Determine the necessary mass, volume, or concentration for preparing a solution.
Taxonomy Tree
| Kingdom | Inorganic compounds |
|---|---|
| Superclass | Homogeneous metal compounds |
| Classe | Homogeneous transition metal compounds |
| Subclass | Not available |
| Intermediate Tree Nodes | Not available |
| Direct Parent | Homogeneous transition metal compounds |
| Alternative Parents | Not available |
| Molecular Framework | Not available |
| Substituents | Homogeneous transition metal |
| Descrizione | This compound belongs to the class of inorganic compounds known as homogeneous transition metal compounds. These are inorganic compounds containing only metal atoms,with the largest atom being a transition metal atom. |
| External Descriptors | zinc group element atom |
| Sensibilità | Moisture sensitive. |
|---|---|
| Punto di ebollizione (°C) | 767°C |
| Punto di fusione (°C) | 321°C |
| Peso molecolare | 112.41 |
| XLogP3 | |
| Hydrogen Bond Donor Count | 0 |
| Hydrogen Bond Acceptor Count | 0 |
| Rotatable Bond Count | 0 |
| Exact Mass | 113.903 Da |
| Monoisotopic Mass | 113.903 Da |
| Topological Polar Surface Area | 0.000 Ų |
| Heavy Atom Count | 1 |
| Formal Charge | 0 |
| Complexity | 0.000 |
| Isotope Atom Count | 0 |
| Defined Atom Stereocenter Count | 0 |
| Undefined Atom Stereocenter Count | 0 |
| Defined Bond Stereocenter Count | 0 |
| Undefined Bond Stereocenter Count | 0 |
| The total count of all stereochemical bonds | 0 |
| Covalently-Bonded Unit Count | 1 |
H301:Toxic if swallowed
H330:Fatal if inhaled
H341:Suspected of causing genetic defects
H350:May cause cancer
H361:Suspected of damaging fertility or the unborn child
H372:Causes damage to organs through prolonged or repeated exposure
H410:Very toxic to aquatic life with long lasting effects
P201:Obtain special instructions before use.
P202:Do not handle until all safety precautions have been read and understood.
P260:Do not breathe dust/fume/gas/mist/vapors/spray.
P264:Wash hands [and …] thoroughly after handling.
P270:Do not eat, drink or smoke when using this product.
P271:Use only outdoors or in a well-ventilated area.
P273:Avoid release to the environment.
P280:Wear protective gloves/protective clothing/eye protection/face protection.
P284:[In case of inadequate ventilation] Wear respiratory protection.
P308:IF exposed or concerned:
P313:Get medical advice/attention.
P330:Rinse mouth.
P391:Collect spillage.
P301+P310:IF SWALLOWED: Immediately call a POISON CENTER/doctor/...
P304+P340:IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338:IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do - continue rinsing.
P308+P313:IF exposed or concerned: Get medical advice/attention.
P405:Store locked up.
P403+P233:Store in a well-ventilated place. Keep container tightly closed.
P501:Dispose of contents/container to an approved waste disposal plant.
The following are general, literature-based protocols for using a cadmium analytical standard; adapt to your method and consult the CoA for item-specific concentration and matrix.
Preparation of a working calibration set (example)
Matrix matching and QC
Spike recovery (sample validation)
Instrument setup notes
Item-specific instructions (e.g., density, uncertainty, expiry) are Not specified for this item; refer to CoA/Spec Sheet.
General biology of cadmium (literature)
Relevance to this product
Practical considerations (analytical biochemistry)
This product is not a buffering agent and is not typically used to prepare biological buffers.
Practical note
Item-specific buffer guidance
Cadmium is inherently hazardous and persistent; the most impactful “green” choices involve minimizing its use, preventing releases, and substituting analytes or methods in non-critical scenarios.
Reduction and substitution strategies (general)
Matrix/solvent considerations
Comparison (general, literature)
Trade-offs: Substitution may lower hazard but can compromise traceability or detection limits. If cadmium measurement is required by method/regulation, focus on micro-scale handling, secondary containment, and rigorous waste control.
Scope and limitations
Relevant use in pharmaceutical QA/QC (general)
Documentation and traceability
Item-specific pharmacopeial status
Item-specific properties
Cadmium (element) reference data (literature, not directly the solution)
Solution behavior (general guidance)
Note: Values labeled literature are typical for elemental cadmium and are provided for context only; they are not specifications of this solution.
Item-specific grade
What “analytical standard” generally implies (general)
Practical considerations
Appearance and stabilizers
As an analytical standard, this cadmium solution is primarily intended for calibration and quality control rather than for synthetic reactions.
Analytical applications (general)
Sample preparation workflows (general tips)
Off-label chemical reactivity
Because this is a calibration standard, “reaction conditions” translates to instrument method conditions for quantifying Cd. The following are literature-based general guidelines; they are not item-specific specifications.
AAS (flame/graphite furnace)
ICP-OES
ICP-MS
General preparation
Item-specific concentration, matrix, and density are Not specified for this item; refer to CoA/Spec Sheet.
Item-specific hazard data
General hazards for cadmium and cadmium solutions (literature/typical)
PPE and engineering controls (best practice)
Storage and incompatibilities (general)
First-aid overview (general)
Always consult the SDS for definitive, item-specific safety and first-aid guidance.
This product is a prepared cadmium standard solution; solvent selection usually pertains to diluents or matrix-matching rather than changing the product’s solvent.
Matrix and diluent considerations (general)
Miscibility and compatibility (general)
When to choose alternative matrices (general)
Storage (item-specific and general)
Stability and shelf life
Reconstitution and dilution
Handling practices
Waste
Research use only (per Product Data).
Brief description: This product is a cadmium standard solution (analytical standard). The exact solvent/matrix and concentration are not specified; consult the CoA/Spec Sheet for item-specific details.
Item-specific identifiers (from Product Data)
Composition notes (general/literature)
Structural features described in words (general)
Notes on speciation (general)
This product is intended as an analytical calibration solution and not as a synthetic reagent. Nevertheless, understanding cadmium’s chemical behavior can inform laboratory handling and compatibility.
Functional/coordination chemistry (general)
Historical synthetic chemistry (literature; not a use recommendation)
Practical implication for this product
Contamination control
Not applicable. This product is a chemical standard solution and not a biological affinity reagent (e.g., antibody, probe, or ligand). No antigen/epitope/clone/isotype information applies.
La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.