Iprobenfos standard solution - analytical standard, 100ug/ml in acetone , CAS No.26087-47-8

CAS: 26087-47-8 Cat. No.: I114924 Formula: C13H21O3PH Peso molecolare: 288.32 Beilstein Registry Number: 1974687 Numero EC: 247-449-0
Disponibile su ordine
QUALITÀ & PUREZZA Analytical standard ? Analytical standard — certified-purity material for quantitative calibration. Use to prepare calibration standards and validate analytical methods. 100ug/ml in acetone
Synonyms
Iprobenfos|O,O-Bis(1-methylethyl) S-(phenylmethyl) phosphorothioate|Kitazin P
Storage
Room temperature
Shipped In
Normal
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
1ml
I114924-1ml
—
3 Disponibile

33,76€

51,11€
Salva 17,35 € (33.96%)
Enter a quantity for the sizes you want to add.

Specifiche

Sinonimi
Iprobenfos | O,O-Bis(1-methylethyl) S-(phenylmethyl) phosphorothioate | Kitazin P
Specifiche e purezza
analytical standard, 100ug/ml in acetone
Condizioni di conservazione di stoccaggio
Room temperature
Spedito in
Normal
Grado
Standard analitico
Nomi e identificatori
Isomeri SMILES
CC(C)OP(=O)(OC(C)C)SCC1=CC=CC=C1
WGK Germania
1
Numero UN
3082
Gruppo di imballaggio
III
Peso molecolare
288.32
Beilstein
1974687
Reaxys
1974687
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=1974687&ln=

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

3 results found

Lot NumberCertificate TypeDataOggetto
F2102319F2102319Certificate of AnalysisSep 01, 2026 I114924
G2227922G2227922Certificate of AnalysisFeb 04, 2026 I114924
A2206409A2206409Certificate of AnalysisJul 15, 2025 I114924
Proprietà chimiche e fisiche
Punto di infiammabilità (°C)11°C
Punto di ebollizione (°C)126°C
Sicurezza e pericoli (GHS)
Pictogrammi
GHS02,   GHS07
Segnale
Danger
Indicazioni di pericolo

H225:Highly Flammable liquid and vapor

H316:Causes mild skin irritation

H319:Causes serious eye irritation

H336:May cause drowsiness or dizziness

Precauzioni

P210:Keep away from heat, hot surface, sparks, open flames and other ignition sources. - No smoking.

P233:Keep container tightly closed.

P240:Ground/bond container and receiving equipment.

P241:Use explosion-proof [electrical/ventilating/lighting/.../] equipment.

P242:Use only non-sparking tools.

P243:Take precautionary measures against static discharge.

P261:Avoid breathing dust/fume/gas/mist/vapors/spray.

P264:Wash hands [and …] thoroughly after handling.

P271:Use only outdoors or in a well-ventilated area.

P280:Wear protective gloves/protective clothing/eye protection/face protection.

P312:Call a POISON CENTER or doctor/... if you feel unwell.

P303+P361+P353:IF ON SKIN (or hair): Take off Immediately all contaminated clothing. Rinse SKIN with water [or shower].

P304+P340:IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P305+P351+P338:IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do - continue rinsing.

P332+P313:IF SKIN irritation occurs: Get medical advice/attention.

P337+P313:IF eye irritation persists: Get medical advice/attention.

P370+P378:In case of fire: Use ... to extinguish.

P405:Store locked up.

P403+P233:Store in a well-ventilated place. Keep container tightly closed.

P403+P235:Store in a well-ventilated place. Keep cool.

P501:Dispose of contents/container to an approved waste disposal plant.

WGK Germania
1
Reaxys
1974687
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=1974687&ln=
Classe
9
Citations of This Product
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Application Protocols

General workflows for using an analytical standard solution of iprobenfos (guidance only; adapt to your method and consult the CoA for concentration):

  • Preparation of calibration standards:

    • Bring the stock standard to room temperature; vortex gently.
    • Prepare serial dilutions gravimetrically or with class-A volumetrics in a solvent matched to your analytical method (e.g., ACN or MeOH for LC–MS/MS; isooctane or hexane for GC).
    • Use amber autosampler vials with PTFE-lined caps; label with concentration, date, and lot.
  • Matrix-matched calibration:

    • Extract blank matrix using your validated protocol (e.g., QuEChERS).
    • Spike post-extraction with appropriate volumes of the working standards to generate matrix-matched levels spanning expected concentrations.
  • Spike-recovery (accuracy) tests:

    • Fortify test portions at low/mid/high levels using the standard; process through the full extraction/cleanup workflow.
    • Calculate recoveries and RSDs; assess matrix effects by comparing to solvent-only calibration.
  • System suitability:

    • Inject mid-level standard at start/end of sequence to monitor response stability and retention time drift.
    • Monitor ion ratios (LC–MS/MS) or qualifier ions (GC–MS) for identification criteria.

Note: Exact concentrations, injection volumes, and solvent composition must be based on the CoA and your validated method.

Biological Roles

Contextual information for the analyte (literature; not product specifications or claims):

  • Iprobenfos (IBP) is an organophosphorus fungicide historically used in crop protection (e.g., rice) against fungal pathogens. It is considered a systemic fungicide that moves within plant tissues.
  • Mode-of-action discussions in the literature describe organophosphorus fungicides as affecting fungal metabolic processes; precise molecular targets for iprobenfos are less clearly defined compared to azoles or strobilurins. It is not primarily characterized as a cholinesterase inhibitor (unlike certain OP insecticides).
  • Environmental fate: undergoes hydrolysis and biotransformation, leading to cleavage of the P–S–benzyl bond and/or de-esterification at phosphorus; metabolites can include benzyl-containing sulfur species and dialkyl phosphate derivatives (general patterns for aryl phosphorothioates).

Relevance for laboratory work:

  • Understanding hydrolytic susceptibility helps design sample preparation (avoid strongly basic aqueous steps that can degrade the analyte).
  • Metabolite knowledge assists in LC–MS/MS method development for comprehensive monitoring (parent plus degradates), if required by the study design.

No biological/clinical use is implied; this product is strictly for research and analytical purposes.

Buffer Applications

Not typically applicable. Iprobenfos is a hydrophobic organophosphorus analyte used as a pesticide standard and is not employed to formulate biochemical buffers. For practical guidance, see Solvent Selection and Reaction & Applications for analytical method considerations.

Green Alternatives

Because this is an analytical standard, the “greenness” considerations focus on solvent choice and waste minimization rather than replacing the analyte itself.

  • Prefer lower-toxicity calibration solvents when performance allows:
    • Methanol can substitute for acetonitrile in many LC applications; evaluate effects on ionization and peak shape.
    • For GC calibration, isooctane may present lower volatility and flammability risk versus hexane while offering similar chromatographic behavior.

Comparison (general considerations):

  • Acetonitrile vs Methanol (LC):
    • ACN: lower viscosity (reduced backpressure), often sharper peaks; higher toxicity and supply volatility.
    • MeOH: greener profile and cost-effective; may reduce MS response for some hydrophobic analytes and increase backpressure.
  • Hexane vs Isooctane (GC):
    • Hexane: very volatile, neurotoxicity concerns.
    • Isooctane: somewhat safer handling profile; slightly higher boiling point; often equivalent for pesticide standards.

Operational practices:

  • Prepare smaller aliquots to extend shelf life and avoid repeated thaw/warm cycles.
  • Consolidate multi-residue standards to decrease solvent use where validated.
  • Collect halogen-free organic waste separately for optimized disposal and potential solvent recycling.

Note: Any solvent change must be validated for accuracy, precision, and stability for your specific method.

Pharmaceutical Uses

Not applicable as a pharmaceutical excipient or formulation component. This product is supplied as an analytical standard for research and instrumentation calibration purposes only. No clinical or therapeutic use is intended or implied.

Physical Properties

Item-specific properties for this standard solution (concentration, solvent, density, refractive index, etc.): Not specified for this item; refer to CoA/Spec Sheet.

General physical information for the neat analyte iprobenfos (literature, for context only and not product specifications):

  • Typical physical state: oily liquid, hydrophobic; low volatility relative to light solvents.
  • Solubility profile: sparingly soluble in water; readily soluble in common organic solvents used for residue analysis (e.g., hexane, acetone, acetonitrile, methanol; exact values vary by source).
  • Partitioning: exhibits high lipophilicity typical of aryl organophosphorothioates (log Kow > 3, literature generalization; consult primary sources for exact values).
  • UV absorption: aromatic chromophore provides UV activity in the 200–280 nm region (literature, wavelength maxima depend on solvent and conditions).

Practical implications for users:

  • As an analytical standard solution, use the density/assay from the CoA to perform accurate mass- or volume-based dilutions.
  • Allow solution to equilibrate to room temperature before aliquoting to minimize volumetric error from thermal expansion (particularly for ACN or MeOH matrices).
Quality and Grades
  • Supplied grade: Analytical standard (as stated in Product Data).

What “Analytical standard” signifies:

  • Prepared and qualified for use in calibration, system suitability, spiking/recovery, and method validation in instrumental analysis (e.g., GC, LC, MS). Analytical standards emphasize identity and assay accuracy/traceability over synthetic reagent purity.
  • Typical controls (general): gravimetric preparation, purity assessment of the neat analyte, and quantitative assay of solution concentration by validated methods. Exact uncertainties, traceability chain (e.g., NMI or internal) and matrix are product-specific and should be taken from the CoA.

Implications for this item:

  • Concentration, solvent matrix, and uncertainty: Not specified for this item; refer to CoA/Spec Sheet.
  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Storage per Product Data: Room temperature; shipped under normal conditions.

Best practices:

  • Use class-A volumetrics or gravimetric dilution to prepare working standards.
  • Record lot number and expiry/retrospective requalification dates from the label/CoA.
  • For LC-UV/LC-MS work, confirm baseline cleanliness of the solvent matrix if background absorbance or ion suppression is a concern.
Reaction and Applications

This product is intended as an analytical reference solution. Synthetic reaction use is not typical. Key application domains include:

  • Pesticide residue analysis:
    • Calibration and quantitation of iprobenfos in agricultural commodities, environmental waters, and soils by GC (e.g., GC–MS, GC–NPD/FPD) or LC–MS/MS.
    • Spike-recovery experiments in QuEChERS methods (AOAC/EN variants) and other extraction/cleanup workflows (d-SPE, SPE cartridges such as PSA/C18/graphitized carbon).
  • Method validation:
    • Establish LOD/LOQ, linearity, accuracy, precision, and matrix effects for iprobenfos using multi-point calibration curves.
    • Stability studies of iprobenfos under sample preparation conditions (e.g., effect of pH, light, and cleanup sorbents).
  • Environmental fate studies (analytical):
    • Monitor degradation and metabolite formation during hydrolysis or photolysis experiments; track parent analyte decay by validated analytical methods.

Practical tips:

  • For GC: consider nonpolar columns (e.g., 5% phenyl–95% dimethylpolysiloxane). Use splitless injections for sensitivity; verify absence of active sites with liner deactivation.
  • For LC–MS/MS: develop MRM transitions specific to iprobenfos and confirm with qualifier ions; optimize source temperature and desolvation to accommodate moderately nonpolar analyte.
  • Use internal standards (isotopically labeled if available) to correct for matrix effects and variability.
Reaction Conditions

As an analytical standard, typical “reaction conditions” are replaced by instrumental analysis conditions. The following guidance is general (literature/practice) and must be validated in-house; these are not product specifications.

  • GC methods:

    • Columns: low-to-mid polarity columns (5% phenyl–95% PDMS, 30 m × 0.25 mm × 0.25 µm) provide good separation in multi-residue screens.
    • Injection: splitless 1–2 µL; inlet at 250–280 °C with deactivated liners to minimize adsorption.
    • Detection: MS (EI, SIM/scan), NPD, or P/S-selective FPD.
    • Oven program example (general): initial 70–80 °C hold, ramp 10–20 °C/min to 280–300 °C; exact program depends on matrix and co-eluting analytes.
  • LC–MS/MS methods:

    • Mobile phases: water with volatile buffer (e.g., 0.1% formic acid or 5 mM ammonium formate) and acetonitrile or methanol organic phase.
    • Columns: C18 or phenyl-hexyl, 100–150 mm length for multi-residue separations.
    • Ionization: ESI or APCI; evaluate both, as moderately nonpolar organophosphorothioates may favor APCI in some systems.
    • Quantitation: use multiple reaction monitoring (MRM) with qualifier/quantifier transitions and ion ratio criteria.
  • Stability during prep:

    • Maintain neutral to slightly acidic conditions during extraction to reduce base-catalyzed hydrolysis.
    • Minimize exposure to intense light and elevated temperature; use amber vials.

Refer to your CoA for concentration and to the SDS for solvent-specific handling during instrument setup.

Safety and Handling

Item-specific hazard classification (GHS signal word, H/P statements, pictograms) and solvent-specific hazards: Not specified for this item; refer to the product SDS.

General safety considerations (literature/background; not a substitute for SDS):

  • Iprobenfos is an organophosphorus fungicide. While not designed as a cholinesterase inhibitor like certain OP insecticides, organophosphorus compounds warrant caution to avoid exposure.
  • Potential hazards include eye/skin irritation and toxicity if swallowed or inhaled for the neat substance or concentrated solutions; the actual risk profile depends on the diluent and concentration in this standard.

Handling and PPE:

  • Work in a fume hood; avoid inhalation and skin contact.
  • Wear appropriate PPE: lab coat, safety glasses, and chemical-resistant gloves (e.g., nitrile). For large-scale handling or aerosol risk, consider a face shield and respiratory protection per institutional policy.

Incompatibilities and stability (general):

  • Avoid strong oxidizers and strong bases/acids that may catalyze hydrolysis or decomposition of organophosphorothioates.
  • Prevent prolonged exposure to light and elevated temperatures.

First aid (overview; defer to SDS for specifics):

  • Skin/eye contact: Rinse with water for ≥15 minutes; remove contaminated clothing.
  • Inhalation: Move to fresh air; seek medical attention if symptoms persist.
  • Ingestion: Rinse mouth; seek medical attention. Do not induce vomiting unless directed by medical personnel.

Waste: Treat as pesticide-containing chemical waste/organic solvent waste per local regulations.

Solvent Selection

Product-specific solvent matrix: Not specified for this item; refer to CoA/Spec Sheet.

General guidance for iprobenfos analytical work (literature/practice):

  • Polarity: nonpolar to moderately polar analyte (aryl organophosphorothioate), compatible with non-aqueous organic solvents.
  • Common standard matrices: acetonitrile or methanol for LC workflows; isooctane or hexane for GC workflows. Mixed solvents (e.g., ACN:toluene) are also used to balance solubility with volatility.
  • Sample preparation compatibility: QuEChERS extracts (ACN-based) and nonpolar solvent partitions are typical for pesticide residues.

Choosing among solvents:

  • GC-EI/FPD/NPD workflows: isooctane/hexane provide volatility and injection compatibility; avoid high polarity diluents that broaden peaks in splitless injections.
  • LC-UV/LC–MS/MS: acetonitrile or methanol are preferred; ensure miscibility with the initial mobile phase to avoid peak distortion.
  • Stability: organophosphorothioates are generally stable in dry aprotic solvents; avoid prolonged storage in aqueous/basic media that can promote hydrolysis.

Tip: Match the calibration solvent to the sample extract matrix and initial mobile phase (or GC solvent) to minimize matrix/solvent effects on response and peak shape.

Storage and Reconstitution
  • Storage conditions (from Product Data): Room temperature. Protect from light; store tightly closed to minimize solvent loss. Use secondary containment to reduce evaporative exposure.
  • Shipping: Normal conditions (per Product Data).
  • Reconstitution: Not applicable; supplied as a ready-to-use standard solution. If concentration adjustment is required, dilute with a solvent compatible with your analytical method (e.g., acetonitrile, methanol, isooctane/hexane), using gravimetric preparation where possible.
  • Handling practices:
    • Upon receipt, record lot number and any stated expiry date. If long-term use is planned, subdivide into single-use amber aliquots to avoid repeated opening.
    • Allow to equilibrate to room temperature before opening to prevent condensation and concentration drift.
    • Avoid contact with strong bases or aqueous alkaline media that may promote hydrolysis of organophosphorothioates.
  • Stability and concentration: Not specified for this item; refer to CoA/Spec Sheet for assigned concentration, uncertainty, and expiry/retetesting guidance.
Structure and Identity

Analytical reference solution of the organophosphorus fungicide iprobenfos (IBP), intended for calibration/quantitation in residue and environmental methods.

  • Item-specific identifiers (this product):

    • CAS: 26087-47-8
    • PubChem CID: 33294 (literature identifier for iprobenfos)
    • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
    • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
  • Structural features (literature, describing the neat analyte iprobenfos):

    • Organophosphorothioate ester bearing a benzylthio substituent on phosphorus and two isopropoxy groups (O,O-diisopropyl S-benzyl phosphorothioate motif).
    • Key functional groups: P=S (thiono), P–S–CH2–Ph (benzylthio), two P–O–iPr ester linkages, aromatic phenyl ring.
    • 2D description: A tetra-coordinated phosphorus center double-bonded to sulfur (P=S), singly bonded to sulfur that connects to a benzyl phenyl ring, and singly bonded to two isopropoxy groups; no defined stereocenters.

Notes: The product is supplied as a standard solution; exact diluent/assayed concentration are not specified here. Consult the accompanying Certificate of Analysis (CoA) for solution identity and concentration details.

Synthetic Utility

This product is provided as a ready-to-use analytical standard solution rather than a synthetic reagent. Consequently, it is not typically used as a building block or catalyst in preparative chemistry.

Contextual (literature) reactivity of the neat analyte iprobenfos:

  • Functional groups: thiono-phosphorus (P=S), thioether linkage to benzyl, and two isopropoxy esters at phosphorus.
  • Transformations: susceptible to hydrolysis (acid/base-catalyzed) and oxidative desulfuration (P=S to P=O) under strong oxidizing conditions; the P–S–benzyl bond can cleave to yield benzyl sulfur species and dialkyl phosphate derivatives.

Analytical chemistry utility:

  • Serves as the target analyte for validating extraction/cleanup chemistries (e.g., recovery across PSA/C18/GCB sorbents) and instrumental response in multi-residue methods.
  • Can be used to assess degradation under forced conditions to profile stability indicating methods (parent vs degradants).
Target Specificity

Not applicable. This product is a small-molecule analytical standard (not an antibody, enzyme, or probe). No antigen/epitope specificity, clone, isotype, or species reactivity is relevant.

Domande frequenti

How should this product be stored?
Store at room temperature.
What does analytical standard mean?
analytical standard is a defined analytical purity tier suitable for quantitative analytical methods. It specifies a minimum assay percentage, controlled limits on common impurities (water, heavy metals, residue on ignition), and lot-to-lot consistency. analytical standard is one of several purity tiers — choose based on the sensitivity and regulatory requirements of your method.
How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 26087-47-8, the molecular formula is C13H21O3PS, and the molecular weight is 288.32 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Hai bisogno di aiuto per scegliere la qualità?

La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.

Visualizza la guida alle qualità Analytical standard →

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.