Recombinant CD11b Antibody (AF700): Selection & Usage Guide
Recombinant CD11b Antibody (AF700): Selection & Usage Guide
Recombinant CD11b Antibody (AF700) is an Alexa Fluor 700-conjugated recombinant antibody targeting CD11b (Integrin alpha M), designed for reliable identification and characterization of myeloid cell populations by flow cytometry.
- SKU
- Ab213135
- Conjugate
- Alexa Fluor 700 (AF700)
- Antibody Format
- Recombinant antibody
- Target Antigen
- CD11b (Integrin alpha M, ITGAM)
- Primary Application
- Flow cytometry (FC)
- Parental Clone Reference
- Based on Ab210604Z Recombinant CD11b Antibody
CD11b as a Research Target: Background and Significance
CD11b, also known as Integrin alpha M (ITGAM) or Mac-1 alpha chain, is a type I transmembrane glycoprotein that associates non-covalently with CD18 (Integrin beta 2) to form the heterodimeric complement receptor 3 (CR3, Mac-1). This receptor plays essential roles in leukocyte adhesion, migration, phagocytosis, and complement-mediated immune responses.
CD11b is broadly expressed on myeloid lineage cells including monocytes, macrophages, neutrophils, dendritic cells, and natural killer (NK) cells. Its expression pattern makes it one of the most widely used markers for myeloid cell identification in immunological research, tumor microenvironment studies, inflammation models, and hematopoiesis assays.
Accurate detection of CD11b expression levels is critical for distinguishing myeloid cell subsets, assessing activation states, and characterizing immune infiltrates in tissues. High-quality, well-validated antibodies are therefore essential tools in these workflows.
Product Overview: Recombinant CD11b Antibody (AF700)
Recombinant CD11b Antibody (AF700) (Ab213135) is a recombinant antibody directly conjugated to the Alexa Fluor 700 (AF700) fluorochrome, enabling sensitive and specific detection of CD11b-positive cell populations by flow cytometry without the need for a secondary antibody step.
The recombinant format of this antibody offers key advantages over conventional hybridoma-derived antibodies, including superior lot-to-lot consistency, reduced risk of batch variation, and enhanced reproducibility across experiments. The parental unconjugated antibody is referenced as Ab210604Z Recombinant CD11b Antibody, ensuring traceability of the binding domain.
AF700 is an Alexa Fluor dye with excitation maximum near 702 nm and emission maximum near 723 nm, making it compatible with red laser (633 nm or 640 nm) excitation on standard multi-laser flow cytometers. AF700 exhibits excellent photostability and brightness, and its spectral properties allow it to be combined with a broad panel of other fluorochromes in multicolor flow cytometry panels.
Recommended Protocol for Flow Cytometry
The following protocol provides general guidance for using Recombinant CD11b Antibody (AF700) in surface staining flow cytometry experiments. Always consult the specific product datasheet for lot-specific recommended concentrations and storage conditions.
- Sample preparation: Prepare single-cell suspensions from peripheral blood, bone marrow, spleen, or other tissues of interest. Recommended cell density is 1–5 × 10⁶ cells per staining reaction. For blood samples, lyse red blood cells using an appropriate lysis buffer prior to staining.
- Fc receptor blocking: Incubate cells with an appropriate Fc receptor blocking reagent for 10–15 minutes at 4 °C to minimize non-specific antibody binding, particularly for myeloid cells which express high levels of Fc receptors.
- Surface staining: Add the titrated amount of Ab213135 to the cell suspension. Mix gently and incubate for 20–30 minutes at 4 °C protected from light. Optimal antibody concentration should be determined by titration for each specific application and cell type.
- Washing: Wash cells twice with PBS containing 1–2% BSA or FBS. Centrifuge at 300–400 × g for 5 minutes at 4 °C.
- Viability staining: Include a viability dye compatible with AF700 spectral properties to exclude dead cells from analysis. Select a viability dye with minimal spectral overlap with AF700 (emission ~723 nm).
- Data acquisition: Acquire data on a flow cytometer equipped with a 633 nm or 640 nm red laser. Set appropriate compensation controls using single-stain controls for each fluorochrome in the panel.
- Analysis: Gate on live, single cells. Identify CD11b-positive populations based on comparison with isotype control or fluorescence minus one (FMO) control.
Important: Always include an isotype control or FMO control to accurately define CD11b-positive and CD11b-negative populations and to account for background fluorescence.
Panel Design and Multicolor Considerations
Integrating Recombinant CD11b Antibody (AF700) into a multicolor flow cytometry panel requires careful consideration of spectral overlap, laser configurations, and panel balance. The following guidance supports optimal panel design.
Laser compatibility: AF700 is optimally excited by the red laser (633 nm or 640 nm). Ensure your instrument is equipped with this laser line before incorporating AF700 into your panel.
Spectral overlap: AF700 (emission ~723 nm) may exhibit spectral overlap with APC (emission ~660 nm) and APC-Cy7 (emission ~785 nm) when using a red laser. Proper compensation is essential. Use single-stain compensation controls prepared under identical conditions to experimental samples (same cell type or compensation beads validated for the antibody format).
Antigen abundance matching: CD11b is typically highly expressed on granulocytes and monocytes, making AF700, a moderately bright fluorochrome, well-suited for this target. Reserve the brightest fluorochromes (e.g., PE, BV421) for low-expression markers in your panel.
Recommended controls: Include FMO controls for AF700, appropriate isotype controls, single-stain compensation controls, and a viability dye. Use unstained cells as a negative baseline reference.
Fixation compatibility: If intracellular staining is required in combination with CD11b surface staining, verify that fixation and permeabilization reagents are compatible with both AF700 fluorochrome stability and antigen integrity before proceeding.
Storage, Handling, and Quality Assurance
Proper storage and handling of Recombinant CD11b Antibody (AF700) are critical to maintaining antibody performance and fluorochrome integrity over time.
Storage: Store the antibody at 4 °C, protected from light. Alexa Fluor dyes are photosensitive and prolonged exposure to light will result in fluorochrome degradation and reduced signal intensity. Do not freeze AF700-conjugated antibodies unless specified by the manufacturer, as freeze-thaw cycles can cause aggregation and loss of activity. Always consult the product-specific datasheet for confirmed storage conditions.
Handling: Keep the vial on ice during use. Aliquot into single-use volumes if repeated freeze-thaw cycles cannot be avoided (only if freezing is confirmed as acceptable by the datasheet). Use low-binding tubes to minimize antibody loss through adsorption.
Quality indicators: Visually inspect the antibody solution before use. Discard if precipitation, turbidity, or unusual color change is observed. Performance verification by running a positive control cell line or tissue known to express CD11b is recommended when using a new lot.
Recombinant antibody advantages: As a recombinant antibody, Ab213135 provides enhanced batch-to-batch reproducibility compared to conventional monoclonal antibodies, supporting consistent experimental outcomes across different lots and over time.
Expiry: Refer to the expiry date on the vial label. Do not use the product beyond its expiration date.
Frequently asked questions
What laser and detector configuration is required to detect AF700 on a flow cytometer?
AF700 is best excited by a red laser at 633 nm or 640 nm. Detection is typically performed using a bandpass filter centered around 720–730 nm. Confirm your instrument configuration is compatible before designing your panel, as AF700 is not efficiently excited by blue (488 nm) or violet (405 nm) lasers.
Why should I choose a recombinant antibody format for CD11b detection?
Recombinant antibodies such as Recombinant CD11b Antibody (AF700) (Ab213135) are produced from defined genetic sequences rather than hybridoma cell lines, resulting in superior lot-to-lot consistency and reduced risk of batch-dependent variability. This is particularly valuable in longitudinal studies or when reproducing published experimental data.
How do I determine the optimal working concentration of Ab213135 for my experiment?
Optimal antibody concentration must be determined empirically by titration for each specific cell type and application. Prepare a serial dilution of Ab213135 and stain a known CD11b-positive cell population (e.g., human or mouse monocytes). Select the concentration that gives the highest staining index (separation between positive and negative populations) with minimal background. Always refer to the product datasheet for the manufacturer's starting recommendation.
Can AF700-conjugated antibodies be used after fixation?
Alexa Fluor 700 dyes are generally compatible with common fixatives such as paraformaldehyde when used at standard concentrations and fixation times. However, prolonged fixation or use of certain fixatives may reduce fluorescence intensity. It is recommended to validate fixation conditions empirically and to refer to the product datasheet for specific compatibility information before combining surface CD11b staining with intracellular staining workflows.
References
- Binnerts ME, et al. CD11b/CD18 (Mac-1, CR3) as an adhesion and signaling molecule in the immune system. General reference for CD11b biology.
- Krutzik PO, Nolan GP. Fluorescent cell barcoding in flow cytometry allows high-throughput drug screening and signaling profiling. Nature Methods, 2006. General reference for multicolor flow cytometry panel design principles.
- Alexa Fluor dye technical documentation. Thermo Fisher Scientific. General reference for AF700 spectral properties.
Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.
