MS Columns - BioReagent, sterile

Cat. No.: M1520097
Disponibile su ordine
QUALITÀ & PUREZZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization.
Synonyms
gM Columns
Storage
Room temperature
Shipped In
Normal
Application
Cell analysis
★
Dimensione
Germania (EU)
USA*
Prezzo
Qtà
1EA
M1520097-1EA
Su ordinazione · 8–12 settimane
25,95€
25EA
M1520097-25EA
Su ordinazione · 8–12 settimane
216,85€
Enter a quantity for the sizes you want to add.

Panoramica

Cell separation column is a specialized consumable designed for column-based cell sorting, developed specifically for the gentle isolation of cells labeled with nanomagnetic beads. Due to the extremely small size of the cell separation nanomagnetic beads (particle size: 50–100 nm), a high-intensity magnetic field is required to attract the labeled cells. The column contains an optimized matrix that, when used with a magnetic separation system, amplifies the magnetic field nearly ten-thousand-fold, enabling efficient capture and gentle elution of magnetically labeled cells. It is widely used for cell enrichment, depletion, and sorting in research and preclinical stages.


Cat. No.
Product Name
Max. Load of Labeled Cells
Max. Total Cell Load
M1520097MS Columns
1× 10⁷
2× 10⁸
L1520103LS Columns
1× 10⁸
2× 10⁹

Note: When isolating cells larger than lymphocytes, the column capacity may be reduced.



Procedure

1. Column Preparation

(1) Column installation: Insert the separation column into a suitable magnetic stand, ensuring the column wings face forward. Place a collection tube at the column outlet.

(2) Column priming: Add 500 μL of separation buffer to the column and allow it to flow through naturally.

(3) Discard flow-through: Replace the collection tube. The column is now ready.


2. Magnetic Separation

Magnetic labeling must be performed before magnetic separation. Refer to the nanomagnetic bead instructions for specific labeling methods.

(1) Cell suspension preparation: Resuspend cells in separation buffer, using 50 μL of buffer per 10⁷ cells.

Note: For higher cell numbers, increase the buffer volume accordingly.


(2) Sample loading: Apply the cell suspension to the prepared column. Collect the flow-through containing unlabeled cells.


(3) Washing: Wash the column three times with 500 μL of separation buffer. Collect the unlabeled cells that pass through and combine them with the flow-through from step (2).

Note: Once the column reservoir is empty, immediately add the same volume of buffer for the washing steps.


(4) Remove the column and place it on a new collection tube.


(5) Elution: Add 1 mL of separation buffer to the column and use the supplied plunger to quickly elute the magnetically labeled cells.

Note: (Optional) To improve the purity of magnetically labeled cells, the eluted cells can be passed through a second MS column for re-sorting.



Precautions

  1. The MS columns and matching plunger are supplied individually in sterile packaging. They are intended for single use and reuse is not recommended.

  2. Prepare the separation buffer before the experiment: PBS (pH 7.2), 0.5% BSA, and 2 mM EDTA. Mix thoroughly and store at 4 °C.

  3. Due to differences in samples and research objectives, optimal experimental conditions should be determined by the user.

  4. This product is for research use only.

  5. For your safety and health, please wear a lab coat and disposable gloves during operation.

Specifiche

Sinonimi
gM Columns
Specifiche e purezza
BioReagent, sterile
Stabilità e conservazione
Store at room temperature long term (24 months).
Condizioni di conservazione di stoccaggio
Room temperature
Spedito in
Normal
Grado
BioReagent, Sterili
Product Line
Prodotti biologici

Dati avanzati

Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate TypeDataOggetto
ZJ26F0737619ZJ26F0737619Certificate of AnalysisJul 21, 2026 M1520097
ZJ26F0737620ZJ26F0737620Certificate of AnalysisJul 21, 2026 M1520097
Domande frequenti e articoli
Calcolatori di soluzioni
Recensioni

Recensioni dei clienti

Hai bisogno di aiuto per scegliere la qualità?

La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.

Visualizza la guida alle qualità BioReagent → Visualizza la guida alle qualità Sterile →

Desidera che le inviamo un messaggio quando avremo sconti disponibili?

Ricordamelo più tardi

Grazie! Controlli la sua casella di posta per confermare.

Ops! Le notifiche sono disabilitate.