グレード&純度BioReagent?BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.Suitable for Analysis?Suitable-for-analysis grade — purity adequate for general analytical procedures. Use as a dependable analytical reagent across routine methods.Colorimetry?Colorimetry grade — purity suited to color-development quantitative assays. Use where reagent purity affects color intensity and accuracy.Standard Curve Method?
BioReagent, Colorimetry, Suitable for Analysis, Standard Curve Method
等級
BioReagent, Colorimetry, Standard Curve Method, Suitable for Analysis
アプリケーション
Cell Metabolism
検出範囲
0.625-40 μg/mL
検出方法
Fluorometric Method; Micro-method
定量的
Quantitative
Detection instrument
Microplate reader
Detection wavelength
激发光波长535 nm,发射光波长587 nm
感度
Light-sensitive
Detection duration
60 min
Sample volume
50 μL
保管と配送
保管条件
Store at -20°C
入荷
Ice chest + Ice pads
安定性と保管
Each component has a shelf life of 1 year under corresponding storage conditions.
Contents & Storage
G1373331
Component Name
Appearance
100 T
Storage
Quantity Per Test
G1373331A
Assay Buffer
Liquid
20 mL
-20°C.
As needed
G1373331B
Amyloglucosidase
Liquid
200 μL
-20°C. Store in the dark
2 μL
G1373331C
Glucose Oxidase
Liquid
200 μL
-20°C. Store in the dark
2 μL
G1373331D
Horseradish Peroxidase
Liquid
200 μL
-20°C. Store in the dark
2 μL
G1373331E
Amplex Red
Liquid
200 μL
-20°C. Store in the dark
2 μL
G1373331F
Glycogen Standard (2 mg/mL)
Liquid
600 μL
-20°C. Store in the dark
6 μL
画像
Glycogen Assay Kit (Fluorometric Method) (G1373331) - Standard curve assay
Glycogen is converted to glucose by amyloglucosidase, and the glucose is then oxidized by glucose oxidase to generate hydrogen peroxide. In the presence of horseradish peroxidase, Amplex Red reacts with hydrogen peroxide to produce the strongly red‑fluorescent compound resorufin. The fluorescence intensity of resorufin is directly proportional to the glycogen content in the sample, and the glycogen concentration can be calculated from the fluorescence intensity of resorufin. This kit can detect glycogen concentrations as low as 0.625 μg/mL in samples, and exhibits a good linear relationship within the range of 0.625 - 40 μg/mL.
詳細データ
証明書(CoA、COO、BSE/TSEと分析図)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Find and download the COA for your product by matching the lot number on the packaging.
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
レビュー
顧客レビュー
Application Protocols
The following workflow is general, literature-based guidance for fluorometric glycogen assays and is not an item-specific protocol. Always follow the kit insert for definitive instructions.
General microplate workflow:
Prepare standards: serially dilute glycogen or glucose standard in assay buffer to cover the expected sample range.
Prepare samples: homogenize/lyse, clarify, and optionally deproteinize; split into “+hydrolysis” and “–hydrolysis” aliquots.
Hydrolysis: add glycogen-hydrolyzing enzyme to “+hydrolysis” wells; incubate at 37°C to convert glycogen to glucose.
Detection: add fluorometric detection mix to all wells; protect from light and incubate until signal develops.
Readout: measure fluorescence at the probe-appropriate Ex/Em. Subtract background (–hydrolysis) from “+hydrolysis” values.
Quantification: fit a standard curve and interpolate sample concentrations; correct for dilution factors and normalize to protein or tissue mass if desired.
Tips for reproducibility:
Use matched timing across wells; employ multichannel pipettes or automation.
Equilibrate reagents to working temperature; keep enzymes/probes on ice until use.
Include internal QC samples across plates to monitor run-to-run consistency.
Specific reagent volumes, concentrations, and incubation times for this item are Not specified; refer to the product manual/CoA.
Biological Roles
Glycogen is the principal storage polysaccharide in animals and many microorganisms, serving as a readily mobilizable glucose reserve (general/literature context).
Structure and localization:
Composed of α(1→4)-linked D-glucose with α(1→6) branches approximately every 8–12 residues, forming granules associated with proteins such as glycogenin (primer protein) and enzymes of metabolism.
Predominantly stored in liver and skeletal muscle in mammals; also present in brain, heart, and certain immune cells; in microbes, contributes to carbon/energy storage.
Metabolic roles:
Glycogenesis: UDP-glucose is polymerized by glycogen synthase and branching enzyme; regulated by insulin and nutrient status.
Glycogenolysis: Glycogen phosphorylase and debranching enzyme liberate glucose-1-phosphate and glucose; regulated by glucagon/epinephrine and cellular energy charge.
Cross-talk with glycolysis, gluconeogenesis, and the pentose phosphate pathway; influences redox balance via NADPH production when glucose is routed through PPP.
Research implications:
Quantifying glycogen informs on metabolic state, training adaptation in muscle models, circadian metabolism, and microbial carbon storage dynamics.
Distinguishing free glucose from glycogen-derived glucose is essential; “minus-hydrolysis” controls quantify baseline glucose.
This section provides general biochemical context. It does not imply any clinical or diagnostic use of the product.
Buffer Applications
This product is an assay kit rather than a buffering agent. It does not define a specific buffer system for general lab use.
General guidance (literature):
Assay buffers in glycogen kits are typically mildly buffered aqueous solutions optimized for enzyme activity and probe stability (pH often near neutral). Exact composition/pH for this item is Not specified; refer to the kit insert.
For sample extraction, commonly used buffers include phosphate-buffered saline or HEPES-based solutions with protease inhibitors, provided they do not interfere with the assay enzymes or fluorescence.
Deproteinization steps (e.g., ultrafiltration or mild acid precipitation followed by neutralization) can help reduce matrix interference; confirm compatibility with the assay chemistry.
If you require a stand-alone buffer system, see our dedicated buffer products; for this kit, follow the supplied protocol to ensure assay performance.
Green Alternatives
For glycogen quantification workflows, greener practices focus on minimizing hazardous solvents, reducing waste, and optimizing energy use.
Opportunities for greener operation (general):
Miniaturization: Use 384-well or 1536-well formats to reduce reagent consumption and waste per data point.
Solvent reduction: Keep DMSO content to the minimum needed for probe solubilization; prepare concentrated stocks to limit volume. Substitute with water-miscible, less hazardous cosolvents only if compatible with the assay.
Energy conservation: Consolidate incubations at ambient or physiological temperatures when validated by the protocol, reducing heating/cooling demands.
Waste management: Segregate aqueous assay waste and avoid bleach when peroxidase-compatible probes are present; use appropriate, less hazardous disinfectants.
Comparative perspective (literature):
Fluorometric vs. colorimetric glycogen assays: Fluorometric methods often achieve lower LODs, allowing smaller sample/reagent volumes and thus less waste; however, fluorescent probes may be more light- and solvent-sensitive.
End-point vs. kinetic: End-point formats can minimize repeated reads and energy use; kinetic formats can reduce repeats by detecting drift/interference early—choose based on experimental goals.
Sourcing and packaging:
Prefer kits with concentrated buffers and recyclable packaging. For this item, specific packaging sustainability details are Not specified; check the product documentation.
Implement changes only after confirming compatibility with the assay chemistry.
Pharmaceutical Uses
This product is for research use only and is not intended for manufacturing or clinical applications.
Non-clinical laboratory uses (general):
Preclinical research on carbohydrate metabolism in cells and tissues to support exploratory studies.
Process development or QC in research settings where intracellular glycogen content serves as a process indicator for cell-based products (research context only).
Not applicable:
The kit is not an excipient, API, or pharmacopeial reagent. It has no compendial monograph and is not qualified for GMP lot release testing unless specifically validated by the user’s quality system.
Any adaptation for regulated environments would require user-led method validation (specificity, linearity, accuracy, precision, robustness) and documentation per the site’s quality procedures.
Physical Properties
As a multi-component kit, bulk physical constants are not defined for the product as a whole.
Item-specific properties:
Molecular Formula: Not applicable; Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not applicable for a kit; Not specified for this item; refer to CoA/Spec Sheet.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Storage Conditions (from Product Data): Store at -20°C.
Shipping: Ice chest + ice pads (cold chain).
Fluorometric readout (general/literature):
Many glycogen kits use excitation/emission in the green–orange region, for example Ex/Em ~530–540/585–600 nm when resorufin-type reporters are formed, or alternative wavelengths depending on the probe. Exact wavelengths for this item are Not specified; verify in the kit manual/SDS.
Solubility and buffers (general):
Reagents are typically supplied as lyophilized enzymes, aqueous buffers, and/or DMSO stock solutions for fluorogenic probes (literature). Actual solvent systems for this item are Not specified.
Stability considerations (general):
Enzymes and fluorescent probes are temperature- and light-sensitive; freeze at -20°C (or colder) and protect probes from light to minimize photobleaching and degradation (literature). Follow the product insert for aliquoting to reduce freeze–thaw cycles.
Note: Any specific numeric constants for individual kit components are Not specified for this item; refer to the CoA/Spec Sheet and SDS.
Quality and Grades
Item-specific grade (from Product Data): BioReagent, Suitable for Analysis, Colorimetry, Standard Curve Method.
What this means:
BioReagent: Components are suitable for biochemical workflows, including enzymatic reactions sensitive to trace contaminants.
Suitable for Analysis/Colorimetry: Formulated to support quantitative spectroscopic endpoints (here fluorometric), minimizing background and enabling reproducible calibration.
Standard Curve Method: Supplied to enable generation of a reliable calibration curve (e.g., using a glycogen or glucose standard), supporting quantitative determination of glycogen amounts in unknowns.
Practical implications for this kit:
Low background fluorescence and controlled enzyme activities are critical for linearity and sensitivity. The grade indicates attention to these parameters; however, specific acceptance limits and performance specifications are Not specified for this item; refer to CoA/Spec Sheet.
Batch-to-batch quality: For consistent analytical results, use the provided standard curve every run to normalize inter-run variation.
Documentation and verification:
For regulated labs, retain the CoA and, if available, a lot-specific performance sheet describing linear range, LOD/LOQ, and interference testing. These details are Not specified for this item and must be confirmed in the supplied documentation.
Stabilizers and preservatives:
The presence or absence of stabilizers/preservatives in enzyme or probe solutions is Not specified for this item; consult the kit insert for any additives that could affect certain applications.
Reaction and Applications
This fluorometric kit is designed for quantitative measurement of glycogen in biological samples for research use only.
Typical applications (general/literature):
Quantification of glycogen in cultured cells, tissues, and biofluids after appropriate extraction and deproteinization.
Metabolic studies of glycogenesis/glycogenolysis, including effects of nutrient status, hormones, or genetic perturbations in model systems.
Normalization in enzyme assays involving glycogen phosphorylase or synthase by independently quantifying substrate/product pools.
Screening workflows where sample throughput and sensitivity are critical (microplate-based formats).
Assay principle (general):
Enzymatic hydrolysis converts glycogen to glucose (e.g., amyloglucosidase action).
Glucose is subsequently oxidized by a detection enzyme system, generating a stoichiometric reporter for fluorometric quantitation.
Fluorescence intensity correlates with glycogen-derived glucose; a standard curve enables absolute quantification.
Practical tips (general):
Include “with/without hydrolysis” controls to distinguish free glucose background from glycogen-derived signal.
Validate linearity by spanning standards across the expected sample range; dilute samples to fall within the linear region.
Protect fluorescent probes from light; maintain consistent incubation times and temperatures to reduce inter-well variability.
Matrix effects: minimize protein, pigments, and detergents; consider sample cleanup steps if interference is suspected.
Note: Specific component identities, working concentrations, and instrument settings are Not specified for this item; consult the kit insert.
Reaction Conditions
The following are general, literature-based conditions for fluorometric glycogen assay workflows. They are provided as guidance and are not item-specific specifications.
Sample preparation (general):
Homogenize tissues/cells in ice-cold aqueous buffer; clarify by centrifugation.
Optional deproteinization (e.g., ultrafiltration or acid precipitation followed by neutralization) to reduce background.
Include parallel aliquots for “+hydrolysis” (total glycogen) and “–hydrolysis” (free glucose background).
Enzymatic hydrolysis and detection (general):
Incubate with glycogen-hydrolyzing enzyme at 37°C until complete conversion to glucose; duration commonly 20–60 minutes depending on matrix and enzyme load.
Add detection mix containing glucose-oxidizing enzyme system and fluorogenic probe; incubate protected from light until signal stabilizes (often 10–30 minutes at room temperature or 37°C).
Read fluorescence at probe-appropriate Ex/Em (e.g., green–orange region for resorufin-like reporters). Exact wavelengths for this item are Not specified; consult the kit insert.
Calibration and linearity (general):
Prepare a standard curve in the same buffer/matrix as samples; confirm linearity across the expected range.
Dilute samples to fall within the linear range and avoid inner-filter effects.
Controls:
Blank (no analyte), background (–hydrolysis), and positive controls (known glycogen) improve data quality and identify interference.
Instrument settings, reagent concentrations, and timing must be verified in the product documentation for this specific kit.
Safety and Handling
Always handle assay kits under standard laboratory safety practices; consult the SDS for each component for authoritative guidance.
Item-specific hazard data:
Signal Word: Not specified for this item; refer to SDS.
H-Statements: Not specified for this item; refer to SDS.
GHS Classification: Not specified for this item; refer to SDS.
Pictograms: Not specified for this item; refer to SDS.
General hazards for similar fluorometric assay kits (literature/general):
Fluorogenic probes may be dissolved in DMSO and can cause skin/eye irritation; avoid inhalation/ingestion.
Enzyme powders/lyophilizates can be respiratory sensitizers; avoid aerosol generation.
Peroxide-generating detection chemistries may produce trace H2O2 in situ; avoid contact with incompatible reductants and metals.
PPE and engineering controls:
Wear lab coat, nitrile gloves, and safety glasses or face shield.
Work with light-sensitive probes under low ambient light; use amber tubes/foil wrap.
Use a fume hood for handling volatile solvents (e.g., DMSO stocks) or powder components.
Incompatibilities and special precautions (general):
Keep enzymes and fluorophores cold; minimize freeze–thaw cycles.
Do not mix with strong oxidizers/reductants outside intended assay chemistry.
Dispose of assay waste as aqueous laboratory chemical waste per institutional policy.
First-aid overview (general):
Skin/eye contact: Rinse with water for ≥15 minutes; remove contaminated clothing.
Inhalation: Move to fresh air; seek medical attention if symptoms persist.
Ingestion: Rinse mouth; seek medical attention.
Defer to the SDS/kit insert for component-specific hazards and first-aid measures.
Solvent Selection
This product is an assay kit rather than a standalone solvent. Solvent choice primarily affects sample preparation, probe stability, and enzyme activity.
General guidance (literature):
Assay buffer: Use the kit-provided buffer to maintain optimal pH and ionic strength for the enzyme system. Alternative buffers may alter activity and background.
DMSO: Fluorogenic probes are often supplied in DMSO stocks; keep final assay DMSO ≤1–2% v/v to preserve enzyme activity (exact tolerance is assay-dependent; verify in the kit insert).
Aqueous compatibility: The enzymatic steps require aqueous conditions; avoid high organic content that can denature enzymes or quench fluorescence.
Sample extraction considerations:
For tissues/cells, ice-cold aqueous extraction buffers are typically used; deproteinization with PCA, TCA, or perchlorate-free alternatives can reduce background (method-dependent; verify compatibility with the kit protocol).
Avoid strong detergents or high salt that may inhibit enzymes or interfere with fluorescence.
When to choose alternatives:
If sample matrices contain intrinsic fluorescence or colored compounds, consider alternate emission windows or orthogonal detection (e.g., luminescent assays) to mitigate interference.
Note: Exact solvent tolerances, compatible detergents/salts, and pH windows are Not specified for this item; refer to the kit manual for authoritative guidance.
Storage and Reconstitution
Item-specific storage (from Product Data):
Store at -20°C.
Shipped in an ice chest with ice pads to maintain cold chain.
Light and moisture protection (general):
Protect fluorogenic probes from light by using amber vials or aluminum foil.
Keep desiccated where appropriate; reseal bottles/vials promptly after use.
Reconstitution (general guidance; not item-specific):
Equilibrate to 2–8°C before opening to minimize condensation.
Reconstitute lyophilized enzymes/buffers with nuclease-free water or assay buffer as directed in the kit insert.
Prepare concentrated stocks of fluorescent probes in DMSO (if appropriate) and aliquot to avoid repeated freeze–thaw cycles.
Handling and stability (general):
Avoid multiple freeze–thaw cycles; aliquot upon first thaw.
Maintain enzymes and probes on ice during setup; return promptly to -20°C after use.
Working solutions are typically stable for a limited time at 2–8°C; exact stability for this item is Not specified; consult the kit manual.
Documentation:
Record lot numbers, reconstitution dates, and storage conditions for traceability.
For definitive storage durations, component stability, and reconstitution volumes for this item, refer to the CoA/Spec Sheet and SDS.
Structure and Identity
This product is a multi-component analytical kit designed to quantify glycogen via a fluorometric readout. It does not correspond to a single defined chemical structure.
Category: Life Science research (research use only)
Grade/Purity (from Product Data): BioReagent, Suitable for Analysis, Colorimetry, Standard Curve Method
CAS, CID, InChIKey, SMILES: Not applicable to a kit; Not specified for this item; refer to CoA/Spec Sheet.
Typical kit constituents (general literature context):
Enzymatic glycogen hydrolysis reagent (e.g., amyloglucosidase or related).
Glucose detection enzyme system and a fluorogenic probe.
Glycogen or glucose standard for calibration.
Assay buffer(s).
Note: Exact components and concentrations are Not specified for this item; refer to the kit manual/CoA.
Structural features (general chemistry):
The analyte, glycogen, is a highly branched α(1→4)-linked glucose polymer with α(1→6) branch points approximately every 8–12 residues (literature). It lacks a single molecular formula due to polymeric nature and variable chain length.
Fluorogenic probes commonly used in similar assays produce a resorufin- or coumarin-like reporter upon enzymatic reaction (literature). Specific probe identity for this item is Not specified.
2D description (general): The analyte’s repeating D-glucopyranose units form a tree-like, branched polysaccharide; detection relies on enzymatic conversion to glucose followed by a reporter-generating oxidation step.
Synthetic Utility
Not typically applicable. This product is an analytical assay kit and is not used as a synthetic reagent or building block.
General note:
While the assay involves enzymatic and reporter-generating reactions, these are analytical transformations for quantitation rather than preparative chemistry.
For synthetic applications related to carbohydrates (e.g., glycosylations, protecting group strategies), consider our catalog of monosaccharides, glycosyl donors, and catalysts instead.
Target Specificity
Not applicable. This product is not an antibody, probe targeting a biomolecule epitope, nor a receptor/ligand screening reagent with defined target specificity. It quantifies glycogen via enzymatic conversion and fluorometric detection.
General analytical specificity (literature):
Specificity arises from selective enzymatic hydrolysis of glycogen to glucose and subsequent detection of glucose. Free glucose present in samples is accounted for by parallel background controls without the hydrolysis step.
No item-specific target-binding data are provided; refer to the kit manual for interference studies and specificity assessments, if available.
よくある質問
What does Suitable for Analysis mean?
Suitable for Analysis is a defined analytical purity tier suitable for quantitative analytical methods. It specifies a minimum assay percentage, controlled limits on common impurities (water, heavy metals, residue on ignition), and lot-to-lot consistency. Suitable for Analysis is one of several purity tiers — choose based on the sensitivity and regulatory requirements of your method.
What does BioReagent mean?
BioReagent indicates that the product has been processed and tested for biological and biochemical applications. Specifications may include endotoxin limits, microbial controls, sterility, low DNase/RNase/protease activity, and verified biological activity where relevant.
How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.