概要

Polyphenol Oxidase (PPO, EC1.10.3.1) is widely found in the plastids of plants, fungi, and insects. It is a copper-containing oxidase that can oxidize monophenols and diphenols to produce quinones, leading to browning. It is closely related to fruit and vegetable processing, tea quality, and tissue culture. The Plant Polyphenol Oxidase (PPO) Activity Assay Kit (Catechol, Micro method) provides a simple method to detect the activity level of polyphenol oxidase (PPO) in plant tissue samples.

Detection Principle: Polyphenol oxidase (PPO) in the sample catalyzes the oxidation of catechol to produce quinones, which have a characteristic absorption peak at 410 nm. The rate of increase in absorbance at 410 nm is measured to calculate PPO activity.

P1501774
Component
48T96TStorage
P1501774A
Extraction Buffer
60 mL120 mL
2-8℃
P1501774B
ReagentⅠ
24 mL48 mL2-8℃
P1501774C
ReagentⅡ
6 mL12 mL2-8℃. Store in the dark.

Note: Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.

User-Prepared Instruments and Reagents

  • Microplate reader or visible spectrophotometer (capable of measuring absorbance at 410 nm)

  • 96-well plate or micro glass cuvettes, adjustable micropipettes and tips

  • Refrigerated centrifuge, ice maker, constant temperature water bath

  • Deionized water

  • Homogenizer

Experimental Procedure

1. Reagent Preparation

Reagent Name
Reagent Preparation
Notes
Extraction Buffer
Ready-to-use; Equilibrate to room temperature before use.
Store at 4°C.
ReagentⅠ
Ready-to-use; Equilibrate to room temperature before use.
Store at 4°C.
ReagentⅡ
Ready-to-use; Equilibrate to room temperature before use.
Store at 4°C protected from light; Toxic, handle with care.

2. Sample Preparation

Note: Fresh samples are recommended. If not used immediately, samples can be stored at -80°C for one month.

2.1 Preparation of Crude Enzyme Extract

Homogenize the plant sample in ice-cold Extraction Buffer with a mass (g) to volume (mL) ratio of 1:5 to 1:10 (recommended: 0.1 g tissue + 1 mL Extraction Buffer). Centrifuge the homogenate at 8,000 g, 4°C for 10 minutes. Collect the supernatant and keep it on ice for assay.

2.2 Boiled Sample Control

Take an appropriate amount of the crude enzyme extract and heat it in a boiling water bath for 5 minutes (seal to prevent moisture loss). Cool to room temperature.

3. Assay Steps

3.1 Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 410 nm. For spectrophotometers, zero the instrument with deionized water.

3.2 Sample Measurement (Add reagents sequentially into 1.5 mL microcentrifuge tubes):

ReagentControl Tube (μL)Test Tube (μL)
Boiled Sample500
Sample (supernatant)050
ReagentⅠ
200200
ReagentⅡ
50
50

3.3 Mix thoroughly, then incubate in a 25 °C water bath for 10 min, followed immediately by incubation in a boiling water bath for 10 min. After mixing, centrifuge at 5,000 × g at 25 °C for 10 min.

3.4 Absorbance measurement: Transfer 200 μL of the supernatant to a 96-well plate and measure the absorbance at 410 nm. Record the values as Acontrol and Asample (or Atest), respectively.

Note:

  • Each test tube requires a corresponding control tube.

  • It is recommended to perform a preliminary test with 2-3 samples expected to have significant differences before the formal experiment.

  • The optimal reaction temperature for PPO may vary slightly among different samples and can be adjusted between 25-37°C.

4. Calculation of Results

Note: We provide both the derived formula and a simplified formula. They are equivalent. It is recommended to use the simplified formula in bold for final calculation.

1. Data ProcessingCalculate ΔA = Asample − Acontrol.

2. Calculation of Sample PPO Activity

Calculation based on sample weight

Unit definition: One unit of enzyme activity is defined as the amount of enzyme that causes a 0.005 change in absorbance at 410 nm per minute per gram of tissue in each mL of reaction system.

PPO (U/g) = ΔA × Vtotal‑rxn ÷ (W × Vsample ÷ Vtotal‑sample) ÷ 0.005 ÷ T = 120 × ΔA ÷ W
Calculation based on protein concentration
Unit definition: One unit of enzyme activity is defined as the amount of enzyme that causes a 0.005 change in absorbance at 410 nm per minute per milligram of tissue protein in each mL of reaction system.
PPO (U/mg prot) = ΔA × Vtotal‑rxn ÷ (Vsample × Cpr) ÷ 0.005 ÷ T = 120 × ΔA ÷ Cpr
Vtotal‑rxn: Total volume of reaction system, 0.3 mL; 
Vsample: Volume of added sample, 0.05 mL; 
Vtotal‑sample: Volume of added Extraction Buffer, 1 mL;

T: Reaction time, 10 min; 

W: Sample weight, g; 

Cpr: Protein concentration (mg/mL).

Result Presentation

Example‑1: Weigh 0.1 g blueberry, perform the assay according to the test procedure, and detect with a 96‑well plate. Obtained ΔA = Asample − Acontrol = 0.349 − 0.261 = 0.088.
Calculated by sample weight: PPO (U/g) = ΔA × Vtotal‑rxn ÷ (W × Vsample ÷ Vtotal‑sample) ÷ 0.005 ÷ T = 120 × ΔA ÷ W = 105.6 U/g. 
FAQ 
 What should I do if the measured Asample value is too high or too low? If Asample>1, the PPO activity of the sample is excessively high. Dilute the sample appropriately with Extraction Buffer and re‑measure, or reduce the sample weight for extraction. If Asample<0.02, increase the sample amount properly.

Precautions

This product is for research use only. Not for use in clinical diagnosis. For your safety and health, please wear lab coats and disposable gloves during operation.

仕様

仕様と純度
BioReagent
等級
BioReagent
アプリケーション
Cell Metabolism, Enzyme activity assay
感度
Light-sensitive
保管と配送
保管条件
Store at 2-8°C,Protected from light
入荷
Wet ice
安定性と保管
Store at 2-8℃ long term (12 months). Store in the dark.

ドキュメント

📋 安全データシート(SDS)

危険性、取扱い、保管、および規制遵守を網羅した包括的な文書。

<<<<<<< HEAD SDS をダウンロード → ======= SDS をダウンロード → >>>>>>> release248-p3

✅ 分析証明書(COA)

ロット固有の品質データ。ロット番号を入力して、正確な COA を取得してください。

COA を検索 →

📊 データシート

製品仕様と用途のクイックリファレンス概要。

データシートを見る →

🔬 仕様書

このグレードの完全な品質特性と合格基準。

仕様書を見る →

詳細データ

証明書(CoA、COO、BSE/TSEと分析図)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
よくある質問と記事
ソリューション計算機
レビュー

顧客レビュー

グレードの選択でお困りですか?

当社のグレード選定ガイドでは、カタログ内のすべてのバリエーションについて、純度、安定剤の状態、用途への適合性を網羅しています。

BioReagent グレードガイドを見る →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.