Malate Synthase Activity Assay Kit (Colorimetric Method)

Cat. No.: M1522253
Disponibile su ordine
QUALITÀ & PUREZZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
24T
M1522253-24T
Su ordinazione · 8–12 settimane
338,33€
Enter a quantity for the sizes you want to add.

Panoramica

Malate synthase (MS, EC 2.3.3.9) is a key enzyme of the glyoxylate cycle and is found in bacteria, fungi, protozoa, and germinating plant seeds. Malate synthase catalyzes the reaction of acetyl-CoA and glyoxylate to produce malate and CoA. The generated CoA is reducing and reacts with DTNB to form a yellow product, which has a characteristic absorption peak at 412 nm. MS enzyme activity is determined based on this reaction. Reaction: acetyl-CoA + glyoxylate + H₂O → (S)-malate + CoA

Specifiche

Specifiche e purezza
BioReagent
Grado
BioReagent
Applicazione
Enzyme activity assay
Metodo di rilevamento
Colorimetric Method
Detection instrument
Visible Spectrophotometer
Detection wavelength
412nm
Stoccaggio e spedizione
Condizioni di conservazione di stoccaggio
Store at 2-8°C,Protected from light
Spedito in
Wet ice
Stabilità e conservazione
Store at 2-8℃ for 3 months. Store in the dark.

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Application Protocols

Only a high-level workflow is provided here; follow the kit’s official protocol for reagent preparation, incubation times, and calculations.

General workflow (not item-specific):

  1. Equilibrate all components to assay temperature; protect light-sensitive reagents.
  2. Prepare working solutions of substrates and colorimetric reagent as directed; include blanks and standards/controls if provided.
  3. Prepare samples (e.g., clarified lysates) on ice; determine protein concentration for normalization if required.
  4. Dispense samples and controls into a microplate or cuvette; initiate reaction by adding the last component (e.g., substrate mix).
  5. Monitor absorbance at the specified wavelength at defined intervals or as an endpoint within the linear range.
  6. Calculate activity using ΔA/min, extinction coefficient/pathlength (if applicable), and sample dilution; report as mU/mL or mU/mg protein as appropriate.
  • Recommended dilutions, positive controls, and exact wavelengths: Not specified for this item; refer to kit manual/CoA.
  • Instrumentation: Standard visible-range microplate reader or spectrophotometer compatible with the assay wavelength.
Biological Roles

Malate synthase (MS) is a key enzyme of the glyoxylate cycle, an anaplerotic pathway that enables assimilation of two-carbon compounds without carbon loss via decarboxylation.

General biology (literature):

  • Reaction: Glyoxylate + Acetyl‑CoA + H2O → L‑Malate + CoA‑SH (catalyzed by malate synthase).
  • Pathway context: Operates with isocitrate lyase to bypass the CO2‑releasing steps of the TCA cycle, replenishing malate and oxaloacetate pools.
  • Distribution: Prominent in bacteria, fungi, and plants (glyoxysomes), typically absent in adult mammalian central metabolism but reported in specific contexts or organisms; assay utility spans microbial physiology and plant biochemistry.
  • Functional relevance: Supports growth on acetate, fatty acids, or ethanol as sole carbon sources; influences persistence and metabolic flexibility in microorganisms.

Assay implications:

  • Activity measurements inform carbon flux through the glyoxylate shunt and can validate genetic manipulations, culture conditions, or inhibitor action.
  • Kinetic profiling can reveal isoform differences (e.g., MS-A vs MS-B in some bacteria, literature) and temperature/pH optima.

Note: These roles are provided for biochemical context and are not claims about clinical utility. Use this kit strictly for laboratory research as indicated.

Buffer Applications

Not primarily applicable. This product is a colorimetric enzyme activity kit with its own recommended assay buffer system. Use the buffers supplied or specified in the kit manual for optimal performance.

General notes (literature):

  • Common buffers for malate synthase assays include Tris, HEPES, or phosphate at neutral to slightly basic pH (e.g., 7.0–8.0), with ionic strength and any cofactors/additives adjusted to stabilize the enzyme while minimizing interference with the chromogenic reaction.
Green Alternatives

While this is an assay kit rather than a bulk solvent or reagent, greener laboratory practices can reduce environmental impact.

  • Micro-scale workflows: Use microplate formats (96- or 384-well) to minimize reagent consumption and waste.
  • Solvent minimization: If inhibitors require solubilization, keep DMSO or other organic cosolvents at the lowest functional percentage; avoid chlorinated solvents entirely for assay make-up.
  • Hazard reduction (general): If the colorimetric chemistry uses thiol-reactive reagents such as DTNB (literature), handle and dispose of solutions as hazardous chemical waste and avoid unnecessary excess.
  • Packaging: Consolidate shipments and store properly (2–8 °C, protected from light) to reduce losses and repeat orders.

Illustrative comparison (general, not item-specific):

  • DTNB-based thiol detection (literature): convenient, simple, visible readout (~412 nm), but generates thiolate waste and can be inhibited by reducing agents.
  • Alternative coupling chemistries (literature): NADH-linked or enzymatic cascade readouts can avoid direct thiol reagents but may increase complexity and reagent count. Trade-offs include sensitivity, interference profiles, and stability.
Pharmaceutical Uses

This kit is for laboratory research use only and is not intended for diagnostic, therapeutic, or GMP manufacturing purposes.

General research/development context (not item-specific):

  • Early discovery: Enzyme activity assays can support target validation and preliminary inhibitor screening campaigns for microbial metabolic targets.
  • Formulation/excipient relevance: Not applicable—this is not a formulation excipient and has no pharmacopeial monograph as a kit.

Any regulatory or clinical use is outside the scope of this product’s intended application.

Physical Properties

As a multi-reagent assay kit, bulk physical properties (BP, MP, density) are not applicable.

  • Item-specific facts (from Product Data):
    • Storage: 2–8 °C, protected from light; shipped on wet ice.
  • Component-level specifications (solubility, pH, extinction coefficients, refractive index): Not specified for this item; refer to CoA/Spec Sheet.

Literature/general values relevant to colorimetric malate synthase assays (not item-specific):

  • Reaction monitored by formation of a chromophore when free CoA‑SH is produced or via coupling to a reporter system. A common colorimetric thiol detection uses Ellman’s reagent (DTNB) with an absorbance maximum at ~412 nm (literature), though individual kit chemistries may differ.
  • Typical assay buffer pH for malate synthase activity measurements falls in the neutral to slightly basic range (e.g., pH 7.0–8.0, literature) to support enzyme activity and substrate stability.
  • Temperature: Activity often measured at 25–37 °C depending on organismal source and experimental design (literature).
Quality and Grades
  • Item-specific grade: BioReagent (from Product Data).
    • BioReagent grade indicates components suitable for laboratory biochemical workflows, enzyme assays, and general research use, with attention to background signal and functional performance rather than clinical or GMP use.
  • What this means in practice:
    • Low background in colorimetric detection when used as directed.
    • Reagents and buffers selected to maintain enzyme integrity and minimize interfering contaminants.
  • Purity and stabilizers: Not specified for this item; refer to CoA/Spec Sheet and kit manual for any preservatives, enzyme standards, or stabilizers.
  • QC considerations for enzyme activity kits (general):
    • Functional verification of the colorimetric response under defined assay conditions.
    • Lot-to-lot consistency of blank and positive-control signals (where applicable).
  • Documentation: For detailed acceptance criteria (e.g., expected absorbance windows for controls), consult the kit’s Certificate of Analysis (CoA) or specification sheet.
Reaction and Applications

This kit enables quantitative measurement of malate synthase (MS) activity in biological samples.

  • Item-specific intent: Colorimetric detection of malate synthase activity for research use only (from Product Data).

Common applications (general, not item-specific):

  • Enzyme kinetics: Determine initial rates, Km, and Vmax for malate synthase from bacterial, plant, or recombinant sources.
  • Pathway studies: Probe the glyoxylate shunt activity in microorganisms and plants; evaluate metabolic reprogramming during carbon source shifts.
  • Screening: Assess small-molecule modulators or genetic perturbations impacting MS activity; include vehicle/blank controls to control for background absorbance.
  • Sample types: Clarified cell or tissue lysates, purified enzyme preparations, or culture supernatants when applicable (optimize lysis to avoid thiol-reactive carryover).

Practical tips (general):

  • Maintain samples and reagents on ice prior to assay to preserve activity; equilibrate to measurement temperature immediately before starting the reaction.
  • Prepare fresh working solutions of substrates and chromogenic reagents; use matched pathlength or microplate format to ensure linear absorbance readings.
  • Include no-enzyme and no-substrate controls to correct for non-enzymatic background and sample matrix absorbance.
  • Verify that reducing agents (e.g., DTT, βME) and high concentrations of detergents do not interfere with color development (literature).
Reaction Conditions

Item-specific, validated reaction conditions are provided in the kit manual. The following are general, literature-based guidelines for malate synthase colorimetric assays and are not specific to this item:

  • Temperature: 25–37 °C, chosen to reflect the source organism or experimental design.
  • pH: Neutral to slightly basic (e.g., pH 7.2–8.0) to balance enzyme activity and chromophore stability.
  • Ionic strength: Moderate salt (e.g., 50–150 mM) commonly used to maintain protein stability without suppressing activity (literature).
  • Substrates: Acetyl‑CoA and glyoxylate at saturating or titrated concentrations to determine kinetics; handle glyoxylate carefully due to hydrate/oxidation equilibria (literature).
  • Detection chemistry: A frequent colorimetric approach measures free CoA‑SH with a thiol-reactive chromogen such as DTNB at ~412 nm (literature). Alternative coupled systems may measure NADH consumption/formation at 340 nm.
  • Controls: Include blanks lacking enzyme, and matrix controls (e.g., heat-inactivated lysate). Run a positive control enzyme if available to verify assay performance.
  • Linearity: Optimize sample dilution and reaction time so that ΔA/t is linear and within the dynamic range of the plate reader.

Always follow the specific plate layout, incubation times, and calculation formulas provided in the kit insert for this item.

Safety and Handling
  • GHS classification, signal word, pictograms, and H-statements: Not specified for this item; refer to the product SDS for authoritative safety information.
  • General PPE: Wear lab coat, safety glasses, and appropriate chemically resistant gloves. Work in a well-ventilated area or fume hood when handling concentrated reagents.
  • Light sensitivity: Store protected from light as specified; minimize light exposure during use if chromogenic reagents are present.
  • Incompatibilities (general): Avoid mixing kit reagents with strong oxidizers or reductants unless directed by the protocol. If DTNB or other thiol-reactive agents are present (literature), avoid contamination with free thiols (e.g., DTT, βME) outside of intended assay steps.
  • Spill/first aid (overview): For small liquid spills, absorb with inert material and dispose of per institutional chemical waste procedures. In case of skin or eye contact, rinse with water for at least 15 minutes; seek medical advice. If inhaled or ingested, follow institutional emergency guidance and consult SDS.
  • Waste: Collect used assay mixtures and rinse solutions as chemical waste. Do not discharge to drain unless permitted by local regulations.
  • Note: Always defer to the item’s SDS and the kit insert/manual for reagent-specific hazards and handling instructions.
Solvent Selection

Not typically applicable. This product is an aqueous biochemical assay kit. Follow the kit protocol for buffer preparation and any recommended organic solvents (if any).

General guidance (literature/general):

  • Malate synthase assays are usually performed in aqueous buffers (e.g., Tris, HEPES, phosphate) with defined salt and cofactor compositions. Organic cosolvents should be minimized to protect enzyme activity; if testing inhibitor solubility, keep DMSO ≤1–2% v/v where compatible (literature) and include vehicle controls.
Storage and Reconstitution
  • Item-specific storage: Store the kit at 2–8 °C, protected from light (from Product Data). Shipped on wet ice.
  • Stability and shelf life: Not specified for this item; refer to CoA/Spec Sheet and kit insert for expiration and post-opening stability.
  • Reconstitution details: Not specified for this item; refer to the kit manual for reconstitution of any lyophilized components, recommended diluents, and working solution stability.

General handling guidance for assay kits (not item-specific):

  • Bring refrigerated components to working temperature just before use; keep enzymes and labile reagents on ice during setup.
  • Avoid repeated freeze–thaw cycles of any protein standards; aliquot upon first reconstitution if directions permit.
  • Protect chromogenic reagents from light; prepare fresh working solutions and discard remaining mixes after use unless the manual states a validated storage period.
  • Record lot numbers and preparation times to support traceability and reproducibility.
Structure and Identity

This product is an analytical assay kit, not a single defined molecule. It contains multiple components formulated to quantify malate synthase enzyme activity by a colorimetric readout.

  • Item-specific facts (from Product Data):
    • SKU: M1522253
    • Product: Malate Synthase Activity Assay Kit (Colorimetric Method)
    • Grade: BioReagent
    • Category: Life Science research use; For research use only
  • Chemical identifiers (molecular formula, MW, SMILES, InChIKey): Not applicable to a multi-component kit; not specified for this item; refer to CoA/Spec Sheet.
  • Structural features: The assay targets the enzymatic conversion catalyzed by malate synthase; the kit typically includes buffers, substrates, and a chromogenic detection reagent. Specific component identities are not specified for this item; refer to CoA/Spec Sheet.
  • Enzymatic target (general knowledge): Malate synthase catalyzes the condensation of glyoxylate with acetyl‑CoA to form L‑malate and CoA‑SH within the glyoxylate cycle (no net carbon loss).
Synthetic Utility

Not applicable. This product is a biochemical assay kit and is not used as a synthetic building block or reagent in organic synthesis.

For users interested in metabolic biochemistry instead of chemical synthesis:

  • Consider how malate synthase activity measurements integrate with metabolomics or fluxomics experiments to contextualize carbon routing through the glyoxylate cycle.
Target Specificity

Assay kits do not have antibody-like specificity parameters (e.g., clone, isotype). This product functionally measures the catalytic activity of the enzyme malate synthase in samples.

  • Item-specific details provided: None beyond the product name; refer to the kit manual for any notes on species compatibility, isoform coverage, or known interferences.
  • If the kit includes a positive control enzyme or standards, specificity and cross-reactivity information will be described in the product insert (not specified for this item; refer to CoA/Spec Sheet).

Domande frequenti

What does BioReagent mean?
BioReagent indicates that the product has been processed and tested for biological and biochemical applications. Specifications may include endotoxin limits, microbial controls, sterility, low DNase/RNase/protease activity, and verified biological activity where relevant.
How should this product be stored?
Store at 2–8 °C, protected from light. The material is light-sensitive — keep it in its original opaque or amber container.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Hai bisogno di aiuto per scegliere la qualità?

La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.

Visualizza la guida alle qualità BioReagent →

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.