GA₃ Stock Solution (1 mg/mL) - BioReagent

Cat. No.: G1528802
Disponibile su ordine
QUALITÀ & PUREZZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
Storage
Store at 2-8°C
Shipped In
Wet ice
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
100ml
G1528802-100ml
Su ordinazione · 8–12 settimane
25,95€
Enter a quantity for the sizes you want to add.

Panoramica

This product is a stock solution of gibberellin A₃ (GA₃), formulated with GA₃ and ethanol. It is intended for use as a plant growth regulator in plant tissue culture, seed germination, stem elongation, and flowering regulation research. For research use only. Not for clinical diagnosis or other applications.

Specifiche

Specifiche e purezza
BioReagent
Condizioni di conservazione di stoccaggio
Store at 2-8°C
Spedito in
Wet ice
Questo prodotto richiede spedizione a catena fredda. I servizi di terra e altri servizi economici non sono disponibili.
Grado
BioReagent
Product Line
Prodotti biologici

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Application Protocols

The following are example research workflows for GA₃ stock solutions. They are provided as general literature-based guidance and should be optimized per species/tissue. Item-specific solvent and exact concentration verification should be taken from the CoA.

  1. Preparing a working solution • Confirm the stock solvent on the CoA. • Determine required final co-solvent percentage compatible with your assay (e.g., ≤0.1–0.5% v/v DMSO or ethanol). • Calculate dilution: If using the literature MW for GA₃ (~346.37 g/mol), a 1 mg/mL stock ≈2.88 mM. To make 10 µM in media, add 3.47 µL stock per 1 L per µM-equivalent; practically, 3.5 mL of stock into 1 L yields ~10 µM. Adjust using the verified MW from CoA. • Mix thoroughly; protect from light.

  2. Seed germination assay (example) • Prepare agar plates or liquid media (e.g., ½ MS) with 0.1–10 µM GA₃; include vehicle controls. • Stratify seeds as required, then sow and incubate under defined light/temperature regimes. • Score germination and early growth at set intervals (e.g., 24–96 h).

  3. Stem elongation assay (cuttings or seedlings) • Treat with a range (e.g., 0.1–100 µM) via foliar spray or root drench; maintain consistent co-solvent. • Measure internode length and biomass over time; record environmental parameters.

  4. Tissue culture supplementation • Add sterile-filtered GA₃ to cooled, sterile media to 0.1–5 µM depending on species/protocol.

Always include negative (vehicle) and, if relevant, positive controls; document lot and conditions for reproducibility.

Biological Roles

GA₃ (gibberellic acid) is a canonical member of the gibberellin family of diterpenoid phytohormones that regulate numerous aspects of plant growth and development (literature/general knowledge).

Key roles and pathways (literature): • Germination and seedling establishment: GA promotes endosperm weakening and mobilization of seed reserves (e.g., induction of hydrolytic enzymes), facilitating radicle emergence. • Cell elongation and organ growth: GA stimulates stem and internode elongation, leaf expansion, and certain aspects of floral development. Phenotypic effects are strongly genotype- and context-dependent. • Signaling mechanism: Bioactive GA binds to the soluble receptor GID1, enabling recruitment of DELLA repressors to SCF E3 ubiquitin ligase complexes, targeting DELLAs for proteasomal degradation. Relief of DELLA-mediated repression activates GA-responsive transcriptional programs. • Crosstalk: Extensive interactions with auxin, cytokinin, abscisic acid, brassinosteroids, and light signaling pathways adjust growth to environmental inputs. • Biosynthesis/turnover: Derived from geranylgeranyl pyrophosphate via ent-kaurene intermediates, with multiple oxidation steps; levels are tightly controlled by biosynthetic/deactivation enzymes and transport (species- and tissue-specific).

Usage implications for researchers: • Dose–response is often biphasic and tissue-specific; high doses can be inhibitory. • Developmental stage and environmental cues (light, temperature, water status) modulate GA sensitivity. • Experimental design should incorporate time-course sampling and appropriate vehicle controls to attribute responses specifically to GA signaling perturbation.

Note: The above summarizes biological roles for research context only and does not imply agricultural or clinical claims.

Buffer Applications

GA₃ itself is not a buffering agent. However, it is commonly delivered into buffered aqueous media for plant biology assays.

Practical guidance (general/literature): • Working media: Common plant media (e.g., MS or ½ MS) buffered near neutral pH (≈5.7–6.0 for agar media; ≈5.8–6.2 for hydroponic/culture solutions) are typical vehicles. Adjustments depend on species and culture system. • Preparation: If your stock solvent is organic (e.g., ethanol or DMSO), pre-dilute into a small aliquot of buffer or media with vigorous mixing, then add to the bulk to achieve the target final concentration while keeping co-solvent ≤0.1–1% v/v. • pH considerations: GA₃ is a weak acid; extreme pH can promote decomposition (e.g., lactone hydrolysis under strong base). Maintain near-neutral pH for stability during use (literature). • Sterility: For tissue culture, add GA₃ stocks aseptically post-autoclave when media cools to ≈50–60°C, or sterile-filter the hormone solution (0.2 µm) into sterile media. • Adsorption: Minimize prolonged contact with highly hydrophobic plastics; use glass or low-binding plastics when working at very low nanomolar concentrations to reduce loss.

Item-specific buffer details (pH, ionic strength, excipients) are Not specified for this item; refer to CoA/Spec Sheet if the supplied solvent or any buffer components are declared.

Green Alternatives

Because this is a hormone stock solution rather than a process solvent, green chemistry considerations primarily concern the choice of diluent/co-solvent for working solutions and the minimization of hazardous components.

General guidance (literature/practice): • Prefer aqueous media whenever feasible; dissolve GA₃ in minimal green co-solvent (e.g., ethanol) before dilution. • Avoid large fractions of high-toxicity solvents in biological assays; keep DMSO low if used. • Prepare only the amount needed to limit waste; dispose according to local regulations.

Illustrative comparison of common vehicles (not item-specific):

  • Water (buffered) • Pros: Safest, greenest; compatible with plant systems; no VOCs. • Cons: Limited solubility of GA₃ unless adjusted or pre-dissolved.

  • Ethanol • Pros: Bio-based/renewable routes available; readily biodegradable; mixes well with media; easy evaporation. • Cons: VOC; flammable; biological effects at higher %.

  • DMSO • Pros: Excellent solvency; low vapor pressure; minimal odor. • Cons: Can alter membrane permeability; potential biological effects; less green sourcing.

Operational tips: • Use the minimal effective co-solvent percentage. • Store concentrated stocks to reduce shipping volume and waste; this item is already provided at 1 mg/mL—verify if further concentration is permissible based on solvent (CoA). • Employ amber containers or foil wrap to reduce photodegradation, extending utility and reducing discards.

Pharmaceutical Uses

This product is supplied for research use only. It is not intended for human or veterinary use, diagnostic procedures, or clinical applications.

Contextual notes (general): • GA₃ is a plant phytohormone used in research and certain agricultural technologies; it does not have common roles as a human pharmaceutical active ingredient or excipient. • No pharmacopeial monograph or excipient status is implied by this BioReagent-grade listing.

For any formulation-style laboratory work (e.g., preparing defined vehicles for plant delivery): • Document the solvent system and target concentration. • Include appropriate vehicle controls when translating between ethanol-, DMSO-, or water-based carriers.

Item-specific regulatory or pharmacopeial status: Not specified for this item; refer to CoA/Spec Sheet.

Physical Properties

Item-specific physical data for this stock solution are not provided; consult the CoA/Spec Sheet.

• Concentration (as supplied): 1 mg/mL (solvent not specified for this item). • Appearance: Not specified for this item; refer to CoA/Spec Sheet. • Density, refractive index (solution): Not specified for this item; refer to CoA/Spec Sheet. • pH (if aqueous): Not specified for this item; refer to CoA/Spec Sheet. • Freezing point/boiling point of the solution: Not specified for this item; refer to CoA/Spec Sheet.

Literature/general reference values for GA₃ (solid): • Typical solubility: Sparingly soluble in pure water; soluble in ethanol, methanol, acetone; soluble in DMSO (literature). Actual solubility of this stock depends on its solvent (not specified for this item). • Acid–base: Weak organic acid; reported pKa values for carboxyl functionality are in the acidic range (literature, method-dependent). Exact numeric values are not item specifications.

Practical notes (general): • If the solvent is aqueous, GA₃ solutions may be more stable near neutral pH and when protected from light; hydrolysis of the lactone can occur under strong alkaline conditions (literature). • If the solvent is an alcohol or DMSO, the solution will mix readily with most aqueous plant media; gradual dilution into buffered media helps avoid local supersaturation. • Always verify solvent identity and any stabilizers in the item’s CoA before planning dilutions or sterile filtration.

Quality and Grades

• Grade: BioReagent (item-specific).

  • BioReagent grade indicates suitability for common biological and biochemical laboratory applications, including cell/plant culture research workflows, where general purity and low bioburden are important. It does not imply clinical/diagnostic use.

• What BioReagent means in practice:

  • Sourcing and handling emphasize consistency and low typical levels of adventitious contaminants that might interfere with bioassays.
  • UV-Vis absorbance, trace metals, endotoxin/bioburden, and solvent identity may be controlled, but the specific acceptance criteria for this item are Not specified for this item; refer to CoA/Spec Sheet.

• Stabilizers/preservatives: Not specified for this item; refer to CoA/Spec Sheet.

• Filtration/sterility:

  • If aseptic plant culture or tissue culture use is intended, verify whether the stock is sterile-filtered (0.2 µm) from the CoA. If sterility is not specified, users may opt to sterile-filter the working solution immediately before use under aseptic conditions.

• Lot-to-lot control:

  • For quantitative phenotyping or hormone-response assays, use a single lot across an experiment set when possible. Record lot number, concentration, and solvent for reproducibility.

• Documentation: Request the Certificate of Analysis for lot-specific parameters (concentration verification, solvent identity, pH if aqueous, and any limits relevant to your workflow).

Reaction and Applications

This product is not typically used as a chemical reagent in synthetic transformations. Instead, GA₃ is employed as a biological modulator in plant science research.

Research application themes (biological, literature): • Seed germination and dormancy studies: GA₃ is used to probe germination control and to synchronize germination in some species. • Plant growth and development: Assays of stem elongation, leaf expansion, flowering, and fruit set, often in conjunction with auxin, cytokinin, or ABA treatments. • Tissue culture: Inclusion in micropropagation media to modulate shoot elongation and morphogenesis. • Signal transduction: Perturbation studies of the GID1–DELLA pathway to analyze GA-responsive gene expression and proteasome-mediated DELLA degradation.

Practical notes (general): • Calibrate dose–response: GA₃ responses are highly species- and tissue-dependent; perform preliminary titrations. • Solvent controls: Include vehicle-only controls at identical co-solvent percentages. • Stability: Protect working solutions from light; prepare fresh as needed to minimize degradation. Avoid prolonged high pH.

If your objective is organic synthesis or derivatization of gibberellins, consult specialized literature; this stock solution is formulated for biological research workflows rather than preparative chemistry.

Reaction Conditions

Not typically applicable: GA₃ stock solutions are used for biological dosing rather than chemical reactions.

For analytical/bioassay workflows (general guidance): • Working concentration ranges: Literature reports span from low nanomolar to tens of micromolar depending on species, tissue, and endpoint (e.g., 10 nM–100 µM). Always conduct a pilot titration for your system. • Vehicle fraction: Keep ethanol or DMSO at minimal levels compatible with your assay (commonly ≤0.1–1% v/v), with appropriate vehicle controls. • Temperature and light: Prepare and store working solutions at room temperature to 4°C as appropriate for the assay; protect from light to reduce photodegradation. • Filtration: For sterile applications, filter through 0.2 µm membranes using low-binding materials.

Stoichiometry conversions (literature-based, not item specification): • If one assumes GA₃ MW ~346.37 g/mol (literature), a 1 mg/mL stock corresponds to ~2.88 mM. This facilitates rapid calculation of micromolar working dilutions. Verify MW on the CoA for precise calculations.

Safety and Handling

Item-specific hazard classification (GHS), pictograms, and H/P statements: Not specified for this item; refer to the product SDS for authoritative safety information.

General laboratory safety for GA₃ stock solutions (literature/practice): • PPE: Wear lab coat, safety glasses, and appropriate chemical-resistant gloves. Use in a well-ventilated area or biological safety cabinet when preparing sterile solutions for plant culture. • Avoid ingestion, inhalation of aerosols/mists, and skin/eye contact. Wash thoroughly after handling. • Storage incompatibilities: Avoid strong bases (which can hydrolyze lactones) and strong oxidizers. Keep containers tightly closed to minimize evaporation/contamination. Protect from prolonged light exposure to minimize potential photodegradation (literature). • Spill/cleanup: Absorb small spills with inert material, clean with water/ethanol as appropriate for the solvent system, and dispose according to institutional and local regulations. • First aid (overview; defer to SDS):

  • Skin/eye contact: Rinse with water for several minutes; remove contaminated clothing; seek medical attention if irritation persists.
  • Inhalation: Move to fresh air; seek medical attention if symptoms occur.
  • Ingestion: Rinse mouth; do not induce vomiting; seek medical advice. • Waste: Collect unused solutions and contaminated disposables as chemical waste. Do not discharge to drains unless permitted by local regulations. • Transport/temperature: This item is shipped on wet ice and should be stored at 2–8°C as specified for this item.
Solvent Selection

This product is a ready-to-use GA₃ stock at 1 mg/mL. The supplied solvent is Not specified for this item; refer to CoA/Spec Sheet.

General solvent considerations for GA₃ (literature/practice): • Polarity/solubility profile: GA₃ is a weak organic acid with moderate polarity; it is soluble in polar organic solvents (ethanol, methanol, acetone, DMSO) and only sparingly soluble in pure water unless adjusted (e.g., slight basification) or aided by co-solvent. • Miscibility: Ethanol and DMSO stocks are miscible with aqueous plant media; add slowly with mixing to prevent local precipitation. Typical final co-solvent fractions kept ≤0.1–1% v/v to avoid biological confounders (literature guidance). • pH effects: In aqueous systems, solubility increases with pH as the carboxylate forms; however, elevated pH can risk lactone hydrolysis over time (literature). Prefer neutral buffers and prepare fresh dilutions.

Comparison (general guidance; not item-specific): • Water: Greenest option; may require gentle pH adjustment or warming/sonication to fully dissolve GA₃; best for media requiring minimal organic content. • Ethanol (EtOH): Common, relatively green organic co-solvent; rapidly mixes with media; volatile and easy to remove; keep final EtOH low to avoid biological effects. • DMSO: Excellent solvency; minimal volatility; ensure final DMSO ≤0.1–0.5% v/v in most plant assays.

Tip: Match the working dilution solvent system to your assay tolerance for co-solvents. Always confirm the supplied solvent for this item on the CoA before planning additions.

Storage and Reconstitution

• Storage temperature (item-specific): Store at 2–8°C. • Shipping (item-specific): Shipped on wet ice. • Container: Keep tightly closed to minimize evaporation/contamination; use compatible caps/septa based on the supplied solvent (verify on CoA). • Light protection: GA₃ is light-sensitive to varying degrees (literature). Store in amber vials or protect from light to maximize stability. • Reconstitution: Not applicable—this is a ready-to-use 1 mg/mL stock solution. If concentration adjustment is required, use an appropriate sterile solvent consistent with your application and the original solvent system (verify on CoA). • Aliquoting: To minimize repeated warming and potential contamination, subdivide into single-use aliquots upon receipt under aseptic conditions if sterile work is intended. • Freeze–thaw: Avoid unnecessary freeze–thaw cycling. Unless the CoA specifies frozen storage compatibility, maintain at 2–8°C and prepare fresh working solutions as needed. • Stability/shelf life: Not specified for this item; refer to CoA/Spec Sheet. As general practice, discard if precipitation, turbidity, or discoloration develops, or if past the labeled expiry. • Handling before use: Allow to equilibrate to room temperature if condensation is a concern; vortex briefly to ensure homogeneity. Verify concentration and solvent on the CoA prior to critical experiments. • Research use only: As labeled for this item.

Structure and Identity

• Product type: Ready-to-use stock solution of GA₃ (gibberellic acid) at 1 mg/mL. • Item-specific identifiers (CAS, CID, InChIKey, SMILES): Not specified for this item; refer to CoA/Spec Sheet. • Concentration: 1 mg/mL (as supplied; solvent not specified for this item). • Structural class (literature): GA₃ is a diterpenoid phytohormone belonging to the gibberellin family, built on an ent-gibberellane tetracyclic framework containing a lactone ring and a carboxylic acid functionality. • Functional groups (literature): Carboxylic acid, lactone (cyclic ester), multiple tertiary/secondary alcohol stereocenters within a fused polycyclic backbone. • Stereochemistry (literature): Multiple defined stereocenters characteristic of naturally occurring gibberellins; GA₃ is a single, well-defined stereoisomer produced by fungi/plants. • 2D structural description (literature): A compact, polycyclic carbon framework with one five-membered lactone fused to a tricyclic hydrocarbon system; a pendant carboxyl group and hydroxyl substituents confer acidity and moderate polarity. • Molecular formula and molecular weight: Not specified for this item; refer to CoA/Spec Sheet. (Note: GA₃ is commonly described in literature as C19H22O6, MW ~346.37 g/mol; provided here as literature context only, not as item specification.)

Synthetic Utility

GA₃ stock solution is not typically employed as a reagent or building block in synthetic organic chemistry. Its primary value is as a biologically active small molecule for plant research.

General chemistry perspective (literature): • Functional groups: One carboxylic acid and a lactone within a complex, polycyclic diterpenoid backbone. These groups, while reactive in principle (e.g., esterification, amidation, hydrolysis), are usually not targeted in routine lab syntheses when using GA₃ as a hormone standard. • Reactivity considerations: Strong bases can open the lactone; nucleophiles may acylate or hydrolyze sensitive centers. These transformations are primarily of academic interest in gibberellin chemistry rather than common lab practice. • Analytical standards: In analytical chemistry, GA₃ may serve as a standard for method development/validation (e.g., LC–MS quantitation of phytohormones). For such use, solvent identity, concentration accuracy, and stability are critical; verify with the item’s CoA.

If your objective is to derivatize GA₃ (e.g., for probe synthesis), begin from neat GA₃ and consult specialized gibberellin literature; this diluted stock is formulated for biological dosing and analytical spiking, not for preparative transformations.

Target Specificity

Not applicable. This product is not an antibody or affinity reagent and has no clone/isotype attributes. GA₃ acts systemically in plants by engaging the GA receptor GID1 and triggering DELLA repressor degradation (biological mechanism; literature), but no item-specific target-binding parameters are provided.

Hai bisogno di aiuto per scegliere la qualità?

La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.

Visualizza la guida alle qualità BioReagent →

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.