Determine the necessary mass, volume, or concentration for preparing a solution.
Glycogen staining is one of the routine staining methods in pathology. In 1946, McManus was the first to use the periodic acid-Schiff (PAS) technique to demonstrate mucin. This method is commonly used to demonstrate glycogen and other polysaccharides. This staining kit can demonstrate not only glycogen, but also neutral mucinous substances, certain acidic substances, as well as cartilage, pituitary gland, mold, fungi, pigments, amyloid substances, basement membranes, etc. The PAS technique is the only method capable of detecting different types of mucinous substances (such as glycogen, mucin, and glycoprotein), but the PAS technique cannot distinguish between mucin and glycogen. To accurately identify mucinous substances (such as mucin or glycogen), a glycogen digestion step is required. In most cases, α-amylase or malt amylase can be used to catalyze the hydrolysis of glycosidic bonds in glycogen to form the water-soluble disaccharide, maltose, thereby removing glycogen from tissue sections prior to the application of the PAS technique.
Amylase aqueous solution (1%, pH 5.3) is composed of amylase and phosphate, and is mainly used for section treatment prior to glycogen PAS staining. Glycogen digestion requires two identical sections. After dewaxing, one section is treated with α-amylase aqueous solution, while the other is treated only with PBS or distilled water. Both sections are then stained using the PAS method. The disappearance of staining after digestion indicates the presence of glycogen.
Instructions for Use:
1.Take two identical sections, dewax with xylene, and hydrate through a graded ethanol series to water.
2.Treat one section with the amylase solution. Do not treat the other section with the amylase solution; instead, keep it in water as a control.
3.Rinse both sections under running water.
4.Proceed with the glycogen PAS staining procedure.
Precautions:
1.Sections should be dewaxed as thoroughly as possible; otherwise, the staining effect will be affected.
2.A positive control section must be used to verify the enzyme activity.
3.Avoid excessive exposure to sunlight and air. It is best to take the product out in advance and allow it to reach room temperature before use, and use it in a dark place protected from light.
4.The staining time for frozen sections should be as short as possible.
5.For your safety and health, please wear a laboratory coat and disposable gloves during operation.
Find and download the COA for your product by matching the lot number on the packaging.
| Lot Number | Certificate Type | Data | Oggetto |
|---|---|---|---|
| Certificate of Analysis | Nov 18, 2026 | S774827 |
La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.
Visualizza la guida alle qualità BioReagent → Visualizza la guida alle qualità Biological Stain → Visualizza la guida alle qualità for Microscopy →