Hydroxyl Radical Content Assay Kit (Colorimetric Method)

Cat. No.: H1522193
Disponibile su ordine
QUALITÀ & PUREZZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
48T
H1522193-48T
Su ordinazione · 8–12 settimane
156,11€
Enter a quantity for the sizes you want to add.
🧪
Perché questa qualità

BioReagent BioReagent per flussi di lavoro cromatografici e analitici sensibili che richiedono un'interferenza minima della linea di base.

🌡

Stoccaggio e spedizione

Store at 2-8°C,Protected from light Spedizione Wet ice. Consultare il COA specifico del lotto per le specifiche esatte.

📋

Documenti di qualità

SDS, COA, scheda tecnica e scheda delle specifiche disponibili per il download. COA specifico del lotto accessibile tramite ricerca per numero di lotto.

📚

Prova documentale

Citato in 0 pubblicazioni peer-reviewed su cromatografia, sintesi organica e reazioni di accoppiamento incrociato.

Panoramica

The hydroxyl radical (OH⁻) is a type of reactive oxygen species. In the presence of hydroxyl radicals, 2-deoxyribose is oxidized to a malondialdehyde-like compound, which then condenses with thiobarbituric acid (TBA) to form a colored product. The hydroxyl radical content is calculated by measuring the maximum absorption peak of this colored product at 532 nm.

Specifiche

Specifiche e purezza
BioReagent
Grado
BioReagent
Applicazione
Cell Metabolism
Metodo di rilevamento
Colorimetric Method
Detection instrument
Visible Spectrophotometer
Detection wavelength
532nm
Stoccaggio e spedizione
Condizioni di conservazione di stoccaggio
Store at 2-8°C,Protected from light
Spedito in
Wet ice
Stabilità e conservazione
Store at 2-8℃ for 6 months. Store in the dark.

Documentazione

📋 Scheda di dati di sicurezza (SDS)

Documento completo su pericoli, manipolazione, stoccaggio e conformità normativa.

<<<<<<< HEAD Scarica SDS → ======= Scarica SDS → >>>>>>> release248-p3

✅ Certificato di analisi (COA)

Dati di qualità specifici del lotto. Inserisci il numero di lotto per recuperare il COA esatto.

Cerca COA →

📊 Scheda tecnica

Riepilogo di riferimento rapido delle specifiche e applicazioni del prodotto.

Visualizza scheda tecnica →

🔬 Scheda delle specifiche

Attributi di qualità completi e criteri di accettazione per questa qualità.

Visualizza scheda delle specifiche →

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Domande frequenti e articoli
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Application Protocols

Follow the kit’s IFU for definitive instructions. The outline below provides a generalized workflow for a colorimetric hydroxyl radical content assay in microplate format (literature-based, for orientation only):

  • Preparation

    • Equilibrate all components to room temperature and protect light-sensitive reagents from exposure.
    • Prepare standards across the recommended range and a reagent blank per IFU.
    • Clarify biological samples by centrifugation; if needed, dilute to fall within the linear range.
  • Assay setup (example framework; do not substitute for IFU)

    • In a clear 96-well plate, add sample or standard to designated wells.
    • Add the working reagent freshly prepared as described in the IFU.
    • Mix gently and incubate for the specified time and temperature (e.g., 15–60 min; dark).
  • Measurement

    • Read absorbance at the specified wavelength using a plate reader. If recommended, read a reference wavelength for background correction.
  • Calculations

    • Construct a standard curve (linear or 4PL, per IFU). Calculate sample values after blank subtraction and dilution corrections.
    • Report results as concentration or percent scavenging relative to control, including replicate statistics.
  • QC/controls

    • Include a positive control (validated generator) and negative control (no •OH) if recommended.

Note: Volumes, concentrations, and λ must match the IFU. For cuvette formats, scale volumes accordingly and ensure pathlength consistency.

Biological Roles

Hydroxyl radical (•OH) is a highly reactive reactive oxygen species (ROS) generated in biological systems, notably via Fenton and Haber–Weiss chemistry, where reduced transition metals (e.g., Fe2+) react with peroxides (literature).

Key roles and impacts (literature/general):

  • Reactivity: •OH exhibits diffusion-limited reaction rates with biomolecules, driving nonspecific oxidation of lipids, proteins, carbohydrates, and nucleic acids. It can initiate lipid peroxidation, induce protein carbonylation, and cause DNA strand breaks/base modifications.
  • Sources: Mitochondrial electron transport chain leakage, NADPH oxidases, xanthine oxidase activity, and inflammatory responses can lead to upstream ROS that form •OH in the presence of catalytic metals.
  • Compartmentalization: Given its ultrashort lifetime (ns) and limited diffusion radius, formation and damage are highly localized.
  • Cellular response: Cells activate antioxidant defenses (glutathione, catalase, peroxiredoxins) and repair pathways (DNA repair enzymes, proteostasis mechanisms) in response to oxidative damage.

Relevance of measurement (general):

  • Quantifying •OH-associated reactivity enables assessment of oxidative stress status, evaluation of antioxidant interventions, and characterization of pro-oxidant conditions in vitro.

This kit provides a colorimetric route to track •OH-related chemistry; interpret results within the context of total ROS and antioxidant capacity of the studied system. No clinical/diagnostic use is intended.

Buffer Applications

This product is not itself a buffer system. However, buffers are central to assay reliability.

General guidance (literature; follow IFU for allowed buffers):

  • Preferred media: Neutral aqueous buffers (e.g., phosphate-based) are commonly used for biological samples; verify buffer type and concentration with the IFU.
  • Avoid: Strong chelators (EDTA, DTPA) or excess citrate that can sequester metals and suppress hydroxyl radical formation in Fenton-type chemistries. Similarly, strong antioxidants (ascorbate, excess thiols) may quench signal.
  • pH control: Maintain pH near physiological (≈7.0–7.4) unless the method specifies otherwise; •OH generation and probe reactivity are pH-sensitive.
  • Clarity: Filter or centrifuge to remove particulates that cause light scattering in colorimetric readouts.
  • Blank/controls: Prepare buffer-only blanks and matrix-matched controls to quantify background absorbance and matrix effects.

If the kit supplies a dedicated assay buffer, use it exclusively for standards and samples to ensure method-equivalent ionic strength and pH. When substituting buffers during method development, perform recovery experiments to confirm equivalence.

Green Alternatives

While this product is an aqueous colorimetric kit (already comparatively benign versus organic-solvent-heavy analytics), greener practices can further reduce environmental footprint.

  • Solvent minimization: Run assays in 96- or 384-well plates to reduce per-sample reagent volumes and waste.
  • Waste segregation: Collect oxidant-containing waste separately and neutralize per institutional EHS guidelines. Avoid unnecessary chlorinated organic solvents for cleanup.
  • Safer reagents: If optional cosolvents are needed, prefer ethanol or water over high-toxicity solvents, within IFU allowances (general guidance).
  • Energy efficiency: Perform incubations at ambient temperature when validated by the IFU, minimizing heated incubations.
  • Reuse of consumables: Use reusable, glass cuvettes for cuvette-based methods when compatible; otherwise, choose recyclable plastics.

Comparison (general, literature-based):

  • Aqueous colorimetry vs fluorescence with organic dyes: Colorimetry often avoids specialized fluorescent probes and can use simpler aqueous buffers, lowering solvent and dye hazards.
  • Microplate formats vs cuvettes: Microplates reduce total reagent volume by 5–20×, decreasing chemical consumption and waste.

Note: Do not alter the validated chemistry or storage to “greenify” the method unless you have verified equivalence. Follow the IFU and your EHS policies when implementing greener practices.

Pharmaceutical Uses

This product is for research use only and is not intended for diagnostic or clinical applications. It is not an excipient.

Relevant research-oriented applications in pharmaceutical and bioprocess settings (general):

  • Screening of API/excipient antioxidant capacity or pro-oxidant liability under formulation-relevant conditions.
  • Monitoring stress studies (ICH-like heat/light/oxidative challenges) by tracking changes in hydroxyl-radical-associated reactivity in model systems.
  • Evaluating container–closure interactions or trace metal catalysis leading to increased ROS formation in solution.
  • Supporting comparability studies for biologics by monitoring oxidative environments in sample preparations.

Operational considerations:

  • Use matrix-matched calibration when working in buffered formulations that may contain UV–Vis absorbing components (surfactants, dyes, amino acids).
  • Validate linearity, LOD/LOQ, precision, and robustness per internal SOPs before adopting the assay for QC-supporting research.
  • Document instrument settings, incubation times, and acceptance criteria for in-study controls to maintain data integrity.

Any adaptation for GMP-related research must be qualified internally; consult your QA/EHS teams for documentation and disposal practices.

Physical Properties

As an assay kit comprised of multiple reagents, there is no single set of physical constants for the entire product.

Item-specific data:

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Refractive index, density, pH of buffers, extinction coefficients: Not specified for this item; refer to CoA/Spec Sheet.
  • Storage: 2–8°C, protected from light (item-specific). Shipped on wet ice (item-specific).

General/literature guidance for colorimetric hydroxyl radical assays (informational only; consult the IFU for exact specifications):

  • Typical measurement is performed in aqueous buffer at ambient temperature (20–25°C) or 37°C, depending on the protocol.
  • The readout is usually recorded on a UV–Vis spectrophotometer or microplate reader at a visible wavelength characteristic of the product chromophore (e.g., often in the 500–600 nm range; exact λmax is method-dependent and should be taken from the IFU) (literature).
  • Solubility considerations: Most components are water-based; if any organic cosolvent is recommended (e.g., DMSO for standards), it will be specified in the IFU. Avoid high percentages of organic solvent that can quench radical chemistry (general guidance).
  • Reaction kinetics: Color development periods commonly range 15–60 min (literature) before absorbance stabilization.

Important: Do not treat these general values as specifications; follow the product’s Instructions For Use (IFU) for all operational parameters.

Quality and Grades
  • Item grade: BioReagent (item-specific). This designation typically indicates suitability for biological research workflows, with attention to impurity profiles that could interfere with biochemical reactions, spectrophotometric measurements, or enzymatic steps (general meaning).
  • UV transparency: For colorimetric reading in the visible region, low background absorbance of buffers and reagents is critical; BioReagent-grade formulations generally minimize interfering chromophores (general context).
  • Lot-to-lot consistency: Assay kits are commonly standardized to deliver reproducible color development against supplied or method-defined standards. However, specific QC metrics (e.g., acceptance criteria for control recoveries, linear range) are not specified for this item; refer to CoA/Spec Sheet.
  • Stabilizers/preservatives: The presence or absence of stabilizers (e.g., antioxidants, antimicrobial agents) can influence baseline absorbance and shelf life. For this item, stabilizer content is not specified; refer to CoA/Spec Sheet.
  • Documentation: For regulated laboratory environments, retain the CoA, SDS, and IFU and record instrument parameters (wavelength, pathlength/plate type, incubation time/temperature) for traceability.

Practical guidance:

  • Calibrate the microplate reader or spectrophotometer at the specified wavelength in the IFU before first use.
  • Establish in-house system suitability by running the provided or recommended controls/standards with each new lot to verify linearity and sensitivity (general best practice).
Reaction and Applications

Primary application: quantification of hydroxyl radical (•OH) content in biological and environmental samples via a colorimetric readout.

Use cases (research-only):

  • Assessing oxidative stress in cell/tissue lysates, plasma/serum (after deproteinization if recommended), or culture media (general).
  • Screening antioxidant capacity of small molecules, natural products, or formulations toward •OH scavenging (literature).
  • Monitoring Fenton-type reactions (Fe2+/H2O2 systems) and related ROS generation in model systems (literature).

Practical tips (general; follow IFU):

  • Calibration: Prepare a standard curve using the kit’s standard or a method-defined calibrant. Include blank and matrix-matched controls.
  • Sample prep: Clarify samples by centrifugation/filtration to remove particulates. Minimize intrinsic color by dilution if within linear range. Avoid chelators and strong reducing agents unless allowed.
  • Kinetics: Maintain consistent incubation time and temperature; start timing immediately after adding the working reagent.
  • Interferences: Colored compounds, turbidity, and strong antioxidants/scavengers can depress or elevate absorbance. Run spike-recovery controls to assess matrix effects.
  • Instrumentation: Use a microplate reader or cuvette spectrophotometer at the specified wavelength in the IFU; zero with the appropriate blank.

Data treatment:

  • Report data as absolute concentration (vs standards) or as relative activity/scavenging % vs controls. Include n≥3 replicates and report mean ± SD with the calibration R² for rigor.
Reaction Conditions

Exact operating parameters for this item are defined in the kit’s IFU and must be followed. The points below summarize common conditions from the literature for colorimetric hydroxyl radical assays and are provided for context only.

Typical ranges (literature/general):

  • Temperature: Room temperature (20–25°C) or 37°C for biologically relevant kinetics.
  • Incubation time: 15–60 minutes until color development stabilizes; timing must be consistent across standards and samples.
  • Wavelength: A visible λmax typically within 500–600 nm depending on the probe/product chromophore. Use the exact wavelength specified in the IFU.
  • Pathlength/format: 96-well clear plates (200–300 µL per well) or 1 cm cuvette measurements; ensure linearity within the instrument’s absorbance range (generally A ≤ 1.5).
  • Blanks/controls: Include reagent blank, sample blank (sample matrix without reactive probe), and positive control (known •OH generator) where appropriate.
  • Kinetic vs endpoint: Endpoint reading after fixed incubation is common; some methods allow kinetic monitoring for reaction rate analysis.

Critical cautions:

  • Maintain identical timing and temperature across the standard curve and samples to minimize bias.
  • Avoid strong chelators or antioxidants unless the protocol specifies them; they can suppress signal.
  • For turbid/colored samples, consider background correction at a reference wavelength or perform sample cleanup (centrifugation/filtration) before measurement.

Always use the IFU as the source of truth for volumes, reagent preparation, and timing.

Safety and Handling

Hazard communication for this specific kit has not been provided.

Item-specific safety data:

  • GHS Classification, Signal Word, H-Statements, Pictograms: Not specified for this item; refer to SDS.
  • Storage: Store at 2–8°C, protected from light (item-specific). Avoid repeated freeze–thaw of any liquid enzyme or chromogenic components if present (general precaution; follow IFU).

General laboratory precautions for colorimetric ROS assay kits (informational; defer to SDS/IFU):

  • PPE: Lab coat, safety glasses, and appropriate chemical-resistant gloves. Work in a well-ventilated area; a fume hood is recommended when handling concentrated reagents.
  • Potential incompatibilities: ROS assays may involve oxidants, metal salts, or peroxides and may be incompatible with strong reducers, amines, bases/acids, or metal chelators that impair assay performance. Do not mix unknown reagents; follow IFU strictly.
  • Light sensitivity: Many chromogenic reagents are photosensitive. Keep vials protected from light; minimize exposure during setup.
  • Contamination control: Use high-purity water and clean, metal-free plasticware if metal-catalyzed reactions are involved. Avoid carryover of detergents or colored compounds from samples.
  • First aid (overview; consult SDS): In case of skin/eye contact, rinse with water for 15 minutes and remove contaminated clothing. If inhaled, move to fresh air. If ingested, rinse mouth; seek medical attention in all cases of exposure.

Always consult the product SDS for authoritative hazard, handling, and disposal instructions.

Solvent Selection

This is an aqueous colorimetric assay kit; conventional solvent selection for organic synthesis is not applicable. Nevertheless, solvent and matrix effects are pivotal for data quality.

  • Primary medium: Aqueous buffers (item-specific compositions are not provided). Use freshly prepared, high-purity water (≥18 MΩ·cm) to minimize background.
  • Organic cosolvents: If the IFU permits, keep any DMSO/ethanol content low (typically ≤1–2% v/v; literature) to avoid altering radical generation and probe reactivity. Follow the IFU for exact limits.
  • Miscibility/interference:
    • Avoid colored, turbid, or highly viscous sample matrices without appropriate clarification; they can bias absorbance readings.
    • Metal chelators (e.g., EDTA) or strong antioxidants present in samples may quench signal (literature).
  • Device compatibility: Verify your microplate type (clear, flat-bottom) matches the reader’s optical path. Plastic plates generally suffice for visible wavelengths.

Simple comparison (general guidance; verify in IFU):

  • Ultrapure water: Lowest background; preferred for standards and blanks.
  • PBS/Tris buffers: Convenient for biological samples; avoid additives that absorb strongly in the visible range or scavenge radicals.
  • High-organic media: Not recommended unless specifically validated, as they can modify radical chemistry and extinction coefficients.
Storage and Reconstitution

Item-specific storage and shipping:

  • Storage conditions: Store at 2–8°C, protected from light.
  • Shipped in: Wet ice.

Reconstitution and preparation (general guidance; consult IFU for exact instructions):

  • Allow reagents to equilibrate to room temperature before opening to minimize condensation.
  • Prepare fresh working solutions immediately prior to use; many chromogenic/oxidative reagents are unstable once mixed.
  • Use ultrapure water (≥18 MΩ·cm) or the supplied buffer to reconstitute lyophilized components, if applicable. Do not substitute buffers unless verified compatible.
  • Protect reconstituted light-sensitive components by wrapping tubes/plates in aluminum foil or using amber containers.
  • Avoid repeated freeze–thaw cycles; if long-term storage of reconstituted solutions is allowed, it will be specified in the IFU. Otherwise, prepare only what is needed for the day.
  • Label working solutions with date/time and discard after the recommended window to prevent drift in blank and control responses.

Stability/expiry: Specific shelf life, post-reconstitution stability, and permissible storage temperatures for individual components are not specified for this item; refer to CoA/Spec Sheet.

Disposal: Dispose of unused reagents and biological samples according to your institution’s chemical and biohazard waste procedures and the SDS.

Structure and Identity

This product is a multi-component analytical kit designed to quantify hydroxyl radicals (•OH) via a colorimetric readout. It is not a single defined chemical substance.

  • Item type: Assay kit (colorimetric method) for hydroxyl radical content
  • SKU: H1522193
  • Grade: BioReagent (item-specific)
  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • CAS/SMILES/InChIKey: Not applicable to a kit; individual component identifiers are not provided.

Structural features (general knowledge):

  • Colorimetric •OH assays typically rely on oxidation or hydroxylation of a probe to form a chromophore measurable at a defined visible wavelength. The underlying chemistry often involves radical-mediated transformation of an aromatic or heteroaromatic probe, or dye coupling after radical generation (literature, general principle).
  • Hydroxyl radical itself is non-selective, extremely reactive, and has an ultrashort lifetime; the assay quantifies reaction products formed with a capture probe rather than detecting •OH directly (literature).

2D structure description: Not applicable (kit). If component structures are required, consult the kit’s IFU or individual SDS/CoA for each vial.

Synthetic Utility

As an analytical kit, this product is not a synthetic reagent. However, in chemical research it can inform synthesis- and materials-oriented studies.

Representative uses (general):

  • Measuring radical-scavenging properties of candidate antioxidants, ligands, or polymer additives designed for stabilization of fuels, lubricants, elastomers, or photoresists.
  • Evaluating metal-catalyzed oxidation models (e.g., Fe/Cu-mediated Fenton systems) relevant to process chemistry, where controlling ROS can improve reaction selectivity and minimize byproducts.
  • Comparing formulation excipients for their impact on radical generation, aiding selection of stabilizers in preformulation research.

Retrosynthetic/transformational insight (conceptual):

  • Hydroxyl radical reactions illustrate nonselective, diffusion-controlled pathways leading to hydroxylation and oxidative cleavage. Understanding these pathways can guide selection of protective groups, radical inhibitors, or oxygen-free conditions during sensitive synthetic steps.

Methodological note:

  • For structure–activity investigations, pair the colorimetric •OH readout with orthogonal analytics (e.g., HPLC for degradation products, EPR spin trapping for radical profiling) to develop mechanistic insight. Use identical buffer and temperature conditions across candidates to ensure comparability.
Target Specificity

This product is not an antibody or affinity reagent; there is no biological “target” in the immunochemical sense.

  • Assay specificity (general concept): The colorimetric signal arises from hydroxyl-radical-driven reactions with a probe to form a detectable chromophore. While designed to reflect •OH activity, related ROS, sample matrix components, or metal chelation can influence the signal (literature).
  • Item-specific antigen/epitope/isotype/clone/species reactivity: Not applicable.

Hai bisogno di aiuto per scegliere la qualità?

La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.

Visualizza la guida alle qualità BioReagent →

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.