eECL Western Blot Kit

Cat. No.: E665966
注文可能
★
サイズ
USA
ドイツ (EU)*
価格
個数
250ml
E665966-250ml
US製・受注生産 · 2~4週間 ·
—

$427.90

$499.90
保存 $72.00 (14.40%)
50ml
E665966-50ml
US製・受注生産 · 2~4週間 ·
—

$110.90

$129.90
保存 $19.00 (14.63%)
Enter a quantity for the sizes you want to add.
🧪
このグレードを選ぶ理由

ベースライン干渉を最小限に抑える必要がある、感度の高いクロマトグラフィーおよび分析ワークフロー向け。

🌡

保管・配送

Store at 2-8°C,Protected from light Wet ice に出荷。正確な仕様については、ロット固有の COA をご確認ください。

📋

品質書類

SDS、COA、データシート、仕様書をダウンロードできます。ロット固有の COA はロット番号検索で入手可能です。

📚

文献的裏付け

クロマトグラフィー、有機合成、クロスカップリング反応に関する 0 件の査読済み論文で引用されています。

概要

Product content

E665966Component50 mL250 mLStorage
E665966AeECL-A (Luminol Enhancer)
25 mL 125 mL2-8℃.Protect from light.
E665966BeECL-B (Peroxide) 25 mL 125 mL2-8℃.Protect from light.

Products

The High Sensitivity Chemiluminescent Assay is a highly sensitive and enhanced assay for use with horseradish peroxidase (HRP) in immunoblotting experiments. It is based on a new generation of enhanced chemiluminescent substrate, which is catalyzed by HRP to emit light, and can be used to detect biological macromolecules such as proteins immobilized on membranes. The high sensitivity enables the detection of pg-level antigens with a strong and long-lasting luminescence signal, which can be detected by X-ray film exposure or chemiluminescence imaging.

Caveat

1. Please wear gloves and use clean equipment such as tweezers during the contact with the membrane to avoid protein contamination and high background.

2. Under the condition of avoiding light, the prepared working solution of chemiluminescence detection substrate can be stored stably at room temperature for 8 hours. Sunlight or other strong light may affect the working solution, so avoid prolonged exposure to strong light. Normal laboratory lighting for a short period of time does not affect the use of the working solution.

3. Aladdin Reagent offers a wide range of membranes for protein transfer, containment solutions, primary antibodies, enzyme-labeled secondary antibodies, buffers, etc. For details, please check the company's website.

Procedure

1. After incubation of the secondary antibody, the blotting membrane is washed thoroughly.

2. According to the required amount, eECL-A and eECL-B are mixed in equal volumes at a ratio of 1:1, and prepared as a chemiluminescence detection substrate working solution (about 1m working solution is used for an 8cm×6cm membrane).

3. Discard the washing buffer, add the luminescent substrate working solution dropwise onto the blotting membrane, make sure the working solution covers the whole membrane, and incubate for 3-5 minutes at room temperature.

4. Pipette off excess luminescent substrate working solution and place the blotting membrane between two layers of clean plastic film, this process should be completed carefully to avoid air bubbles between the membrane and the membrane.

5. X-ray film exposure is performed in a dark room, or the membrane is placed inside a chemiluminescence imager and tested according to the instrument instructions.

Schedules

concern

Possible causes

cure

Film reversal (white stripes, black background)

)

 

Excess HRP in the system

 

 

Dilute the HRP marker at least 10-fold.

Brown or yellow bands appear on the membrane

 

 

Strong glow seen in dark room

 

 

Short duration of light signal

 

 

 

 

Weak or no signal

Excessive HRP in the luminescent reaction system, eliminating Excessive substrate depletion, causing rapid signal reduction

 

Dilute the HRP marker at least 10-fold.

 

Insufficient amount of antigen/antibody

Increased antigen/antibody usage

 

Low protein transfer rate

Optimization of the transfer system

 

 

 

high context

Excess HRP in the system

Dilute the HRP marker at least 10-fold.

 

insufficiently closed

Optimization of closure procedures

 

Poor choice of containment reagents

Select another containment reagent

 

Inadequate rinsing

Increase rinsing time, frequency

 

overexposure

Reduced exposure time

 

High antigen/antibody concentration

Reduce the concentration of antigen/antibody used

 

Protein bands are punctate

Protein transfer failure

Optimizing the transfer process

 

Membrane not in equilibrium

Handle the membrane according to the instructions

 

Air bubbles between film and membrane

Remove all air bubbles before exposure

Presence of non-specific bands

(high background, short signal duration)

 

Too much HRP in the system

 

Dilution of HRP markers

Presence of non-specific bands

(background clean signal maintenance time normal)

Excessive use of monoclonal antibody

Further dilution of primary antibody

 

SDS leads to non-specific binding

Avoid using SDS during experiments

保管と配送
保管条件
Store at 2-8°C,Protected from light
入荷
Wet ice

ドキュメント

📋 安全データシート(SDS)

危険性、取扱い、保管、および規制遵守を網羅した包括的な文書。

<<<<<<< HEAD SDS をダウンロード → ======= SDS をダウンロード → >>>>>>> release248-p3

✅ 分析証明書(COA)

ロット固有の品質データ。ロット番号を入力して、正確な COA を取得してください。

COA を検索 →

📊 データシート

製品仕様と用途のクイックリファレンス概要。

データシートを見る →

🔬 仕様書

このグレードの完全な品質特性と合格基準。

仕様書を見る →

詳細データ

証明書(CoA、COO、BSE/TSEと分析図)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate Type日付商品
ZJ25F0521893ZJ25F0521893Certificate of AnalysisMar 15, 2026 E665966
ZJ25F0420894ZJ25F0420894Certificate of AnalysisFeb 10, 2026 E665966
よくある質問と記事
ソリューション計算機
レビュー

顧客レビュー

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.