GRAU & PUREZAMoligand™?Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools.
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Revisões
Avaliações dos Clientes
Application Protocols
No vendor-validated application protocols are provided for this item. The following is general, assay-agnostic guidance for handling small-molecule test articles.
Example workflow (general)
Stock preparation
Weigh appropriate amount quickly to minimize moisture exposure.
Prepare a 10–50 mM stock in anhydrous DMSO. Vortex and, if needed, sonicate briefly. Record exact concentration.
Serial dilution
Create a half-log or 3-fold dilution series in DMSO or assay buffer with matched vehicle, targeting ≤0.5% DMSO final.
Include vehicle-only and, if available, assay-positive controls.
Assay addition
Add compound to assay plates last to minimize edge and evaporation effects. Mix gently but thoroughly.
Quality controls
Inspect for precipitation/turbidity after incubation.
Run interference controls (fluorescence, redox, detergent sensitivity) if assay modality is susceptible.
Data integrity
Normalize to vehicle controls; repeat key points in independent runs and, when possible, with a second lot.
All parameters above are general guidance only and must be adapted to your specific assay format and institutional SOPs.
Biological Roles
Item-specific biological functions, targets, and pathways for MI-30 are not disclosed in this listing.
General guidance for research use of small-molecule tools
Hypothesis testing: Use MI-30 as a putative chemical modulator only within controlled research experiments; confirm any observed phenotype with orthogonal chemotypes or genetic controls (e.g., RNAi/CRISPR) to avoid mechanism misassignment.
Assay triangulation: Combine biochemical potency data with biophysical (e.g., DSF, ITC, SPR) and cellular target-engagement readouts to build a coherent MoA narrative.
Selectivity assessment: Profile across related protein families (kinases, GPCRs, epigenetic enzymes, etc., as applicable to your research question) to detect off-target interactions.
ADME flags (general): Early solubility, permeability (PAMPA/MDCK), and microsomal stability screens help interpret cellular outcomes; no ADME data are provided for this item.
Explicit disclaimer
No biological role, target, or pathway is specified for MI-30 in the Product Data. All experimental conclusions must be derived empirically within the user’s laboratory. For research use only.
Buffer Applications
MI-30 is a research small molecule and not a buffering reagent. There are no intrinsic buffer applications to describe for this item.
Practical guidance (assay compatibility)
Vehicle control: Match the final DMSO (or other solvent) concentration in all wells/tubes, including negative controls.
Precipitation checks: After diluting MI-30 into assay buffer/media, visually inspect for haze/precipitate; if present, adjust solvent percentage within assay limits or add a small amount of nonionic surfactant (only if compatible with the assay).
Typical assay buffers: Use target-appropriate systems (e.g., HEPES, Tris, PBS) with pH and ionic strength validated for target stability; avoid phosphate in some metal-dependent enzymes if chelation/precipitation is a concern.
Item-specific buffer capacity, pKa, or salt effects: Not specified for this item; refer to CoA/Spec Sheet if later provided.
Green Alternatives
Greener handling for small-molecule screening centers on solvent selection, waste minimization, and plate-based processes.
Stock preparation: Prefer DMSO over chlorinated solvents for master stocks when chemically compatible. If volatility is essential (e.g., plate coating), consider ethanol or acetonitrile instead of dichloromethane (DCM), subject to compound stability.
Extraction/workup (analytical): Replace DCM with ethyl acetate or MTBE; for polar analytes, ACN protein precipitation can reduce chlorinated waste.
Cleaning: Use aqueous detergents and ethanol/IPA where feasible instead of acetone/THF.
Comparison (general; item-agnostic)
DCM vs EtOAc
Environmental profile: EtOAc greener, biodegradable; DCM is chlorinated and regulated.
Performance: EtOAc suitable for many nonpolar to mid-polar solutes; test recovery for this specific compound.
DMF vs MeTHF/EtOAc (for synthesis contexts)
If any synthetic manipulation is performed, greener ethers (2-MeTHF, CPME) or esters (EtOAc) may substitute polar aprotics; confirm solubility and stability.
Operational strategies
Miniaturize assays (384/1536-well formats) to reduce solvent use.
Consolidate waste streams (halogenated vs non-halogenated) to optimize disposal.
Note: Compound-specific stability and solubility constraints are unknown for MI-30; validate any solvent switch with small-scale tests.
Pharmaceutical Uses
This product is supplied strictly for laboratory research use and is not intended for human or veterinary applications, drug substance manufacture, or clinical diagnostics.
Formulation-related research context (general)
Preformulation screening: If MI-30 is pursued as a research lead, characterize solubility across pH, co-solvent, and surfactant systems to guide in vitro dosing solutions.
Vehicles for in vivo research (general note): Not applicable for this listing; Aladdin does not provide guidance for animal dosing. If your institution permits, follow internal IACUC/safety policies and generate de novo stability/tox profiles.
Excipient status: No pharmacopeial excipient status is indicated.
Item-specific pharmacopeial, GMP, or residual solvent compliance: Not specified for this item; refer to CoA/Spec Sheet.
Clear disclaimer
No therapeutic claims are made or implied. Use only in controlled research experiments by qualified personnel.
Physical Properties
Item-specific physicochemical constants are not disclosed in this listing. Use the guidance below to plan handling and solubilization.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Melting point (literature/computed): Not specified for this item; refer to CoA/Spec Sheet.
Boiling point (literature/computed): Not specified for this item; refer to CoA/Spec Sheet.
Density: Not specified for this item; refer to CoA/Spec Sheet.
LogP/logD, pKa, refractive index: Not specified for this item; refer to CoA/Spec Sheet.
Aqueous solubility: Not specified for this item; refer to CoA/Spec Sheet.
Practical guidance (general)
Initial dissolution: Prepare concentrated DMSO stocks (commonly 10–50 mM) for small-molecule screening items when structural solubility predictors are unavailable.
Co-solvent strategy: If precipitation occurs upon dilution into aqueous buffers, introduce a co-solvent step (e.g., pre-dilute DMSO stock 1:10 into media containing 1–5% DMSO final) while vortexing and sonicating briefly.
Filtration: For turbid working solutions, pass through 0.22–0.45 µm PTFE filters (chemical compatibility superior to PES/nylon for many hydrophobic compounds).
Adsorption: Minimize non-specific binding by using low-bind polypropylene plates/tubes; glass can adsorb certain basic or aromatic chemotypes.
Light/moisture sensitivity: Not specified; as a precaution, protect from strong light and moisture during solution handling until item-specific data are reviewed.
Quality and Grades
Grade/Purity: Moligand™
What Moligand grade generally implies (context)
Research screening suitability: Moligand-branded items are intended for research workflows such as biochemical/cell-based screening, target validation, and SAR exploration. They are not manufactured or released for clinical or diagnostic use.
Documentation: Purity, identity, and residual solvent profiles, when available, are provided on a batch CoA/Spec Sheet. For this SKU, specific numeric purity or spectral criteria are not listed here.
Item-specific notes
Purity specification: Not specified for this item; refer to CoA/Spec Sheet.
Stabilizers/inhibitors: Not specified for this item; refer to CoA/Spec Sheet.
Salt/solvate form: Not specified for this item; refer to CoA/Spec Sheet.
Best practices
Fit-for-purpose verification: Prior to critical assays (e.g., IC50 determination), verify identity by an orthogonal method (e.g., LC–MS) and confirm purity meets your internal acceptance criteria.
Low-UV work: If using in UV-based detection, assess background absorbance of solvent blanks and the analyte to ensure compatibility with your detection wavelength.
Replicability: Record batch/lot numbers in ELNs to correlate experimental outcomes with material provenance.
Reaction and Applications
This SKU is sold as a research small molecule in the Moligand collection and is not positioned as a synthetic reagent. Accordingly, no item-specific reactions are provided. The following outlines common research applications for such compounds.
Typical research uses
Biochemical screening: Enzyme or binding assays to gauge potency and preliminary SAR. Employ serial dilutions (e.g., 10-point half-log) from DMSO stocks.
Cell-based assays: Phenotypic or target-engagement readouts; confirm solvent tolerance and adsorption to plastics.
Orthogonal/confirmatory assays: Thermal shift (DSF), SPR/BLI, or CETSA to corroborate binding or stabilization effects (assay design dependent on target class; no target is specified here).
Profiling: Broad selectivity or cytotoxicity panels to detect off-target liabilities early.
Practical tips
Plate preparation: Use low-bind plates, freshly prepare dilutions, and avoid >1 freeze–thaw of stock.
Aggregation artifacts: Include a small amount of nonionic detergent if appropriate, and run counter-screens to identify promiscuous aggregation (no structure provided, so treat as unknown risk).
Interference controls: Check for fluorescence, redox, or luciferase interference using standard assay interference panels where relevant.
Note: No manufacturer-provided application notes are available for this item; adapt these general practices to your assay system.
Reaction Conditions
Not applicable. MI-30 is not sold as a reagent for chemical synthesis, and no item-specific reaction conditions are provided.
Method development guidance (solution handling and analytics)
Solution stability checks: Assess stability of MI-30 in your chosen solvent by LC–MS after 0, 4, and 24 h at bench conditions. Include a light-protected aliquot to evaluate photolability.
Adsorption mitigation: For low-concentration work (<1 µM), use siliconized or low-bind plasticware; pre-rinse vials with a small volume of working solution.
Assay plate conditions: Validate performance across typical laboratory temperatures (e.g., 20–25°C) and avoid extended incubations at elevated temperatures without stability data.
Expected yields/timings: Not applicable.
All numeric reaction parameters, catalysts, and yields: Not specified for this item.
Safety and Handling
Authoritative safety information must be obtained from the product’s SDS. The following are general laboratory precautions for small-molecule screening compounds.
GHS/Classification: Not specified for this item; refer to SDS.
Signal word / Hazard statements / Pictograms: Not specified for this item; refer to SDS.
General precautions
PPE: Wear lab coat, safety glasses, and suitable chemical-resistant gloves (e.g., nitrile). Handle powders/solutions in a fume hood to avoid inhalation exposure.
DMSO considerations: If preparing DMSO stocks, note DMSO can enhance dermal absorption of solutes; avoid skin contact.
Incompatibilities: Unknown for this item; segregate from strong oxidizers/acids/bases until incompatibility data are confirmed in the SDS.
Spill response: Absorb small liquid spills with inert material (vermiculite), collect solid spills by gentle sweeping to minimize dust, and dispose of as chemical waste.
First aid (overview): If inhaled—fresh air; skin—wash with soap/water; eyes—rinse with water for several minutes; ingestion—rinse mouth. Seek medical attention; bring SDS.
Waste: Dispose in accordance with institutional and local regulations for organic research chemicals.
Storage conditions
Per product data: Store at room temperature.
Additional handling: Keep container tightly closed, use desiccation if hygroscopicity is suspected, and minimize freeze–thaw cycles of solutions by aliquoting.
Solvent Selection
Because structure-specific solubility data are not disclosed, begin with a conservative, broadly compatible solubilization strategy for small-molecule screening compounds.
Primary options
DMSO: Default solvent for 10–50 mM master stocks due to broad solvency and compatibility with biochemical and cellular assays at ≤0.5–1.0% v/v final.
DMF/Acetonitrile: Useful for difficult solutes; verify assay tolerance (typically ≤0.3–1% v/v ACN/DMF in many enzyme or binding assays).
Ethanol/Isopropanol: Alternative for some hydrophobic compounds; watch for assay- or cell-compatibility limits.
Aqueous dilution tips
Pre-wet approach: Dilute DMSO stock first into an intermediate solution containing the final buffer and 0.05–0.5% nonionic surfactant (e.g., Tween 20) if precipitation is observed (confirm assay tolerance).
pH leverage: If the compound is ionizable (unknown here), modest pH adjustments within assay-acceptable bounds can improve solubility.
Quick reference table (general)
Typical final solvent tolerance in assays (guideline; verify locally):
DMSO: 0.1–1.0% v/v
ACN: 0.05–0.5% v/v
EtOH: 0.1–1.0% v/v
When to choose alternatives
For LC–MS bioanalytical work, ACN/H2O or MeOH/H2O with 0.1% formic acid is often preferred for sample prep; reconstitute first in DMSO if needed, then back-dilute into the LC mobile phase.
For solid-phase storage or coating, volatile solvents (ACN, MeOH) aid rapid drying on plates; confirm compound stability versus evaporation conditions.
Storage and Reconstitution
Storage (as supplied): Room temperature (per Product Data). Keep tightly closed in a dry, well-ventilated place. Use a desiccant if ambient humidity is high.
Shipping: Not specified for this item; refer to CoA/Spec Sheet.
Appearance at receipt: Not specified for this item; refer to CoA/Spec Sheet.
Reconstitution (general guidance for small molecules)
Solvent choice: Start with anhydrous DMSO for concentrated stocks (e.g., 10–50 mM). If DMSO is unsuitable for your assay, consider ACN, DMF, ethanol, or isopropanol after small-scale compatibility checks.
Technique: Warm to room temperature before opening to avoid condensation. Add solvent incrementally while vortexing; brief sonication can assist dissolution. If insoluble, trial a co-solvent approach.
Sterilization: For cell-based assays, sterile-filter final working solutions through 0.22 µm PTFE filters if compatible.
Aliquoting and stability
Aliquot to single-use vials/plates to avoid repeated freeze–thaw or prolonged air exposure.
Light and moisture: Not specified for this item; as a precaution, protect from strong light and humidity during handling of solutions.
Solution stability: Not specified for this item; verify by LC–MS/LC–UV over intended use windows.
Item-specific stabilizers, hydrate/solvate form, and exact shelf-life: Not specified for this item; refer to CoA/Spec Sheet.
Structure and Identity
Brief overview: MI-30 (SKU M611862) is listed in our Moligand small-molecule collection for research and screening workflows. Item-specific structural details are not disclosed in this listing.
SKU: M611862
Product Name: MI-30
Catalog Category: Small molecules and compound libraries (Moligand collection)
CAS: M611862 (internal catalog identifier)
PubChem CID: 155817519 (as provided)
InChIKey: 123837 (as provided)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
Structural features
Item-specific functional groups, ring systems, heteroatoms, and stereochemistry: Not specified for this item; refer to CoA/Spec Sheet.
2D structure description: Not available in this listing. If you require an annotated 2D depiction and atom numbering for analytical work, request the latest CoA/structure file for this SKU.
Notes
Identity confirmation, when supplied, typically relies on spectral data (e.g., LC–MS and/or NMR) included in the CoA. For this listing, consult the current batch documentation to verify exact structure and any salt/solvate state before use in assays or registration systems.
Synthetic Utility
MI-30 is offered as a research test article rather than a chemical building block or reagent. Without disclosed structure or functional groups, synthetic reactivity or transformation pathways cannot be described.
General considerations if derivatization is contemplated
Structural confirmation: Obtain a structural file (SDF/mol) and verify functional groups by NMR/LC–MS before planning analog synthesis.
Protecting-group strategy: Select conditions compatible with any sensitive motifs (unknown here); start with mild methods and small-scale trials.
Reference standard use: If MI-30 serves as an analytical reference, prepare stable isotopic/internal standards separately and validate chromatographic resolution from potential impurities.
Item-specific reactive handles, named-reaction suitability, or retrosynthetic disconnections: Not specified for this item; refer to CoA/Spec Sheet/structural dossier if available.
Target Specificity
Target name/class: Not specified for this item; no target annotation is provided in the Product Data.
Species selectivity, binding epitope, or mechanism: Not specified for this item.
Guidance for users
If MI-30 is investigated as a putative modulator, confirm target engagement with at least two orthogonal methods and include negative/positive controls where available.
For panel profiling, ensure consistent vehicle and plate layout to avoid positional artifacts.
All target-related claims must be established empirically by the end user. For research use only.
Perguntas frequentes
How should this product be stored?
Store at room temperature.
What is Moligand??
Moligand? is one of Aladdin Scientific's premium product lines, formulated for high-purity applications across multiple workflows. Compared to standard grades in the same workflow, Moligand? products typically offer tighter specifications, more rigorous QC, and stronger lot-to-lot consistency.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is M611862. InChIKey HKJKOHDJUKCNRG-ZEAPZOAHSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Precisa de ajuda para escolher o grau?
O nosso guia de seleção de graus abrange pureza, estado do estabilizador e adequação à aplicação para todas as variantes do nosso catálogo.
Usamos cookies para garantir o funcionamento adequado do site e, quando permitido, para melhorar a sua experiência. Você pode gerenciar suas preferências a qualquer momento nas Configurações. Saiba mais em nossa Política de Cookies.
Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?
Lembrar-me mais tarde
Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.