Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile) Coating Protocol

Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile) is a ready-to-use cationic polymer solution designed to coat cell culture surfaces and significantly improve adhesion of neurons, primary cells, and other anchorage-dependent cell types.

Product SKU
P1508963
Concentration
0.1 mg/mL (1×, ready-to-use)
Sterility
Sterile (suitable for cell culture use)
Storage Temperature
-20°C
Light Sensitivity
Store in the dark
Application
Cell culture surface coating to enhance cell adhesion

Introduction and Principle

Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile) (P1508963) is a cationic polymer solution widely used in cell biology to improve cell attachment to culture substrates. Poly-L-lysine (PLL) carries multiple positively charged amino groups at physiological pH, which electrostatically interact with the negatively charged cell membrane surface and with anionic groups on glass or tissue-culture-treated plastic. This non-covalent electrostatic interaction creates a more favorable microenvironment for initial cell attachment and subsequent spreading.

The 1× concentration at 0.1 mg/mL is a widely adopted working concentration suitable for most standard coating applications, including coverslips, multiwell plates, flasks, and slides. The sterile formulation ensures compatibility with aseptic cell culture workflows without additional filtration steps.

Materials Required

Before beginning the coating procedure, ensure the following materials are available:

  • Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile) (P1508963)
  • Sterile tissue-culture vessels (plates, flasks, coverslips, or slides)
  • Sterile water or phosphate-buffered saline (PBS, pH 7.4) for rinsing
  • Biosafety cabinet or laminar flow hood
  • Aspiration device or sterile pipettes
  • Incubator (37°C) or benchtop surface for room-temperature incubation

Note: All procedures should be performed under aseptic conditions to maintain sterility of the coated surfaces prior to cell seeding.

Step-by-Step Coating Procedure

Perform all steps inside a biosafety cabinet to maintain aseptic conditions.

  1. Thaw and equilibrate: Remove Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile) (P1508963) from -20°C storage and allow it to thaw completely at room temperature or at 4°C. Gently mix by inversion before use.
  2. Apply solution: Add a sufficient volume of the solution to cover the culture surface completely. As a general guideline, use approximately 0.1–0.2 mL/cm² of surface area. Adjust volume as needed for your specific vessel format.
  3. Incubate: Incubate the coated vessel at 37°C for a minimum of 1 hour, or at room temperature for 2 hours. For enhanced coating of glass surfaces, overnight incubation at room temperature may improve attachment.
  4. Aspirate: Carefully aspirate the poly-L-lysine solution. The solution may be collected and stored at 4°C for reuse within a short period, provided sterility is maintained.
  5. Rinse: Wash the coated surface twice with sterile water or sterile PBS (pH 7.4) to remove unbound polymer. Allow rinses to contact the surface for at least 1 minute each.
  6. Dry or seed immediately: Either allow the surface to air-dry completely in the biosafety cabinet with the lid slightly open, or proceed immediately to cell seeding with your desired culture medium.

Important: Do not allow the coated surface to dry out completely if cells are to be seeded immediately after rinsing; add culture medium promptly after the final rinse.

Storage, Handling, and Quality Notes

Storage conditions: Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile) (P1508963) must be stored at -20°C and protected from light. Exposure to light may cause degradation of the solution over time. Avoid repeated freeze-thaw cycles; aliquoting into single-use volumes upon first thaw is strongly recommended to preserve product integrity.

Handling precautions: Always handle the solution inside a biosafety cabinet when intended for sterile cell culture applications. Use sterile pipette tips and vessels at all times. Discard any aliquots showing visible particulates, cloudiness, or discoloration.

Shelf life: Refer to the expiration date printed on the product label. Improper storage (e.g., storage above -20°C or exposure to light) may reduce coating efficacy and should be flagged for review.

Troubleshooting

If cells fail to adhere adequately after coating, consider the following common causes and corrective actions:

  • Insufficient incubation time or temperature: Ensure the coated surface is incubated for the recommended duration. Extending incubation time or switching to 37°C may improve coating density.
  • Inadequate rinsing: Residual unbound poly-L-lysine can be cytotoxic. Confirm that at least two thorough rinses with sterile water or PBS are performed.
  • Surface incompatibility: Some ultra-low-attachment or hydrophobic surfaces may not coat efficiently. Standard tissue-culture-treated plastic or glass is recommended for optimal results with Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile).
  • Degraded product: Confirm the product has been stored at -20°C and protected from light. Use a fresh aliquot if coating performance is suboptimal.
  • Cell health issues: Poor cell viability at seeding can mimic poor adhesion. Verify cell viability prior to seeding on PLL-coated surfaces.

Frequently asked questions

What is the recommended incubation time and temperature for Poly-L-lysine Solution coating?

For most applications, incubate the coated surface at 37°C for a minimum of 1 hour or at room temperature for approximately 2 hours. For glass surfaces or demanding applications such as primary neuron culture, overnight incubation at room temperature may further improve cell attachment.

Can Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile) be reused after coating?

The aspirated Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile) (P1508963) may be collected and stored at 4°C for short-term reuse, provided aseptic technique is maintained throughout. However, repeated reuse is not recommended as it may reduce coating efficacy and risk contamination. Aliquoting the stock into single-use volumes before first use is the preferred approach.

Why must Poly-L-lysine Solution be stored at -20°C and protected from light?

Storage at -20°C prevents degradation of the poly-L-lysine polymer and maintains the sterility and biological activity of the solution over time. Light exposure can cause photodegradation of the formulation, reducing its effectiveness as a cell adhesion coating agent. Always keep the product in the dark and avoid repeated freeze-thaw cycles by aliquoting upon first thaw.

Is rinsing with sterile water necessary after the poly-L-lysine coating step?

Yes, rinsing is a critical step. Unbound poly-L-lysine remaining on the surface can be cytotoxic to cells. At least two rinses with sterile water or sterile PBS (pH 7.4) are recommended to remove excess polymer before cell seeding. Skipping or inadequate rinsing is a common cause of poor cell viability after plating on PLL-coated surfaces.

References

  1. Mazia, D., Schatten, G., & Sale, W. (1975). Adhesion of cells to surfaces coated with polylysine: applications to electron microscopy. Journal of Cell Biology, 66(1), 198–200.
  2. Bhattacharya, R., et al. General methods for coating cell culture substrates with poly-L-lysine to enhance cell adhesion. (General laboratory reference — specific citation details to be verified.)

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Categories: Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Cite this article

Aladdin Scientific. "Poly-L-lysine Solution (1×, 0.1 mg/mL, Sterile) Coating Protocol" Aladdin Knowledge Base, updated 25 nov. 2026. https://www.aladdinsci.com/us_fr/faqs/poly-l-lysine-solution-1x-0-1-mg-ml-sterile-coating-protocol-en.html
Was this article helpful? Yes No 2 out of 4 found this helpful

Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?

Me rappeler plus tard

Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.

Oups ! Les notifications sont désactivées.