"}

Mouse 4-Hydroxynonenal (4-HNE) ELISA Kit

Disponibile
SKU
EJ1515455
Elementi prodotti raggruppati
Nome del prodotto Qtà
[EJ1515455-48T] Mouse 4-Hydroxynonenal (4-HNE) ELISA Kit (48T)
477,17 €
[EJ1515455-96T] Mouse 4-Hydroxynonenal (4-HNE) ELISA Kit (96T)
607,33 €

This kit employs the competitive enzyme-linked immunosorbent assay (ELISA) principle. Microplate wells are pre-coated with Mouse 4-HNE antigen. The sample, standards, a biotin-labeled antibody, and an HRP enzyme conjugate are then added sequentially to the wells. The procedure includes incubation and wash steps between each addition. TMB substrate is used for color development. In the presence of the peroxidase (HRP) enzyme, TMB is catalyzed to produce a blue color, which is then converted into a final stable yellow color upon the addition of an acid stop solution. The intensity of the resulting yellow color is inversely proportional to the concentration of Mouse 4-HNE in the sample. The optical density (OD) is measured at a wavelength of 450 nm using a microplate reader, and the concentration of the target analyte in the sample is calculated based on the standard curve.

Maggiori Informazioni

Maggiori Informazioni
Specifiche e purezzaBioReagent
Campo di rilevamento0.625ng/mL~40ng/mL
Specie rilevata OggettoMouse
SpecificitàDetecting Mouse 4-HNE in samples, with no significant cross-reactivity to other homologs.
Product Description

This kit employs the competitive enzyme-linked immunosorbent assay (ELISA) principle. Microplate wells are pre-coated with Mouse 4-HNE antigen. The sample, standards, a biotin-labeled antibody, and an HRP enzyme conjugate are then added sequentially to the wells. The procedure includes incubation and wash steps between each addition. TMB substrate is used for color development. In the presence of the peroxidase (HRP) enzyme, TMB is catalyzed to produce a blue color, which is then converted into a final stable yellow color upon the addition of an acid stop solution. The intensity of the resulting yellow color is inversely proportional to the concentration of Mouse 4-HNE in the sample. The optical density (OD) is measured at a wavelength of 450 nm using a microplate reader, and the concentration of the target analyte in the sample is calculated based on the standard curve.

Condizioni di conservazione di stoccaggioStore at 2-8°C
Spedito inWet ice
Stabilità e conservazioneStore at 2-8℃ for 6 months.

Recensioni

Recensioni dei clienti

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.

Copyright © 2023-present Aladdin Scientific Corp All rights reserved.