This compound belongs to the class of organic compounds known as naphthofurans. These are compounds containing a furan ring fused to a naphthalene moiety. Furan is a 5 membered- ring aromatic ring with four carbon and one oxygen atoms. Naphthalene is a polycyclic aromatic hydrocarbon made up of two fused benzene rings.
External Descriptors
Not available
1. Djoumbou Feunang Y, Eisner R, Knox C, Chepelev L, Hastings J, Owen G, Fahy E, Steinbeck C, Subramanian S, Bolton E, Greiner R, and Wishart DS. ClassyFire: Automated Chemical Classification With A Comprehensive, Computable Taxonomy. Journal of Cheminformatics, 2016, 8:61.
Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Proprietà chimiche e fisiche
Peso molecolare
272.34
XLogP3
2.700
Hydrogen Bond Donor Count
0
Hydrogen Bond Acceptor Count
3
Rotatable Bond Count
2
Exact Mass
272.141 Da
Monoisotopic Mass
272.141 Da
Topological Polar Surface Area
39.400 Ų
Heavy Atom Count
20
Formal Charge
0
Complexity
485.000
Isotope Atom Count
0
Defined Atom Stereocenter Count
5
Undefined Atom Stereocenter Count
0
Defined Bond Stereocenter Count
0
Undefined Bond Stereocenter Count
0
The total count of all stereochemical bonds
0
Covalently-Bonded Unit Count
1
Calcolatori di soluzioni
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Recensioni
Recensioni dei clienti
Application Protocols
No item-specific validated application protocols are provided. The following are general starting points for small-molecule handling in research settings (not item-specific):
Preparation of stock solutions:
Dissolve in a suitable organic solvent (e.g., DMSO, ethanol, or acetonitrile) to 10–100 mM depending on solubility. Filter (PTFE, 0.22 µm) if needed.
GC–MS reference standard:
Prepare ~0.1–1.0 mg/mL in hexane or isooctane. Use autosampler vials with low-adsorption inserts; minimize light exposure. Include internal standards for quantitation.
LC–MS reference standard:
0.01–0.1 mg/mL in acetonitrile or methanol; consider 0.1% formic acid for improved peak shape if compatible. Avoid high aqueous content to prevent precipitation.
Hydrolysis screen (analytical scale):
Dissolve in dry MeOH, add K2CO3 (0.5 equiv), stir at rt, monitor by TLC/GC–MS. Quench with sat. NH4Cl, extract with EtOAc, dry, and analyze.
These procedures are illustrative only. Optimize conditions to your specific instrumentation and experimental goals.
Biological Roles
Item-specific biological data are not provided. The following is general context for acetate esters of plant-derived terpenoids (literature-based, not item-specific):
Source and function: Many acetate esters in plants derive from acetylation of terpene alcohols by acetyltransferases. They can modulate volatility, membrane affinity, and storage stability of the parent alcohols.
Ecological roles: Terpenoid acetates often contribute to plant–insect and plant–microbe interactions as semiochemicals (attractants/repellents), and to defense or communication signals in essential oils and resins.
Metabolic fate: In organisms, esterases can hydrolyze acetate esters to liberate the corresponding alcohol and acetic acid. The alcohol may then undergo oxidation (to aldehydes/ketones/acids) or conjugation.
Physicochemical behavior in biochemistry: High hydrophobicity promotes partitioning into lipid membranes and hydrophobic protein pockets; specific binding events (if any) depend on exact stereochemistry and functionality.
Important limitations:
No claims are made regarding biological activity, safety in vivo, or therapeutic value. This product is for research use only.
For any bioassays, establish dose–response and cytotoxicity independently, and document vehicle controls due to the likely need for organic co-solvents.
Buffer Applications
Not typically applicable. Linderene acetate is a neutral, hydrophobic organic ester and is not used as a buffer component. It lacks acid/base functionality in the practical physiological pH range.
Practical guidance:
If incorporating into aqueous systems, use appropriate organic co-solvents (e.g., ethanol, DMSO at low % v/v) and add carefully to pre-made buffers with vigorous mixing to avoid precipitation.
For biological assays, confirm solvent tolerance of the system and maintain constant co-solvent percentages across controls and treatments.
Green Alternatives
Perspective: While Linderene acetate itself is a target analyte/reagent, greener choices matter primarily in solvent/reaction selection and in the route to and from the acetate functionality.
Greener solvent choices (literature-based, not item-specific):
Replace chlorinated solvents (DCM, chloroform) with ethyl acetate, cyclopentyl methyl ether (CPME), 2-methyltetrahydrofuran (2-MeTHF), or heptane when feasible.
Favor ethanol or isopropanol as benign media for enzymatic transesterifications or extractions.
Comparison (general):
DCM vs EtOAc: EtOAc is biodegradable, lower toxicity, and often adequate for extraction/purification, though DCM may provide better solubility and sharper separations in some cases.
Hexane vs Heptane: Heptane offers a safer profile (less volatile, often non-HAP) with similar nonpolarity.
Traditional bases (NaOMe) vs Organic superbases: Consider milder carbonate bases (K2CO3) in alcohols or enzymatic methods to reduce hazard and waste.
Process considerations:
Enzymatic deacetylation (lipases) can deliver the parent alcohol under mild, low-waste conditions compared with aqueous strong base/acid workups.
Solvent recycling and micro-scale reaction optimization minimize environmental footprint in analytical standard preparation.
Note: No item-specific green certification or solvent residual specifications are provided for this item; refer to CoA/Spec Sheet.
Pharmaceutical Uses
No item-specific pharmacopeial status or excipient designation is provided for this product. The following information is general and does not imply suitability for human or veterinary use.
General context (not item-specific):
Terpenoid acetates are sometimes explored in pre-formulation research as model hydrophobic esters to study solubilization, volatility, and partitioning in lipid-based delivery systems. However, this product is designated strictly for research use only.
Formulation research tools: Can serve as hydrophobic probe molecules to evaluate emulsification capacity of surfactants, cyclodextrin inclusion potential, or polymer–ester interactions in film-forming studies.
Caveats:
Do not use in drug products, clinical applications, or as a food/cosmetic ingredient. No GMP, USP/NF, or compendial compliance is claimed here.
For regulatory or translational work, source materials with explicit pharmacopeial grades and full impurity/toxicology documentation.
Physical Properties
Item-specific measured specifications (if any):
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Melting point (MP): Not specified for this item; refer to CoA/Spec Sheet.
Boiling point (BP): Not specified for this item; refer to CoA/Spec Sheet.
Density: Not specified for this item; refer to CoA/Spec Sheet.
Refractive index: Not specified for this item; refer to CoA/Spec Sheet.
Solubility: Not specified for this item; refer to CoA/Spec Sheet.
General/literature context for acetate esters of terpenoids (not item-specific):
Physical state: typically colorless to pale liquids or low-melting solids with hydrophobic character.
Solubility: generally soluble in nonpolar/aprotic organic solvents (e.g., hexanes, toluene, DCM, EtOAc) and sparingly soluble to insoluble in water.
LogP: often high (logP > 3) for sesquiterpene acetates; exact value for this compound is not established here.
Volatility: depending on carbon count and branching, terpenoid acetates can be moderately volatile and aroma-active.
Analytical tips (general):
GC–MS suitability: Many acetate esters are amenable to GC–MS if thermally stable; use split/splitless injection and nonpolar to mid-polar columns (e.g., 5% phenyl, wax for ester confirmation). Verify stability prior to high-temperature methods.
LC–MS: ESI often gives [M+Na]+ or [M+NH4]+ in positive mode; APCI may enhance ionization for nonpolar esters.
Quality and Grades
Item-specific information:
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Interpretation and guidance (general):
When purity is not listed, consult the CoA for assay (e.g., GC, HPLC), peak area normalization, and impurity profile. For terpenoid acetates, common impurities may include the parent alcohol, isomeric acetates, residual solvents, and oxidation byproducts.
If “analytical standard” or “reference material” is indicated on the CoA, expect tighter control on identity (NMR/GC–MS trace) and lower UV-absorbing impurities for chromatographic work.
UV cutoffs, water content, and stabilizers: Not specified for this item; refer to CoA/Spec Sheet. If a stabilizer is used (e.g., small amounts of BHT for autoxidation-prone materials), confirm its presence on the CoA and consider its impact on downstream assays.
Batch-to-batch consistency: For natural-product derivatives, stereochemical/isomeric purity can influence physical properties and chromatographic behavior; review chiral GC/LC data if provided.
Recommended acceptance criteria (user-defined, example framework):
Identity confirmation by 1H/13C NMR and MS.
Purity ≥95% by GC or HPLC for general synthesis; ≥98% for analytical uses; define and justify as appropriate for your application.
Reaction and Applications
Manufacturer Applications: Not specified beyond “For research use only.” The following expands on typical research uses for acetate esters of natural-product scaffolds (general guidance, not item-specific):
Analytical and standards work:
Use as a reference compound in GC–MS/LC–MS metabolomics, essential-oil profiling, and dereplication workflows to aid identification of plant metabolites.
Calibration: Prepare multilevel calibration curves in nonpolar solvents; evaluate stability under autosampler conditions and avoid prolonged exposure to strong light.
Chemical transformations (typical for acetate esters):
Hydrolysis (saponification): Base-catalyzed (e.g., K2CO3/MeOH, NaOMe/MeOH) to regenerate the parent alcohol (e.g., “linderene” alcohol) for structure–activity studies.
Transesterification: Acid or base catalysis to exchange the acetate for other acyl groups; enzymatic acylation/deacylation for mild, selective transformations.
Oxidation/Reduction: If the scaffold contains alkenes (common in terpenoids), epoxidation (mCPBA), dihydroxylation (OsO4/NMO), or hydrogenation (Pd/C, H2) can be explored; keep acetate stability in mind.
Material/olfactory science research:
Terpenoid acetates are widely evaluated for volatility, partitioning, and sensory attributes in aroma chemistry research; conduct such studies under IRB/ethical and institutional safety frameworks—no consumer use is implied.
Practical tips:
Maintain anhydrous conditions for base-catalyzed steps to minimize side hydrolysis.
Monitor reactions by TLC (anisaldehyde, vanillin stains are effective for terpenoids) and GC–MS.
Reaction Conditions
The following conditions are general literature guidance for acetate esters and terpenoid-like substrates; they are not item-specific specifications.
Base-catalyzed hydrolysis (saponification):
Typical: K2CO3 (0.5–1.5 equiv) in MeOH, rt to 40 °C, 1–6 h. Quench with water, extract into EtOAc/hexanes. Alternative: NaOMe (0.1–0.5 equiv) in MeOH, 0–25 °C, 10–60 min for faster, but monitor closely to avoid side reactions.
Acid-catalyzed hydrolysis:
Typical: Aqueous AcOH or dilute HCl in MeOH/H2O (70:30), rt to reflux, 1–12 h. Terpenoid backbones can isomerize under strong acid—use mild conditions.
Enzymatic deacetylation:
Lipase (e.g., CAL-B) in buffer/organic biphasic or solvent-free systems at 25–40 °C; hours to overnight. Often high chemoselectivity and milder conditions.
Transesterification:
Base-catalyzed in anhydrous alcohol (ROH) with catalytic NaOMe/KOtBu, rt to reflux; or enzyme-catalyzed using vinyl esters as acyl donors to drive equilibrium.
Hydrogenation of olefins (if present):
Pd/C (5–10 wt%), H2 (1–3 atm), EtOAc/EtOH/hexane, 20–30 °C, 2–12 h. Ensure acetate stability and monitor.
Epoxidation of alkenes (if present):
mCPBA (1.1–1.5 equiv) in DCM at 0–25 °C, 0.5–3 h. Buffer workup (NaHCO3) to minimize acetate cleavage.
Monitoring & workup:
TLC with anisaldehyde or vanillin stains is effective for terpenoids. GC–MS/LC–MS for confirmatory analysis. Neutral, oxygen-free conditions and amber glassware help preserve integrity during reactions and storage.
Safety and Handling
Authoritative safety information must be taken from the product’s SDS.
Product Data (item-specific):
GHS classification: Not specified for this item; refer to SDS.
Signal word, H-statements, pictograms: Not specified for this item; refer to SDS.
Storage: Store at 2–8 °C, protected from light. Shipped on wet ice.
General handling guidance for organic acetate esters and hydrophobic natural-product derivatives (not item-specific):
PPE: Use lab coat, safety glasses/goggles, and appropriate chemically resistant gloves (e.g., nitrile). Work in a fume hood to control vapors and avoid inhalation exposure.
Incompatibilities: Avoid strong acids or bases (risk of hydrolysis/transesterification), strong oxidizers (possible oxidation at unsaturation), and prolonged light/air exposure (potential autoxidation for unsaturated terpenoids).
Spill/cleanup: Absorb with inert material (vermiculite, sand), collect for disposal as organic waste. Ventilate area.
First aid (general): If inhaled, move to fresh air; if on skin, wash with soap and water; if in eyes, rinse cautiously with water for several minutes; if ingested, rinse mouth—seek medical attention in all cases as appropriate per SDS.
Fire safety: Many acetate esters are flammable liquids; keep away from ignition sources and use CO2, dry chemical, or foam extinguishers.
Always defer to the specific SDS for classification, exposure limits, and disposal regulations.
Solvent Selection
Applicability: Linderene acetate is expected to be a neutral, hydrophobic organic ester. Solvent choice should reflect its nonpolar to moderately nonpolar character.
General solvent behavior (literature-based, not item-specific):
Miscibility/solubility: Good in nonpolar and moderately polar aprotics (hexanes, toluene, diethyl ether, MTBE, CPME, DCM, chloroform, ethyl acetate). Poor in water and highly polar protics unless co-solvents are used.
Polarity class: Low to medium polarity (typical of terpene acetates). Dielectric constants of likely solvents: hexane (~1.9), toluene (~2.4), DCM (~9.1), EtOAc (~6.0) (literature).
When to choose which solvent (practical):
Purification: Normal-phase silica with hexane/EtOAc or hexane/MTBE gradients often provide good resolution of terpene acetates from alcohols and hydrocarbons.
Spectroscopy: CDCl3 or C6D6 are common NMR solvents for nonpolar esters; verify solubility.
Reaction media: For hydrolysis or transesterification screens, use anhydrous alcohols (MeOH, EtOH, i-PrOH) with catalytic acid/base, or biphasic aqueous/organic systems for enzymatic methods.
Comparison notes:
DCM vs. EtOAc: DCM offers stronger elution and broad solubility but higher environmental burden; EtOAc is greener but may hydrolyze/base-saponify sensitive esters under basic conditions.
Hexanes vs. heptane: Heptane is often preferred for reduced volatility and improved safety without sacrificing nonpolarity.
Storage and Reconstitution
Item-specific storage and logistics (from Product Data):
Storage conditions: Store at 2–8 °C, protected from light.
Shipped in: Wet ice.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
General stability guidance for acetate esters and terpenoid-like molecules (not item-specific):
Protect from light and air to minimize oxidation or isomerization (if unsaturation is present). Use amber vials with PTFE-lined caps; consider inert gas backfill (N2/Ar) after opening.
Avoid repeated freeze–thaw of concentrated solutions. Prepare single-use aliquots in suitable solvents (e.g., hexane, EtOAc, DCM, or ethanol) and store at 2–8 °C if stable; for longer-term storage, evaluate −20 °C in the dark.
Moisture control: Keep containers tightly closed; esters can hydrolyze slowly in the presence of moisture and acids/bases.
Reconstitution/solution preparation (guidance):
Bring vial to room temperature before opening to avoid condensation. Dissolve in a compatible anhydrous solvent to the desired concentration. If using in aqueous systems, add as a concentrated solution to the aqueous phase with vigorous mixing.
Compliance note:
For research use only. Refer to the product’s CoA and SDS for any item-specific stability, concentration limits, or incompatibilities.
Structure and Identity
Brief overview: Linderene acetate is cataloged as a small-molecule natural-product derivative (presumed terpene/terpenoid acetate ester) offered for research use.
Item-specific identifiers (from Product Data):
SKU: L648823
Product name: Linderene acetate
CAS: 26146-28-1
PubChem CID: 497204
InChIKey: 137323 (as provided)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Structural features (general/literature context, not item-specific):
The name “acetate” indicates an ester functional group (–O–C(=O)CH3) appended to an alcohol precursor (“linderene”).
Typical acetate esters derived from terpenoids are neutral, hydrophobic molecules, often containing isoprenoid carbon skeletons with possible alkene(s) and a secondary or tertiary acetate.
Expected 2D description (literature-style, generic): a hydrocarbon backbone (likely C10–C15 if terpenoid) bearing an alkoxy acetate moiety; potential ring(s) or isoprenyl branching may be present depending on the linderene scaffold.
Notes:
Any definitive atom connectivity, stereochemistry, ring count, and unsaturation pattern are Not specified for this item; refer to CoA/Spec Sheet.
For authoritative structure confirmation, consult the supplied CoA/SDS and acquire orthogonal data (e.g., 1H/13C NMR, HRMS, IR, and, if needed, GC/MS or LC–MS).
Synthetic Utility
Framework (general, not item-specific): Linderene acetate, as an acetate ester of a terpene-like alcohol, is a versatile handle in synthesis and analysis.
Key functional group reactivity:
Ester hydrolysis: Access to the corresponding alcohol allows further derivatization (oxidation to aldehyde/ketone, Mitsunobu reactions, carbon–carbon bond formations via activation as halides or sulfonates).
Acyl exchange: Transesterification enables isotopic or structural labeling (e.g., 13C-acetate), and installation of alternative acyl groups to probe steric/electronic effects.
Protecting group role: The acetate can act as a temporary protecting group for an allylic/secondary alcohol in multistep sequences, removable under mild basic or enzymatic conditions.
If the scaffold is terpenoid (typical for “linderene” derivatives):
Alkene manipulations (where present): epoxidation, hydroboration–oxidation, ozonolysis/oxidative cleavage to map double-bond positions or create fragment libraries.
Stereochemical studies: Chiral derivatization or chiral GC can resolve enantiomeric purity of the parent alcohol after deacetylation.
Analytical transformation:
Preparing trimethylsilyl (TMS) ethers of the deacetylated alcohol can enhance GC volatility and stability for structure confirmation.
Note: Specific reactivity depends on the actual substitution pattern; consult spectral data and small-scale trials.
Target Specificity
Not applicable. This product is a small organic molecule and not a biological affinity reagent. No antigen/epitope/clone/isotype information applies.
Item-specific note: No target-binding or selectivity data are provided for this item. Any interaction studies should be designed de novo with appropriate controls.
Domande frequenti
What is the purity of this product?
This product is supplied at ≥99% purity (chemical assay). Lot-specific values are stated on the Certificate of Analysis.
How should this product be stored?
Store at 2–8 °C, protected from light. The material is light-sensitive — keep it in its original opaque or amber container.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 26146-28-1, the molecular formula is C17H20O3, and the molecular weight is 272.34 g/mol. InChIKey ICLTVELXFUIGLS-FBHBFLDISA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Utilizziamo i cookie per garantire il corretto funzionamento del sito web e, ove consentito, per migliorare la tua esperienza. Puoi gestire le tue preferenze in qualsiasi momento nelle Impostazioni. Per saperne di più, consulta la nostra Cookie Policy.
Desidera che le inviamo un messaggio quando avremo sconti disponibili?
Ricordamelo più tardi
Grazie! Controlli la sua casella di posta per confermare.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.