Hemoglobin Content Assay Kit (Hematin, Colorimetric Method)

Cat. No.: H1522002
Disponibile su ordine
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Size
Germania (EU)
USA*
Price
Qty
100T
H1522002-100T
Su ordinazione · 8–12 settimane
104,04€
Enter a quantity for the sizes you want to add.
🧪
Why this grade

BioReagent BioReagent for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C,Protected from light Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Panoramica

Hemoglobin (Hb or HGB) is a protein responsible for transporting oxygen in higher organisms and is the protein that gives blood its red color. Hemoglobin is composed of four chains: two α chains and two β chains, each containing a heme group with an iron atom. Hemoglobin readily binds to oxygen in areas with high oxygen concentration and easily dissociates from it in areas with low oxygen concentration. This property of hemoglobin enables red blood cells to transport oxygen. Currently, the primary methods for hemoglobin detection include the cyanmethemoglobin oxidation method, alkaline hematin determination, sodium lauryl sulfate binding method, and copper sulfate titration method. Alternatively, imported large-scale biochemical analyzers are used for measurement. The cyanmethemoglobin oxidation method involves the toxicity and hazardous waste issues associated with potassium cyanide. The copper sulfate titration method is prone to preparation errors and is easily affected by environmental temperature. Biochemical analyzers, on the other hand, are expensive and have high testing costs. The detection principle of this kit is based on the oxidation of ferrous ions (Fe²⁺) in hemoglobin to ferric ions (Fe³⁺) by potassium ferricyanide, converting hemoglobin into methemoglobin. Methemoglobin then reacts with azide salt to form stable azide methemoglobin, which has a broad absorption peak at 540–546 nm. The absorbance is directly proportional to the hemoglobin concentration. This product is used to measure hemoglobin content in blood, aiding in the diagnosis of conditions such as anemia and blood loss. This product is intended for research purposes only and is not suitable for clinical diagnosis or other uses.

Specifications

Specifiche e purezza
BioReagent
Grado
BioReagent
Applicazione
Cell Metabolism
Metodo di rilevamento
Colorimetric Method
Detection instrument
Visible Spectrophotometer
Detection wavelength
540nm
Stoccaggio e spedizione
Condizioni di conservazione di stoccaggio
Store at 2-8°C,Protected from light
Spedito in
Wet ice
Stabilità e conservazione
Store at 2-8℃ for 6 months. Store in the dark.

Documentazione

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Domande frequenti e articoli
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Application Protocols
  • Item-specific, validated protocols: Not specified for this item; follow the kit insert for definitive instructions.

  • General workflow for hematin colorimetric hemoglobin quantitation (literature/general):

    1. Equilibrate reagents to room temperature and protect from strong light.
    2. Prepare a hemoglobin standard curve (e.g., serial dilutions of a reference hemoglobin) in assay buffer. Include a reagent blank.
    3. Sample preparation: For whole blood, prepare an appropriate dilution in assay buffer and, if required, lyse erythrocytes under conditions compatible with the hematin chemistry. Clarify turbid samples by brief centrifugation.
    4. Reaction setup: Dispense specified volumes of reagent and standards/samples into cuvettes or microplate wells as directed by the method. Mix gently to avoid bubbles.
    5. Incubation: Allow color to develop to completion at room temperature for the time recommended by the method.
    6. Measurement: Read absorbance at the specified wavelength for the hematin chromophore using a spectrophotometer or microplate reader. Use pathlength correction when applicable.
    7. Calculations: Subtract blank, fit the standard curve, and calculate sample concentrations, applying dilution factors.
    8. QC: Include duplicates or triplicates and quality controls; assess precision (CV) and linearity.
  • Notes:

    • Validate potential interferences (bilirubin, lipids, detergents) for your sample type.
    • Maintain consistent timing and temperature across standards and samples.
Biological Roles
  • Hemoglobin overview (general biology):

    • Hemoglobin is a tetrameric heme protein responsible for oxygen transport in vertebrate erythrocytes. Each subunit contains a protoporphyrin IX (heme) coordinated to Fe that binds O2 cooperatively.
    • The heme prosthetic group underlies the strong visible absorbance exploited in colorimetric assays. Oxidation state and ligand environment modulate spectral features, which is why assays convert hemoglobin to a defined hematin species before measurement (literature).
  • Relevance to research workflows:

    • Hemoglobin content serves as a normalization metric for erythroid cell cultures and tissue samples.
    • Studies of oxidative stress, hemolysis, erythropoiesis, or storage lesions in blood products routinely quantify total hemoglobin.
    • Cross-reactivity with other heme proteins (e.g., myoglobin, cytochromes) is typically low when using hemoglobin-specific conversion/conditions, but verification with controls is prudent (literature general guidance).
  • Metabolic and structural notes (general):

    • The globin chains arise from HBA/HBB genes in humans; variants and post-translational modifications can affect stability and heme binding.
    • Free heme/hemin can catalyze oxidative reactions; assay conditions that sequester or convert heme help produce consistent optical signals for quantification.
  • This item:

    • The kit quantifies total hemoglobin regardless of isoform; exact specificity parameters are not specified for this item and should be confirmed with the kit insert.
Buffer Applications

This product is an assay kit rather than a general-purpose buffering system.

  • Applicability:

    • The included buffers (if provided) are intended solely to support hemoglobin-to-hematin conversion and stable color development. They are not optimized for generic buffering or cell culture.
  • Practical advice (general):

    • If permitted by the protocol, prepare fresh working buffers with high-purity water to minimize background.
    • Maintain ionic strength and pH identical between standards and samples to limit matrix effects.
  • Item-specific buffer compositions, pH, and preparation instructions: Not specified for this item; refer to the kit insert.

Green Alternatives
  • Context:

    • Hemoglobin quantification has historically used cyanmethemoglobin (Drabkin’s) methods that employ cyanide salts. Hematin-based colorimetric approaches can be cyanide-free and therefore reduce acute toxicity and hazardous waste concerns (literature). This product’s title specifies “Hematin, Colorimetric Method,” which typically indicates a cyanide-free workflow; confirm in the kit insert.
  • Comparison (literature/general):

    • Cyanmethemoglobin (Drabkin’s):
      • Advantages: Widely standardized; stable chromophore with a defined absorbance maximum (around 540–546 nm, literature).
      • Disadvantages: Cyanide toxicity; stricter waste management; regulatory constraints.
    • Hematin-based methods:
      • Advantages: Avoid cyanide; rapid color formation; suitable for routine spectrophotometry.
      • Trade-offs: Potentially different spectral maxima and matrix interferences; method-specific calibration is required.
  • Practical greener choices:

    • Prefer cyanide-free hematin/alkaline-hematin chemistries when permissible for your application.
    • Minimize reagent volumes and adopt microplate formats to reduce waste.
    • Use compatible, non-chlorinated cleaners and validated decontamination protocols for biological residues.
  • Note for this item:

    • Exact reagent composition and any hazard-reducing substitutions are not specified for this item; consult the SDS/insert for confirmation.
Pharmaceutical Uses
  • Not a pharmaceutical or excipient product.
  • Intended use is research-only analytical quantification of hemoglobin in laboratory samples. No pharmacopeial monograph or formulation role is claimed or implied for this kit.
  • For manufacturing QC or regulated testing, method validation against applicable guidelines (e.g., linearity, precision, accuracy, robustness) would be required, but such validation parameters are not specified for this item.
Physical Properties
  • Item-specific physical properties (for the kit and its reagents): Not specified for this item; refer to CoA/Spec Sheet and SDS for each component.

  • Typical assay readout (literature/general):

    • Detection mode: Colorimetric (visible).
    • Common measurement wavelength bands for hematin/hematin-like colorimetric hemoglobin assays: approximately 560–600 nm or near a defined visible maximum depending on the reagent system (literature). Exact wavelength for this kit is not specified; follow the kit insert.
    • Typical linear working ranges reported in hematin-based hemoglobin methods: on the order of low mg/dL to g/dL when appropriate dilutions are used (literature). Item-specific range is not specified here.
  • Solubility context (general):

    • Assay reagents are typically supplied as aqueous buffers/solutions or lyophilized solids that reconstitute in water or proprietary buffer; exact compositions are not specified for this item.
  • Other parameters (bp, mp, density, logP, pKa, nD): Not applicable to the kit format or not specified for this item; refer to component CoA/SDS if required.

Quality and Grades
  • Item-specific: BioReagent grade (from Product Data).

  • What BioReagent grade implies (general):

    • Intended for research and laboratory use with consistent performance for biochemical/analytical workflows.
    • Emphasis on lot-to-lot reproducibility, low background in colorimetric detection, and suitability for routine quantitation in research samples.
  • Kit quality considerations (general guidance):

    • Standard curve fidelity: High-quality standards/calibrators (if supplied) and stable chromogenic reagents are critical to accuracy. Verify recovery with in-matrix controls.
    • Light protection: Chromophores and porphyrinoid species can photobleach; amber or foil-wrapped containers are typically used. This item indicates “protected from light,” underscoring light sensitivity.
    • Documentation: Certificate of Analysis (CoA) typically provides acceptance criteria (e.g., blank absorbance limit, standard curve R²). Item-specific criteria are not specified here.
  • What is not specified for this item:

    • Stabilizers, preservatives, and exact composition of reagents; performance specifications (LOD/LOQ, linearity range, precision, and interferences). Refer to the kit insert and CoA/Spec Sheet for lot-specific details.
  • Research use only:

    • As indicated, the product is for research use only and not for diagnostic or clinical procedures.
Reaction and Applications
  • Intended application (from Product Data): Quantitative determination of hemoglobin content using a hematin colorimetric method. For research use only.

  • Typical research use-cases (general):

    • Total hemoglobin quantification in erythrocyte lysates to normalize cellular assays to heme content.
    • Estimating hemoglobin content in tissue homogenates (e.g., spleen, bone marrow, muscle with myoglobin cross-considerations) while validating specificity to hemoglobin vs other heme proteins.
    • Monitoring hemoglobin release in hemolysis studies, oxidative stress models, or red cell storage research.
    • Quality control of purified hemoglobin preparations and reconstitution experiments (e.g., hemoglobin-based materials research).
  • Practical considerations (literature/general):

    • Hematin-based color development is typically rapid at ambient temperature; precise incubation time and wavelength depend on formulation (follow kit insert).
    • Strong sample chromophores (bilirubin, hemolysate turbidity, lipemia) may affect absorbance; perform background correction using matrix-matched blanks or dual-wavelength reading if recommended by the method.
    • Detergents and chelators can alter heme speciation; keep sample buffer composition consistent with standards.
    • For whole blood, controlled dilution (e.g., in the assay buffer) minimizes inner-filter effects and non-linearity at high Hb levels (literature).
  • Data handling (general):

    • Construct a standard curve with known hemoglobin concentrations; interpolate sample concentrations after blank subtraction. Report as g/dL, g/L, or mg/mL as appropriate, adjusting for dilution factors.
Reaction Conditions
  • Item-specific conditions (reagent volumes, incubation time/temperature, wavelength): Not specified for this item; follow the kit insert strictly.

  • General conditions for hematin-based hemoglobin colorimetry (literature/general):

    • Temperature: Often ambient (20–25°C); some protocols permit room-temperature incubation to completion within minutes.
    • Incubation time: Color typically stabilizes within ~5–20 minutes depending on formulation; verify stability window for reading.
    • Wavelength: Visible absorbance near a method-specific maximum (commonly in the 560–600 nm region for certain hematin chemistries), with a defined pathlength (cuvette) or pathlength-corrected microplate reading.
    • Standards: Prepared from a hemoglobin reference material in the same diluent as samples to minimize matrix effects.
    • Blank: Assay buffer or reagent-only mix without hemoglobin to correct for reagent background.
  • Interference control (general):

    • Turbidity: Clarify samples by gentle centrifugation; avoid filtration media that bind heme.
    • Colored solutes: Bilirubin or heme degradation products can bias readings; consider dual-wavelength or sample pretreatment if recommended.
    • Detergents/chelators: Maintain concentrations consistent with method; validate if lysis buffers are used.
  • Calibration and QC (general):

    • Include a multi-point standard curve (at least 5 points) and check linearity (R² > 0.99 typical for well-behaved assays; literature). Record dilution factors carefully.
Safety and Handling
  • Item-specific hazard data:

    • Signal word, H-statements, GHS classification, pictograms: Not specified for this item; consult the SDS for each component.
  • General laboratory precautions for colorimetric hemoglobin assay kits:

    • Use appropriate PPE: lab coat, safety glasses, and chemical-resistant gloves.
    • Perform procedures with good ventilation; avoid inhalation, ingestion, and skin/eye contact with reagents and biological samples.
    • Treat all biological samples as potentially biohazardous; follow your institution’s biosafety procedures for handling blood or blood-derived materials (e.g., BSL-2 practices where appropriate).
    • This kit is light sensitive per storage guidance; minimize reagent light exposure during handling and storage.
    • Avoid cross-contamination by using fresh pipette tips and segregated areas for standards, samples, and waste.
  • Incompatibilities and storage notes (general):

    • Keep reagents tightly capped; avoid prolonged exposure to air, heat, and light to preserve chromogenic stability.
    • Do not mix components from different lots unless specified by the manufacturer.
  • First aid (overview; defer to SDS):

    • Skin/eye contact: Rinse with water for at least 15 minutes; remove contaminated clothing.
    • Inhalation: Move to fresh air; seek medical attention if symptoms persist.
    • Ingestion: Rinse mouth; seek medical attention. Provide SDS to responders.
  • Waste disposal:

    • Dispose of chemical and biohazardous waste in accordance with local regulations and your institution’s policies. Decontaminate biological residues before disposal.
Solvent Selection

This product is an aqueous colorimetric assay kit, not a standalone solvent.

  • Applicability:

    • Solvent selection is not typically a decision point; the kit’s buffers/reagents define the reaction medium. Do not substitute solvents unless the protocol explicitly allows it.
  • General notes for sample preparation (literature/general):

    • Use high-purity water (e.g., 18 MΩ·cm) for dilutions and washing steps to minimize background.
    • If organic solvents are required for sample lysis or cleanup, ensure they are compatible with the chromogenic reaction and do not absorb at the assay wavelength; verify with small-scale controls. Methanol, ethanol, or detergents can interfere depending on the hematin chemistry; confirm compatibility in the kit insert.
  • Recommendation:

    • Follow the provided buffer system. If matrix effects are observed, consider diluting samples in the assay buffer to maintain solvent composition consistency across standards and samples.
Storage and Reconstitution
  • Item-specific storage (from Product Data):

    • Store at 2–8°C.
    • Protect from light.
    • Shipped on wet ice.
  • Stability and handling (general guidance for similar kits):

    • Do not freeze components unless the kit insert explicitly instructs to do so.
    • Minimize time at room temperature; return reagents to 2–8°C promptly after use.
    • Keep containers tightly closed to limit evaporation and oxidative degradation.
  • Reconstitution (item-specific):

    • Reconstitution details for any lyophilized components: Not specified for this item; refer to the kit insert for solvents, volumes, and equilibration times.
  • Aliquoting and light protection (general):

    • If repeated use is expected, aliquot light-sensitive solutions into amber microtubes to reduce freeze–thaw or light exposure cycles, consistent with the kit instructions.
  • Shelf life:

    • Not specified for this item; consult the product label and CoA for expiration dating.
  • Transportation and field use:

    • Maintain cold chain during transport. Allow components to equilibrate to working temperature before assay to avoid condensation and drift in absorbance readings.
Structure and Identity

Overview of the assay kit components and identity.

  • Item-specific facts (from Product Data):

    • Product: Hemoglobin Content Assay Kit (Hematin, Colorimetric Method) — SKU H1522002
    • Grade: BioReagent
    • Storage: 2–8°C, protected from light; shipped on wet ice
    • Composition/individual reagent identities: Not specified for this item; refer to CoA/Spec Sheet and kit insert.
  • What this kit measures (general description):

    • The kit is designed to quantify total hemoglobin by converting hemoglobin to a hematin species and reading a colorimetric signal proportional to hemoglobin content in the sample.
    • Typical matrices (general): whole blood dilutions, red blood cell lysates, cell/tissue homogenates, or purified hemoglobin preparations.
  • Chemical identifiers:

    • CAS, CID, InChIKey, SMILES, molecular formula, molecular weight (for individual reagents): Not specified for this item; refer to CoA/Spec Sheet.
  • Structural features (general background):

    • Hematin is an oxidized porphyrin iron complex derived from heme/hemin; color development arises from strong Soret/visible-band absorbance of porphyrinoid species (literature). The assay reports total heme-bound hemoglobin after conversion under defined assay conditions.
  • 2D structural description (general):

    • The chromophore responsible for detection is a porphyrin macrocycle coordinated to Fe(III) (literature), but the exact reagent structures and stabilizers in this kit are not itemized here.
Synthetic Utility

This product is an analytical assay kit and is not a synthetic reagent or building block.

  • Not typically applicable:

    • No direct role in bond-forming reactions, functional group interconversions, or materials synthesis.
    • For chemical synthesis related to heme analogs or porphyrins, separate specialized reagents would be required.
  • See instead: Reaction & Applications and Application Protocols for guidance on analytical use.

Target Specificity

This product is not an antibody or affinity reagent; antigen/epitope specificity, clone, isotype, and species reactivity do not apply.

  • Analytical target (general): Total hemoglobin content in samples after conversion to a hematin species.
  • Item-specific cross-reactivity and selectivity data: Not specified for this item; consult the kit insert for any validation notes.

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.