Chloride Ion Selective Electrode Solutions - Fill Solution

Cat. No.: I123779
Disponível para encomenda
GRADE & PURITY Fill Solution
Synonyms
Chloride ion electrode solution
Storage
Room temperature
Shipped In
Normal
★
Size
USA
Alemanha (EU)*
Price
Qty
125ml
I123779-125ml
2 Em stock
—

87,90US$

103,90US$
Gravar 16,00 US$ (15.40%)
Enter a quantity for the sizes you want to add.
🧪
Why this grade

Fill Solution for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Room temperature Ships Normal Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Specifications

Sinónimos
Chloride ion electrode solution
Especificações e pureza
Fill Solution
Condições de armazenamento de armazenamento
Room temperature
Enviado em
Normal

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificados(CoA,COO,BSE/TSE e Mapa de Análise)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate TypeDataItem
K2103016Certificate of AnalysisAug 04, 2026 I123779
F1511022Certificate of AnalysisApr 14, 2022 I123779
FAQs e artigos
Calculadoras de soluções
Revisões

Avaliações dos Clientes

Application Protocols

General chloride ISE calibration and measurement guidelines (literature/general). Adapt to your laboratory SOP and the electrode manufacturer’s instructions.

  • Preparation

    • Bring all standards, ISA (if used), and samples to the same temperature.
    • Use clean Class A volumetric ware. Rinse electrode and vessels with a small volume of the standard to be used.
  • Calibration (example workflow)

    • Prepare a multi-point series bracketing your sample concentrations. Typical sets include at least three standards spanning 1–3 orders of magnitude (literature/general). Exact concentrations for this item: Not specified; refer to CoA/Spec Sheet.
    • Add ISA to standards and samples in the same proportion if required.
    • Measure potential from low to high concentration (or vice versa), allowing stabilization at each point.
    • Generate the calibration curve (mV vs log10[Cl−]); verify the slope approximates the theoretical value for your temperature (literature/general Nernstian behavior).
  • Sample measurement

    • Add the same ISA proportion as used for standards.
    • Immerse the electrode, stir gently, and record the stabilized potential.
    • Determine concentration from the calibration curve. For matrices with high ionic strength or complexing agents, use standard addition.
  • QC and maintenance

    • Check slope and intercept daily or per batch.
    • Store the electrode per manufacturer guidance and replace filling solution as specified.
    • Use fresh standards within labeled shelf life; avoid evaporation by minimizing open time.
Biological Roles

Not directly applicable to this product. These solutions are intended for electroanalytical calibration and operation of a chloride ISE rather than probing biological pathways. For context (literature/general), chloride is a major extracellular anion involved in membrane potential, acid-base balance, and transport; however, such biological roles are outside the scope of this product’s intended use.

Buffer Applications

These solutions are not general biological buffers. They are supplied for calibration/measurement with chloride ISEs. If an ISA is included, it functions to fix ionic strength and may contain buffering components to stabilize pH during measurement (literature/general). For standard biochemical buffering systems (e.g., phosphate, HEPES), refer to dedicated buffer products.

Green Alternatives

Compared with classical argentometric titrations using silver nitrate and chromate indicators, chloride ISE methods employ aqueous standards and avoid redox reagents that can generate silver‑containing waste.

  • Environmental perspective (literature/general):
    • ISE approach: Minimal hazardous reagent use; aqueous, low-to-moderate ionic strength solutions; reduced heavy‑metal waste.
    • Argentometric titration: Requires silver salts and often chromate indicators, producing metal- and hexavalent chromium–containing waste streams.
  • Tradeoffs:
    • ISEs can be sensitive to ionic strength, temperature, and interferents; careful calibration and ISA use are required.
    • Argentometric titration may offer robustness in certain matrices but with higher waste burdens and longer analysis time.

Comparison (literature/general):

  • Chloride ISE calibration/measurement
    • Pros: Rapid, field-deployable, low waste, continuous monitoring possible.
    • Cons: Requires stable standards/ISA, periodic re-calibration, electrode maintenance.
  • Silver nitrate titration
    • Pros: Well-established, can be accurate with good endpoint detection.
    • Cons: Generates silver waste, more sample/reagent consumption, less amenable to in-line monitoring.

Greening tips: Use reusable containers, prepare dilutions only as needed to reduce disposal, and segregate any silver-containing electrode/filling wastes for proper recycling.

Pharmaceutical Uses

No excipient or formulation role is specified for this item. In regulated environments, chloride ISE standards can support QC testing of water for injection or raw materials by potentiometric chloride determination (literature/general), but this product is designated For research use only. For cGMP/compendial testing, use documentation with appropriate traceability and verify against pharmacopeial methods.

Physical Properties

Item-specific physicochemical specifications are not provided in the product data and can vary with solution type and concentration.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Density: Typically near that of water and concentration-dependent (literature/general). Item-specific value: Not specified for this item; refer to CoA/Spec Sheet.
  • pH: Depends on formulation (neutral to buffered ranges are common for ISE solutions; literature/general). Item-specific value: Not specified for this item; refer to CoA/Spec Sheet.
  • Solubility: Fully miscible with water (general for aqueous standards/ISA/filling solutions). If concentrates are included, they are intended for dilution with deionized water (literature/general).
  • Boiling point, melting point, refractive index, conductivity: Concentration-dependent for electrolytes (literature/general). Item-specific values: Not specified for this item; refer to CoA/Spec Sheet.
  • Ionic strength and chloride activity: Critical parameters for ISE use (literature/general); actual values for the supplied solutions are Not specified for this item; refer to CoA/Spec Sheet.

Note: For analytical calibration, gravimetric or traceable molarity/ppm values and uncertainty are essential. Obtain the exact concentration, uncertainty, and traceability (e.g., to NIST or equivalent) from the product CoA.

Quality and Grades
  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
  • Traceability: For calibration solutions, traceability to national metrology standards (e.g., NIST) and a stated uncertainty are critical for compliance and data comparability (literature/general). Obtain these details from the item’s CoA.
  • What “ISE solutions” imply (general):
    • Calibration standards: Prepared gravimetrically/volumetrically to precise chloride concentrations with low total uncertainty; packaged to minimize evaporation and contamination.
    • Ionic Strength Adjuster (ISA): Formulated to fix ionic strength and complex interferents, improving Nernstian response and linearity.
    • Filling solution: Matched to the reference/electrode system to ensure stable junction potentials.
  • UV/organics/metal limits: Not specified for this item; refer to CoA/Spec Sheet.
  • Stabilizers/preservatives: Some aqueous standards include biocides or stabilizers to extend shelf life (literature/general). For this item: Not specified for this item; refer to CoA/Spec Sheet.

Recommendation: Consult the batch CoA for exact concentration, uncertainty, preparation method (gravimetric vs volumetric), shelf life, and traceability. Use unopened bottles for high‑accuracy work; record lot numbers for data integrity.

Reaction and Applications

This product is used for electroanalytical determination of chloride via potentiometry, not as a reagent for synthetic reactions.

  • Primary application (literature/general): Calibration and operation of chloride ion-selective electrodes for measurements in water analysis, environmental monitoring, food/beverage matrices, and process control.
  • Analytical principle: The chloride ISE exhibits a Nernstian potential proportional to the logarithm of chloride activity. Accurate calibration with standards of known chloride concentration is essential for drift-free quantitation.
  • Role of components:
    • Calibration standards: Define the slope and intercept of the electrode response curve.
    • Ionic Strength Adjuster (ISA): Fixes ionic strength and helps mitigate matrix effects and interference from complexing ions.
    • Filling solution: Stabilizes reference junction potential and maintains electrode responsiveness.
  • Practical considerations (literature/general):
    • Temperature influences Nernst slope; maintain constant temperature or use automatic temperature compensation and calibrate at the measurement temperature.
    • Avoid silver, mercury, or heavy metal contaminants that can complex or precipitate chloride.
    • For low‑level chloride, use plastic ware to minimize adsorption and pre-rinse with standard to condition surfaces.
  • Complementary methods: Argentometric titration (Mohr/Volhard), ion chromatography; ISE offers rapid, direct measurement with minimal sample prep.
Reaction Conditions

Chemical reaction conditions are not applicable. Instead, practical measurement conditions for chloride ISE use are summarized (literature/general guidance):

  • Temperature: Maintain a constant temperature during calibration and measurement (e.g., both at ambient lab temperature) to preserve a consistent Nernst slope. Recalibrate if temperature changes significantly.
  • Ionic strength: Use the provided ISA (if applicable) or a recommended ionic strength adjuster to hold activity coefficients constant across standards and samples.
  • Calibration scheme: Employ multi-point calibration spanning the expected sample range; bracketing improves accuracy. Stir gently to ensure homogeneity without introducing bubbles around the membrane.
  • Equilibration time: Allow the electrode to reach a stable potential at each point; response typically stabilizes within seconds to a few minutes depending on concentration and matrix.
  • Electrode care: Rinse between measurements with DI water, blot (do not wipe) to avoid static charge and membrane damage, and periodically verify slope (mV/decade) to detect fouling or aging.
  • Interferences: Minimize or complex interferents (e.g., silver, mercury, strong oxidants) and control pH to prevent formation of volatile HCl in strongly acidic matrices.
Safety and Handling

Safety information (GHS/CLP) is not provided in the product data for this specific item and will depend on the exact formulation and concentrations.

  • GHS classification, signal word, hazard statements, pictograms: Not specified for this item; refer to SDS.
  • General hazards (literature/general): Aqueous electrolyte solutions are typically low hazard at dilute concentrations; concentrated salts or buffers may be irritants. Some chloride ISE accessories can contain silver or nitrate; handle accordingly. Exact composition for this item: Not specified for this item; refer to SDS.
  • PPE: Wear lab coat, safety glasses, and suitable gloves. Avoid ingestion and contact with eyes/skin. Use in a clean analytical area to prevent contamination.
  • Handling: Avoid cross-contamination between standards. Use dedicated, clean polypropylene or glassware. Cap tightly to prevent evaporation, which alters concentration.
  • Incompatibilities (literature/general): Avoid contact with strong acids/bases unless specified, which can shift chloride speciation (e.g., formation of HCl gas under strongly acidic conditions). Keep away from reactive metals if any nitrate/silver components are present. Do not mix standards with oxidizing agents.
  • First aid (overview): If on skin/eyes, rinse with water for at least 15 minutes; if ingested or inhaled as aerosols/mists, move to fresh air and seek medical advice. Always defer to the SDS for the specific formulation.
  • Waste: Dispose of according to institutional and local regulations for aqueous salt solutions; silver-containing wastes require special collection (literature/general).
Solvent Selection

These are aqueous solutions intended for electroanalytical use; solvent selection in the synthetic sense is not typically applicable.

  • Medium: Water is the continuous phase (literature/general). Using high‑purity DI water for any dilutions is essential to avoid chloride contamination.
  • Miscibility: Fully miscible with water. Avoid mixing with organic solvents, which can change activity coefficients and electrode response (literature/general).
  • Practical notes:
    • Rinse electrodes and vessels with the working standard before measurements to condition surfaces.
    • If dilutions are required, use Class A glassware and freshly produced 18 MΩ·cm water to maintain accuracy.
  • When to choose alternatives: For non-aqueous chloride determinations, specialized ISEs and non-aqueous media are required; these aqueous solutions are not suitable (literature/general).
Storage and Reconstitution
  • Storage conditions: Room temperature (per product data). Protect from contamination and evaporation by keeping containers tightly closed. Avoid temperature extremes and direct sunlight.
  • Shipped in: Normal (per product data).
  • Reconstitution: Not applicable for ready-to-use solutions unless the product includes concentrates; if concentrates are supplied, dilute with high‑purity deionized water using Class A glassware (item-specific instructions: Not specified for this item; refer to CoA/Spec Sheet).
  • Handling: Record opening date and lot number. For highest accuracy, minimize headspace exposure and do not return used portions to the stock bottle.
  • Shelf life/stability: Not specified for this item; refer to CoA/Spec Sheet.
  • Research use note: For research use only (per product data). Ensure compatibility with your chloride ISE’s recommended filling solution and maintenance procedures.
Structure and Identity

This listing consists of ready-to-use aqueous solutions formulated for chloride ion-selective electrode (ISE) measurements (e.g., calibration standards, ionic strength adjuster, and/or filling solutions). These are mixtures rather than a single defined compound.

  • Chemical identity: Mixtures for electroanalytical use with a chloride ISE
  • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • SMILES: Not applicable to mixtures; Not specified for this item; refer to CoA/Spec Sheet.
  • InChIKey: Not applicable to mixtures; Not specified for this item; refer to CoA/Spec Sheet.
  • Likely constituents (literature/general): Aqueous chloride standards typically contain sodium chloride at known molarities or ppm levels; ionic strength adjusters (ISA) are commonly nitrate- or sulfate-based salts in water; filling solutions are typically salt solutions compatible with the electrode reference system. Exact composition for this catalog item is Not specified for this item; refer to CoA/Spec Sheet.
  • Structural features (descriptive): As aqueous electrolyte solutions, these contain solvated ions (e.g., Cl− and counter‑ions) in water; no discrete molecular structure applies.
Synthetic Utility

Not applicable. These are aqueous standards/adjusters/filling solutions designed for electroanalytical measurements and are not intended as reagents for chemical synthesis. For chloride sources in synthesis, consider reagent‑grade halide salts or chlorinating agents, chosen according to the reaction mechanism and compatibility.

Target Specificity

Not applicable. This product is not an antibody or biological affinity reagent. It is intended for potentiometric measurement of chloride ions using ion-selective electrodes.

Perguntas frequentes

How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
How should this product be stored?
Store at room temperature.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.