Item-specific tested applications: Not specified for this item; refer to CoA/Spec Sheet.
General protocol guidance (literature/general)
MVR/MFR measurement (ISO 1133-1 / ASTM D1238):
Condition instrument at 230 °C. Use 2.16 kg load (for standard PP). Clean barrel and orifice; verify diameter.
Charge a known mass of PP (e.g., 4–6 g pellets). Preheat for a defined dwell (e.g., 7 min per ISO) to reach thermal equilibrium.
Purge a small amount to eliminate air/shear history. Begin timed extrudate cuts; collect for a fixed interval (e.g., 30 s) or piston displacement.
Determine MFR (g/10 min) by mass of extrudate, or MVR (cm³/10 min) from piston displacement, applying instrument constants and temperature/load corrections.
Report condition code (e.g., 230 °C/2.16 kg), number of determinations, and mean ± SD. Note any visible fillers/pigments.
HT-GPC sample prep: Dissolve PP at 150 °C in TCB with 0.05% BHT under nitrogen for 1 h; filter hot; analyze on high-temp columns at 145 °C against polystyrene or PP-like standards (acknowledging Mark–Houwink differences). Parameters are illustrative only.
Biological Roles
Applicability
Polypropylene is a synthetic polyolefin with no intrinsic biological role or metabolic pathway.
General laboratory context (literature/general)
Biocompatibility: PP is broadly considered chemically inert and has long-standing use in laboratory disposables (tubes, pipette tips) due to low extractables and good chemical resistance. Actual biocompatibility depends on grade, additives, and regulatory testing not specified here.
Protein and cell interaction: Hydrophobic, low-surface-energy character leads to poor protein adsorption and limited cell adhesion unless surface-treated (e.g., plasma oxidation, corona discharge) or coated.
Thermal and chemical resistance: Suitable for many biological workflows requiring resistance to aqueous buffers and mild solvents; not autoclavable indefinitely without stabilizers, as repeated steam cycles can induce oxidation/embrittlement in unstabilized grades.
Item-specific biological data
None provided for this item. No biological performance claims are made. For research use only.
Buffer Applications
Not typically applicable
Polypropylene is a solid thermoplastic and does not serve as a buffering agent. It is commonly used as a container or material for handling buffers, owing to chemical resistance.
Practical notes (literature/general)
Compatibility: Stable with most aqueous buffers across broad pH ranges at ambient temperature; avoid strong oxidizing solutions which can attack PP over time.
Adsorption: Low nonspecific adsorption to PP can be advantageous for protein/biomolecule handling, though specific assays may still benefit from low-bind or surface-treated labware.
Green Alternatives
Context
Polypropylene is a hydrocarbon thermoplastic processed solvent-free by melt techniques, aligning with green chemistry principles of minimizing solvents. However, analytical dissolution (e.g., HT-GPC) often relies on chlorinated, high-boiling solvents.
Greener considerations (literature/general)
Solvent-free processing: Prefer extrusion/injection molding for blending and modification instead of solution processing where feasible.
Alternative eluents: Decalin or tetralin can substitute for 1,2,4-trichlorobenzene in some high-temperature analyses, lowering halogenated solvent use; still require elevated temperature and appropriate inhibitors.
Stabilization: Using efficient antioxidant packages reduces processing temperature and residence time, decreasing energy use and oxidative waste.
Recycling and circularity: PP is widely recyclable (mechanical recycling). Designing experiments that maintain polymer integrity (avoiding unnecessary crosslinking/fillers) improves downstream recyclability.
Comparison (literature; qualitative)
1,2,4-Trichlorobenzene: Excellent PP solvent for HT-GPC; hazardous, halogenated, persistent.
Decalin: Effective at similar temperatures; non-halogenated, flammable; may have higher viscosity and slower dissolution.
o-Dichlorobenzene: Halogenated, somewhat lower bp than TCB; still hazardous.
Melt-only workflows: Highest EHS benefit; limited to processing studies rather than solution-based analytics.
Pharmaceutical Uses
Scope
No therapeutic claims. The following pertains to materials and manufacturing context only (literature/general).
General use in pharma/bioprocess settings
Primary packaging and disposables: PP is widely used for syringes, IV components, vials, closures, and single-use systems due to low extractables and heat resistance. Specific compliance (e.g., USP <661.1>/<661.2>, EU Ph. Eur. 3.1.3) is grade-dependent and Not specified for this item; refer to CoA/Spec Sheet.
Processing aids: PP components are used in filtration housings, connectors, and manifolds; gamma-stable and steam-sterilizable grades exist but require defined additive packages.
Formulation role: PP is not an excipient; rather, it is a contact material. Extractables/leachables profiles depend on antioxidants, slip agents, and nucleators—details Not specified for this item; refer to CoA/Spec Sheet.
Considerations for selection
Thermal requirements: Choose grades with appropriate melt flow (MFR/MVR) and stabilization for sterilization method (steam vs. gamma).
Regulatory testing: Verify USP/EP compliance, biocompatibility, and E/L studies for the intended application; not provided for this item.
Physical Properties
Item-specific (from Product Data)
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Any numerical specifications (mp, density, additives, MFR/MVR value): Not specified for this item; refer to CoA/Spec Sheet.
General physical data (literature/typical; not specifications for this item)
Density: ~0.89–0.91 g/cm³ (isotactic PP; 23 °C).
Melting temperature (Tm): ~130–171 °C depending on tacticity and crystallinity (isotactic grades commonly ~160–165 °C).
Glass transition (Tg): ~−10 to −20 °C.
Heat deflection temperature: ~95–120 °C (load-dependent; filled grades higher).
Solubility: Insoluble in most solvents at room temperature; swells in aliphatic/aromatic hydrocarbons. Soluble when hot in xylene, decalin (decahydronaphthalene), and 1,2,4-trichlorobenzene (TCB) used for high-temp GPC (~135–160 °C).
Refractive index: ~1.49 (sodium D line, 20–25 °C).
Surface energy: Low (~30 mN/m), leading to poor wettability and adhesion without pretreatment.
Thermal behavior: Oxidative degradation above ~200 °C without stabilizers; processing typically 180–230 °C with antioxidants.
Notes for MVR context (literature)
MVR/MFR measurement for PP is commonly at 230 °C under a 2.16 kg load (ISO 1133-1 / ASTM D1238). Actual values are material specific and not provided for this item.
Quality and Grades
Item-specific (from Product Data)
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Intended use: For research use only.
Context for “for Melt Volume Flow Rate” (literature/general)
Melt Volume-Flow Rate (MVR) and Melt Mass-Flow Rate (MFR) are standardized rheological indices used to compare processability and molecular weight distribution of thermoplastics.
Standards: ISO 1133-1/2 and ASTM D1238 define test conditions. For polypropylene, the most common condition is 230 °C with a 2.16 kg load (alternative loads used depending on grade).
Implications for quality: Materials referenced for MVR testing are typically clean, dry, and of defined stabilization state (antioxidant package) to minimize thermal oxidation during the test. Moisture is generally not critical for PP, but cleanliness and absence of volatiles/fines enhance repeatability.
Additives: Commercial PP often contains antioxidants (e.g., hindered phenols, phosphites) and may include nucleating agents. Presence/level/type of stabilizers and any fillers/pigments substantially affect MVR—these details are item-specific and are Not specified for this item; refer to CoA/Spec Sheet.
Trace analysis: UV cutoff, metals, or residual monomer limits are typically not defined for commodity PP; any such limits for this item are Not specified for this item; refer to CoA/Spec Sheet.
Reaction and Applications
Item-specific (from Product Data)
Manufacturer Applications: Not specified for this item; refer to CoA/Spec Sheet.
Relevant applications for “Polypropylene for Melt Volume Flow Rate” (literature/general)
MVR/MFR benchmarking: Used as a test material to establish or verify melt flow indexer performance at 230 °C/2.16 kg (ISO 1133-1, ASTM D1238).
Processability studies: Correlating MVR with molecular weight and polydispersity for extrusion/injection parameters; monitoring lot-to-lot consistency after compounding or aging.
Thermal stabilization assessment: Comparing MVR drift during multiple passes or prolonged residence to evaluate antioxidant packages and processing stability.
Crystallinity control: Nucleating agents or thermal history alter crystallization kinetics and thus apparent flow; xylene soluble/insoluble fractionation and DSC are complementary to MVR for structure–property mapping.
Analytical workflows: High-temperature GPC for molecular weight distribution; FTIR for tacticity (methyl rocking bands), 13C NMR for triad tacticity; DSC/TGA for melting/degradation metrics.
Practical tips (literature)
Preconditioning: Drying at ~60–80 °C under vacuum may improve repeatability by removing volatiles/fines, though moisture is not typically critical for PP.
Test consistency: Standardize preheat time, piston dwell, and purging to mitigate shear/thermal history effects on MVR. Use antioxidant-containing test solvents (for HT-GPC) and nitrogen blankets when heating PP solutions.
Reaction Conditions
General conditions for PP modification (literature; not specifications for this item)
Radical grafting (e.g., maleic anhydride): Melt processing at 170–210 °C with ~0.05–0.5 wt% organic peroxide initiator; residence times 1–5 min in an extruder; nitrogen blanket advised. Post-extraction removes homopolymerized anhydride.
Peroxide crosslinking: 160–200 °C with dialkyl peroxide; monitor gel content; stabilizers to mitigate β-scission.
Surface oxidation: Corona/plasma treatment at ambient temperature, exposure seconds to minutes; aim for surface energy >40 mN/m; effects can age—overcoat or use promptly.
Solution dissolution for HT-GPC: Dissolve at 140–160 °C in TCB or o-dichlorobenzene with ~0.025–0.1% BHT; dissolution time 30–120 min with gentle agitation; filter hot through 0.6–1 µm PTFE or stainless filters.
Xylene soluble/insoluble fractionation (XS/XI): Reflux in xylene (~135 °C) for 30–60 min, filter hot; quantify insoluble fraction to assess crystallinity and tacticity.
GHS Classification / Signal Word / H-Statements / Pictograms: Not specified for this item; refer to SDS.
General safety information (literature; defer to SDS for authoritative guidance)
Classification: Generally considered an inert, nonhazardous polymer in solid form. Not classified as hazardous under many systems when supplied as pellets/powder, but always consult SDS.
Combustibility: Combustible thermoplastic; burns with a sooty flame. Avoid ignition sources. Firefighting media: water spray, foam, dry chemical; thermal decomposition may release hydrocarbons and carbon monoxide.
Dust hazard: Fine powders can present a nuisance dust and potential dust explosion risk; employ appropriate dust control and grounding during pneumatic transfer.
Thermal processing: At elevated temperatures (e.g., extrusion), ensure adequate ventilation to avoid exposure to fumes; prevent overheating and stagnation which accelerates oxidative chain scission.
Incompatibilities: Strong oxidizers; halogenating agents. Avoid prolonged UV exposure without stabilizers (photo-oxidation and embrittlement).
Handling PPE: Safety glasses, lab coat, appropriate gloves for handling hot materials; use heat-resistant PPE for melt-processing.
First aid overview: For thermal burns from molten polymer, cool with water—do not attempt to remove solidified polymer from skin; seek medical attention. For dust inhalation, move to fresh air. Refer to SDS for full first-aid measures.
Solvent Selection
Applicability
As a solid polyolefin, PP is not used as a solvent. This section focuses on solvent compatibility for processing, dissolution for analysis, and cleaning.
Solvent compatibility (literature/general)
Nonpolar character: Resistant to water, alcohols, dilute acids/bases. Swells in nonpolar hydrocarbons (hexane, heptane) and aromatics (toluene) at elevated temperature.
Dissolution: Requires high-boiling solvents and heat: 1,2,4-trichlorobenzene (TCB), tetralin, or decalin at ~130–160 °C; xylene at reflux for fractionation/crystallinity studies (e.g., xylene soluble/insoluble test).
Analytical GPC/HT-SEC: TCB (135–160 °C) and o-dichlorobenzene are widely used eluents with antioxidant (e.g., BHT) to suppress oxidative chain scission during analysis.
Cleaning considerations: Hydrocarbon solvents effectively remove PP processing residues while not dissolving bulk PP at ambient temperature; avoid strong oxidizers/chlorinated solvents contact with hot PP if degradation is a concern.
When to choose PP vs alternatives
For melt rheology and MVR benchmarking, PP is a standard nonpolar, semicrystalline matrix. Alternatives such as polyethylene (PE) show different melting and flow behavior; polystyrene offers amorphous flow references but distinct polarity and Tg-driven rheology.
Storage and Reconstitution
Item-specific (from Product Data)
Storage Conditions: Room temperature.
Shipped In: Normal.
General guidance (literature/general)
Storage environment: Keep in a cool, dry place away from direct sunlight and UV sources to prevent photo-oxidation. Maintain in sealed, clean containers to avoid dust contamination.
Oxidative stability: If long-term storage is expected, inert packaging (foil bags) or addition of stabilizers in the formulation helps preserve properties; exact stabilizer content for this item is Not specified for this item; refer to CoA/Spec Sheet.
Reconstitution: Not applicable—solid thermoplastic supplied ready to use. For analytical dissolution, follow high-temperature dissolution protocols under inert atmosphere to avoid oxidative degradation.
Handling before testing: For MVR/MFR, precondition material by equilibrating to lab temperature; optional drying at 60–80 °C under vacuum can remove volatiles/fines for improved repeatability.
Shelf life: Not specified for this item; refer to CoA/Spec Sheet.
Structure and Identity
Item-specific (from Product Data)
Product: Polypropylene for Melt Volume Flow Rate (SKU: P1522964)
CAS: 9003-07-0
PubChem CID: 76958
InChIKey: 247179 (as provided; polymers typically lack a definitive InChIKey)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
General polymer identity (literature/typical)
Polymer type: Polypropylene (PP), a saturated hydrocarbon polyolefin derived from propene.
Repeat unit: –[CH2–CH(CH3)]– (empirical repeat formula C3H6).
Tacticity: Exists as isotactic, syndiotactic, or atactic sequences; isotactic PP predominates in commercial grades for higher crystallinity and melt strength.
Structural features: Nonpolar, semicrystalline thermoplastic. 2D depiction consists of a carbon backbone with pendant methyl groups on every other carbon; absence of heteroatoms and functionality.
Topology: High molecular weight linear chains, possible low levels of chain branching depending on process (Ziegler–Natta vs. metallocene catalysis).
Synthetic Utility
Applicability
PP is not a small-molecule reagent but can be a substrate for polymer-chemistry transformations and surface functionalization.
Transformations (literature/general)
Graft modification: Free-radical grafting (e.g., maleic anhydride) initiated by peroxides during melt processing to introduce polar functionality (PP-g-MA) for compatibilization in blends and adhesion to polar substrates.
Surface activation: Corona discharge, plasma, or UV/ozone oxidizes the surface to generate hydroxyl/carbonyl groups, improving wettability and adhesion for coatings, printing, or biomolecule attachment.
Crosslinking: Peroxide-induced crosslinking (silane or organic peroxides) can raise heat resistance; tradeoff with recyclability.
Deuteration or labeling: Limited to specialty syntheses; not typical for commodity PP.
Retrosynthetic/analytical aspects
Tacticity control arises from catalyst design (Ziegler–Natta vs. metallocene). Analytical 13C NMR triad distributions inform microstructure; DSC and WAXD quantify crystallinity.
Target Specificity
Not applicable
This product is a polymer material, not a biological targeting reagent (e.g., antibody, ligand, or probe). No antigen/epitope specificity, clone, isotype, or species reactivity applies.
Utilizziamo i cookie per garantire il corretto funzionamento del sito web e, ove consentito, per migliorare la tua esperienza. Puoi gestire le tue preferenze in qualsiasi momento nelle Impostazioni. Per saperne di più, consulta la nostra Cookie Policy.
Desidera che le inviamo un messaggio quando avremo sconti disponibili?
Ricordamelo più tardi
Grazie! Controlli la sua casella di posta per confermare.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.