Particle Size Certified Reference Materials - Particle Size:115.1nm

Cat. No.: P119506
Disponível para encomenda
GRAU & PUREZA Particle Size:115.1nm
Storage
Room temperature
Shipped In
Normal
★
Tamanho
USA
Alemanha (EU)*
Preço
Qtd
9ml
P119506-9ml
Sob encomenda · 8–12 semanas
238,90US$
Enter a quantity for the sizes you want to add.

Especificações

Especificações e pureza
Particle Size:115.1nm
Condições de armazenamento de armazenamento
Room temperature
Enviado em
Normal

Dados avançados

Certificados(CoA,COO,BSE/TSE e Mapa de Análise)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDataItem
F1512090F1512090Certificate of AnalysisOct 16, 2024 P119506
Calculadoras de soluções
Revisões

Avaliações dos Clientes

Application Protocols

Item-specific, tested applications and dilutions: Not specified for this item; refer to CoA/Spec Sheet.

General protocols (literature/general; adapt to certificate instructions)

  • DLS calibration check
    • Equilibrate the CRM to measurement temperature (e.g., 25°C). Gently invert; avoid bubbles.
    • Prepare a dilution in 0.1–0.2 µm filtered DI water to reach the manufacturer’s recommended count rate/attenuation. Mix by gentle inversion.
    • Rinse a clean, dust-free cuvette three times with the dilution. Fill and cap. Allow 5–10 min to equilibrate. Measure ≥3 runs; assess z-average and PDI against certified values.
  • Laser diffraction verification
    • Select optical model using the CRM’s refractive index. Circulate dispersant to achieve baseline. Add drops of CRM until obscuration target is reached.
    • Acquire triplicate measurements at specified pump/stir speeds. Compare D10/D50/D90 or volume mean to certified size.
  • NTA size/count check
    • Dilute to reach recommended particle/frame. Record multiple videos at consistent camera settings. Analyze and compare mean/modal size to certificate.

Good practice

  • Record lot number, expiry, dilution recipe, temperature, and instrument settings with each run.
  • Use fresh aliquots; avoid returning used material to the stock to prevent contamination.
Biological Roles

Not typically applicable to this product.

  • Particle size CRMs are metrological standards rather than biomolecules. They do not possess inherent biological roles or metabolic functions.
  • If used in bioanalytical method qualification (e.g., sizing extracellular vesicles), their role is as a physical size standard, not as a biological reagent.
Buffer Applications

Limited applicability.

  • These materials are not buffering agents. However, dispersion and dilution are often performed in simple media (e.g., filtered deionized water) or specified low-ionic-strength buffers to maintain colloidal stability.
  • For this item, recommended diluents, ionic strength, and pH windows are not specified; refer to CoA/Spec Sheet.

General tips (literature/general)

  • Use freshly filtered (0.1–0.2 µm) water to minimize dust that can skew light-scattering results.
  • Avoid high-salt buffers unless the CRM certificate endorses them; electrolyte screening can induce aggregation or alter hydrodynamic size.
  • Match dispersant viscosity and temperature to the conditions under which certification was performed for best agreement.
Green Alternatives

Context

  • Green chemistry considerations are not central for particle size CRMs, but selection of medium and handling can reduce environmental impact.

General guidance (literature/general)

  • Prefer aqueous dispersions when possible to avoid volatile organic compounds (VOCs) used in some nonaqueous standards.
  • Minimize waste by preparing only the volumes needed for a session and by using closed cuvettes to extend working life of dilutions.
  • Reuse policy: Do not return used dilutions to stock to avoid contamination; instead, plan small-volume dilutions to reduce disposal.
  • Disposal: Follow institutional and local regulations. Many latex/silica dispersions can be coagulated/flocculated and filtered for solid waste disposal; avoid drain disposal unless permitted.

Comparison (general)

  • Aqueous medium: Low toxicity, minimal VOCs, simple waste streams; may require biocides which introduce additional EHS considerations.
  • Alcohol-based medium (IPA/EtOH): Faster drying and better wetting for imaging but flammable and VOC-emitting; manage with closed containers and fume hoods.

Item-specific note

  • The exact medium and preservatives for this item are not specified; consult the CoA/Spec Sheet and SDS for environmentally relevant constituents before planning waste management.
Pharmaceutical Uses

Formulation/Manufacturing context (no clinical claims)

  • Particle size CRMs may be used in pharmaceutical quality control laboratories to qualify and calibrate sizing instruments used for raw materials, suspensions, inhalation powders, and injectable dispersions.
  • They can support method validation parameters (accuracy, precision, range) for compendial or in-house procedures assessing particle size distributions.

Item-specific note

  • Pharmacopeial status, compliance, or specific suitability claims for this item are not specified; refer to CoA/Spec Sheet and regulatory guidelines.

Good practices (literature/general)

  • Maintain traceability: Record CRM lot numbers in validation protocols and OOS investigations.
  • Evaluate matrix effects: Demonstrate that measurements in product-relevant media are equivalent to CRM measurements or account for differences.
  • Establish requalification intervals for instruments using CRMs bracketing the routine measurement range.
Physical Properties

Item-specific facts (from Product Data)

  • Physical state/appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Density, refractive index, zeta potential, dispersant, solids content: Not specified for this item; refer to CoA/Spec Sheet.

Literature/general values (context only; not item-specific)

  • Polystyrene latex microspheres: density ~1.05 g/cm³; refractive index ~1.59 @ 589 nm (literature).
  • Amorphous silica microspheres: density ~2.0–2.2 g/cm³; refractive index ~1.45 @ 589 nm (literature).
  • Typical certified size ranges available commercially span nanometers to tens/hundreds of micrometers (e.g., ~20 nm to ~100 µm), with CV often <5% for monodisperse lots (literature).
  • Dispersibility: Often water or alcohols for latex; silica may require aqueous buffers with pH control to minimize aggregation (literature).

Notes for users

  • Optical particle-sizing requires approximate refractive index of both particles and medium; use supplier-provided n and k values when modeling Mie scattering. For this item, consult CoA/Spec Sheet for optical constants.
  • Temperature and ionic strength can affect hydrodynamic size in DLS; verify measurement temperature and viscosity of the dispersant.
Quality and Grades

Item-specific details (from Product Data)

  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.

What “Certified Reference Material (CRM)” typically entails (literature/general)

  • Metrological framework: CRMs are characterized by a technically valid procedure, certified for one or more specified properties (e.g., particle size), with an associated uncertainty and statement of metrological traceability.
  • Accreditation: High-quality particle size CRMs are often produced under ISO 17034 (reference material producers) and with measurements under ISO/IEC 17025 (testing/calibration labs). Accreditation status for this item is not specified; refer to documentation.
  • Certificate contents: Certified mean/modal size, expanded uncertainty (k-factor), homogeneity and stability assessment, measurement methods (e.g., TEM/SEM, AFM, SEM image analysis, DLS, laser diffraction), traceability route, and instructions for use.
  • Fit-for-purpose: Select a CRM close to your operational size range and optical model. For laser diffraction, match refractive index; for DLS, match hydrodynamic regime and polydispersity.
  • Stabilizers/Preservatives: Some aqueous standards include surfactants/biocides to prevent aggregation or microbial growth. Presence/identity for this item is not specified; refer to CoA/Spec Sheet.

Practical notes

  • Use unopened aliquots for QC trending to minimize use uncertainty.
  • Record environmental conditions (temperature, viscosity, ionic strength) when measuring to maintain comparability with the certified state.
Reaction and Applications

Applicability to this product

  • These materials are standards, not reagents for chemical synthesis; no “reactions” apply. Instead, applications focus on instrument qualification, calibration, and method validation.

Key applications (literature/general)

  • Dynamic Light Scattering (DLS): Verify size accuracy, repeatability, and resolution across submicron ranges; assess instrument alignment and cuvette cleanliness.
  • Laser Diffraction (LD): Validate size distributions from ~0.1–1000 µm; test alignment, obscuration settings, and optical model robustness.
  • Nanoparticle Tracking Analysis (NTA): Check sizing and concentration linearity; verify camera focus and thresholding.
  • Electron/Optical Microscopy: Calibrate pixel size/magnification; evaluate image analysis algorithms with monodisperse spheres.
  • Coulter/Resistive Pulse Sensing: Validate aperture selection and coincidence corrections.
  • Method transfer and QC trending: Use the same CRM lot to benchmark inter-instrument variability and operator effects.

Practical tips

  • Homogenization: Gently invert or roll; brief low-power sonication if permitted in the CoA. Avoid frothing.
  • Cleanliness: Use low-particulate labware; rinse cuvettes/flow cells with filtered medium.
  • Concentration: Work within the certificate’s recommended attenuator/obscuration or count rate targets to avoid multiple scattering or coincidence.
  • Documentation: Record lot number, expiry, storage history, and dilution recipe to maintain traceability.
Reaction Conditions

Not applicable to chemical reactions.

General usage conditions for sizing (literature/general)

  • Temperature control: DLS and NTA results are temperature-dependent via viscosity; stabilize at 20–25°C or as specified in the certificate.
  • Concentration: Aim for instrument-recommended count rates/obscuration (e.g., single scattering regime for DLS; low coincidence for Coulter-type methods). Exact targets vary by instrument.
  • Sonication: If allowed, brief, low-power sonication helps break weak agglomerates; avoid over-sonication that can alter particle integrity.
  • Filtration: Use syringe filters (0.2–0.45 µm) only if the certified size is much smaller than the pore size and if permitted by the certificate; filtration can bias distributions.

Item-specific parameters such as certified size, acceptable media, and use instructions are not specified for this item; refer to CoA/Spec Sheet.

Safety and Handling

Item-specific hazards (from Product Data)

  • GHS signal word, hazard statements, classification, pictograms: Not specified for this item; refer to SDS.
  • Storage conditions: Room temperature (per Product Data).
  • Shipped: Normal conditions.

General safety guidance (literature/general)

  • Handle CRMs as laboratory chemicals. Avoid generating dust/aerosols. For powders, use local exhaust; for dispersions, prevent inhalation of mists.
  • PPE: Safety glasses, lab coat, disposable nitrile gloves. Use splash protection when preparing dilutions or sonication.
  • Incompatibilities: Dispersions can be destabilized by high ionic strength, surfactant mismatch, extreme pH, and organic solvent blends not recommended by the supplier. Avoid cationic surfactants with negatively charged latex unless specified.
  • First aid (overview; defer to SDS): Eye contact—rinse cautiously with water for several minutes. Skin—wash with soap and water. Inhalation—move to fresh air. Ingestion—rinse mouth; seek medical advice if symptoms persist.
  • Spill response: For powders, avoid dry sweeping; dampen and collect. For liquids, contain and absorb on inert material; prevent release to drains until assessed.
  • Special risks: Ultrasonic bath/probe can aerosolize or heat dispersions; use covers and control power settings. When drying droplets for microscopy, avoid hot plates that can char organics; use low heat.
  • Always consult the product’s SDS and CoA/Spec Sheet for definitive hazard and handling instructions.
Solvent Selection

Applicability to this product

  • Solvent selection is not typically the primary consideration for particle size CRMs; they are often supplied as ready-to-use aqueous dispersions or as dry powders intended for dispersion in specified media. For this item, the supplied medium and any recommended diluents are not specified; refer to CoA/Spec Sheet.

General guidance (literature/general)

  • Aqueous dispersions: Use deionized, filtered water (0.1–0.2 µm) with low ionic strength to minimize DLVO-driven aggregation. Adjust pH within the stability window stated in the CoA.
  • Organic-compatible standards: Some CRMs are validated in alcohols (e.g., ethanol/IPA) or specific nonaqueous media for LD or imaging; match refractive index models accordingly.
  • Additives: Only add surfactants (e.g., 0.01–0.05% nonionic) if recommended by the certificate; unintended additives can alter hydrodynamic size and zeta potential.

Comparison (general)

  • Water: Highest instrument compatibility for DLS/NTA; low toxicity; sensitive to CO2 absorption and ionic contaminants.
  • IPA/Ethanol: Faster drying for microscopy grids; lower surface tension aids wetting; flammable and can change particle–particle interactions.
  • Buffered saline: Improves biological relevance but increases screening; may induce aggregation unless the CRM is rated for it.
Storage and Reconstitution

Item-specific storage and shipping (from Product Data)

  • Storage conditions: Room temperature.
  • Shipped in: Normal conditions.

Item-specific details not provided

  • Appearance, dispersant, solids content, preservative/biocide, shelf life/expiry, and reconstitution instructions: Not specified for this item; refer to CoA/Spec Sheet.

General guidance (literature/general)

  • Storage
    • Keep containers tightly closed to limit evaporation/contamination. Store upright and protect from freezing if the medium is aqueous (unless the certificate permits freezing).
    • Avoid prolonged exposure to light/UV that may degrade polymeric matrices or preservatives.
    • Do not store working dilutions for extended periods unless validated; microbial growth and evaporation change concentration and size distribution.
  • Reconstitution/Preparation
    • For dry powders, if applicable: Allow to equilibrate to room temperature before opening to minimize moisture condensation. Disperse in specified medium, using gentle stirring and, if permitted, brief sonication.
    • For dispersions: Gently invert/roll to homogenize. Do not vortex aggressively to avoid foaming and air entrapment.
  • Traceability
    • Record opening date and maintain lot-specific logs. Use within the validity period indicated on the CoA when available.
Structure and Identity

Item-specific facts (from Product Data)

  • Product type: Particle Size Certified Reference Materials (CRMs)
  • CAS, CID, InChIKey, SMILES, Molecular formula, Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.

General description (literature/general)

  • These materials are typically monodisperse particulate standards used to verify and calibrate particle-sizing instruments (e.g., laser diffraction, DLS, NTA, image analysis, electron microscopy).
  • Common matrices: polymeric latex (e.g., polystyrene), silica, or metal-oxide spheres; may be supplied as aqueous dispersions or dry powders. Specific composition for this item is not specified.
  • Structural features: Spherical morphology (most common for size standards), narrow size distribution with a certified mean diameter and uncertainty; some products include multimodal blends for resolution checks.
  • Identity attributes usually provided in a CRM’s documentation: certified modal/mean particle size, distribution width, uncertainty budget, measurement method(s), and metrological traceability. For this item, consult CoA/Spec Sheet for exact identity attributes.
Synthetic Utility

Not applicable.

  • Particle size CRMs are standards rather than synthetic building blocks or reagents. They are not typically used to perform chemical transformations.
  • For research involving nanoparticle synthesis, CRMs may serve as independent controls to verify sizing methods, but they are not reactants or catalysts.
Target Specificity

Not applicable.

  • This product is not an antibody, probe, or affinity reagent and does not have biological target specificity.