Determine the necessary mass, volume, or concentration for preparing a solution.
ベースライン干渉を最小限に抑える必要がある、感度の高いクロマトグラフィーおよび分析ワークフロー向け。
Store at -20°C,Avoid repeated freezing and thawing Ice chest + Ice pads に出荷。正確な仕様については、ロット固有の COA をご確認ください。
SDS、COA、データシート、仕様書をダウンロードできます。ロット固有の COA はロット番号検索で入手可能です。
クロマトグラフィー、有機合成、クロスカップリング反応に関する 0 件の査読済み論文で引用されています。
This product is a premixed system composed of Es Taq DNA Polymerase, Mg2+, dNTPs, PCR stabilizers and enhancers, with a concentration of 2 ×. Es Taq DNA Polymerase has excellent performance of high amplification efficiency and low mismatch rate. The unique MasterMix formula makes the entire reaction system very stable, with over 98% of PCR amplification successful at once. At the same time, complex templates can also be effectively amplified, and human error and contamination can be minimized to the greatest extent. This product does not contain dyes. After the PCR program is completed, an appropriate amount of sample buffer can be added as needed for electrophoresis operation. Most PCR products obtained from amplification have an "A" base attached to the 3 'end, making them suitable for direct use in T/A cloning. Mainly suitable for routine PCR reactions and gene cloning experiments that require high fidelity.
Notes: 2×Es Taq MasterMix contains Es Taq DNA Polymerase, 3mM MgCl2 and 400µM each dNTP. |
Quality control:
After testing, there was no exogenous nuclease activity; PCR method for detecting residual DNA without host; Can effectively amplify single copy genes from multiple genomes.
Usage:
The following is an example of a PCR reaction system and reaction conditions for amplifying a 1 kb fragment using human genomic DNA as a template. In practical operation, corresponding improvements and optimizations should be made based on the template, primer structure, and target fragment size.
1. PCR reaction system
|
Attention: The primer concentration should be between 0.1 and 1.0 as the final concentration μ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system.
2. PCR reaction conditions
|
Attention:
1) In general experiments, if the annealing temperature is 5 ℃ lower than the melting temperature Tm of the amplification primer, and the ideal amplification efficiency cannot be achieved, the annealing temperature should be appropriately reduced; When non-specific reactions occur, increase the annealing temperature to optimize the reaction conditions.
2) The extension time should be set according to the size of the amplified fragment, and the amplification efficiency of Es Taq DNA Polymerase is 2 kb/min.
3) The number of cycles can be set based on the downstream application of the amplification product. If the number of cycles is too small, the amplification amount is insufficient; If there are too many cycles, the probability of mismatches will increase, and non-specific backgrounds will be severe. So, while ensuring product yield, the number of cycles should be minimized as much as possible.
危険性、取扱い、保管、および規制遵守を網羅した包括的な文書。
<<<<<<< HEAD SDS をダウンロード → ======= SDS をダウンロード → >>>>>>> release248-p3