methyl violet indicator - 15%(v/v)in iso-Propyl alcohol

Cat. No.: M196494
Disponibile su ordine
QUALITÀ & PUREZZA 15%(v/v)in iso-Propyl alcohol
Storage
Protected from light,Room temperature
Shipped In
Normal
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
500ml
M196494-500ml
Su ordinazione · 8–12 settimane

156,11€

230,73€
Salva 74,63 € (32.34%)
Enter a quantity for the sizes you want to add.

Panoramica

A useful dye and acidic pH indicator.

Specifiche

Specifiche e purezza
15%(v/v)in iso-Propyl alcohol
Condizioni di conservazione di stoccaggio
Protected from light,Room temperature
Spedito in
Normal

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Sicurezza e pericoli (GHS)
Pictogrammi
GHS05,   GHS07,   GHS08,   GHS09
Segnale
Danger
Indicazioni di pericolo

H302:Harmful if swallowed

H400:Very toxic to aquatic life

Precauzioni

P273:Avoid release to the environment.

Domande frequenti e articoli
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Application Protocols

The following are general, literature-based protocols for preparing and using methyl violet as an indicator. Adjust to your specific method requirements.

  1. Aqueous indicator stock (0.1% w/v)
  • Weigh 0.10 g methyl violet indicator mixture into a light-protected volumetric flask.
  • Add ~50 mL deionized water, swirl to dissolve; sonicate if needed.
  • Dilute to 100 mL with water, mix thoroughly.
  • Store in an amber bottle at room temperature, protected from light.
  • Use: add 1–3 drops per 100 mL of analyte. Expect yellow in very strong acid and violet/purple in less acidic/neutral conditions.
  1. Ethanolic stock (0.5% w/v) for nonaqueous titration
  • Dissolve 0.50 g in ethanol and dilute to 100 mL.
  • For titrations in glacial acetic acid with 0.1 N HClO4, add drops until a faint baseline color is visible; titrate to a distinct, persistent color change.
  1. Solution clarification (optional)
  • If particulates are present, filter through a 0.45 µm PTFE or nylon membrane into an amber vial.

Notes

  • Always standardize indicator addition (drop size) and lighting when comparing endpoints.
  • Validate performance in your exact medium; the transition range may shift with solvent strength and ionic composition.
Biological Roles

This product is intended for research and analytical laboratory use as a chemical indicator; it does not have intrinsic biological “roles” in a physiological sense. However, related triarylmethane dyes have interactions relevant to laboratory biology (literature, general):

  • Cationic dye behavior: electrostatically binds to negatively charged biomacromolecules (nucleic acids, acidic polysaccharides) and cell wall components; such interactions underlie staining applications of related dyes (e.g., crystal violet).
  • Staining utility: Methyl violet and congeners have been used as general stains for lignin and other anionic substrates in histology and materials biology, though crystal violet is more standard for Gram staining. Any staining use should be validated empirically, as mixture composition can affect hue and affinity.
  • Photophysical properties: strong visible absorption allows qualitative visualization and potential use as a tracer in flow studies; fluorescence is generally weak and solvent‑dependent for triarylmethane dyes.

Note: No clinical or diagnostic claims are made. For any biological application, perform compatibility tests with your specific matrix, as strong acidity required for the indicator transition is not compatible with most biological samples.

Buffer Applications

Methyl violet is an indicator dye rather than a buffering agent. It does not form a defined conjugate acid/base pair with a practical buffering window. Accordingly:

  • Not typically used to prepare buffers or to control pH.
  • Best employed as a visual endpoint indicator in highly acidic solutions or nonaqueous titration media where its sharp color change is advantageous.

For buffer preparation, choose classical buffering systems (e.g., citrate, acetate, phosphate) appropriate to your target pH and ionic strength, and use methyl violet only as a color indicator if operating in the very low pH regime.

Green Alternatives

When choosing indicators, consider environmental persistence, toxicity, and solvent demands.

Options and trade‑offs (literature, general):

  • Use pH electrodes or spectrophotometric probes: eliminate dye discharge and solvent use; best for quantitative work but require calibration and instrumentation.
  • Natural dye indicators (anthocyanins from red cabbage/hibiscus): renewable and low‑hazard; offer broad color changes but have diffuse transitions and poor stability in very strong acids where methyl violet excels.
  • Alternative synthetic indicators with improved profiles:
    • Bromophenol blue: effective in acidic range (~3.0–4.6), broader availability and established waste profiles; not suitable for the extremely low pH window where methyl violet is optimal.
    • Methyl orange: sharp transition in acidic region (~3.1–4.4) and widely used; does not cover the super‑acidic window.

Small comparison (literature):

  • Methyl violet: transition ~0.0–1.6; works in nonaqueous strongly acidic media; requires organic solvent stocks; dye discharge considerations.
  • Natural anthocyanins: biodegradable; transition spans several pH units but unreliable below pH ~1; limited solvent/waste concerns.
  • Electrode measurement: no indicator waste; requires equipment and maintenance.

Takeaway: For very acidic media and nonaqueous titrations, methyl violet performs uniquely well. Where feasible, prefer instrumental pH/acidimetry or greener indicators for less acidic ranges to reduce dye and solvent waste.

Pharmaceutical Uses

No therapeutic or clinical application is claimed for this product. In a pharmaceutical laboratory/manufacturing context (literature, general):

  • Potential roles are limited to analytical procedures, such as nonaqueous acidimetry of basic APIs using perchloric acid in acetic acid where methyl violet serves as a visual endpoint indicator.
  • It is not commonly used as an excipient or colorant in finished dosage forms due to regulatory and safety considerations around triarylmethane dyes.
  • Pharmacopeial status: There is no monograph specifically for “methyl violet indicator” mixture in major pharmacopeias to the best of general literature knowledge; specific dyes (e.g., crystal violet) may be referenced separately. Always consult current pharmacopeias for validated indicator choices in compendial methods.

For GMP environments, ensure indicator suitability by method validation, documenting lot‑specific performance (transition sharpness, absence of interfering absorbance) and adherence to internal quality specifications.

Physical Properties

Item‑specific physical constants are not provided for this mixture.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Melting point / decomposition: Not specified for this item; refer to CoA/Spec Sheet. (mixture values vary)
  • Boiling point: Not applicable (organic salts; dyes generally decompose before boiling) (literature, general).
  • Density: Not specified for this item; refer to CoA/Spec Sheet.
  • Solubility (literature, general):
    • Water: typically sparingly to moderately soluble, giving intensely colored solutions; solubility increases with added acid due to protonation of amino groups.
    • Ethanol and other polar organics: generally soluble; ethanol is commonly used for indicator stock solutions.
  • UV–Vis characteristics (literature, typical for methyl violet indicators): strong absorption in the visible region with λmax commonly near 580–600 nm in neutral/alkaline media; hypsochromic shifts and color changes occur upon strong acid protonation.
  • pKa/indicator transition (literature, general): color transition in very acidic range, approximately pH 0.0–1.6 (yellow → violet/purple depending on solvent and concentration). Exact transition range can vary with composition and medium.
  • LogP, refractive index, vapor pressure: Not typically defined for these solid dye mixtures; Not specified for this item; refer to CoA/Spec Sheet.

Note: As a formulated mixture (CAS 8004‑87‑3), specific constants may vary between lots; consult the CoA for lot‑specific values.

Quality and Grades
  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
  • Indicator‑grade considerations (general, literature): For pH indicators, key quality attributes include dye strength (tinting value), transition sharpness, absence of insoluble particulate, and minimal background absorbance at wavelengths used in analytical procedures. Because methyl violet indicator is a mixture, the exact composition (distribution of methylated homologs) can influence transition range and color tone.
  • What to expect with indicator‑grade materials:
    • Batch‑to‑batch consistency evaluated by colorimetric performance in standard solutions (e.g., defined HCl media).
    • Controlled inorganic impurities to minimize background in spectrophotometric work (limits typically defined on the CoA rather than catalog level).
    • Filtration/particle size managed to improve dissolution and clarity of solutions.
  • Stabilizers: Not specified for this item; refer to CoA/Spec Sheet. Most indicator dyes do not include added stabilizers; protection from light is the primary measure to minimize photofading.
  • Documentation: For quantitative or regulatory work, request and review the CoA/SDS for your lot to confirm composition notes, assay methods, and any performance tests (e.g., titration transition verification).
Reaction and Applications

Primary use is as a visual pH indicator for very acidic solutions and for nonaqueous titrations. It is not typically used as a reagent/catalyst in synthetic transformations.

Analytical applications (literature, general):

  • Strong acid indication: Clear color change between strongly acidic solutions (yellow) and less acidic/neutral (violet/purple), with a transition around pH 0.0–1.6 depending on medium and concentration.
  • Nonaqueous titrimetry: Indicator in glacial acetic acid media for perchloric acid titrations of weak organic bases (e.g., amines); confers a sharp end point due to pronounced protonation equilibria in low‑dielectric media.
  • Dye tracer/adsorption studies: Used to probe adsorption isotherms on carbonaceous or mineral surfaces due to strong visible absorbance and cationic nature.

Practical tips:

  • Prepare a clear stock solution in ethanol or water, filter if necessary through 0.2–0.45 µm PTFE/NYLON to remove undissolved particles.
  • Minimize exposure to strong oxidants or UV light; photobleaching reduces sensitivity.
  • In highly acidic/oxidizing matrices (e.g., concentrated H2SO4), assess compatibility—some triarylmethane dyes degrade rapidly.
  • For quantitative work, standardize appearance by using matched glassware, consistent pathlength, and controlled ambient lighting; where possible, verify equivalence with a pH meter.
Reaction Conditions

As an indicator, methyl violet is used under analytical rather than synthetic reaction conditions. Typical conditions (literature, general) include:

  • Aqueous strong acid indication:

    • Medium: water with strong mineral acids (e.g., HCl).
    • Concentration: indicator at ~0.02–0.1% w/v stock; a few drops per 50–100 mL analyte solution provide a clear color response.
    • Temperature: ambient.
  • Nonaqueous titration of bases:

    • Medium: glacial acetic acid with standardized perchloric acid titrant (0.1 N typical).
    • Indicator: methyl violet added as a dilute ethanolic solution until a distinct baseline color appears; endpoint recognized by a persistent color change (yellow ↔ violet) upon slight excess titrant.
    • Atmosphere: ambient; avoid moisture ingress in nonaqueous titrations to maintain accuracy.
  • Spectrophotometric studies:

    • Solvents: water, ethanol, or mixed solvents.
    • Wavelength monitoring: visible range with λmax near 580–600 nm depending on medium (for qualitative tracking).

These conditions are general guidance from analytical literature. Optimize concentration and addition volume empirically for your glassware, lighting, and sample matrix. For quantitative assays, verify with a pH electrode or a validated titrimetric method.

Safety and Handling
  • GHS classification, signal word, H‑statements, pictograms: Not specified for this item; refer to SDS for authoritative hazard information.
  • General hazards (literature, class-based): Triarylmethane dyes are intensely colored, may stain skin and materials, and can be harmful if swallowed or upon prolonged exposure. Dust may cause eye/respiratory irritation. Handle as a laboratory chemical of unknown acute toxicity.
  • PPE: Use lab coat, safety glasses or face shield, and appropriate chemical‑resistant gloves (e.g., nitrile). Avoid creating dust or aerosols. Work in a fume hood when weighing powders.
  • Storage conditions (item-specific): Protect from light; store at room temperature. Keep container tightly closed and in a dry place. Avoid prolonged exposure to air/humidity which can affect dye performance.
  • Incompatibilities (literature, general): Strong oxidizers (may degrade chromophore), strong reducing agents, and strong bases/acids can irreversibly alter color/form. Avoid contact with reactive bleaching agents.
  • First aid (overview; defer to SDS):
    • Inhalation: move to fresh air; seek medical attention if symptoms persist.
    • Skin contact: wash with soap and water; remove contaminated clothing.
    • Eye contact: rinse cautiously with water for several minutes; seek medical attention if irritation continues.
    • Ingestion: rinse mouth; do not induce vomiting; seek medical assistance.
  • Spill/leak: Avoid dust dispersion; collect with damp disposable towels or HEPA‑filtered vacuum; dispose of as dye‑containing chemical waste per institutional and local regulations.
Solvent Selection

Methyl violet indicator is generally used as an aqueous or hydroalcoholic solution depending on the analytical environment.

  • Polarity/Miscibility (literature, general):
    • Water: dissolves to give intensely colored solutions; solubility increases in acidic media.
    • Ethanol/IPA: good solubility and rapid wetting; ethanol is a common choice for preparing concentrated stock solutions (e.g., 0.1–1.0% w/v), later diluted into water or nonaqueous titration media.
    • Non-aqueous acid media (e.g., glacial acetic acid): employed for nonaqueous titrations of weak bases; indicator retains a sharp transition in strongly acidic organic media.
  • Selection guidance:
    • Choose water for routine visual pH indication at very low pH and for teaching labs.
    • Choose ethanol or mixed ethanol–water for rapid dissolution and to minimize microbial growth in stored stocks.
    • For nonaqueous titrimetry (perchloric acid in acetic acid), prepare stock in ethanol and dilute into the acetic acid medium right before use to maintain sensitivity.
  • Comparison (literature, general):
    • Versus methyl orange (azo dye): methyl orange has a slightly higher transition range (~3.1–4.4) and is better for strong acid/weak base titrations; methyl violet is preferred for super‑acidic ranges (~0.0–1.6).
    • Versus crystal violet: related chromophore; methyl violet mixtures provide a lower pH transition and more pronounced color change in very acidic media.
Storage and Reconstitution
  • Storage conditions (item-specific): Protect from light; store at room temperature. Keep container tightly closed in a dry place. Avoid prolonged exposure to humidity and direct sunlight.
  • Shipped in: Normal (ambient conditions), per product data.
  • Reconstitution (general guidance):
    • Prepare aqueous or ethanolic stock solutions at 0.1–1.0% w/v depending on intended use. Dissolve with gentle swirling; sonication can aid dissolution. Filter if clarity is required.
    • Use amber glassware/bottles to minimize photodegradation. Label with concentration, solvent, and preparation date.
  • Shelf life of solutions (literature, general): Indicator solutions are typically stable for weeks to a few months at room temperature when protected from light; discard upon noticeable fading, precipitate formation, or microbial growth (for aqueous stocks without preservative).
  • Freeze–thaw: Not applicable; store as dry solid or room‑temperature solutions protected from light.
  • Compatibility: Avoid storing solutions with strong oxidizers or at high pH; both conditions accelerate bleaching/decomposition.

For critical analytical applications, prepare fresh solutions frequently and verify performance against known standards. Refer to the product CoA/SDS for any lot‑specific handling notes.

Structure and Identity

Methyl violet indicator is a triarylmethane dye blend used as a pH indicator in very acidic ranges. Commercial “methyl violet” indicators are typically mixtures of N-methylated pararosaniline homologs (triarylmethane cations) and may include components such as pentamethyl- and hexamethyl‑pararosaniline (literature). Exact component ratios vary by supplier and lot.

  • SKU: M196494
  • Product name: methyl violet indicator (mixture)
  • CAS: 8004-87-3 (mixture CAS for methyl violet indicator)
  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet. (mixture)
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet. (mixture)
  • SMILES: Not specified for this item; refer to CoA/Spec Sheet. (mixture)
  • InChIKey: Not specified for this item; refer to CoA/Spec Sheet. (mixture)

Structural features (general, literature):

  • Core scaffold: triarylmethane (triphenylmethane) cation with para‑amino substituents on each ring and varying degrees of N‑methylation.
  • Counterions: commonly chloride or other halides in individual dye salts; mixture overall contains corresponding anions.
  • Chromophore: conjugated aryl system delocalized onto the central carbon; protonation state and resonance control color.

2D structure description (literature, generic): a central sp3 carbon attached to three para‑substituted aniline rings; the aniline nitrogens are dimethylated to varying extents across the mixture, giving highly conjugated, cationic dyes that interconvert in color upon protonation.

Synthetic Utility

Methyl violet is not a common synthetic reagent or catalyst. Its relevance to synthetic chemistry is primarily analytical and diagnostic (literature, general):

  • Endpoint visualization: facilitates titration control in strong acid media, including nonaqueous titrations used to assay basic functional groups (amines, amidines, guanidines) in organic synthesis and quality control.
  • Tracer dye: can qualitatively monitor mixing and phase behavior in process development due to intense coloration at low concentrations.
  • Acid sensitivity probe: qualitative screening of superacid strength or acidity gradients in media where conventional indicators fail, aiding method development for acid‑catalyzed transformations.

Reactivity notes (literature, class-based):

  • Triarylmethane dyes can undergo leuco (reduced) form generation under strong reducing conditions and oxidative bleaching with peroxides/oxidants—useful qualitatively to indicate redox environment but not generally exploited as a selective reagent.

For transformations requiring a functional additive, choose established reagents; use methyl violet only for visualization/analytical support to avoid introducing strongly colored impurities into reaction streams.

Target Specificity

Not applicable. This product is a chemical indicator dye, not a biological targeting reagent or antibody. No antigen, epitope, species reactivity, clone, or isotype information applies.

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.