Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Recombinant STAT1 Antibody: Protocol & Application Guide

Recombinant STAT1 Antibody is a high-specificity immunoreagent designed to detect endogenous STAT1 protein across multiple experimental platforms, supporting research into JAK-STAT signaling, interferon responses, and immune regulation.

Antibody Type
Recombinant antibody
Target Protein
STAT1 (Signal Transducer and Activator of Transcription 1)
Recommended Applications
Western blot (WB), Immunofluorescence (IF)
Storage
Store at -20°C; avoid repeated freeze-thaw cycles

Background: STAT1 Biology and Antibody Overview

STAT1 (Signal Transducer and Activator of Transcription 1) is a critical transcription factor in the JAK-STAT signaling pathway. Upon stimulation by interferons (IFN-α, IFN-β, and IFN-γ) and various cytokines, STAT1 is phosphorylated, dimerizes, and translocates to the nucleus to regulate the expression of genes involved in immune defense, cell proliferation, and apoptosis.

Recombinant STAT1 Antibody (Ab326909) is an affinity-purified recombinant antibody engineered for consistent lot-to-lot performance. Its recombinant nature ensures superior batch reproducibility compared to conventional hybridoma-derived antibodies, making it particularly suitable for quantitative and longitudinal studies.

This antibody is intended for research use only and is not approved for diagnostic or therapeutic applications.

Sample Preparation

Proper sample preparation is essential to obtain reliable results with Recombinant STAT1 Antibody.

  • Cell lysates: Harvest cells at the desired confluency. Wash twice with ice-cold PBS, then lyse in RIPA buffer supplemented with protease inhibitor cocktail and phosphatase inhibitors (if detecting phospho-STAT1). Centrifuge at 12,000 × g for 15 min at 4°C and collect the supernatant.
  • Tissue lysates: Homogenize fresh or snap-frozen tissue in lysis buffer on ice. Centrifuge as above. Protein quantification by BCA or Bradford assay is recommended before proceeding.
  • For immunofluorescence: Seed cells on glass coverslips or chambered slides. After treatment, fix with 4% paraformaldehyde (10–15 min, room temperature) and permeabilize with 0.1–0.3% Triton X-100 (5–10 min). Block with 5% normal serum or 1% BSA in PBS for 1 hour prior to antibody incubation.

All samples should be maintained on ice during processing to minimize protein degradation and dephosphorylation.

Step-by-Step Protocol

Western Blot (WB) Protocol

  1. Separate 20–40 µg of total protein per lane by SDS-PAGE (8–10% gel recommended for STAT1, ~91 kDa).
  2. Transfer proteins to PVDF or nitrocellulose membrane.
  3. Block membrane with 5% non-fat dry milk or 5% BSA in TBST for 1 hour at room temperature.
  4. Incubate with Recombinant STAT1 Antibody at the manufacturer-recommended dilution (refer to the product datasheet for the validated dilution range) overnight at 4°C with gentle agitation.
  5. Wash 3 × 10 min with TBST.
  6. Incubate with appropriate HRP-conjugated secondary antibody for 1 hour at room temperature.
  7. Wash 3 × 10 min with TBST, then detect signal using ECL substrate.

Immunofluorescence (IF) Protocol

  1. After blocking (see Sample Preparation), incubate fixed and permeabilized cells with Recombinant STAT1 Antibody at the recommended dilution overnight at 4°C.
  2. Wash 3 × 5 min with PBS.
  3. Incubate with fluorophore-conjugated secondary antibody for 1 hour at room temperature, protected from light.
  4. Wash 3 × 5 min with PBS.
  5. Counterstain nuclei with DAPI if required. Mount coverslips and image by confocal or epifluorescence microscopy.

Note: Exact working dilutions should be validated per individual experimental conditions using the product datasheet as a starting reference.

Storage, Stability, and Handling

To maintain optimal activity and specificity of Recombinant STAT1 Antibody, observe the following guidelines:

  • Short-term storage (up to 1 month): Store at 4°C.
  • Long-term storage: Store at -20°C. For extended storage, aliquoting is strongly recommended to avoid repeated freeze-thaw cycles, which can compromise antibody integrity and performance.
  • Avoid: Exposure to direct light, repeated freeze-thaw cycles, and temperatures above 25°C during handling.
  • Carrier protein: If the antibody formulation contains BSA or glycerol, check the datasheet to ensure compatibility with downstream labeling applications.
  • Sterility: Handle under aseptic conditions if the antibody will be used in cell-based assays to prevent contamination.

Shelf life and exact buffer composition should be confirmed on the product datasheet supplied with each lot.

Troubleshooting

The following table addresses common issues encountered when using Recombinant STAT1 Antibody:

ProblemPossible CauseSuggested Solution
No signal detectedAntibody dilution too high; insufficient antigen; poor transferOptimize antibody concentration; increase protein loading; verify transfer efficiency with Ponceau S staining
High backgroundInsufficient blocking; antibody concentration too high; cross-reactivity of secondary antibodyIncrease blocking time/concentration; reduce primary antibody concentration; use a pre-adsorbed secondary antibody
Non-specific bandsPartial protein degradation; excess secondary antibodyAdd protease inhibitors during lysis; titrate secondary antibody; include appropriate negative controls
Weak IF signalOver-fixation; inadequate permeabilization; photobleachingReduce fixation time; optimize detergent concentration; protect slides from light at all steps

Frequently asked questions

What applications is Recombinant STAT1 Antibody (Ab326909) validated for?

The Recombinant STAT1 Antibody is recommended for Western blot (WB) and immunofluorescence (IF) applications. For confirmed validated applications and species reactivity, always consult the official product datasheet provided with Ab326909.

What is the expected molecular weight of STAT1 detected by this antibody?

STAT1 has a predicted molecular weight of approximately 87–91 kDa, though the observed band may appear slightly higher or lower depending on post-translational modifications such as phosphorylation. Always refer to the product datasheet for lot-specific information when using Recombinant STAT1 Antibody.

Why should I choose a recombinant antibody over a conventional monoclonal antibody for STAT1 detection?

Recombinant antibodies such as Recombinant STAT1 Antibody are produced from a defined genetic sequence, ensuring exceptional batch-to-batch consistency and eliminating the variability inherent to hybridoma cell lines. This makes them ideal for reproducible quantitative assays, long-term studies, and experiments requiring stringent standardization.

How should I store Ab326909 to maximize shelf life?

Store Ab326909 at -20°C for long-term storage. Aliquot the antibody upon first receipt to avoid repeated freeze-thaw cycles. For short-term use within one month, storage at 4°C is acceptable. Protect from light and do not store at room temperature for extended periods.

References

  1. Darnell JE Jr, Kerr IM, Stark GR. Jak-STAT pathways and transcriptional activation in response to IFNs and other extracellular signaling proteins. Science. 1994;264(5164):1415-1421. PMID:8197455
  2. Stark GR, Darnell JE Jr. The JAK-STAT pathway at twenty. Immunity. 2012;36(4):503-514. PMID:22520844

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Categories: Technical Articles: Reagent Chemistry, Synthesis & Bioscience Guides

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

Cite this article

Aladdin Scientific. "Recombinant STAT1 Antibody: Protocol & Application Guide" Aladdin Knowledge Base, updated 28 nov. 2026. https://www.aladdinsci.com/us_fr/faqs/recombinant-stat1-antibody-protocol-application-guide-en.html
Was this article helpful? Yes No 5 out of 8 found this helpful

Souhaitez-vous que nous vous envoyions un message lorsque des réductions seront disponibles?

Me rappeler plus tard

Merci ! Veuillez vérifier votre boîte de réception e-mail pour confirmer.

Oups ! Les notifications sont désactivées.