Peroxide Value Assay Kit (Micro Method)

Cat. No.: P1522268
注文可能
グレード&純度 BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
サイズ
USA
ドイツ (EU)*
価格
個数
96T
P1522268-96T
受注生産 · 8~12週間
$139.90
Enter a quantity for the sizes you want to add.
🧪
このグレードを選ぶ理由

BioReagent BioReagent ベースライン干渉を最小限に抑える必要がある、感度の高いクロマトグラフィーおよび分析ワークフロー向け。

🌡

保管・配送

Store at 2-8°C,Protected from light Wet ice に出荷。正確な仕様については、ロット固有の COA をご確認ください。

📋

品質書類

SDS、COA、データシート、仕様書をダウンロードできます。ロット固有の COA はロット番号検索で入手可能です。

📚

文献的裏付け

クロマトグラフィー、有機合成、クロスカップリング反応に関する 0 件の査読済み論文で引用されています。

概要

Peroxide value is an important indicator of the degree of oxidation of oils, fats, and fatty acids, usually expressed as millimoles of active oxygen per kilogram of sample. It is used to determine whether food has deteriorated due to oxidation and is a key parameter for evaluating food hygiene quality. The higher the peroxide value, the more severe the rancidity of the oil, and the lower the quality and safety of the food.

Principle: Peroxides in the sample oxidize ferrous ions (Fe²⁺) to ferric ions (Fe³⁺). Ferric ions react with thiocyanate to form an orange-red ferric thiocyanate complex. The peroxide value can be determined by measuring the absorbance of this complex at 500 nm.

Contents & Storage:

Component No.Component NameAppearance96TStorage
P1522268AReagent ILiquid1EA2-8℃. Store in the dark
P1522268BReagent IIPowder1EA2-8℃. Store in the dark
P1522268CStandardLiquid2mL2-8℃. Store in the dark

Precautions for Reagent Use:

1.Before opening Reagent II, ensure the powder has settled to the bottom (shake manually). When using, dissolve in 1.2 mL of pure water. The storage period is the same as the kit's shelf life.

2.Extraction solution must be prepared by the user. Pure methanol (analytical grade or higher, purity ≥98%) is recommended.

Experimental Equipment:

Mortar (homogenizer), ice box (ice machine), benchtop centrifuge, adjustable pipette, 96-well plate, centrifuge tubes, microplate reader, pure methanol, distilled water (deionized water or ultrapure water are all acceptable).

Measurement Procedure:

It is recommended to first select 1–3 samples with large differences (e.g., different types or groups) for a preliminary experiment to familiarize yourself with the procedure and determine or adjust the sample concentration based on the preliminary results, so as to avoid unnecessary waste of samples or reagents.

1. Sample Extraction:

① Animal and plant tissue samples:

Take approximately 0.1 g of tissue, add 1 mL of extraction solution, and homogenize in an ice bath. Centrifuge at 12,000 rpm at 4°C for 10 min. Collect the supernatant and keep it on ice until measurement.

② Liquid samples:

Measure directly. If turbid, centrifuge and use the supernatant for detection.

③ Bacterial/cell samples:

First collect the bacteria or cells into a centrifuge tube, centrifuge, and discard the supernatant. Take 5 million bacteria or cells, add 1 mL of extraction solution, and homogenize in an ice bath (various common electric homogenizers may be used); alternatively, use an ultrasonic disruptor to sonicate the bacteria or cells in an ice bath (power 200 W, sonication 3 s, interval 10 s, repeat 30 times). Centrifuge at 12,000 rpm at 4°C for 10 min and collect the supernatant for measurement.

[Note]: Cell samples may also be lysed with a lysis buffer for subsequent detection; the lysis method should follow the lysis buffer's operating instructions.

2. Detection Steps:

① Preheat the microplate reader for 30 min (waiting for the instrument to complete its self-check procedure is also acceptable), and set the wavelength to 500 nm.

② Bring all reagents to room temperature, and add them sequentially to EP tubes as shown in the table below:

Reagent (μL)Assay TubeBlank Tube (once only)
Sample50—
Pure methanol900950
Reagent I1010
Reagent II1010

Mix well and incubate at room temperature for 5 min. Transfer 200 μL to a 96-well plate and measure the absorbance (A) at 500 nm.ΔA = Aassay − Ablank.

[Note]: 

1. If the value of the assay tube (A) exceeds 1.8, the sample may be diluted before measurement; the dilution factor D should be substituted into the calculation formula.

2.If ΔA is less than 0.01, the sample mass W may be increased; the changed W must be substituted into the formula for recalculation.

Result Calculation:

Standard curve equation: y = 0.0055x − 0.0165, where x is the standard concentration (μg/mL) and y is ΔA.

1.Calculation based on mass:

Peroxide value (μg/g) = [(ΔA + 0.0165) ÷ 0.0055 × V₁] ÷ (W × V₁ ÷ V) × D= 181.82 × (ΔA + 0.0165) ÷ W × D

2.Calculation based on protein content:

Peroxide value (μg/mg prot) = [(ΔA + 0.0165) ÷ 0.0055 × V₁] ÷ (Cpr × V₁ ÷ V) × D= 181.82 × (ΔA + 0.0165) ÷ Cpr × D

3.Calculation based on liquid volume:

Peroxide value (μg/mL) = [(ΔA + 0.0165) ÷ 0.0055] × D = 181.82 × (ΔA + 0.0165) × D

4.Calculation based on bacterial/cell density:

Peroxide value (μg/10⁴ cells) = [(ΔA + 0.0165) ÷ 0.0055 × V₁] ÷ (V₁ ÷ V × 500) × D= 181.82 × (ΔA + 0.0165) ÷ 500 × D

W: sample mass, g;

V: extraction solution volume, 1 mL;

V₁: sample volume added, 0.05 mL;

500: total number of bacteria or cells, in units of 10⁴;

D: dilution factor (1 if undiluted);

Cpr: protein concentration of the supernatant, mg/mL.

Appendix: Standard Curve Preparation Procedure:

1.The standard curve is optional. Users may prepare a standard curve according to experimental needs, or directly use the calculation formula in the instructions for result calculation.

2.The standard stock solution concentration is 1000 μg/mL. Dilute the stock solution with pure methanol to prepare six concentration gradients of standards, for example: 0, 20, 40, 60, 80, 100 μg/mL. The standard concentrations may also be adjusted according to actual samples.

3.Refer to the following table for standard dilution:

Pipette 100 μL of the standard stock solution, add 900 μL of pure methanol, and mix well to obtain a 100 μg/mL standard diluent for later use.
Standard concentration (μg/mL)020406080100
Standard diluent (μL)04080120160200
Pure methanol (μL)20016012080400
Mix each standard tube well and set aside for use.

4.Operate according to the assay tube loading table. Based on the results, subtract the absorbance at 0 concentration from the absorbance at each concentration, and construct the standard curve through the zero point.

Reagent (μL)Standard Tube (A)Zero Concentration Tube A0 (once only)
Standard50—
Pure methanol910960
Reagent II1010
Mix well and incubate at room temperature for 5 min. Transfer 200 μL to a 96-well plate and measure the absorbance (A) at 500 nm. ΔA = Astandard tube − A0 concentration tube.

仕様

仕様と純度
BioReagent
等級
BioReagent
アプリケーション
Cell Metabolism
サンプルタイプ
動物および植物の組織, 細胞, 細菌
検出方法
Colorimetric Method
定量的
Quantitative
Detection instrument
Microplate reader
Detection wavelength
500nm
感度
Light-sensitive
保管と配送
保管条件
Store at 2-8°C,Protected from light
入荷
Wet ice
安定性と保管
Store at 2-8℃ long term (12 months). Store in the dark.
Contents & Storage
Component No.Component NameAppearance96TStorage
P1522268AReagent ILiquid1EA2-8℃. Store in the dark
P1522268BReagent IIPowder1EA2-8℃. Store in the dark
P1522268CStandardLiquid2mL2-8℃. Store in the dark

ドキュメント

📋 安全データシート(SDS)

危険性、取扱い、保管、および規制遵守を網羅した包括的な文書。

<<<<<<< HEAD SDS をダウンロード → ======= SDS をダウンロード → >>>>>>> release248-p3

✅ 分析証明書(COA)

ロット固有の品質データ。ロット番号を入力して、正確な COA を取得してください。

COA を検索 →

📊 データシート

製品仕様と用途のクイックリファレンス概要。

データシートを見る →

🔬 仕様書

このグレードの完全な品質特性と合格基準。

仕様書を見る →

詳細データ

証明書(CoA、COO、BSE/TSEと分析図)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
ソリューション計算機
レビュー

顧客レビュー

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.