Aluminum Etchant Type A

Cat. No.: A487579
Disponibile su ordine
Synonyms
Aluminum etching solution for use on silicon devices
Storage
Room temperature
Shipped In
Normal
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
100ml
A487579-100ml
Su ordinazione · 8–12 settimane
69,33€
500ml
A487579-500ml
Su ordinazione · 8–12 settimane
227,26€
Enter a quantity for the sizes you want to add.

Panoramica

ALUMINUM ETCHANT - TYPE A
Standard aluminum etchant for use on silicon devices and other microelectronic applications.
Aluminum etchants are stable, non-toxic preparations used to etch aluminum metallizations on silicon devices and in integrated circuit applications. Aluminum contacts are defined, and interconnections are formed. These aluminum etchants, formulated with unique properties, easily overcome many of the difficulties experienced in aluminum etch processes.
The aluminum metallization and etching process using photo-lithographic techniques is basic to semiconductor and microelectronic technology. Aluminum etchants are highly compatible with commercial photoresists and permit delineation into high resolution patterns. Metal line width of 1 mil and separations less than 5 microns are feasible. High resolution is practical with these aluminum etchants because lifting of photoresist patterns does not occur and undercutting is minimized. Furthermore, the etchants do not attack silicon, silicon dioxide, silicon nitride or nichrome resistor films.
Two aluminum etchants are offered for use in microelectronics. Type A is recommended for use on silicon devices. Type D is recommended for use on gallium arsenide and gallium phosphide devices to avoid attack of the etchant on the intermetallic compound. It is also recommended for etching aluminum metallizations on nichrome thin film resistors.
Features and Benefits
Controlled etch rates
Selective etching: will not attack SiO2 or Si3N4
Offers high resolution with minimal undercutting
Eliminates smut formation
Economical; reusable
Purpose
Aluminum metallizations up to 25,000 Å are vacuum deposited on the silicon slice, coated with a photoresist, and UV exposed using an appropriate photographic mask. The resist is developed to protect the aluminum where interconnections are desired. Then the unprotected areas of the aluminum are removed by etching with the aluminum etchant, followed by a water rinse.
Etching time is dependent upon the etchant temperature and the aluminum film thickness. When etching thick aluminum films, a higher etch rate is required; thus a higher etchant temperature should be used. Likewise, for thinner aluminum films, slower etch rates are desired and a lower etchant temperature should be chosen.
At a specific etchant temperature, the etching time is given by the following formula:
Etching time (second) + Film Thickness (Å)/ Etch Rate (Å/sec)
where Etch Rate at 25°C 30 Å/sec; at 40°C 80 Å/sec.

Specifiche

Sinonimi
Aluminum etching solution for use on silicon devices
Condizioni di conservazione di stoccaggio
Room temperature
Spedito in
Normal

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate TypeDataOggetto
E2629259E2629259Certificate of AnalysisFeb 07, 2026 A487579
E2629261E2629261Certificate of AnalysisFeb 07, 2026 A487579
Sicurezza e pericoli (GHS)
Segnale
Danger
Indicazioni di pericolo

H226:Flammable liquid and vapor

H290:May be corrosive to metals

H302:Harmful if swallowed

H314:Causes severe skin burns and eye damage

Precauzioni

P210:Keep away from heat, hot surface, sparks, open flames and other ignition sources. - No smoking.

P280:Wear protective gloves/protective clothing/eye protection/face protection.

P301+P330+P331:IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.

P303+P361+P353:IF ON SKIN (or hair): Take off Immediately all contaminated clothing. Rinse SKIN with water [or shower].

P301+P312+P330:IF SWALLOWED: Call a POISON CENTER/ doctor if you feel unwell. Rinse mouth.

P305+P351+P338+P310:IF IN EYES: Rinse cautiously with water for several minutes. If contact lenses are worn and can be easily removed, remove Contact lenses. Continue rinsing. Immediately call an emergency center/doctor.

Domande frequenti e articoli
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Domande frequenti

How should this product be stored?
Store at room temperature.
How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.