Rapid Plasmid Mini Kit

Cat. No.: P1521035
注文可能
グレード&純度 BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Suitable for molecular biology ? Molecular-biology grade — free of nucleases and contaminants that degrade DNA/RNA. Use in cloning, PCR, and nucleic-acid work needing clean reagents.
★
サイズ
USA
ドイツ (EU)*
価格
個数
100T
P1521035-100T
US製・受注生産 · 2~4週間 ·
—
$69.90
Enter a quantity for the sizes you want to add.
🧪
このグレードを選ぶ理由

BioReagent,Suitable for molecular biology BioReagent,Suitable for molecular biology ベースライン干渉を最小限に抑える必要がある、感度の高いクロマトグラフィーおよび分析ワークフロー向け。

🌡

保管・配送

Room temperature Normal に出荷。正確な仕様については、ロット固有の COA をご確認ください。

📋

品質書類

SDS、COA、データシート、仕様書をダウンロードできます。ロット固有の COA はロット番号検索で入手可能です。

📚

文献的裏付け

クロマトグラフィー、有機合成、クロスカップリング反応に関する 0 件の査読済み論文で引用されています。

概要

This kit employs a modified SDS-alkaline lysis method to lyse cells. The silica membrane within the centrifugal spin column selectively binds plasmid DNA in the solution under high-salt, low-pH conditions. Impurities and other bacterial components are then removed using a wash solution. Finally, the purified plasmid DNA is eluted from the silica membrane using a low-salt, high-pH elution buffer.

Product Features

  1. The silica membrane inside the centrifugal spin column is made entirely of imported specialty membrane, ensuring minimal variation in binding capacity between columns and excellent reproducibility. This overcomes the instability issues associated with the membrane quality of domestic kits.

  2. Fast and convenient; no need for toxic reagents such as phenol or chloroform, nor ethanol precipitation. The obtained plasmid DNA has high yield and purity, making it suitable for various molecular biology experiments including restriction enzyme digestion, transformation, PCR, in vitro transcription, and sequencing.

Precautions

  1. First-time use: Add the entire vial of RNase A (powder) to Solution P1 (final concentration 100 μg/mL) and store at 2-8°C. If RNase A in Solution P1 becomes inactivated, trace RNA residues may appear in the extracted plasmid; add additional RNase A to Solution P1 to remedy this.
  2. When ambient temperature is low, SDS in Solution P2 may precipitate, causing cloudiness. Warm at 37°C for a few minutes until clear. Do not shake vigorously to avoid excessive foaming.

  3. Avoid prolonged exposure of reagents to air to prevent volatilization, oxidation, and pH changes.

  4. This kit is suitable for endA-deficient strains such as XL-1Blue and DH5α. For endA+ strains like JM series, HB101, or wild-type strains which contain high levels of nucleases, please use our [H1521033] High Purity Rapid Plasmid Miniprep Kit.

  5. Solution P3 contains irritating compounds. Wear latex gloves during operation. Avoid contact with skin, eyes, and clothing. In case of contact, rinse thoroughly with copious amounts of water or saline. 

  6. The amount of extracted plasmid depends on factors such as bacterial culture concentration and plasmid copy number. For high-copy plasmids, inoculate a single colony into 1.5-4.5 mL of LB medium containing the appropriate antibiotic and culture overnight for 14-16 hours; up to 20 µg of pure plasmid can be extracted. For low-copy plasmids or large plasmids >10 kb, increase the amount of bacterial culture (use 5-10 mL of overnight culture) and proportionally increase the volumes of P1, P2, and P3, while keeping other steps the same.

  7. The yield and purity of the extracted plasmid DNA can be analyzed by agarose gel electrophoresis and UV spectrophotometry. An OD260 value of 1 corresponds to approximately 50 μg/mL DNA. Electrophoresis may show a single band, or two or more DNA bands, primarily due to different migration positions of various supercoiled plasmid conformations, influenced by factors like culture duration and handling intensity during extraction. Under normal operating conditions with this product, supercoiled forms typically exceed 90%.

  8. Elution Buffer EB does not contain the chelator EDTA and does not interfere with downstream enzymatic reactions like restriction digestion or ligation. Deionized water can also be used for elution, but ensure the pH is >7.5; low pH reduces elution efficiency. Plasmids eluted with water should be stored at -20°C. For long-term storage, TE buffer (10 mM Tris-HCl, 1 mM EDTA, pH 8.0) can be used for elution; however, EDTA may affect downstream enzyme reactions, so dilution may be necessary when used.

  9. For research use only. Not intended for clinical diagnosis or other applications.

Materials Required but Not Supplied

  • Anhydrous ethanol

Protocol

Notes:

  • Before first use, add 100 mL of anhydrous ethanol to the Wash Buffer WB bottle. Mix thoroughly. Immediately mark the bottle to indicate ethanol has been added to avoid adding it multiple times!

  • Pour the RNase A (powder) into Solution P1, rinse the RNase A vial with P1 to ensure complete transfer, and mix well. Store at 2-8°C after each use.

  • Pre-cool Solution P3 on ice before use to improve yield.

  1. Harvest bacteria: Centrifuge 1.5 - 4.5 mL of overnight bacterial culture at 12,000 rpm for 30 seconds. Remove the supernatant as completely as possible.

  2. Resuspend: Resuspend the bacterial pellet thoroughly in 250 μL of Solution P1 by vortexing until no clumps remain.

  3. Lyse: Add 250 μL of Solution P2. Gently invert the tube 4-7 times to lyse the cells completely.

  4. Neutralize: Add 350 μL of Solution P3. Immediately and gently invert the tube 4-7 times until a white flocculent precipitate forms. Centrifuge at 12,000 rpm for 5 minutes. Carefully transfer the supernatant to a new tube/column.

  5. Bind: Transfer the supernatant from the previous step into the Spin Column AC (placed in a collection tube). Centrifuge at 12,000 rpm for 30-60 seconds. Discard the flow-through in the collection tube.

  6. Wash 1: Add 500 μL of Wash Buffer WB (ensure ethanol has been added). Centrifuge at 12,000 rpm for 30 seconds. Discard the flow-through.

  7. Wash 2: Repeat step 6.

  8. Dry: Place the Spin Column AC back into the empty collection tube. Centrifuge at 12,000 rpm for 2 minutes to remove residual wash buffer, preventing ethanol carryover that could inhibit downstream reactions.

  9. Air dry: Transfer the Spin Column AC to a clean 1.5 mL microcentrifuge tube. Allow the column to air dry for several minutes at room temperature.

  10. Elute: Add 50-100 μL of Elution Buffer EB (pre-heating the buffer to 65-70°C improves elution efficiency) directly onto the center of the silica membrane. Let stand at room temperature for 2 minutes. Centrifuge at 12,000 rpm for 1 minute. For higher yield, re-apply the eluate to the spin column and repeat the centrifugation step. A larger elution volume increases yield. To obtain a higher concentration of plasmid, reduce the elution volume, but do not use less than 30 μL, as smaller volumes reduce elution efficiency and yield. If using ddH₂O for elution, ensure the pH is within the range of 7.0-8.5; pH below 7.0 will reduce elution efficiency.

仕様

同義語
Plasmid Mini Rapid Extraction Kit | Rapid Mini Plasmid Kit
仕様と純度
BioReagent,Suitable for molecular biology
等級
BioReagent, Suitable for molecular biology
アプリケーション
DNA Extraction
サンプルタイプ
保管と配送
保管条件
Room temperature
入荷
Normal
安定性と保管
Store at room temperature long term (18 months).
Contents & Storage
P1521035
Component
100T
Storage
P1521035A
RNase A (powder)
1 EA
RT.
P1521035B
Solution P1
30 mL
RT.
P1521035C
Solution P2
30 mL
RT.
P1521035D
Solution P3
40 mL
RT.
P1521035E
Wash Buffer WB
25 mL
RT.
P1521035F
Elution Buffer EB
10 mL
RT.
P1521035G
Spin Column AC
1 EA×100
RT.
P1521035H
Collection Tubes (2 ml)
1 EA×100
RT.

The kit can be stored at room temperature for 18 months without affecting performance.

ドキュメント

📋 安全データシート(SDS)

危険性、取扱い、保管、および規制遵守を網羅した包括的な文書。

<<<<<<< HEAD SDS をダウンロード → ======= SDS をダウンロード → >>>>>>> release248-p3

✅ 分析証明書(COA)

ロット固有の品質データ。ロット番号を入力して、正確な COA を取得してください。

COA を検索 →

📊 データシート

製品仕様と用途のクイックリファレンス概要。

データシートを見る →

🔬 仕様書

このグレードの完全な品質特性と合格基準。

仕様書を見る →

詳細データ

証明書(CoA、COO、BSE/TSEと分析図)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate Type日付商品
ZJ26F0636131ZJ26F0636131Certificate of AnalysisJun 08, 2026 P1521035
よくある質問と記事
ソリューション計算機
レビュー

顧客レビュー

よくある質問

What does Suitable for molecular biology mean?
Suitable for molecular biology indicates that the product has been processed and tested for molecular biology and proteomics. Typical specifications include low or undetectable nuclease/protease activity, low endotoxin, controlled microbial limits and high lot-to-lot reproducibility.
What does BioReagent mean?
BioReagent indicates that the product has been processed and tested for biological and biochemical applications. Specifications may include endotoxin limits, microbial controls, sterility, low DNase/RNase/protease activity, and verified biological activity where relevant.
How should this product be stored?
Store at room temperature.
How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

グレードの選択でお困りですか?

当社のグレード選定ガイドでは、カタログ内のすべてのバリエーションについて、純度、安定剤の状態、用途への適合性を網羅しています。

Suitable for molecular biology グレードガイドを見る → BioReagent グレードガイドを見る →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.