QUALITÀ & PUREZZABioReagent?BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
H₂S is considered the third gas signaling molecule in cells. In plants, it participates in various physiological processes, including growth and development, enhancement of biotic and abiotic stress resistance, and delay of senescence. In animals, it plays a regulatory role in the nervous system, relaxes vascular smooth muscle, and reduces blood pressure.
Under strongly acidic conditions in the presence of Fe³⁺ (as an oxidizing agent), hydrogen sulfide reacts with N,N-dimethyl-p-phenylenediamine to form blue methylene blue, which has a maximum absorption peak at 665 nm. Therefore, the H₂S content in plant tissues can be calculated based on the amount of methylene blue generated.
Specifiche
Specifiche e purezza
BioReagent
Grado
BioReagent
Applicazione
Cell Metabolism
Metodo di rilevamento
Colorimetric Method
Detection instrument
Microplate reader
Detection wavelength
665nm
Stoccaggio e spedizione
Condizioni di conservazione di stoccaggio
Store at 2-8°C,Protected from light
Spedito in
Wet ice
Stabilità e conservazione
Store at 2-8℃ for 6 months. Store in the dark.
Dati avanzati
Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calcolatori di soluzioni
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Recensioni
Recensioni dei clienti
Application Protocols
Item-specific tested applications, recommended dilutions, and positive controls are Not specified for this item; refer to the kit’s Instructions for Use and CoA/Spec Sheet.
Note: While general microplate workflows for H2S assays exist in the literature, protocol steps (reagent volumes, incubation times, wavelengths, standard curve preparation) must be taken from the official documentation for this product to ensure accuracy and reproducibility.
Biological Roles
Hydrogen sulfide (H2S) is a biologically relevant small molecule often referred to as a gasotransmitter alongside NO and CO (literature/general knowledge). It exists in aqueous systems as a pH-dependent mixture of H2S, HS−, and S2−, with HS− predominating near neutral pH.
Biosynthesis and metabolism:
Generated endogenously via the transsulfuration pathway (e.g., cystathionine β-synthase, cystathionine γ-lyase) and 3-mercaptopyruvate sulfurtransferase-dependent routes.
Oxidized and cleared through mitochondrial sulfide oxidation pathways; also scavenged by metalloproteins and reactive species.
Biochemical interactions:
Modulates protein function through persulfidation and metal-center binding (e.g., heme and copper sites).
Interacts with reactive oxygen/nitrogen species, influencing cellular redox status.
Research implications:
Quantifying H2S and HS− pools helps dissect sulfur metabolism, redox biology, and enzymology in cells, tissues, and microbes.
Matrix effects are substantial: proteins, thiols, and metals can buffer, sequester, or consume sulfide, complicating measurement.
This kit provides a research tool to quantify H2S content; it is not intended for diagnostic use. For the most accurate biology-driven insights, pair concentration data with time-resolved studies and controls that account for production, consumption, and volatilization equilibria.
Buffer Applications
While this is not a buffer product, assay performance depends on the buffer system used during sample prep and reaction (literature/general guidance; not item-specific).
General guidance:
Use the kit-provided buffer(s) where supplied. If substituting, select low-metal, oxygen-controlled aqueous buffers (e.g., degassed HEPES or phosphate) validated not to interfere with the detection chemistry.
Avoid high concentrations of competing thiols (DTT, β-mercaptoethanol), strong oxidants, nitrosating agents, or transition metals that can consume sulfide.
Maintain consistent ionic strength across standards and samples to avoid activity coefficient artifacts.
Practical tips:
Prepare fresh, degassed buffers; consider adding chelators only if validated not to suppress the assay signal.
Minimize headspace and use sealing films/caps to limit H2S volatilization.
Include matrix-matched blanks and spike recoveries to assess compatibility.
pH considerations:
H2S/HS− speciation is pH-dependent; ensure standards and samples share the same pH as the reaction buffer to maintain linear calibration (typical assays operate in mildly acidic to neutral range; follow kit IFU for specifics).
Exact formulations, permissible additives, and any proprietary buffer components for this item are Not specified for this item; refer to CoA/Spec Sheet.
Green Alternatives
Hydrogen sulfide quantification historically used lead acetate papers or large-volume wet-chemical analyses. A micro-scale assay kit offers greener, safer, and more efficient practice.
Advantages of micro-format (general, not item-specific):
Reduced reagent and sample volumes, lowering chemical consumption and hazardous waste.
Aqueous buffers in place of large volumes of organic solvents.
Streamlined workflows compatible with multiwell plates minimize energy use and operator exposure.
Comparison of common approaches (literature/general knowledge):
Lead acetate paper: simple but employs toxic Pb salts and provides semi-quantitative results; waste is hazardous.
Ion-selective electrodes: avoid chromogenic reagents but require careful calibration and ionic strength control; can be greener if buffers are benign.
Fluorogenic/Colorimetric micro assays: small volumes, scalable, high sensitivity; reagent synthesis/disposal impacts are mitigated by micro-scale use.
Implementation tips to enhance sustainability:
Use reusable plate lids instead of single-use films when practical.
Consolidate runs to fully utilize plate capacity and reduce repeat setups.
Collect sulfide-containing wastes in dedicated containers for proper disposal and potential sulfide quenching.
Always balance method performance (sensitivity, selectivity, robustness) with environmental impact; validate greener substitutions (buffers, plastics) to ensure data integrity.
Pharmaceutical Uses
This assay kit is a research tool and is not intended for diagnostic, clinical, or therapeutic use.
Typical roles in a pharmaceutical R&D setting (literature/general knowledge):
Analytical quantification of H2S release from donor compounds in discovery chemistry.
Assessment of redox liabilities and sulfide-related degradation pathways in formulation research.
Support of mechanistic biology studies examining sulfur metabolism in cellular models.
Regulatory note:
Not a pharmacopeial assay; no compendial method is implied. Validation for GMP/GLP use requires internal method validation (accuracy, precision, specificity, linearity, range, LOD/LOQ, robustness) using your matrices and instrumentation.
Excipient/processing role: Not applicable.
Any item-specific certification (e.g., lot release criteria, calibration traceability) is Not specified for this item; refer to CoA/Spec Sheet.
Physical Properties
This is a multi-reagent analytical kit; unified physicochemical constants (bp, mp, density, etc.) do not apply to the assembled product.
Physical form: Not specified for this item; refer to CoA/Spec Sheet.
Molecular formula / molecular weight: Not applicable to the kit; per-item component details are Not specified for this item; refer to CoA/Spec Sheet.
Solubility: Assay is typically conducted in aqueous buffers (literature/general knowledge). Exact component solubilities are Not specified for this item; refer to CoA/Spec Sheet.
pKa/logP/refractive index: Not applicable at the kit level. Any component-specific values are Not specified for this item; refer to CoA/Spec Sheet.
Optical readout (literature/general knowledge):
Colorimetric chemistries commonly employ visible absorption measurement in the red/near-IR for methylene blue assays.
Fluorometric chemistries employ UV–vis excitation/emission of derivatized sulfide adducts.
Note: For precise working concentrations, extinction coefficients, excitation/emission wavelengths, and calibration ranges, consult the kit’s Instructions for Use (IFU) and Certificate of Analysis. Do not extrapolate literature values to this specific product without verification.
Quality and Grades
Grade: BioReagent (per Product Data).
BioReagent-grade components are selected for suitability in biological/biochemical research workflows, emphasizing low background, reproducibility, and compatibility with common biological buffers.
What this means in practice:
Emphasis on batch-to-batch consistency for absorbance/fluorescence response.
Documentation typically includes instructions and, where applicable, a standard curve procedure to support quantitative work (refer to kit IFU/CoA).
Reduced levels of common interferents for biochemical assays (general positioning; not a specification).
Item-specific specifications (purity %, residual solvent, stabilizers, metal limits, UV cutoff): Not specified for this item; refer to CoA/Spec Sheet.
Qualification and acceptance:
For regulated or GLP environments, verify the kit acceptance criteria, calibration standards, and traceability details in the provided documentation.
Run in-house QC with matrix-matched controls to confirm performance in your sample type (e.g., plasma, cell lysate, culture media), as biological matrices can bind or consume sulfide.
Light sensitivity: Protect from light as indicated; many chromogenic/fluorogenic reagents are photosensitive. Store at 2–8°C as specified.
Reaction and Applications
This assay kit enables quantitative determination of hydrogen sulfide (H2S/HS−) in laboratory samples at micro-scale volumes.
Research applications (literature/general knowledge; not item-specific):
Measurement of endogenous H2S in cell lysates, tissue homogenates, microbial cultures, or buffer systems.
Monitoring enzyme activities in the transsulfuration pathway (e.g., CBS, CSE) via H2S production/consumption.
Evaluation of chemical H2S donors/scavengers and redox-active compounds.
Process monitoring in environmental or bioprocess samples (e.g., sulfide in anaerobic cultures) within a research context.
Analytical concepts:
Standard curves prepared from sodium sulfide or standardized sulfide solutions enable quantitation after matrix-matched calibration.
Micro-format reduces sample/reagent consumption and supports higher throughput.
Practical tips (general):
Prepare fresh sulfide standards immediately before use; sulfide is air- and metal-sensitive and can volatilize or oxidize.
Work rapidly and consistently; control temperature and timing to maintain reproducibility.
Use sealed microplates or cover films to limit sulfide loss; pre-equilibrate buffers to assay temperature.
Include sample blanks and spike-recovery controls to assess matrix interference.
Note: For exact sample prep, reaction times, detection wavelength, and calculation steps for this specific kit, follow the product IFU. Do not substitute literature parameters without verification.
Reaction Conditions
Exact reaction conditions for this product are not provided here; follow the kit’s Instructions for Use. The following are literature/general guidance for common H2S assays and are not item-specific:
Colorimetric methylene blue chemistry:
Medium: Aqueous, acidic (mineral acid), presence of an oxidant (e.g., Fe3+).
Temperature: Ambient (20–25°C) is common; maintain consistent temperature across standards and samples.
Timing: Fixed incubation windows improve precision; reaction typically reaches endpoint within tens of minutes depending on formulation.
Detection: Visible absorbance of the dye; use matched pathlength (microplate pathlength correction can be helpful).
Fluorometric thiol-derivatization chemistry:
Medium: Aqueous buffers; sometimes includes organic cosolvent at low percentage to solubilize probe.
pH: Often near neutral to mildly basic for nucleophilic substitution on electrophilic probes.
Light: Protect from light to prevent probe photobleaching.
Detection: Excitation/emission per probe’s spectral profile; calibrate instruments accordingly.
General controls:
Prepare fresh sulfide standards immediately before use.
Include reagent blanks, matrix blanks, and spike recoveries to detect interference.
Use sealed plates/tubes to minimize volatilization and oxidation by air.
Expected yields or sensitivities depend strongly on chemistry and matrix; consult the kit’s documentation for verified limits of detection, linear ranges, and calculation examples.
Safety and Handling
GHS classification, signal word, hazard statements, and pictograms: Not specified for this item; consult the product SDS for authoritative safety information.
Storage: Store at 2–8°C, protected from light (per Product Data). Shipped on wet ice.
General hazards (literature/general knowledge for H2S assay kits; not item-specific):
Kits may include acidic solutions, oxidants, amines, metal salts, or thiol-reactive reagents; treat as corrosive/irritant/oxidizing as applicable.
Hydrogen sulfide is a toxic, flammable gas; however, this kit quantifies trace sulfide in contained samples. Avoid generating free H2S by maintaining buffers and closures; handle samples in a fume hood if sulfide off-gassing is possible.
PPE: Laboratory coat, nitrile gloves, and splash-resistant safety glasses at minimum. Use a certified fume hood for steps with volatile sulfide or strong acids/bases.
Incompatibilities (general): Strong acids can liberate H2S from sulfide-containing samples; strong oxidizers and metals may consume sulfide before measurement, biasing results. Segregate acids, bases, and oxidizers per SDS guidance.
First aid (overview; defer to SDS):
Skin/eye contact: Rinse with water for ≥15 minutes; remove contaminated clothing.
Inhalation of any vapors: Move to fresh air; seek medical attention.
Ingestion: Rinse mouth; seek medical attention. Provide SDS to responders.
Waste: Collect assay waste according to local regulations for sulfide- and dye-containing solutions; neutralize/react per institutional procedures.
Solvent Selection
This product is an aqueous assay kit rather than a standalone solvent. Solvent selection is generally not applicable beyond the buffers provided or recommended in the kit.
Perform the assay in the supplied buffer(s) or validated equivalents. Avoid organic cosolvents unless specifically validated, as they can alter chromophore formation or fluorescence.
Minimize headspace and agitation that could strip dissolved H2S.
Avoid metal-contaminated glassware and buffers; trace metals can catalytically oxidize sulfide.
Compatibility:
Typical biological buffers (e.g., phosphate, HEPES) may be compatible, but phosphate or amines can interact with certain dye systems; follow the kit IFU.
High concentrations of thiols (e.g., DTT, β-mercaptoethanol) or oxidants (e.g., hydrogen peroxide) can confound sulfide measurements; minimize or account for these.
When method development is required (e.g., matrix changes), pilot runs comparing the kit buffer versus the candidate buffer will help quantify any solvent/buffer effects on signal and background.
Storage and Reconstitution
Storage conditions: Store at 2–8°C, protected from light (per Product Data). Shipments are on wet ice.
Stability and shelf life: Not specified for this item; refer to CoA/Spec Sheet and label.
Reconstitution/Preparation:
Component-specific reconstitution instructions, diluents, and working solution stability are Not specified for this item; refer to the kit Instructions for Use.
General guidance (not item-specific): Prepare working reagents shortly before use; protect light-sensitive solutions; equilibrate to assay temperature; avoid repeated warming/cooling cycles of frozen or chilled components.
Handling:
Keep containers tightly closed to limit atmospheric oxidation and evaporation.
For multi-use vials, aliquot when feasible to reduce contamination and preserve performance.
Shipping and receipt:
Inspect upon arrival to confirm temperature control and absence of leaks; store immediately at 2–8°C, protected from light.
Always consult the product insert for detailed storage after reconstitution, allowed freeze–thaw cycles (if any), and component-specific precautions.
Structure and Identity
Hydrogen Sulfide Content Assay Kit (Micro Method) is a multi-component analytical kit designed to quantify H2S in research samples using a micro-scale format (e.g., microcuvette or microplate wells).
Item type: Biochemical assay kit comprising reagents, standards, and buffers for hydrogen sulfide quantification.
Intended use: For research use only (per Product Data).
Structural identifiers (for the kit as a whole): Not applicable.
Component-level identifiers (molecular formula, MW, SMILES, InChIKey): Not specified for this item; refer to CoA/Spec Sheet.
Typical assay chemistries (literature/general knowledge, not item-specific):
Colorimetric “methylene blue” formation from sulfide in acidic oxidizing media.
Thiol-derivatization (e.g., monobromobimane) with subsequent fluorescence detection.
Format: "Micro Method" indicates low-volume reactions suitable for 96-/384-well plates or microcuvettes, enabling high-throughput and reduced reagent consumption.
2D structure note: Not applicable to a kit; the analytical readout depends on reaction of H2S (or HS−) with the provided chromogenic/fluorogenic reagent(s), rather than a single fixed molecular structure.
Synthetic Utility
As an analytical kit, this product is not a synthetic building block. However, understanding the underlying chemistry can inform method adaptation (literature/general knowledge; not item-specific):
Methylene blue-forming assays: Sulfide reacts with N,N-dimethyl-p-phenylenediamine in the presence of an oxidant (e.g., Fe3+) under acidic conditions to form methylene blue, a chromophore measurable in the visible region.
Electrophilic thiol-tagging: Sulfide or its oxidation products can be derivatized with haloalkyl or maleimide reagents (e.g., monobromobimane) to create fluorescent adducts for sensitive detection.
Metal complexation approaches: Sulfide binds strongly to soft metal centers (e.g., Cu, Ag, Hg) forming complexes or precipitates; while useful analytically, they may lack selectivity in complex matrices.
Utility for chemists:
Enables kinetic profiling of chemical H2S donors and scavengers, facilitating structure–activity relationship (SAR) studies.
Supports stability studies by monitoring sulfide produced/consumed during redox or hydrolytic processes.
Provides calibration references to correlate synthetic release rates with biological assay results.
For this specific kit, do not assume a particular detection chemistry; rely on the kit documentation for the exact reaction mechanism and any constraints on additives, pH, or solvents.
Target Specificity
Target specificity data (e.g., antigen, epitope, clone, isotype) are not applicable to this product type. This is an analytical assay kit for hydrogen sulfide content and does not involve immunorecognition components in the sense of antibody target specificity. Any selectivity profile versus thiols, polysulfides, or oxidants for this specific kit is Not specified for this item; refer to CoA/Spec Sheet.
Domande frequenti
What does BioReagent mean?
BioReagent indicates that the product has been processed and tested for biological and biochemical applications. Specifications may include endotoxin limits, microbial controls, sterility, low DNase/RNase/protease activity, and verified biological activity where relevant.
How should this product be stored?
Store at 2–8 °C, protected from light. The material is light-sensitive — keep it in its original opaque or amber container.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Hai bisogno di aiuto per scegliere la qualità?
La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.
Utilizziamo i cookie per garantire il corretto funzionamento del sito web e, ove consentito, per migliorare la tua esperienza. Puoi gestire le tue preferenze in qualsiasi momento nelle Impostazioni. Per saperne di più, consulta la nostra Cookie Policy.
Desidera che le inviamo un messaggio quando avremo sconti disponibili?
Ricordamelo più tardi
Grazie! Controlli la sua casella di posta per confermare.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.