Enhanced Antifade Mounting Medium - Suitable for Immunofluorescence(IF), BioReagent, for fluorescence analysis

Cat. No.: A752105
Disponibile su ordine
QUALITÀ & PUREZZA Suitable for Immunofluorescence(IF) ? IF grade — validated for immunofluorescence with low background staining. Use to localize targets in cells/tissue by fluorescence microscopy. BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. for Fluorescence analysis ? Fluorescence-analysis grade — very low fluorescent impurities for clean spectra. Use in fluorescence assays where background interferes.
Storage
Store at 2-8°C
Shipped In
Wet ice
Application
IF/ICC
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
5ml
A752105-5ml
—
3 Disponibile
39,83€
10ml
A752105-10ml
Su ordinazione · 8–12 settimane
51,98€
Enter a quantity for the sizes you want to add.
🧪
Perché questa qualità

Suitable for Immunofluorescence(IF), BioReagent, for fluorescence analysis BioReagent,per l'analisi a fluorescenza,Suitable for Immunofluorescence(IF) per flussi di lavoro cromatografici e analitici sensibili che richiedono un'interferenza minima della linea di base.

🌡

Stoccaggio e spedizione

Store at 2-8°C Spedizione Wet ice. Consultare il COA specifico del lotto per le specifiche esatte.

📋

Documenti di qualità

SDS, COA, scheda tecnica e scheda delle specifiche disponibili per il download. COA specifico del lotto accessibile tramite ricerca per numero di lotto.

📚

Prova documentale

Citato in 0 pubblicazioni peer-reviewed su cromatografia, sintesi organica e reazioni di accoppiamento incrociato.

Panoramica

Enhanced Antifade Mounting Medium is a type of fluorescence decay-resistant mounting medium designed to slow down fluorescence quenching. It effectively suppresses quenching of all common fluorescent dyes and delivers far superior anti-quenching performance compared with standard antifade mounting media; its protective effect only slightly diminishes after 1 to 2 weeks. Calculated based on a usage volume of 50–100 μL per sample, a 5 mL bottle is sufficient for mounting at least 50 samples. This reagent is for research use only and shall not be applied for clinical diagnosis or other purposes.

Materials to Be Prepared Separately:

1. Glass slides

2. Coverslips

3. Fluorescence microscope

Operating Procedures (For Reference Only):

1. Adherent Cell Samples

(1) Aspirate staining solution after staining is completed.

(2) Drop one drop of Enhanced Antifade Mounting Medium onto the glass slide, then place the cell-attached coverslip over it to ensure full contact between cells and mounting medium, and minimize air bubbles.

(3) Observe under a fluorescence microscope, or store the slide at 4 °C protected from light for 1–2 weeks.

2. Tissue Sections

(1) Aspirate staining solution after staining is completed.

(2) Drop one drop of Enhanced Antifade Mounting Medium onto the tissue section, cover with a coverslip to ensure full contact between the section and mounting medium, and minimize air bubbles.

(3) Examine the tissue section under a fluorescence microscope, or store at 4 °C away from light for 1–2 weeks.

3. Other Specimens

Handle other specimens following the protocols for cell samples or tissue sections accordingly.

Precautions:

1. Anti-quenching performance is relative. Samples should ideally be observed immediately after staining; if immediate observation is unavailable, examine them on the same day.

2. Fluorescent substances are susceptible to quenching. All stained samples should be stored at 4 °C protected from light.

3. Although this medium slows fluorescence quenching, samples still require strict light avoidance after mounting.

4. Do not use this mounting medium for slides stained with rhodamine-conjugated antibodies; polyvinyl alcohol-based fluorescent mounting medium is recommended as an alternative.

5. Wear a lab coat and disposable gloves throughout all operations for personal safety and health protection.

6. Use up the reagent promptly once opened to avoid compromised experimental results.

Specifiche

Specifiche e purezza
Suitable for Immunofluorescence(IF), BioReagent, for fluorescence analysis
Stabilità e conservazione
Store at 2-8℃ long term (12 months).
Condizioni di conservazione di stoccaggio
Store at 2-8°C
Spedito in
Wet ice
Questo prodotto richiede spedizione a catena fredda. I servizi di terra e altri servizi economici non sono disponibili.
Grado
BioReagent, per l'analisi a fluorescenza, Suitable for Immunofluorescence(IF)
Product Line
Prodotti biologici

Documentazione

📋 Scheda di dati di sicurezza (SDS)

Documento completo su pericoli, manipolazione, stoccaggio e conformità normativa.

<<<<<<< HEAD Scarica SDS → ======= Scarica SDS → >>>>>>> release248-p3

✅ Certificato di analisi (COA)

Dati di qualità specifici del lotto. Inserisci il numero di lotto per recuperare il COA esatto.

Cerca COA →

📊 Scheda tecnica

Riepilogo di riferimento rapido delle specifiche e applicazioni del prodotto.

Visualizza scheda tecnica →

🔬 Scheda delle specifiche

Attributi di qualità completi e criteri di accettazione per questa qualità.

Visualizza scheda delle specifiche →

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

3 results found

Lot NumberCertificate TypeDataOggetto
ZJ26F0738073ZJ26F0738073Certificate of AnalysisAug 05, 2026 A752105
ZJ25F0623338ZJ25F0623338Certificate of AnalysisApr 07, 2026 A752105
ZJ26F0333011ZJ26F0333011Certificate of AnalysisMar 13, 2026 A752105
Domande frequenti e articoli
Suitable for Immunofluorescence(IF)
Choosing Reagents ‘for Fluorescence Analysis’: A Practical Guide
Protein Carbonyl Detection
DRAQ5 and DRAQ7 Nuclear Dye Experimental Operating Procedure
Standard Operating Procedure for SYTO 9 and PI Combined Live/Dead Staining
Comparative Analysis and Selection Strategies for Mounting Media in Immunological Experiments
Cell Apoptosis Detection by TUNEL Labeling: Signal Interpretation and Result Evaluation
Principles, Classification, and Clinical Laboratory Applications of Hematologic Cytochemical Staining
Main Methods and Experimental Selection for Microfilament Staining
Selection of Fixation, Clearing, Deparaffinization, Staining, and Mounting Systems in Histological Sample Preparation
Cellular Structural Fluorescence Staining and Multichannel Imaging
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.