QUALITÀ & PUREZZAMoligand™?Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools.
This compound belongs to the class of organic compounds known as phosphosphingolipids. These are sphingolipids with a structure based on a sphingoid base that is attached to a phosphate head group. They differ from phosphonospingolipids which have a phosphonate head group.
External Descriptors
Not available
1. Djoumbou Feunang Y, Eisner R, Knox C, Chepelev L, Hastings J, Owen G, Fahy E, Steinbeck C, Subramanian S, Bolton E, Greiner R, and Wishart DS. ClassyFire: Automated Chemical Classification With A Comprehensive, Computable Taxonomy. Journal of Cheminformatics, 2016, 8:61.
Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calcolatori di soluzioni
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Recensioni
Recensioni dei clienti
Application Protocols
Tested/validated applications and recommended conditions for this specific catalog item are Not specified for this item; refer to CoA/Spec Sheet.
Please consult primary literature and institutional SOPs for protocol development involving [³²P] radioligands. Given the radiological nature of the product, ensure protocol approval by your Radiation Safety Office prior to use.
Biological Roles
General/literature overview of S1P biology (not product‑specific)
Signaling lipid: Sphingosine‑1‑phosphate is a potent extracellular and intracellular mediator. Extracellular actions are primarily via GPCRs S1PR1–S1PR5, influencing cytoskeletal dynamics, endothelial barrier integrity, vascular tone, and immune cell trafficking.
Gradient physiology: S1P concentrations form vascular–tissue gradients maintained by synthesis (sphingosine kinases) and degradation (S1P lyase, S1P phosphatases), guiding lymphocyte egress and other trafficking processes.
Intracellular roles: Modulates calcium signaling, apoptosis pathways, and epigenetic regulators through protein interactions and potential intracellular targets.
Carriers and distribution: In blood, S1P is bound mainly to ApoM on HDL and to albumin, affecting receptor bias and pharmacodynamics in vitro.
Use of [³²P]S1P as a probe (literature)
Enables sensitive tracking of binding, uptake, and metabolism using radiometric detection without altering the lipid headgroup chemistry beyond isotopic substitution.
Note: Biological information provided here is general background to inform research use. No medical or clinical claims are made. Item-specific biochemical data (e.g., specific activity, binding constants) are Not specified for this item; refer to CoA/Spec Sheet.
Buffer Applications
Not typically used as a buffering agent. [³²P]S1P is a radiolabeled lipid tracer, not a pH buffer component.
Practical notes (literature/general) for assay buffers involving S1P
Include fatty acid–free BSA (e.g., 0.1–0.5%) or mild nonionic detergent to reduce adsorption and maintain monomeric availability.
Maintain near‑physiological pH (7.2–7.4) with standard buffers (HEPES, PBS) compatible with radiometric detection.
Use low‑binding plastics and pre‑wetting with vehicle to improve recovery.
Item-specific buffer recommendations for this product are Not specified; refer to CoA/Spec Sheet and assay‑specific literature.
Green Alternatives
Context: The environmental and safety footprint of [³²P]S1P is dominated by radioisotope handling and associated solvent systems (e.g., chloroform, methanol). Greener choices focus on minimizing hazardous solvents and considering non‑radioactive tracers where feasible.
Alternative tracers (literature/general)
Non‑radioactive MS‑tracers: Stable‑isotope labeled S1P (e.g., d7‑S1P) quantified by LC‑MS/MS eliminates radiological waste; requires MS access and may have different sensitivity/backgrounds.
Fluorescent S1P analogs: Enable microscopy/flow readouts; potential to alter receptor/transport interactions due to bulky fluorophores.
Lower‑energy radioisotopes: [³H]S1P offers reduced external dose but lower specific activity and different detection methods.
Solvent/system substitutions
Replace chloroform with cyclopentyl methyl ether (CPME) or ethyl acetate where separation goals permit; however, classic lipid partitioning and TLC often rely on chlorinated solvents for resolution (trade‑off).
Aqueous buffers with carrier proteins can reduce total organic solvent usage during assay setup.
d‑label/MS: no radiation, high specificity, instrumentation‑intensive.
Fluorescent analogs: imaging‑capable, potential perturbation of native biology.
Select the approach aligned to assay needs, safety infrastructure, and waste minimization goals. Item-specific green attributes for this product: Not specified; refer to CoA/Spec Sheet.
Pharmaceutical Uses
This product is intended strictly for research use only (from Product Data) and is not formulated or approved for clinical or diagnostic use.
As a radioligand, [³²P]S1P can support discovery‑stage studies of S1P receptor ligands, transporters, and metabolic enzymes by enabling quantitative binding/turnover assays.
It is not an excipient or dosage‑form component. No pharmacopeial monograph applies to this radiolabeled tracer. Any process‑development or QC applications would be preclinical and method‑development in nature.
Item-specific pharmacopeial or compliance status: Not specified for this item; refer to CoA/Spec Sheet.
Physical Properties
Item-specific specifications
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Grade/Purity: Moligand™ (see Quality & Grades tab for context).
General/literature properties of S1P (unlabeled unless noted)
Molecular formula (neutral S1P, literature): C18H38NO5P
Molecular weight (neutral S1P, literature): ~379.46 g/mol; [³²P] substitution increases monoisotopic mass by ~1 u (literature).
Physical state: amphiphilic lipid; typically viscous oil/film or solution when supplied; forms micelles/aggregates in water with carrier proteins (literature).
Solubility (literature):
Organic: soluble in lower alcohols (methanol, ethanol), chloroform, and chloroform:methanol mixtures.
Aqueous: low intrinsic solubility; often handled in aqueous buffers containing fatty acid–free BSA or detergents to prevent adsorption and aggregation.
LogP/logD (literature): high hydrophobicity (long alkyl chain) with ionizable headgroup; effective partitioning depends strongly on pH and counterions.
pKa (literature): phosphate monoester pKa1 ~1–2, pKa2 ~6–7; primary amine pKa ~8–9, conferring zwitterionic character near neutral pH.
Range in tissue/plastic: a few millimeters; use low‑Z shielding (acrylic).
Note: Specific numerical specs for this catalog item (e.g., solvent, concentration, density, refractive index) are not specified; refer to CoA/Spec Sheet.
Quality and Grades
Item-specific grade
Grade/Purity: Moligand™ (from Product Data). This denotes an Aladdin research‑grade ligand product line suited for biochemical and chemical biology studies. For [³²P]S1P, this typically implies suitability as a radioligand tracer in receptor/transport/metabolism assays. Exact purity, specific activity, counter‑ion, solvent, stabilizers, and UV profile are Not specified for this item; refer to CoA/Spec Sheet.
What “radioligand suitability” often entails (general)
Identity confirmation (e.g., by HPLC/TLC vs. standard S1P) and radiochemical identity (co‑elution with cold reference).
Radiochemical purity typically assessed by radio‑HPLC or radio‑TLC; stability testing over time under recommended storage. Specific activity and date/time of calibration are critical for quantitation (not provided here).
Low non‑volatile residue and minimized carriers to ensure predictable binding and partitioning behavior.
Stabilizers and formulation (general notes)
Many S1P radioligand preparations include ethanol/water or buffered aqueous vehicles and may contain trace stabilizers or carrier lipid to limit adsorption and radiolysis. For this catalog item, formulation details are Not specified; consult CoA/Spec Sheet.
Fit for purpose
The Moligand™ designation signals a focus on ligand‑based research applications rather than analytical trace analysis or clinical use. For chromatography‑grade or bioassay‑grade solvents and excipients, see alternative grades in our catalog.
Reaction and Applications
This product serves primarily as a radiotracer rather than a synthetic reagent. Key application domains (literature/practice):
Receptor binding and pharmacology
Quantify binding to S1P GPCRs (S1PR1–S1PR5) in membrane preparations or intact cells. Use saturation/isotherm analyses (Kd/Bmax) and competition assays to profile ligands. Pay attention to non‑specific binding due to amphiphilicity; include BSA and adequate wash steps.
Transport and trafficking studies
Trace S1P uptake/efflux across cell membranes, association with carrier proteins (e.g., albumin, ApoM/HDL), and compartmentalization. Pulse‑chase paradigms leverage the 14.3‑day half‑life for multi‑day kinetics.
Metabolic fate and enzyme assays
Monitor turnover by S1P lyase, S1P phosphatases, and lipid phosphate phosphatases. Radiometric TLC/HPLC separates S1P from sphingosine or phospho‑products; quantify with phosphor imaging or scintillation counting.
Lipid extraction and analysis
Employ Folch or Bligh–Dyer extractions; separate by normal‑phase TLC (e.g., chloroform/methanol/aqueous systems). Use radiodetection to follow recovery and conversion.
Practical tips (general)
Work quickly to limit radiolysis; keep dilute working stocks in ethanol or buffer with carrier/BSA. Minimize surface exposure to reduce adsorption losses.
Validate co‑migration with non‑radioactive S1P standards. Regularly verify radiochemical purity by radio‑HPLC or radio‑TLC.
Item‑specific validated applications: Not specified for this item; refer to CoA/Spec Sheet.
Reaction Conditions
As a radioligand tracer, [³²P]S1P is used under assay rather than synthetic reaction conditions. Representative literature conditions are provided for planning purposes; adapt to your system and consult primary sources.
Temperature/time: 25–37 °C, 30–90 min for equilibrium; verify with time‑course.
Ligand range: 0.05–5 nM radioligand common for saturation; competitor range depends on expected affinity.
Separation: rapid filtration through PEI‑treated GF/B or GF/C filters; extensive cold buffer washes to minimize nonspecific binding.
Enzymatic turnover (S1P phosphatases/lyase)
Buffer: Tris or HEPES (50 mM), Mg2+ as required, 0.05% Triton X‑100 or BSA to solubilize; pH 7.4–8.0.
Temperature/time: 30–37 °C; 10–60 min; ensure linearity with respect to enzyme and time.
Readout: radio‑TLC/HPLC with phosphor imaging or scintillation counting of excised bands/peaks.
Lipid extraction and TLC
Extraction: Bligh–Dyer (CHCl3:MeOH:H2O ~1:2:0.8 v/v/v) or Folch (CHCl3:MeOH 2:1), partition to recover organic phase.
TLC systems: CHCl3:MeOH:NH4OH:H2O (e.g., 90:54:8:10) are commonly used; optimize for resolution between S1P and sphingosine.
These are general literature conditions. Item‑specific recommended conditions are Not specified for this item; refer to CoA/Spec Sheet.
Safety and Handling
Item-specific hazard fields (from Product Data)
GHS Classification / Signal Word / Pictograms / H‑Statements: Not specified for this item; refer to SDS.
General safety for [³²P] radiolabeled phosphates (literature/best practice)
Radiation hazards: ³²P is a high‑energy β− emitter (Emax ~1.71 MeV). Primary risks are external β exposure to skin/eyes and contamination leading to internal exposure. No substantial penetrating gamma; secondary bremsstrahlung can arise with high‑Z shielding.
Shielding: Use low‑Z materials (acrylic/Plexiglas) for benchtop shielding; avoid lead as primary shielding for β emitters to limit bremsstrahlung X‑rays.
Dosimetry and monitoring: Wear ring badges and whole‑body dosimeters as per institutional policy. Conduct regular wipe tests and use survey meters (Geiger or GM with appropriate window) for contamination monitoring.
PPE: Lab coat, double nitrile gloves with frequent changes, eye protection (safety glasses or face shield). Designate a radioisotope work area with absorbent bench pads and secondary containment.
Handling: Work behind acrylic shields; minimize stock handling time; use dedicated pipettes and tips; confirm integrity of vials before opening. Avoid aerosols and splashes.
Storage incompatibilities: Keep physically segregated in a lockable, labeled radioactive materials area. Avoid high‑Z shielding in close contact with the source. Keep away from strong bases/acids that could volatilize or degrade matrices.
First aid and spills: Follow institutional radiation safety procedures. For skin contamination, remove gloves, wash gently with mild soap and tepid water; survey and repeat until background. For spills, evacuate, contain, notify RSO, and decontaminate per SOP.
Waste: Collect in appropriately shielded, labeled containers; segregate ³²P waste; decay‑in‑storage is feasible given T½ ~14.3 d, per license and regulations.
Always defer to the SDS and institutional radiation safety program for authoritative guidance.
Solvent Selection
Applicability: [³²P]S1P is an amphiphilic lysophospholipid radiotracer. Solvent choice critically affects recovery (adsorption losses), micellization, and bioassay performance.
General/literature guidance
Organic handling
Chloroform:methanol (2:1 or 1:1, v/v) efficiently dissolves S1P for stock preparation and TLC. Pure methanol or ethanol can be used for radioligand aliquoting and rapid mixing into aqueous buffers.
Aqueous handling
In water or buffer alone, S1P adheres to plastic and glass; incorporating fatty acid–free BSA (e.g., 0.1–0.5% w/v) or mild detergents (e.g., 0.05% Triton X‑100) improves recovery and reproducibility.
pH near neutrality (phosphate pKa2 ~6–7; amine pKa ~8–9) favors zwitterionic forms; ionic strength and counter‑ions modulate aggregation.
Materials compatibility
Use low‑binding polypropylene tubes; pre‑wet tips/vials with vehicle (e.g., ethanol) to minimize wall adsorption. Glass silanization can help for analytical work.
When to choose alternatives
For receptor binding assays in membranes/cells, aqueous buffers supplemented with carrier protein are preferred to maintain bioactive monomeric pools and minimize non‑specific binding.
For lipid extraction, separation, or derivatization, chloroform:methanol systems provide solubility and phase partitioning control.
Item-specific solvent/vehicle for this product: Not specified for this item; refer to CoA/Spec Sheet.
Storage and Reconstitution
Item-specific storage (from Product Data)
Storage Conditions: Room temperature.
Shipped In: Not specified for this item; refer to CoA/Spec Sheet.
General/literature guidance for [³²P]S1P
Radiolysis considerations: Higher activity solutions can undergo radiolysis; store in small aliquots, minimize headspace, and limit light exposure. Amber vials and ethanol‑containing vehicles can improve stability.
Containers: Use low‑binding polypropylene or silanized glass. Pre‑rinse vials and tips with vehicle (e.g., ethanol) prior to aliquoting to reduce adsorption.
Activity decay: ³²P half‑life is 14.29 days; plan experiments using decay corrections from the calibration date.
Reconstitution (if provided as dried film or concentrate; general)
Dissolve initial material in methanol or ethanol to prepare a concentrated stock; then dilute into assay buffer containing fatty acid–free BSA (e.g., to 0.1–0.5% w/v) to minimize losses.
Mix gently; avoid foaming/aerosol generation. Verify radiochemical purity by radio‑TLC/HPLC before critical assays.
For exact formulation, solvent system, concentration, stabilizers, and shelf life of this catalog item: Not specified for this item; refer to CoA/Spec Sheet. Always comply with institutional radiation safety requirements for secure, labeled storage of ³²P sources.
Structure and Identity
Brief description: [³²P]S1P is the radiolabeled form of sphingosine‑1‑phosphate (S1P) in which the phosphate is phosphorus‑32, a high‑energy β− emitter used as a tracer in biochemical studies of S1P signaling, transport, and metabolism.
Item-specific identifiers (from Product Data)
SKU: P614024
Product Name: [³²P]S1P
CAS: P614024 (catalog identifier as provided)
CID: 73755115
InChIKey: 73555 (as provided)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
Structural features (general/literature description of S1P)
Core scaffold: long‑chain sphingoid base (trans‑4‑sphingenine) bearing a primary alcohol (C1), secondary alcohol (C3), trans C4–C5 alkene, and a terminal amino group at C2.
Phosphate: S1P bears a phosphate monoester at C1; in [³²P]S1P this phosphate oxygen framework is bound to ³²P.
Amphiphilicity: cationic headgroup (protonated amine at physiological pH) plus anionic phosphate; hydrophobic C18 tail.
2D structure in words (general/literature)
Linear C18 chain with one trans double bond around the middle; C1 linked to a phosphate monoester (³²P), C2 bearing NH2, C3 bearing OH. The phosphate group (PO3−) carries the radioactive ³²P isotope used for tracing.
Notes on isotopic labeling (general)
Replacement of ³¹P by ³²P does not change connectivity but increases the monoisotopic mass by ~1.0 u and confers β− radioactivity (T½ ~14.3 d, literature).
Synthetic Utility
[³²P]S1P is generally not used as a synthetic building block; it is the radiolabeled product of phosphorylation of sphingosine. However, it is valuable in mechanistic and enzymatic “synthetic‑adjacent” contexts (literature/general):
Enzymatic reaction tracing
Follow dephosphorylation by lipid phosphate phosphatases or S1P phosphatases to sphingosine, enabling kinetic parameter estimation by radiometric assays.
Track irreversible cleavage by S1P lyase into hexadecenal and phosphoethanolamine; radiolabel remains on the phosphate‑derived fragment, aiding pathway assignment depending on analytical separation.
Process development and analytics
Validate extraction/separation methods for sphingolipids (e.g., Bligh–Dyer vs. Folch) by spike‑recovery experiments, informing method robustness for non‑radioactive workflows.
Affinity and partitioning studies
Quantify binding to proteins (albumin, ApoM) or membranes, informing formulation and delivery strategies for lipidic modulators.
For classical organic synthesis (bond construction), this reagent is not typically applicable; consider non‑radioactive S1P or its protected intermediates if chemical modifications of the sphingoid base or headgroup are desired.
Target Specificity
Only item-specific information may be listed here. For this product, target/epitope/clone/species details are Not specified for this item; refer to CoA/Spec Sheet.
General note: As a small‑molecule radioligand, [³²P]S1P interacts with S1P receptors (S1PR1–S1PR5) and S1P‑binding proteins; however, no product‑specific target validation data are provided in the Product Data.
Domande frequenti
What is Moligand??
Moligand? is one of Aladdin Scientific's premium product lines, formulated for high-purity applications across multiple workflows. Compared to standard grades in the same workflow, Moligand? products typically offer tighter specifications, more rigorous QC, and stronger lot-to-lot consistency.
How should this product be stored?
Store at room temperature.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is P614024. InChIKey DUYSYHSSBDVJSM-CRGHQYIOSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Hai bisogno di aiuto per scegliere la qualità?
La nostra guida alla selezione delle qualità copre purezza, stato dello stabilizzatore e idoneità all'applicazione per tutte le varianti del nostro catalogo.
Utilizziamo i cookie per garantire il corretto funzionamento del sito web e, ove consentito, per migliorare la tua esperienza. Puoi gestire le tue preferenze in qualsiasi momento nelle Impostazioni. Per saperne di più, consulta la nostra Cookie Policy.
Desidera che le inviamo un messaggio quando avremo sconti disponibili?
Ricordamelo più tardi
Grazie! Controlli la sua casella di posta per confermare.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.