromatographiques et analytiques sensibles nécessitant une interférence de ligne de base minimale.

🌡

Stockage & expédition

Store at 2-8°C,Protected from light Expédition Wet ice. Consultez le COA spécifique au lot pour les spécifications exactes.

📋

Documents qualité

SDS, COA, fiche technique et fiche de spécifications disponibles au téléchargement. COA spécifique au lot accessible via la recherche par numéro de lot.

📚

Preuve documentaire

Cité dans 0 publications à comité de lecture couvrant la chromatographie, la synthèse organique et les réactions de couplage croisé.

Vue d’ensemble

In acidic solution, under the action of decomposing agent and high temperature, inorganic phosphate and organic phosphate are hydrolyzed into orthophosphate. Orthophosphate reacts with ammonium molybdate to form phosphomolybdic acid, which is then reduced to phosphomolybdenum blue in the presence of a reducing agent, with a characteristic absorbance peak at 710 nm.

Item No.AppearanceComponents48T96TStorage
S1522127ALiquidReagent Ⅰ10 mL20 mL2-8 ℃
S1522127BLiquidReagent Ⅱ15 mL30 mL2-8 ℃
S1522127CLiquidReagent Ⅲ 2.8 mL5.6 mL2-8 ℃. Store in the dark.
S1522127DPowderReagent Ⅳ1 vial1 vial2-8 ℃
S1522127ELiquidReagent V44.8 µL44.8 µL2-8 ℃
S1522127FLiquidStandard1 mL1 mL2-8 ℃

Notes: Before formal detection, it is recommended to conduct preliminary trials with 2–3 samples with expected large differences in phosphate content.

Self-Prepared Consumables and Instruments

1.Microplate reader or visible spectrophotometer (capable of absorbance detection at 710 nm)

2.96-well microplate or micro glass cuvettes, adjustable pipettes and pipette tips

3.Tabletop centrifuge, 30–50 mesh sieve, thermostatted water bath

4.Deionized water

Reagent Preparation

Reagent I: Ready-to-use; equilibrate to room temperature before use; store at  2-8 °C.

Reagent II: Ready-to-use; equilibrate to room temperature before use; store at 2-8 °C.

Reagent III: Ready-to-use; equilibrate to room temperature before use; store at 2-8 °C protected from light.

Working Reagent IV: Prepare immediately before use. Add 5.6 mL deionized water and dissolve completely, then add Reagent V and mix thoroughly. Working Reagent IV contains a small amount of insoluble precipitate; shake well before use. Stable for 1 week when stored at  2-8 °C.

Reagent V: Ready-to-use; equilibrate to room temperature before use; store at 2-8 °C.

Notes: Reagent I, Reagent II, Reagent III and Reagent V are irritant. Adequate personal protective equipment must be worn during all operations.

Standard Solution: Ready-to-use; equilibrate to room temperature before use; store at  2-8 °C.

Standard Solution Preparation: Dilute the 1 μmol/mL standard stock solution stepwise as shown in the table below.

No.Standard VolumeDeionized Water Volume (μL)Concentration (μmol/mL)
Std.150 μL of 100 μL 1 μmol/mL stock1500.25
Std.2100 μL of Std.1 (0.25 μmol/mL)1000.125
Std.3100 μL of Std.2 (0.125 μmol/mL)1000.063
Std.4100 μL of Std.3 (0.063 μmol/mL)1000.031
Std.5100 μL of Std.4 (0.031 μmol/mL)1000.016
Std.6100 μL of Std.5 (0.016 μmol/mL)1000.008
Blank01000

Notes: A standard curve must be generated alongside each independent experiment. Diluted standard solutions are unstable and must be used within 4 hours of preparation.

Sample Preparation

Fresh samples are recommended for immediate detection. If testing cannot be performed promptly, samples can be stored at −80 °C for several weeks. Control thawing temperature and duration strictly; complete thawing within 4 hours at room temperature.

1.Air-dry fresh soil samples and sieve through a 30–50 mesh screen.

Mix soil mass (g) : deionized water volume (mL) : Reagent I volume (mL) : Reagent II volume (mL) = 1:10:1:2.

Practical operation: Weigh approximately 0.1 g soil sample, add 1 mL deionized water, followed by 100 μL Reagent I and 200 μL Reagent II. Shake in a 95 °C boiling water bath for 30 min, centrifuge at 10,000 g, 25 °C for 10 min, collect supernatant for subsequent detection.

Assay Procedure

1.Preheat the microplate reader or visible spectrophotometer for ≥30 min, set detection wavelength to 710 nm. Zero the spectrophotometer with deionized water if applicable.

2.Assay layout (operations performed in 96-well microplate or micro glass cuvettes):

 

ReagentBlank Well (μL)Standard Well (μL)Test Well (μL)
Sample0040
Standard Solution0400
Reagent Ⅲ404040
Working Reagent Ⅳ404040
Deionized Water1208080

3. Mix thoroughly and incubate at 25 °C for 10 min. Measure absorbance at 710 nm and record the absorbance values as Ablank, Astandard and Asample respectively.

Calculation formulas: ΔAsample = Asample − Ablank ΔAstandard = Astandard − Ablank
Notes: Blank wells and standard curve only need to be tested once per experiment. It is recommended to conduct preliminary experiments with 2–3 samples with obvious expected differences before formal detection. 
If ΔAsample is less than 0.01, appropriately increase the sample dosage. 
If ΔAsample exceeds the ΔAstandard value corresponding to 0.25 μmol/mL, further dilute the sample with deionized water (multiply the final calculation result by the dilution factor), or reduce the amount of soil sample used for extraction.

Result Calculation

Notes: Two equivalent formulas are provided, namely the full derivation formula and the simplified formula.

1. Standard Curve Construction: Plot the standard curve with standard solution concentration as the x-axis and ΔAstandard as the y-axis to obtain the standard equation. Substitute ΔAsample into the equation to get x (μmol/mL).2. Calculation of Total Phosphate Content: Total phosphate content (μmol/g) = x × Vsample ÷ (W × Vsample ÷ Vtotal-extraction) = 1.3 × x ÷ W 
Vsample: Volume of sample added, 0.04 mL 
Vtotal-extraction: Total extraction volume of sample, 1.3 mL 
W: Mass of soil sample, g
Results Presentation

Figure 1. Total phosphate content in soil detected by this kit

Disclaimer

This product is for research purposes only and is not suitable for clinical diagnosis. Please wear a lab coat and disposable gloves during operation to ensure your safety and health.

Spécifications

Synonymes
Soil Total Phosphorus Assay Kit (Micro Method)
Spécifications et pureté
BioReagent
Grade
BioReagent
Application
Cell Metabolism
Type d'échantillon
Soil
Méthode de détection
MB, Spectrophotometry
Quantitatif
Quantitative
Detection instrument
Microplate reader,Visible Spectrophotometer
Detection wavelength
710nm
Sensibilité
Light-sensitive
Stockage et expédition
Conditions de stockage de stockage
Store at 2-8°C,Protected from light
Expédié en
Wet ice
Stabilité et stockage
Store at 2-8 ℃ long term (12 months). Store in the dark.
Contents & Storage
Item No.AppearanceComponents48T96TStorage
S1522127ALiquidReagent Ⅰ10 mL20 mL2-8 ℃
S1522127BLiquidReagent Ⅱ15 mL30 mL2-8 ℃
S1522127CLiquidReagent Ⅲ 2.8 mL5.6 mL2-8 ℃. Store in the dark.
S1522127DPowderReagent Ⅳ1 vial1 vial2-8 ℃
S1522127ELiquidReagent V44.8 µL44.8 µL2-8 ℃
S1522127FLiquidStandard1 mL1 mL2-8 ℃

Documentation

📋 Fiche de données de sécurité (FDS)

Document complet couvrant les dangers, la manipulation, le stockage et la conformité réglementaire.

<<<<<<< HEAD Télécharger la SDS → ======= Télécharger la SDS → >>>>>>> release248-p3

✅ Certificat d'analyse (COA)

Données qualité spécifiques au lot. Saisissez votre numéro de lot pour récupérer le COA exact.

Rechercher le COA →

📊 Fiche technique

Résumé de référence rapide des spécifications et applications du produit.

Voir la fiche technique →

🔬 Fiche de spécifications

Attributs de qualité complets et critères d'acceptation pour cette qualité.

Voir la fiche de spécifications →

Données avancées

Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
FAQ et articles
Calculateurs de solution
Avis

Avis des clients

Besoin d'aide pour choisir la qualité ?

Notre guide de sélection des qualités couvre la pureté, le statut du stabilisant et l'adéquation à l'application pour toutes les variantes de notre catalogue.

Voir le guide des qualités BioReagent →

Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?

Me rappeler plus tard

Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.

Oups ! Les notifications sont désactivées.