Determine the necessary mass, volume, or concentration for preparing a solution.
BioReagent,for microscopy,Biological Stain Biological Stain,BioReagent,per la microscopia for sensitive chromatographic and analytical workflows requiring minimal baseline interference.
Protected from light,Store at -20°C Ships Ice chest + Ice pads Check lot-specific COA for exact specifications.
SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.
Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.
Reactive oxygen species (ROS) include superoxide anion, hydrogen peroxide, and their downstream products such as peroxides and hydroxyl derivatives. ROS are involved in cell growth and proliferation, development and differentiation, senescence and apoptosis, as well as many physiological and pathological processes. The ROS Assay Kit is designed for ROS detection using a fluorescent probe. This kit employs a red fluorescent probe to detect ROS in various animal and plant samples. The maximum excitation/emission wavelengths of the red fluorescent ROS probe are 510/610 nm.
Intracellular ROS levels can be determined by detecting the fluorescence intensity. ROS content and changes in living cells can be evaluated based on fluorescence generation, which can be directly observed by flow cytometry or fluorescence microscopy. This is a classic method for ROS detection in tissues or living cells.The kit provides Rosup, a positive control reagent for ROS detection. Rosup is a mixture at a concentration of 50 mg/mL. As a positive inducer of ROS, it allows accurate analysis of actual ROS levels according to fluorescence signal intensity.
This kit is only suitable for ROS detection in cells and fresh tissue samples, and cannot be used for frozen tissue samples. It features low background, high sensitivity, wide linear range and ease of use.
Precautions
1. After probe loading, residual unincorporated probe must be thoroughly washed away, otherwise high background will occur.
2. The typical working concentration of positive control Rosup is 100 μM (recommended range: 100–400 μM, depending on cell type). A significant increase in ROS levels can usually be observed 0.5–4 h after stimulation. The effect of the ROS positive control may vary considerably among different cell lines. If no ROS elevation is observed within 30 min of stimulation, extend the induction time or increase the Rosup concentration appropriately. If ROS increases too rapidly, shorten the induction time or reduce the concentration accordingly.
3. For some specific cell types, if high fluorescence is also observed in unstimulated negative control cells, dilute the probe at 1:2000 to 1:5000 to a final concentration of 2–5 μM. Probe loading time can also be adjusted from 15 to 60 min as needed.
4. The ROS positive control (Rosup) is only used for positive control samples and does not need to be added to every test sample.
5. After probe loading and washing away residual probe, excitation and emission scanning can be performed to verify proper probe loading.
6. Minimize the interval between probe loading and measurement (excluding stimulation time) to reduce potential errors.
7. For your safety and health, please wear a lab coat and disposable gloves during operation.
8. For quantitative analysis, a standard curve must be established. Measure fluorescence values oxidized by different concentrations of H₂O₂ to plot a standard curve with H₂O₂ concentration as the X-axis and fluorescence intensity as the Y-axis to obtain a regression equation. The corresponding X value from the sample fluorescence (Y value) is the ROS concentration.
9. Some cells tend to detach after probe loading, leading to cell loss during washing. To avoid this, seed cells at double the usual density so that cells form tight junctions and adhere firmly, resulting in higher fluorescence intensity in test groups. In addition, this probe is highly sensitive; a lower working concentration (1–2 μM) is sufficient. Higher concentrations may cause non-specific staining. The probe is unstable and its background fluorescence increases once oxidized, so the working solution should be prepared fresh immediately before use.
10. The staining solution is supplied in DMSO. It may solidify at low temperatures and adhere to tube or pipette tip walls. Ensure it is fully thawed to liquid form, centrifuged to the bottom of the tube, then opened before use.
Self-provided equipment and reagents:
Confocal laser scanning microscope, fluorescence spectrophotometer or fluorescence microplate reader (excitation: 488–535 nm, emission: 610 nm)
Centrifuge
pipettes
PBS buffer/HBSS (phenol red-free)
Protein quantification assay kit
Protocol
1. Sample Preparation
(1) Wash freshly isolated tissue samples with PBS.
(2) Accurately weigh 50 mg of tissue, add 1 mL of Homogenization Buffer A, and homogenize thoroughly using a glass homogenizer.
(3) Centrifuge at 100×g for 3 min at 4℃. Discard the pellet and collect the supernatant.
2. Sample Assay
(1) Add 200 μL of tissue homogenate supernatant and 2 μL of DHE probe to each well of a 96-well plate. Mix well by pipetting.
(2) Incubate at 37℃ for 30 min in the dark.
(3) Measure fluorescence intensity using a fluorescence microplate reader at excitation wavelength 488–535 nm and emission wavelength 610 nm.
3. Protein Quantification
(1) Take another 50 μL of homogenate supernatant and dilute approximately 30-fold with PBS.
(2) Transfer 100 μL for protein quantification.
4. Data Analysis
Express tissue ROS levels as fluorescence intensity per milligram of protein.
| Item No. | Appearance | Components | 200 T | Storage |
| R1520936A | Liquid | Buffer A | 200 mL | -20℃. |
| R1520936B | Liquid | Red Fluorescent Dye (5 mM) | 2×0.2 mL | -20℃. Store in the dark. |
| R1520936C | Liquid | Rosup positive control | 2×1 mL | -20℃. |
Comprehensive hazard, handling, storage, and regulatory compliance document.
Download SDS →Lot-specific quality data. Enter your lot number to retrieve the exact COA.
Look up COA →Full quality attributes and acceptance criteria for this grade.
View spec sheet →Find and download the COA for your product by matching the lot number on the packaging.
| Lot Number | Certificate Type | Data | Oggetto |
|---|---|---|---|
| Certificate of Analysis | May 14, 2026 | R1520936 |
Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.
View BioReagent grade guide → View Biological Stain grade guide → View for Microscopy grade guide →