MoAl/MoA1Mo Etchant - MOS grade

Cat. No.: M1523748
Disponibile su ordine
QUALITÀ & PUREZZA MOS grade ? MOS grade — high purity for metal-oxide-semiconductor processing. Use in MOS device fabrication sensitive to mobile-ion contamination.
Storage
Room temperature
Shipped In
Normal
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
500ml
M1523748-500ml
Su ordinazione · 8–12 settimane
112,72€
Enter a quantity for the sizes you want to add.

Specifiche

Specifiche e purezza
MOS grade
Condizioni di conservazione di stoccaggio
Room temperature
Spedito in
Normal
Grado
MOS grade

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Application Protocols

No validated biological assay protocols apply. For materials processing, a generalized wet‑etch workflow (literature/practice; adapt to your toolset) is provided for guidance only:

  1. Pre‑clean: Solvent clean (acetone/IPA) and DI water rinse; optional O2 plasma descum to remove organics (validate resist compatibility).
  2. Masking: Apply and pattern resist or deposit hard mask (SiO2/SiNx). Post‑bake per resist guidelines.
  3. Etch: Dispense/spray/immerse substrates in MoAl/MoA1Mo Etchant under controlled temperature and agitation. Track time from first contact.
  4. Rinse: Immediate DI water quench, followed by multi‑stage cascades to reduce ionic residues.
  5. Dry: IPA displacement and spin/vapor dry to avoid watermarking.
  6. Post‑etch clean: If required, brief DI rinse with mild complexant or base (only if compatible) to remove residual oxo species; verify by XPS/contact angle.
  7. Metrology: Measure step height, CD change, and inspect sidewalls for undercut/roughness. Note: Parameters such as temperature, time, agitation, and mask choice are process‑ and tool‑specific. Item‑specific operating instructions are Not specified for this item; refer to CoA/Spec Sheet and SDS.
Biological Roles

Not applicable. This product is a materials‑processing etchant for Mo/Al metallization and is not intended for biological systems. No biological function, pathway involvement, or cellular role is ascribed. For laboratory safety and environmental handling, see Safety & Handling and Green Alternatives.

Buffer Applications

Not applicable. This is not a buffering reagent and is not used to prepare biological or analytical buffers. For process interface considerations (rinsing, displacement drying, contamination control), see Solvent Selection.

Green Alternatives

Because detailed composition is not disclosed, greener‑chemistry assessment must be framed generically for Mo/Al wet etching (literature/practice): • Source reduction: Employ spray or puddle processing to reduce bath volume and extend bath life via point‑of‑use filtration. • Temperature minimization: Optimize chemistry to run effectively near room temperature to reduce energy usage. • Oxidizer choice: Where feasible, milder oxidants (e.g., dissolved oxygen or hydrogen peroxide under controlled conditions) can replace strong inorganic oxidizers, trading off etch rate for safety/environmental profile (general comparison – not item‑specific). • Waste management: Segregate metal‑bearing acidic effluents. Precipitate Al(OH)3 and molybdate under controlled neutralization; capture solids for compliant disposal. Closed‑loop recycling systems can reduce water and reagent consumption. • Worker safety: Select formulations with minimized VOC content and lower inhalation hazards; prefer aqueous systems over solvent‑rich alternatives when process performance allows. Illustrative comparison (general, not specific to this product): • Strong acid + oxidizer blends: High rate/selectivity; higher corrosivity and oxidizer hazards; greater PPE/containment needs. • Aqueous peroxide/complexant systems: Moderated rates; potentially lower toxic by‑products; narrower process window and sensitivity to metal catalysis. Item‑specific environmental attributes and any green certifications are Not specified for this item; refer to CoA/Spec Sheet.

Pharmaceutical Uses

Not applicable. This formulated etchant has no role as an excipient or pharmaceutical processing aid. It is supplied for materials science and semiconductor research only. For research use only.

Physical Properties

Because this is a formulated etchant rather than a single pure compound, classical single‑substance properties (bp, mp, logP, pKa) are not meaningful. Item‑specific specifications below: • Appearance: Not specified for this item; refer to CoA/Spec Sheet. • Density, viscosity, refractive index: Not specified for this item; refer to CoA/Spec Sheet. • pH, conductivity, metal ion content: Not specified for this item; refer to CoA/Spec Sheet. • Solubility: Typically aqueous systems are fully miscible with DI water (general/literature); item‑specific miscibility Not specified for this item; refer to CoA/Spec Sheet. • Boiling/flash point: Not specified for this item; refer to CoA/Spec Sheet. • Vapor pressure/odor: Not specified for this item; refer to CoA/Spec Sheet. Notes for users (general/literature guidance): • Etch performance is often temperature‑dependent for Mo and Al alloys; maintain tight bath temperature control for rate/selectivity consistency. • If the formulation is aqueous, expect full compatibility with DI water rinsing. Use cascade rinses to minimize residues. Always consult the product’s CoA/Spec Sheet and SDS for authoritative, item‑specific physical data before establishing process windows.

Quality and Grades

• Grade: MOS grade (semiconductor processing grade). In microelectronics, MOS‑grade chemicals are controlled for:

  • Low ionic contaminants (e.g., Na+, K+, Ca2+, transition metals) to minimize device contamination and leakage pathways.
  • Particle control with tight filtration specifications to protect critical dimensions and reduce defectivity.
  • Organic residue control and low total oxidizable carbon (TOC), supporting low film residues post‑etch and improved adhesion for subsequent steps.
  • Batch‑to‑batch consistency in etch rate and selectivity under defined process conditions. • What this means for this item: The etchant is intended for materials science and semiconductor‑adjacent research applications where trace contamination, particles, and bath stability matter. Specific impurity limits, filtration rating, and analytical methods are Not specified for this item; refer to CoA/Spec Sheet. • Stabilizers/inhibitors: If present, they can tune Mo vs Al selectivity and sidewall passivation (general/literature). Item‑specific stabilizers are Not specified for this item; refer to CoA/Spec Sheet. • Recommended qualification: Verify incoming lots via witness coupons (Mo, Al, Mo/Al/Mo) and metrology (profilometry/ellipsometry) to confirm etch rate/selectivity under your toolset and temperature controls before production experiments.
Reaction and Applications

Primary use (materials processing): Wet chemical etching of molybdenum/aluminum stacks (Mo/Al, Al/Mo, Mo–Al–Mo) used in TFT backplanes, MEMS metallization, and thin‑film interconnects (manufacturer category: materials science). This is not a synthetic reagent for classical organic reactions. General/literature mechanisms relevant to Mo/Al etching (not item‑specific): • Aluminum removal proceeds via oxidative dissolution to Al3+ with complexation; inhibitors can suppress lateral attack for improved anisotropy. • Molybdenum removal typically requires oxidizing species to form soluble Mo(VI) oxo complexes (e.g., molybdate), with rate strongly temperature and oxidant dependent. • Selectivity across Mo vs Al can be tuned via acidity, oxidizer strength, complexants, and inhibitors; galvanic coupling within Mo/Al stacks affects local rates. Practical tips (general): • Temperature control is critical; even small increases can accelerate etch rate and undercut. Use a thermostated bath and monitor solution age. • Agitation: Gentle agitation or megasonic assist can improve uniformity but may increase undercut—optimize empirically on witness coupons. • Masking: Hard masks (SiO2/SiNx) offer higher resistance than organic resists for long etches. • Metrology: Use test patterns and step‑height measurements (profilometry/AFM) to calibrate rate and uniformity. Post‑etch surface chemistry can be assessed by XPS to verify residual oxo species prior to subsequent deposition. Item‑specific etch rates, selectivities, or process windows are Not specified for this item; refer to CoA/Spec Sheet.

Reaction Conditions

Process use conditions for Mo/Al wet etching (general/literature guidance; not item‑specific): • Temperature: Many Mo/Al etchants operate effectively at ambient to moderately elevated temperatures; tighter control improves rate reproducibility and sidewall profile. Item‑specific setpoints are Not specified for this item; refer to CoA/Spec Sheet. • Mode: Immersion baths for batch processing; spray/puddle for single‑substrate tools. Gentle agitation improves uniformity; avoid air entrainment that can cause local inhibition. • Time: Determined empirically from coupon calibration; monitor in situ if possible (optical end‑pointing) or ex situ via profilometry. • Masking: Hard masks (SiO2/SiNx) recommended for prolonged exposures. Validate resist compatibility. • Rinse/dry: Immediate DI water quench, followed by overflow or cascade rinse, then IPA displacement or spin/vapor dry to avoid watermarking. • Materials of construction: PTFE/PFA tanks, quartz carriers, and fluoropolymer plumbing to prevent contamination and corrosion. • Bath management: Filtration to specified particle rating, periodic analysis for oxidizer content/metal load, and controlled replenishment to maintain steady etch kinetics. • Metrology: Use test patterns to quantify undercut and line‑edge roughness; verify selectivity to underlying dielectrics. Any explicit etch rates, selectivity ratios, or additive packages for this item are Not specified for this item; refer to CoA/Spec Sheet.

Safety and Handling

Item‑specific hazard classification (GHS signal word, hazard statements, pictograms): Not specified for this item; refer to SDS. General wet‑etch safety guidance (literature/practice; not item‑specific): • PPE: Wear chemical‑resistant gloves (e.g., butyl, Viton, or appropriate nitrile depending on SDS), splash goggles/face shield, acid‑resistant lab coat or apron. Use in a certified chemical fume hood. • Likely hazards: Many Mo/Al etchants are acidic and/or oxidizing; anticipate corrosivity and possible oxidizer reactivity. Avoid contact with skin, eyes, and clothing. Prevent mixing with incompatible materials (bases, cyanides, sulfides, strong reducers, and reactive metals) unless validated by SDS. • Engineering controls: Secondary containment for baths; temperature‑controlled recirculation if applicable; acid/chemical‑rated ventilation; HF/acid‑compatible scrubbers if volatile acids are present (verify with SDS). • First aid (summary; defer to SDS): Eye/skin contact—immediate copious water rinse for ≥15 min, remove contaminated clothing, seek medical attention. Inhalation—move to fresh air, monitor breathing, obtain medical care. Ingestion—do not induce vomiting; seek urgent medical assistance. • Spill/neutralization: For acidic systems, neutralize cautiously with appropriate base only if SDS permits; otherwise absorb with compatible inert sorbent and collect as hazardous waste. • Storage incompatibilities: Segregate from bases, oxidizable organics, and reactive metals; use acid/oxidizer‑rated cabinets as applicable. Always defer to the product SDS for definitive precautions and emergency measures.

Solvent Selection

This product is a formulated etchant and not a reaction solvent. Conventional “solvent selection” is therefore not directly applicable. Practical interface considerations (general/literature): • Rinsing: Use high‑purity DI water in multi‑stage cascade rinses to quench and remove residual etchant. Confirm with ICP/ion chromatography if ionic contamination is critical. • Displacement drying: Isopropyl alcohol (IPA) or IPA vapor drying is commonly used after DI rinses to mitigate watermark formation on wafers; ensure compatibility with the resist/films present. • Resist compatibility: Positive/negative photoresists and hard masks (SiO2/SiNx) vary in resistance to acidic/oxidizing baths; verify selectivity and swelling behavior. • Containment materials: Prefer PTFE, PFA, PVDF, or high‑grade HDPE reservoirs and tubing; avoid metals and unlined stainless steel. • Alternative media: If process integration requires, spray‑etch or puddle‑dispense modes reduce solution inventory and can improve uniformity compared with immersion (tooling dependent). Item‑specific miscibility and carrier solvent identity are Not specified for this item; refer to CoA/Spec Sheet.

Storage and Reconstitution

• Storage conditions (item‑specific): Room temperature (per Product Data). Keep container tightly closed in a dry, well‑ventilated area away from incompatible materials. Protect from direct sunlight and heat sources. Do not store near bases, reducing agents, or reactive metals unless SDS indicates compatibility. • Shipping: Shipped under normal conditions (per Product Data). • Stability/shelf life: Not specified for this item; refer to CoA/Spec Sheet. Monitor for changes in appearance or performance and follow any recommended bath life or replacement criteria. • Reconstitution: None indicated. Supplied ready‑to‑use unless the CoA/Spec Sheet specifies dilution. If concentration adjustment is required, use high‑purity DI water and acid/oxidizer‑compatible containers; add acid to water if applicable and mix under controlled conditions in a fume hood. • Container/material compatibility: Prefer PTFE, PFA, PVDF, or HDPE. Avoid contact with metals and non‑compatible elastomers. • Freeze–thaw guidance: Not applicable; store at room temperature as directed. Do not allow to dry to residue in process tools; flush lines with DI water during shutdowns. Always consult the SDS and CoA/Spec Sheet for definitive storage, compatibility, and handling instructions.

Structure and Identity

• Product type: Proprietary wet-etch chemistry formulated for selective removal of MoAl/Mo–Al–Mo metallization stacks and related molybdenum/aluminum layers in microfabrication. • Item-specific identifiers (CAS, InChIKey, SMILES, molecular formula, molecular weight): Not specified for this item; refer to CoA/Spec Sheet. • Composition: Not specified for this item; refer to CoA/Spec Sheet. • Structural features: As an etchant blend rather than a single molecule, this product does not have a single defined 2D structure; performance derives from its mixture of oxidizers/complexants/corrosion inhibitors and solvent medium (general/literature description). • Nomenclature context: “MoAl/MoA1Mo Etchant” suggests selectivity toward Mo/Al bilayers or Mo–Al–Mo stacks used in thin‑film transistor (TFT) and MEMS processing (general/literature context). • Purity/grade: MOS grade (semiconductor processing grade; see Quality & Grades tab).

Synthetic Utility

Classical synthetic transformations are not the target application for this product. However, from a materials‑chemistry perspective (general/literature): • Selective removal of Mo, Al, and Mo/Al/Mo layers enables microfabrication of interconnects, thin‑film electrodes, and MEMS structures, functioning as a subtractive patterning step complementary to PVD/CVD deposition. • Etch chemistry principles overlap with oxidative dissolution and complexation commonly studied in corrosion science; insights into passivation/inhibition, galvanic effects, and ligand‑assisted metal dissolution are relevant. • Integration utility: Enables via/contact definition, release etches in multilayer stacks, and pattern transfer where dry etch selectivity is insufficient or damage must be minimized. • Downstream compatibility: Effective wet etching can improve surface cleanliness and adhesion for subsequent dielectric or metal deposition, provided residues are controlled (verified by XPS/TOF‑SIMS and contact angle). Item‑specific functional additives and their roles (inhibitors, surfactants, complexants) are Not specified for this item; refer to CoA/Spec Sheet.

Target Specificity

Antibody or biomolecular target specificity does not apply. In a materials context, the intended target surfaces are Mo/Al metallization layers and Mo–Al–Mo stacks used in semiconductor and materials science research (general description). Item‑specific selectivity data are Not specified for this item; refer to CoA/Spec Sheet.

Hai bisogno di aiuto per scegliere la qualità?

La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.

Visualizza la guida alle qualità MOS grade →

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.