QUALITÉ & PURETÉBioReagent?BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
This kit employs the competitive enzyme-linked immunosorbent assay (ELISA) principle. Microplate wells are pre-coated with TXA2 antigen. The sample, standards, a biotin-labeled antibody, and an HRP enzyme conjugate are then added sequentially to the wells. The procedure includes incubation and wash steps between each addition. TMB substrate is used for color development. In the presence of the peroxidase (HRP) enzyme, TMB is catalyzed to produce a blue color, which is then converted into a final stable yellow color upon the addition of an acid stop solution. The intensity of the resulting yellow color is inversely proportional to the concentration of TXA2 in the sample. The optical density (OD) is measured at a wavelength of 450 nm using a microplate reader, and the concentration of the target analyte in the sample is calculated based on the standard curve.
Spécifications
Spécifications et pureté
BioReagent
Grade
BioReagent
Application
ELISA
Type d'échantillon
Plasma, Serum
Plage de détection
15.6pg/mL~1000pg/mL
Spécificité
Detecting TXA2 in samples, with no significant cross-reactivity to other homologs.
Detection instrument
Microplate reader
Detection wavelength
450nm
Repeatability
The intra- and inter-assay coefficients of variation (CV) are both <10%.
Detection duration
3.5 hours, not including equilibration and sample preparation time.
Stockage et expédition
Conditions de stockage de stockage
Store at 2-8°C
Expédié en
Wet ice
Stabilité et stockage
Store at 2-8℃ for 6 months.
Données avancées
Certificats (CoA, COO, BSE/TSE et tableau d'analyse)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculateurs de solution
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Avis
Avis des clients
Application Protocols
Item-specific details (required volumes, incubation times, standard concentrations, validated matrices): Not specified for this item; consult the kit insert.
General protocol outline (competitive ELISA; literature)
Preparation: Bring all reagents to room temperature. Prepare standards by serial dilution in the provided diluent. Determine appropriate sample dilutions to fall within the standard curve.
Plate loading: Add standards, controls, and samples to wells, followed by enzyme conjugate and antibody as per kit design (order may vary). Avoid bubbles; record plate map.
Incubation: 1–2 h at room temperature or as directed. Protect from light if HRP/TMB is used.
Washing: Perform 3–5 washes with the supplied wash buffer, ensuring complete removal of liquid between cycles.
Detection: Add substrate, incubate to develop color, then add stop solution. Read at 450 nm (with 620–650 nm reference if available).
Calculations: Fit a 4PL/5PL logistic model to standards; interpolate sample concentrations and apply dilution factors.
Sample handling notes (literature)
For eicosanoids, process samples rapidly on ice; consider acidification and/or antioxidants as compatible with the kit to limit ex vivo conversion. Matrix compatibility and recovery must be verified experimentally.
Biological Roles
General/literature context (about TXA2)
Thromboxane A2 is an eicosanoid produced from arachidonic acid via COX-1/COX-2 followed by thromboxane synthase. It is a short‑lived autacoid acting through TP receptors.
Key roles: Promotes platelet activation and aggregation, supports vasoconstrictive tone, and modulates smooth muscle responses (literature). It functions in concert with prostacyclin (PGI2) and other prostanoids in hemostatic balance.
Stability: TXA2 is chemically unstable and rapidly hydrolyzes non‑enzymatically to TXB2; biological measurements frequently quantify TXB2 as a surrogate for TXA2 biosynthesis (literature note).
Sample matrices (literature): Serum, plasma, urine, cell culture supernatants, and tissue extracts are commonly analyzed for thromboxane pathway activity using immunoassays.
Item-specific applicability
This kit is designated as a Thromboxane A2 (TXA2) ELISA Kit for research use. Exact target form (TXA2 vs TXB2), cross-reactivity profile, and validated matrices are not specified for this item; consult the kit insert/CoA for definitive details.
Buffer Applications
Not a buffering reagent. However, ELISA performance depends critically on buffers (general guidance):
Coating and blocking buffers: Carbonate-bicarbonate or PBS-based systems with protein blockers reduce nonspecific binding. Composition for this item is not specified.
Wash buffer: Typically PBS or TBS with 0.05–0.1% Tween-20 to lower background (literature). Exact formulation for this kit is not provided.
Sample/standard diluent: Often protein-containing buffers with defined ionic strength and pH to preserve analyte stability. For eicosanoid measurements, some protocols recommend acidification or stabilizers; follow the kit insert. Not specified for this item.
Green Alternatives
This section is not directly applicable to an ELISA kit. Sustainability considerations for ELISA workflows (general/literature):
Waste minimization: Use multi-channel pipetting and plan plate layouts to reduce repeats; consolidate washes to minimize buffer consumption when permissible.
Reagent substitution: Where compatible, use aqueous, non-azide preservatives to reduce hazardous waste. The preservative system in this item is not specified.
Plastics: Employ recyclable tip boxes and plate seals when possible; segregate uncontaminated packaging for recycling.
Energy: Store at 2–8°C as required; avoid unnecessary freezer storage if not specified.
Pharmaceutical Uses
Not applicable as a therapeutic or excipient. This ELISA kit is for research use only and is not approved for diagnostic, clinical, or manufacturing release testing. In pharmaceutical R&D settings, such kits may be used for exploratory biomarker quantification, assay development, or process research (general). Item-specific regulatory status and pharmacopeial references: Not specified for this item.
Physical Properties
Item-specific facts
Physical constants (BP/MP/density/refractive index/logP/pKa/UV cutoff): Not specified for this item; refer to CoA/Spec Sheet.
Kit format: Typical ELISA components (coated plate, standards, detection reagent, buffers, stop solution) are expected in principle; the exact contents are not specified for this item.
General/literature values (for the analyte)
TXA2 is chemically labile in aqueous solution (half-life seconds to minutes at physiological pH), spontaneously forming TXB2 (literature). Quantitative numerical constants are seldom specified due to rapid decomposition and are matrix- and pH‑dependent.
Practical implications
Because the kit targets TXA2 biology, samples are commonly handled cold with rapid processing and, when appropriate, stabilizers/acidification to minimize ex vivo conversion (literature guidance). Follow the kit insert for definitive instructions (not specified for this item).
Quality and Grades
Item-specific facts
Grade: BioReagent (from Product Data). This denotes suitability for laboratory research workflows; not intended for diagnostic or therapeutic use.
What BioReagent grade typically implies (general)
Reagents and antibodies calibrated for reproducible analytical performance in research ELISAs, with lot-to-lot QC against internal acceptance ranges (e.g., standard curve fit, background, and accuracy). Specific QC criteria for this item are not provided.
Low cross-contamination manufacturing and validated storage/shipping conditions to maintain activity of immobilized ligands and enzyme conjugates.
Interpretation for end users
Use the kit strictly for research applications (Research Use Only). Not validated for clinical decision-making.
For method validation, verify linearity, spike/recovery, and precision within your matrices. Actual performance specifications (e.g., LOD/LOQ, dynamic range, cross-reactivity) are not specified for this item; consult the kit insert/CoA.
Stabilizers/preservatives: Not specified for this item; refer to the Spec Sheet. Presence/absence can influence background and compatibility with sample additives.
Reaction and Applications
Not applicable in the synthetic chemistry sense. This product is an immunoassay kit used to quantify an analyte in biological or research samples. For practical use, focus on Application Protocols and Biological Roles sections below. If chemical derivatization or extraction is needed during sample prep (e.g., for eicosanoids, literature), defer to the kit insert; details are not specified for this item.
Reaction Conditions
Not applicable to chemical synthesis. For ELISA assay conditions (general/literature):
Incubations: Commonly 1–2 h at room temperature or overnight at 2–8°C depending on sensitivity requirements and kit design.
Detection: Enzyme-linked detection (e.g., HRP/TMB) with absorbance read at 450 nm (reference 620–650 nm) is typical; the exact enzyme/substrate for this item is not specified.
Standard curve: Typically 7–8 points, serially diluted. Dynamic range, LOD/LOQ, and curve fit model are not specified for this item and must be obtained from the insert.
Safety and Handling
Item-specific facts
GHS classification, signal word, H-statements, pictograms: Not specified for this item; consult the SDS for authoritative hazard information.
Storage: 2–8°C (as supplied). Shipments on wet ice.
General guidance for ELISA kits (literature/practice)
Components may include preservatives (e.g., ProClin, Kathon, thimerosal) and acidic or basic stop solutions (e.g., 1–2 N H2SO4) in some kits. Treat all liquids as potentially irritating or sensitizing. The exact preservatives/acid are not specified for this item.
PPE: Lab coat, safety glasses, and appropriate chemical-resistant gloves. Avoid inhalation/ingestion and contact with skin/eyes.
Handling: Bring components to room temperature before use only as instructed; keep standards and conjugates protected from light if dye/HRP conjugates are present. Avoid microbial contamination of reagents.
Incompatibilities: Do not mix components from different lot numbers or vendors. Do not freeze components unless explicitly permitted by the insert.
First aid (overview): In case of skin/eye contact, rinse with water for several minutes; if inhaled, move to fresh air; if ingested, rinse mouth. Seek medical advice per SDS.
Waste: Dispose of used microplates, tips, and biological liquids as chemical/biological laboratory waste per institutional policy.
Biosafety: Treat all biological samples as potentially infectious and handle under BSL-2 good practices as applicable.
Solvent Selection
Not typically applicable. This is an ELISA kit, not a small‑molecule reagent or solvent. For sample preparation, follow the kit’s instructions for recommended sample diluents and wash buffers. If organic solvents are required for lipid extraction of eicosanoids (literature), ensure compatibility with the kit’s assay buffer and plate; specifics are not provided for this item.
Storage and Reconstitution
Item-specific facts
Storage: Store the kit at 2–8°C (as provided).
Shipping: Shipped on wet ice.
Reconstitution details for individual components (e.g., lyophilized standards, conjugates): Not specified for this item; refer to the kit insert/Spec Sheet.
General guidance (ELISA kits; literature/practice)
Upon receipt: Inventory all components and note expiration. Do not freeze components unless expressly allowed by the insert.
Stability: Keep standards and enzyme conjugates tightly capped and protected from light. Minimize repeated warming/cooling; aliquot reconstituted standards if permitted by instructions.
Reconstitution: Use the specified diluents and volumes; mix gently to avoid foaming. Allow lyophilized materials to fully dissolve before use.
Working solutions: Prepare wash buffers and substrate immediately before use when possible. Discard leftover working solutions to prevent contamination.
Plate storage: If partial plates are used, store unused strips in the sealed foil pouch with desiccant at 2–8°C.
Freeze–thaw: Avoid repeated freeze–thaw of standards or controls; follow insert for permissible cycles (not specified for this item).
Structure and Identity
Item-specific facts (from Product Data)
Product type: ELISA kit for detection/quantification of Thromboxane A2 (TXA2)
SKU: EJ1515329
Grade: BioReagent
Storage: 2–8°C; shipped on wet ice
CAS, SMILES, InChIKey, molecular formula, molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
General/literature context (about the analyte TXA2)
TXA2 is an eicosanoid derived from arachidonic acid via cyclooxygenase and thromboxane synthase pathways.
Structural features (literature): A C20 lipid with a bicyclic oxane-like ring system containing an endoperoxide-derived framework and multiple unsaturations; chemically unstable, rapidly hydrolyzes non‑enzymatically to thromboxane B2 (TXB2).
Assay design note (literature): Many TXA2 immunoassays quantify TXB2 as a stable proxy for TXA2. The exact antigen/analyte recognized (TXA2 vs TXB2 or related derivatives) must be verified in the kit’s instructions; not specified for this item.
Synthetic Utility
Not applicable. This product is not a synthetic building block or reagent. For workflows related to eicosanoids, synthetic utility would pertain to standards (TXB2, deuterated analogs) used as calibrators in analytical chemistry; such standards are not part of the current item as specified. Refer to analytical standards catalogs for synthetic reagents.
Target Specificity
Item-specific facts
Intended analyte: Thromboxane A2 (TXA2) per product name.
Clone, isotype, antigen epitope, species cross-reactivity, and cross-reactants: Not specified for this item; refer to the kit insert/CoA for definitive details.
General/literature context
Many TXA2 immunoassays are competitive ELISAs that may employ antibodies raised against TXA2 derivatives (e.g., TXB2 conjugates) due to TXA2 instability. Cross-reactivity with related eicosanoids (PGs, HETEs) is a key performance attribute and should be reviewed in the manufacturer’s documentation. None of these details are specified for this item.
Besoin d'aide pour choisir la qualité ?
Notre guide de sélection des qualités couvre la pureté, le statut du stabilisant et l'adéquation à l'application pour toutes les variantes de notre catalogue.
Nous utilisons des cookies pour garantir le bon fonctionnement du site et, lorsque cela est autorisé, pour améliorer votre expérience. Vous pouvez gérer vos préférences à tout moment dans les Paramètres. Pour en savoir plus, consultez notre Politique relative aux cookies.
Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?
Me rappeler plus tard
Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.