Fischor Mounting Medium - BioReagent,for microscopy,Suitable for Immunofluorescence(IF),Suitable for Immunohistochemistry(IHC)

Cat. No.: F1508973
Disponibile su ordine
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. for Microscopy ? Microscopy grade — reagents/stains suited to sample prep and imaging. Use in microscopy where clarity and low background are needed. Suitable for Immunohistochemistry(IHC) ? IHC grade — validated for immunohistochemistry on tissue sections. Use to detect and localize antigens in fixed tissue. Suitable for Immunofluorescence(IF) ? IF grade — validated for immunofluorescence with low background staining. Use to localize targets in cells/tissue by fluorescence microscopy.
Storage
Store at 2-8°C
Shipped In
Wet ice
Application
Cell Staining, IF/ICC, IHC
★
Size
Germania (EU)
USA*
Price
Qty
10ml
F1508973-10ml
Su ordinazione · 8–12 settimane
25,95€
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent,for microscopy,Suitable for Immunofluorescence(IF),Suitable for Immunohistochemistry(IHC) BioReagent,per la microscopia,Suitable for Immunofluorescence(IF),Suitable for Immunohistochemistry(IHC) for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Panoramica

Product Introduction

A section is sandwiched between a slide and a coverslip, with a mounting medium applied in between to seal it off from contact with the outside air. This process is called mounting. On the one hand, it preserves the stained slides; on the other hand, the mounting medium with a suitable refractive index allows the tissue cells in the sample to be clearly visualized.

Fischor Mounting Medium is mainly composed of glycerol, gelatin, and a small amount of phenol. It can be used for mounting various routine sections and smears. This reagent is intended for research purposes only and not for clinical diagnosis or other applications.

Materials to Be Prepared by Users

Tissue samples, slides, coverslips, microscope

Operating Procedures (For Reference Only)

1. Cell Samples

① After staining, aspirate all liquid completely.

② Add 1-2 drops of Fischor Mounting Medium onto the slide, then place the coverslip with adherent cells onto the medium, ensuring the cells come into contact with the mounting medium and minimizing bubble formation.

③ Observe under a microscope.

2. Tissue Sections

① After staining, aspirate the staining solution.

② Add 1-2 drops of Fischor Mounting Medium onto the tissue section, then place a coverslip over it, ensuring the section is in contact with the mounting medium and minimizing bubble formation.

③ Observe the tissue section under a microscope.

3. Other Samples

Follow the procedures for cell samples or tissue sections.

Precautions

1. Mounted samples should be stored away from light.

2. The mounting medium appears solid at low temperatures. Before use, incubate it in a water bath at 37-50 °C until it is completely dissolved.

3. For your safety and health, wear a lab coat and disposable gloves during operation.

4. Please use the reagent as soon as possible after opening to avoid affecting subsequent experimental results.

Specifications

Specifiche e purezza
BioReagent,for microscopy,Suitable for Immunofluorescence(IF),Suitable for Immunohistochemistry(IHC)
Condizioni di conservazione di stoccaggio
Store at 2-8°C
Spedito in
Wet ice
Questo prodotto richiede spedizione a catena fredda. I servizi di terra e altri servizi economici non sono disponibili.
Grado
BioReagent, per la microscopia, Suitable for Immunofluorescence(IF), Suitable for Immunohistochemistry(IHC)

Documentazione

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDataOggetto
ZJ26F0232105Certificate of AnalysisFeb 10, 2026 F1508973
Domande frequenti e articoli
Comparative Analysis and Selection Strategies for Mounting Media in Immunological Experiments
Cell Apoptosis Detection by TUNEL Labeling: Signal Interpretation and Result Evaluation
Cell Apoptosis Detection by TUNEL Labeling: Signal Interpretation and Result Evaluation
Principles, Classification, and Clinical Laboratory Applications of Hematologic Cytochemical Staining
Main Methods and Experimental Selection for Microfilament Staining
Operating Procedure for p16/Ki-67 Immunocytochemical Dual Staining in Cervical Cytology
Selection of Special Staining Methods and Their Applications in Pathological Diagnosis: Fibers, Carbohydrates, Lipids, Pigments, and Pathogen Staining
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Domande frequenti

What does Suitable for Immunofluorescence(IF) mean?
Suitable for Immunofluorescence(IF) indicates the product has been validated for use in immunoassays such as ELISA, IF, IHC and flow cytometry. Validation may include positive/negative control samples, signal-to-noise testing, and protocol-specific QC. Lot-specific test data is published on the Certificate of Analysis where available.
What does BioReagent mean?
BioReagent indicates that the product has been processed and tested for biological and biochemical applications. Specifications may include endotoxin limits, microbial controls, sterility, low DNase/RNase/protease activity, and verified biological activity where relevant.
How should this product be stored?
Store at 2–8 °C. Refrigerated storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.