Human CD8⁺ T Cell Isolation Kit (Negative Isolation)

Cat. No.: H1522397
Disponível para encomenda
GRAU & PUREZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Tamanho
USA
Alemanha (EU)*
Preço
Qtd
10T
H1522397-10T
Sob encomenda · 8–12 semanas
209,90US$
50T
H1522397-50T
Sob encomenda · 8–12 semanas
929,90US$
100T
H1522397-100T
Sob encomenda · 8–12 semanas
1499,90US$
Enter a quantity for the sizes you want to add.
🧪
Por que este grau

BioReagent BioReagent para fluxos de trabalho cromatográficos e analíticos sensíveis que exigem interferência mínima da linha de base.

🌡

Armazenamento e envio

Store at 2-8°C,Do not freeze Envio Wet ice,Do not freeze. Consulte o COA específico do lote para obter as especificações exatas.

📋

Documentos de qualidade

SDS, COA, ficha técnica e folha de especificações disponíveis para download. COA específico do lote acessível por meio de pesquisa por número de lote.

📚

Comprovação documental

Citado em 0 publicações revisadas por pares nas áreas de cromatografia, síntese orgânica e reações de acoplamento cruzado.

Visão geral

The Human CD8⁺ T Cell Isolation Kit (Negative Isolation) is used to isolate CD8⁺ T cells from human peripheral blood mononuclear cells (PBMCs) by negative isolation. The principle is to use a cocktail of biotin-labeled monoclonal antibodies against non-target cells (non-CD8⁺ T cells), followed by removal of these non-target cells using streptavidin-labeled magnetic beads, thereby achieving the isolation of human peripheral blood CD8⁺ T cells. A magnetic separator is required for the isolation process.

Applications

Isolation of CD8⁺ T cells from freshly isolated or cryopreserved human PBMCs.

H1522397
Component
Appearance
10T
50T
100T
Storage
H1522397A
Biotin-Antibody Mix
Liquid20 μL
100 μL
200 μL
2-8℃.
H1522397B
Streptavidin Magnetic Beads
Liquid
200 μL
1 mL
1 mL×2
2-8℃.

Protocol Example

  1. Prepare human PBMCs

    Isolate PBMCs from human peripheral blood using Ficoll density gradient centrifugation. Collect the PBMCs, wash the cells with PBS, and after centrifugation, resuspend the PBMCs in Isolation Buffer to a density of 1×10⁸ cells/mL.

    Note: Isolation buffer is PBS containing 2 mM EDTA and 2% fetal bovine serum (FBS), or PBS containing 2 mM EDTA and 0.5% BSA. The buffer must be pre-filtered through a 0.22 μm filter.

  2. Add Biotin-Antibody Mix and wash

    Add 100 μL of cell suspension (1×10⁷ cells) to the bottom of a sterile 1.5 mL centrifuge tube, then add 2 μL of Biotin-Antibody Mix. Mix well and incubate at 4°C for 15 min. Add 10 volumes of Isolation Buffer, centrifuge at 500 g for 5 min, and discard the supernatant. Resuspend the cells in 100 μL of Isolation Buffer.

    Note: If isolating more cells, increase the volume of Biotin-Antibody Mix proportionally. A 15 mL or 50 mL centrifuge tube can be used. For example, to isolate 5×10⁷ cells, add 10 μL of Biotin-Antibody Mix to 500 μL of cell suspension, wash with 5 mL of Isolation Buffer, and after centrifugation, resuspend the cells in 500 μL of Isolation Buffer.

  3. Wash the magnetic beads

    Vortex thoroughly to resuspend the beads. Transfer 20 μL of beads to a sterile 1.5 mL centrifuge tube, add Isolation Buffer to a total volume of 1 mL, centrifuge at 10,000 g for 1 min (or use a magnetic separator for 3 min), and discard the supernatant. Add 1 mL of Isolation Buffer, wash the beads once more, and then resuspend the beads in 20 μL of Isolation Buffer.

  4. First addition of Streptavidin Magnetic Beads

    Add 10 μL of washed Streptavidin Magnetic Beads to the cell suspension, mix well, and incubate at 4°C for 10 min.

    Note: If isolating more cells, increase the volume of Streptavidin Magnetic Beads proportionally. For example, to isolate 5×10⁷ cells, add 50 μL of Streptavidin Magnetic Beads to 500 μL of cell suspension. If isolating fewer than 1×10⁷ cells, adjust the cell suspension volume to 100 μL and use 2 μL of Biotin-Antibody Mix and 10 μL of Streptavidin Magnetic Beads for the isolation.

  5. Transfer and dilute

    After incubation, transfer the cell and bead mixture to a sterile FACS tube, add Isolation Buffer to a total volume of 2.5 mL, and mix by pipetting 5 times.

  6. First magnetic separation

    Place the FACS tube containing the cell suspension on a magnetic separator and let stand for 5 min.

  7. Collect once-purified cells (optional second purification)

    Transfer the cell suspension to a sterile centrifuge tube (do not remove the FACS tube from the magnetic separator while transferring). This cell suspension contains the purified human CD8⁺ T cells and can be used for downstream biological experiments or flow cytometry analysis.

    To further increase the purity of CD8⁺ T cells, centrifuge the cell suspension at 500 g for 5 min, discard the supernatant, resuspend the cells in 100 μL of Isolation Buffer, and proceed with the second purification as described below.

    Note: If isolating more cells, increase the resuspension volume accordingly. For example, to isolate 5×10⁷ cells, after centrifugation, resuspend the cells in 500 μL of Isolation Buffer.

  8. Second addition of Streptavidin Magnetic Beads

    Add 10 μL of washed Streptavidin Magnetic Beads, mix well, and incubate at 4°C for 10 min.

    Note: If isolating more cells, increase the volume of Streptavidin Magnetic Beads proportionally. For example, to isolate 5×10⁷ cells, add 50 μL of Streptavidin Magnetic Beads to 500 μL of cell suspension.

  9. Second dilution and transfer

    After incubation, add Isolation Buffer to a total volume of 2.5 mL, mix by pipetting 5 times, and transfer the cell and bead mixture to a sterile FACS tube.

  10. Second magnetic separation

    Place the FACS tube containing the cell suspension on a magnetic separator and let stand for 5 min.

  11. Collect twice-purified cells

    Transfer the cell suspension to a sterile centrifuge tube (do not remove the FACS tube from the magnetic separator while transferring). This cell suspension contains the twice-purified human CD8⁺ T cells. The second purification can increase the purity of CD8⁺ T cells by 2-4%.

  12. Resuspend for further use

    Wash the cells as required for your experiment, then resuspend them in the desired buffer or culture medium for subsequent molecular or cell biology experiments.

Isolation Performance

CD8⁺ T cells were isolated from human PBMCs. Cells before and after isolation were stained with PE-labeled anti-human CD8a antibody (clone RPA-T8) and APC-labeled anti-human CD3 antibody (clone OKT3) and analyzed by flow cytometry. The purity of CD3⁺CD8⁺ T cells before and after isolation was 15.3% and 91.5%, respectively.

Precautions

  1. Avoid freezing the magnetic beads and antibody mix during use and storage.

  2. Low-retention pipette tips and centrifuge tubes are recommended to avoid loss of beads and antibodies due to adsorption.

  3. This product must be used with a magnetic separator.

  4. For research use only.

Especificações

Especificações e pureza
BioReagent
Grau
BioReagent
Aplicação
Cell analysis
Armazenamento e envio
Condições de armazenamento de armazenamento
Store at 2-8°C,Do not freeze
Enviado em
Wet ice,Do not freeze
Estabilidade e armazenamento
Store at 2-8℃ long term (12 months). Do not freeze.
Contents & Storage
H1522397
Component
Appearance
10T
50T
100T
Storage
H1522397A
Biotin-Antibody Mix
Liquid20 μL
100 μL
200 μL
2-8℃.
H1522397B
Streptavidin Magnetic Beads
Liquid
200 μL
1 mL
1 mL×2
2-8℃.

Documentação

📋 Ficha de dados de segurança (FDS)

Documento abrangente sobre perigos, manuseamento, armazenamento e conformidade regulamentar.

<<<<<<< HEAD Baixar SDS → ======= Baixar SDS → >>>>>>> release248-p3

✅ Certificado de análise (COA)

Dados de qualidade específicos do lote. Introduza o número de lote para obter o COA exato.

Consultar COA →

📊 Ficha técnica

Resumo de referência rápida das especificações e aplicações do produto.

Ver ficha técnica →

🔬 Folha de especificações

Atributos de qualidade completos e critérios de aceitação para este grau.

Ver folha de especificações →

Dados avançados

Certificados(CoA,COO,BSE/TSE e Mapa de Análise)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDataItem
ZJ26F0636754ZJ26F0636754Certificate of AnalysisJun 25, 2026 H1522397
FAQs e artigos
Calculadoras de soluções
Revisões

Avaliações dos Clientes

Precisa de ajuda para escolher o grau?

O nosso guia de seleção de graus abrange pureza, estado do estabilizador e adequação à aplicação para todas as variantes do nosso catálogo.

Ver o guia de graus BioReagent →

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.