attribute_line_ids/value_ids

Cat. No.: H1509762
Disponibile su ordine
QUALITÀ & PUREZZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
96T
H1509762-96T
Su ordinazione · 8–12 settimane
520,56€
Enter a quantity for the sizes you want to add.

Panoramica

This kit employs a sandwich enzyme-linked immunosorbent assay (ELISA) for the quantitative detection of Human Adiponectin/Acrp30 concentration in samples. The Human Adiponectin/Acrp30 capture antibody is pre-coated onto the microtiter plate. Upon addition of samples or standards, Human Adiponectin/Acrp30 present therein binds to the immobilized capture antibody, while other unbound components are removed through washing. Subsequently, a biotin-conjugated detection antibody specific for Human Adiponectin/Acrp30 is added. This antibody binds to the captured Human Adiponectin/Acrp30, forming a "sandwich" immunocomplex. Any excess, unbound material is again removed by washing. Next, an enzyme conjugate (typically Streptavidin-Horseradish Peroxidase, SA-HRP) is added. The biotin on the detection antibody and streptavidin on the enzyme conjugate exhibit high-affinity binding, thereby linking the HRP enzyme to the immunocomplex. Following another wash step to remove unbound conjugate, a colorimetric substrate (e.g., TMB) is added. If Human Adiponectin/Acrp30 is present in the sample, the HRP linked to the complex catalyzes the oxidation of the colorless substrate, yielding a blue product. The reaction is then stopped by adding a stop solution (usually an acid), which changes the color from blue to yellow. The optical density (OD) of each well is measured at 450 nm using a microplate reader. The concentration of Human Adiponectin/Acrp30 is directly proportional to the OD450 value. A standard curve is generated by assaying known concentrations of Human Adiponectin/Acrp30, and the concentration of Human Adiponectin/Acrp30 in unknown samples is interpolated from this curve based on their OD values.

Specifiche

Specifiche e purezza
BioReagent
Grado
BioReagent
Applicazione
ELISA
Tipo di campione
fluidi corporei, omogenati tissutali, Plasma, Siero, supernatanti di colture cellulari
Campo di rilevamento
0.78 ng/mL~50 ng/mL
Metodo di rilevamento
Sandwich ELISA
Specie rilevata Oggetto
Human
Specificità
Detecting Human Adiponectin/Acrp30 in samples, with no significant cross-reactivity to other homologs.
Detection instrument
Microplate reader
Detection wavelength
450nm
Stoccaggio e spedizione
Condizioni di conservazione di stoccaggio
Store at 2-8°C
Spedito in
Wet ice
Stabilità e conservazione
Store at 2-8℃ for 6 months.

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Domande frequenti e articoli
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Hai bisogno di aiuto per scegliere la qualità?

La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.

Visualizza la guida alle qualità BioReagent →

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.