YQ128 is a potent and selective second-generation NLRP3 (NOD-like receptor P3) inflammasome inhibitor with an IC50 of 0.30 µM. YQ128 significantly and selectively suppresses the production of IL-1β, but not TNF-α, and it can cross the BBB to reach the CNS. YQ128 has anti-inflammatory activity.
This compound belongs to the class of organic compounds known as benzenesulfonamides. These are organic compounds containing a sulfonamide group that is S-linked to a benzene ring.
External Descriptors
Not available
1. Djoumbou Feunang Y, Eisner R, Knox C, Chepelev L, Hastings J, Owen G, Fahy E, Steinbeck C, Subramanian S, Bolton E, Greiner R, and Wishart DS. ClassyFire: Automated Chemical Classification With A Comprehensive, Computable Taxonomy. Journal of Cheminformatics, 2016, 8:61.
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
レビュー
顧客レビュー
Application Protocols
Item-specific facts (from Product Data)
No tested application protocols are provided for YQ128.
General small-molecule handling protocols
DMSO stock preparation: Weigh under dry conditions, dissolve to 10–50 mM in anhydrous DMSO, vortex/sonicate briefly, and filter if necessary (PTFE, 0.2 µm). Aliquot to avoid repeated freeze–thaw.
Plate handling: Use low-bind polypropylene plates or tubes. Seal with solvent-resistant films. Allow temperature equilibration to minimize condensation.
Serial dilution: Use intermediate DMSO plates to maintain consistent DMSO across the assay. Mix thoroughly at each step to avoid well-to-well variability.
Analytical QC: Record retention time in two LC methods, MS spectrum, and purity before biological testing; re-check after the assay window to assess stability.
Biological Roles
Item-specific facts (from Product Data)
No biological function or target information is provided for YQ128.
General considerations
As a small-molecule library member, YQ128 may be evaluated as a test article in biochemical or cell-based assays. No endogenous biological role can be asserted without structure and target data.
To prevent misinterpretation in screening, apply orthogonal readouts and counter-assays to identify fluorescence interference, redox cycling, colloidal aggregation, or membrane perturbation as potential assay artifacts.
Recommendations
If a target pathway is hypothesized, measure basic physicochemical parameters (solubility, stability in assay buffer/serum, permeability via PAMPA/MDCK, and nonspecific binding to plastics/proteins) before potency comparisons.
Record exact batch/lot, storage history, and freeze–thaw count; biological readouts are sensitive to subtle degradation.
Buffer Applications
Not typically applicable
YQ128 is listed as a small-molecule library member rather than a buffering agent. No pKa or buffering capacity data are available.
Practical note
If the compound must be formulated into aqueous buffers for biological assays, adjust pH with standard buffers (e.g., PBS, HEPES) and keep organic co-solvent levels minimal and constant across controls. Determine compound stability in the chosen buffer by LC–MS.
Green Alternatives
Context
Without structure-specific data, solvent and process choices are the main levers for improving sustainability when handling small-molecule libraries.
General greener choices and tradeoffs
Replace DMF/NMP where possible with ethanol, isopropanol, 2-propanol/water mixtures, or acetonitrile for chromatography; for reaction media (if applicable), consider 2-MeTHF, CPME, EtOAc, propylene carbonate, or water/biobased solvents when chemistry permits.
DMSO is widely used for stocks; it is relatively benign but has high water miscibility and facilitates dermal transport—maintain strict PPE.
Comparison (general, not item-specific)
Solvent | Greener profile | Notes
2-MeTHF | Bio-based, lower peroxide risk than THF | Immiscible with water; good for many organometallics
CPME | Low peroxide formation, wider liquid range | Hydrophobic; good extraction solvent
EtOAc | Low toxicity, biodegradable | Limited polarity; good for workups
Ethanol | Renewable, low toxicity | Can affect biological assays at >1–2% v/v
Implementation tips
Minimize solvent volumes via microplate-based assays and acoustic dispensing.
Use sealed microvials/plates to reduce evaporative losses and VOC exposure.
Plan solvent recovery for preparative purifications where feasible.
Pharmaceutical Uses
Not applicable to this listing
No pharmacopeial status, excipient role, or formulation use is provided. The product is designated For research use only and is not intended for human or veterinary use.
General guidance (for formulation R&D contexts only)
If exploratory formulation is required for preclinical research, assess solubility/permeability via enabling vehicles (e.g., cyclodextrins, lipid emulsions) only after confirming compound identity and purity. Document all vehicles and concentrations in ELNs.
Physical Properties
Item-specific facts (from Product Data)
Physical state/appearance: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Melting point, boiling point, density, refractive index, logP/logD, pKa, UV cutoff: Not specified for this item; refer to CoA/Spec Sheet.
Literature/general guidance for small-molecule library members (not specific to this item)
Solubility screening: begin with DMSO at 10–50 mM stock; if insoluble, consider DMF or a co-solvent system (DMSO:water, 1:1 to 1:9). Gentle warming (≤37 °C) and brief ultrasonication can assist dissolution.
Hygroscopicity and polymorphism can impact apparent melting point and solubility. Verify by DSC/TGA and Karl Fischer where relevant.
If UV detection is planned (HPLC/UPLC), record the compound’s UV spectrum (200–400 nm). Unknowns often exhibit absorbance between 210–230 nm; do not assume a strong chromophore.
Measurement recommendations
Determine aqueous kinetic solubility (e.g., nephelometry or HPLC after filtration) at target pH values.
If LC–MS analytics are required, first capture full-scan ESI± spectra to establish expected m/z before quantitation.
Quality and Grades
Item-specific facts (from Product Data)
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Guidance on grades and characterization (general)
For screening compounds, typical QC packages include: purity by HPLC/UPLC (area %), identity by LC–MS and/or 1H NMR, and water content by Karl Fischer. If your workflow is bioassay-sensitive, request low-residual solvent data and counter-ion/stoichiometry confirmation.
Analytical/Research grade implies suitability for general lab research. HPLC grade refers to solvents; for solids, “>95%” or “>98%” purity claims are more relevant. Low-UV impurity profiles are essential for chromatographic detection.
Stabilizers: None indicated for this item. If stability issues are suspected (e.g., hydrolysis, oxidation), consider storing under inert atmosphere and minimizing freeze–thaw cycles.
Best practices
Verify purity upon receipt, especially for SAR-sensitive campaigns. Record lot-specific CoA in ELN and label tubes/plates with lot and concentration.
If the compound is used for reference standards, orthogonal identity confirmation (HRMS + NMR) is recommended.
Reaction and Applications
Item-specific facts (from Product Data)
Manufacturer applications: Not specified in the listing.
General applications for small-molecule library members
Screening and hit-finding: Use as a test article in biochemical, cell-based, or biophysical assays. Prepare serial dilutions from concentrated DMSO stocks and maintain consistent final solvent fractions across control and test wells.
Analytical characterization: Build an internal reference file including retention time (two orthogonal LC methods if possible), MS fragmentation patterns, and preliminary UV spectrum. This supports later dereplication and stability monitoring.
Stability assessment: Conduct freeze–thaw cycling (e.g., 5 cycles) with LC–MS to monitor for degradation or adduct formation. Assess bench-top stability for typical assay windows (2–8 h at room temperature in assay media).
Counter-screening: If activity is observed, perform aggregation and redox interference controls (detergent supplementation, dynamic light scattering, and redox reporter assays) to rule out assay artifacts common to some small molecules.
Notes
No specific synthetic or named-reaction roles can be asserted without structural information. If this compound will be used as a starting material, obtain the full structure and reactivity profile first.
Reaction Conditions
No reaction-condition guidance can be provided for YQ128 without structural information.
General recommendations
When using an unknown small molecule in synthesis or derivatization, run micro-scale condition screens, varying solvent (polar aprotic vs protic), temperature (0–100 °C as appropriate), and catalyst/base/acid loadings.
Track progress by LC–MS/UPLC with gradient elution; collect mass balance and impurity profiles to assess stability.
Establish a quench and workup protocol that avoids degradation (e.g., mild aqueous workups, rapid drying, minimal heat) until stability is characterized.
Safety and Handling
Item-specific facts (from Product Data)
Storage: Store at -20 °C.
Shipping: Ice chest + ice pads.
GHS classification, signal word, pictograms, H-statements: Not specified for this item; refer to SDS.
General laboratory precautions (not specific to this item)
Handle in a chemical fume hood. Avoid inhalation of dusts/aerosols and contact with skin/eyes.
PPE: lab coat, safety glasses or face shield, and appropriate chemical-resistant gloves (nitrile typically suitable for most organics). Change gloves regularly.
Incompatibilities: Unknown for this specific item. Until known, keep away from strong oxidizers/reducers, strong acids/bases, and sources of ignition. Do not mix with reactive metals.
First aid (overview; defer to SDS): Inhalation—move to fresh air; Skin—wash with soap and water; Eyes—rinse cautiously with water for several minutes and seek medical attention if irritation persists; Ingestion—rinse mouth, seek medical advice.
Spill response: Absorb with inert material (e.g., vermiculite), collect in a chemical waste container. Avoid environmental release.
Waste disposal: Collect as organic chemical waste; follow institutional and local regulations.
Notes
Absent explicit hazard data, treat as a potentially harmful small molecule. Consult the product SDS for authoritative hazard classification before scaling or aerosol-generating operations.
Solvent Selection
Item-specific facts (from Product Data)
No item-specific solubility data provided.
General solvent strategy for unknown small molecules
Primary stock solvent: DMSO is the default for screening libraries due to broad solubilizing power and assay compatibility up to 0.1–1% v/v.
Secondary options: DMF, ethanol, isopropanol, acetonitrile. For water-compatible workups, consider co-solvent systems (e.g., DMSO:water or ACN:water) and pH adjustment if ionizable groups are later confirmed.
Solubility testing workflow:
Attempt 10 mM in dry DMSO at ambient temperature; vortex and sonicate briefly.
If opaque or precipitated, heat gently to 37 °C and re-assess.
If still insoluble, step down to 1–5 mM or switch to DMF or EtOH, then back-spike into DMSO.
For aqueous buffers, add the organic stock to buffer with vigorous mixing; keep final DMSO ≤1% if biologically tested.
Chromatographic considerations: For LC–MS, ACN:water with 0.1% formic acid (ESI+) or 5–10 mM ammonium acetate (ESI−) is broadly applicable. Avoid buffers that suppress ionization unless necessary.
Comparison (general)
DMSO vs DMF: DMSO is less volatile and generally more assay-compatible; DMF can improve solubility but has a stronger odor and higher toxicity profile.
Storage and Reconstitution
Item-specific facts (from Product Data)
Storage: Store at -20 °C.
Shipping: Ice chest + ice pads.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
General guidance (not item-specific)
Upon receipt: Allow container to reach room temperature in a desiccator before opening to prevent moisture condensation. If shipped cold, inspect for condensation or vial damage.
Long-term storage: Keep tightly sealed, protected from light and moisture. If sensitive, consider storing under inert gas (argon/nitrogen). Avoid frequent freeze–thaw by preparing single-use aliquots.
Reconstitution: For screening use, dissolve in anhydrous DMSO to prepare a concentrated stock (e.g., 10–50 mM). If aqueous use is required, dilute the DMSO stock into buffer with vigorous mixing, keeping final DMSO consistent across samples.
Stability monitoring: Periodically verify purity by LC–MS or HPLC, especially after 6–12 months of storage or multiple freeze–thaw cycles.
Research use note
For research use only. Not for human or veterinary use.
Structure and Identity
Item-specific facts (from Product Data)
Product name: YQ128 (SKU: Y420012)
CAS: 2454246-18-3
PubChem CID: 139600339
InChIKey: 334729 (as provided; note this is an atypical format — verify on CoA/SDS)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Interpretive notes (general)
Category: Small-molecule/compound library member (screening compound). Detailed structural features (functional groups, ring systems, stereochemistry) are not provided in the current listing.
Without a structure or formula, derived properties (e.g., exact heteroatom count, H-bond donors/acceptors, rotatable bonds) cannot be asserted. Obtain structure from the CoA/Spec Sheet or the cited CAS/CID and cross-verify.
Practical guidance
If using for screening or assay development, request structural disclosure (SMILES/SDF) and ensure it matches the CAS and CID on internal databases prior to computational or medicinal chemistry work.
For cheminformatics, preferred identifiers: canonical SMILES, InChI, and a verified InChIKey; embed these in ELNs and plate maps once available.
Synthetic Utility
Not enough structural information is available to discuss synthetic transformations specific to YQ128.
General notes
If YQ128 is intended as a building block or intermediate, obtain the full structure (SMILES/InChI) and verify functional groups. Then consult reactivity guides for those motifs (e.g., aryl halides for cross-coupling, carboxylic acids for amide coupling, aldehydes/ketones for reductive amination).
Prior to scale-up synthesis that uses YQ128, confirm compatibility with bases, acids, oxidants/reductants, and common catalysts through small-scale scouting experiments.
Target Specificity
Item-specific facts (from Product Data)
No target, pathway, or selectivity data are provided for YQ128.
Guidance
For hit validation, pursue target deconvolution strategies such as thermal shift assays, CETSA, chemical proteomics (if tagging is feasible), or orthogonal biochemical assays. Avoid making claims of specificity without direct evidence.
よくある質問
What is the purity of this product?
This product is supplied at ≥98% purity (chemical assay). Lot-specific values are stated on the Certificate of Analysis.
How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 2454246-18-3, the molecular formula is C27H29ClN2O4S2, and the molecular weight is 545.11 g/mol. InChIKey SFPYRFRNYALLHS-UHFFFAOYSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.