Sputum Digestion Solution (Trypsin Digestion Method) - BioReagent, Sterile

Cat. No.: S1533119
Disponível para encomenda
GRAU & PUREZA BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization.
Synonyms
Trypsin‑based Sputum Digestion Solution
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
Application
1102
★
Tamanho
USA
Alemanha (EU)*
Preço
Qtd
100ml
S1533119-100ml
Sob encomenda · 8–12 semanas
39,90US$
Enter a quantity for the sizes you want to add.
🧪
Por que este grau

BioReagent, Sterile BioReagent,Estéril para fluxos de trabalho cromatográficos e analíticos sensíveis que exigem interferência mínima da linha de base.

🌡

Armazenamento e envio

Store at -20°C Envio Ice chest + Ice pads. Consulte o COA específico do lote para obter as especificações exatas.

📋

Documentos de qualidade

SDS, COA, ficha técnica e folha de especificações disponíveis para download. COA específico do lote acessível por meio de pesquisa por número de lote.

📚

Comprovação documental

Citado em 0 publicações revisadas por pares nas áreas de cromatografia, síntese orgânica e reações de acoplamento cruzado.

Visão geral

Specimens such as sputum, body fluids and feces are commonly used in microbiological assays, featuring complex matrices and a wide spectrum of microorganisms. Mycobacterium tuberculosis has high nutritional demands and slow growth rates. Contaminating microbes in specimens grow rapidly during culture, consuming nutrients and impairing the detection of Mycobacterium tuberculosis.

Specimens containing contaminants (e.g., sputum, gastrointestinal specimens, bronchoalveolar lavage fluid, transbronchial aspirates) require pre-treatment before culture for specimen liquefaction and decontamination. Urine, autopsy tissues and other contaminated liquid specimens also need decontamination prior to culture. Specimens collected from sterile body sites without contamination, including blood, cerebrospinal fluid and synovial fluid, may be directly centrifuged, and the sediment is used for inoculation.

Common digestion reagents for specimen pre-treatment include sulfuric acid, sodium hydroxide, N‑acetyl-L-cysteine (NALC), benzalkonium bromide, oxalic acid, trypsin and dithiothreitol (DTT). This Sputum Digestion Solution (Trypsin Digestion Method) is mainly composed of trypsin and phosphate salts, with a pH of approximately 7.6. It is sterile-processed and widely applied for homogenization of sputum specimens. For research use only. Not for clinical diagnosis or other applications.

Required Materials:

1. Sputum, body fluid, feces and other specimens

2. Normal saline, PBS, culture medium

3. Inoculating loop, centrifuge tubes, centrifuge, scissors, mortar

Operating Procedures (For Reference Only):

(I) Sputum Specimens

1. Transfer approximately 5 mL of thick sputum into a labeled 50 mL centrifuge tube.

2. Add an equal volume of sputum digestion solution for homogenization. Vortex for 20 seconds, then incubate at 30–37 °C for 15–20 minutes.

3. Add sterile PBS (pH ~6.8) up to 50 mL, centrifuge at 3000 r/min for 15 minutes.

4. Discard the supernatant, then resuspend the pellet in 1–3 mL of PBS.

(II) Body Fluid Specimens

1. For sterile body fluids: take 10 mL fluid into a centrifuge tube for centrifugation, and inoculate the sediment directly.

2. For contaminated body fluids: process following the protocol for sputum specimens.

(III) Tissue Specimens

1. Take 1 g tissue, cut into small pieces with scissors, add 5 mL culture medium, homogenize using a mortar, then transfer the homogenate into a 50 mL centrifuge tube.

2. Follow the subsequent steps of the sputum specimen protocol.

(IV) Fecal Specimens

1. Add 1 g feces into a 50 mL centrifuge tube, mix thoroughly with 5 mL culture medium.

2. Follow the subsequent steps of the sputum specimen protocol.

Precautions:

1. Sputum samples are preferably collected in the early morning. The subject should rinse the mouth thoroughly with cool boiled water before sampling to avoid contamination by normal oral flora.

2. For urine samples, the midstream portion of the first morning urine is recommended.

3. Samples should be delivered to the laboratory immediately after collection.

4. If the sample is used for the detection of Mycobacterium tuberculosis, an adequate volume of sputum is required.

5. Patients with pulmonary infection may be complicated with bacteremia; blood culture should be performed simultaneously.

6. Use the reagent promptly after opening the package to avoid compromised experimental results.

Especificações

Sinónimos
Trypsin‑based Sputum Digestion Solution
Especificações e pureza
BioReagent, Sterile
Estabilidade e armazenamento
Store at -20℃ long term (12 months).
Condições de armazenamento de armazenamento
Store at -20°C
Enviado em
Ice chest + Ice pads
Este produto requer transporte de cadeia fria. Serviços terrestres e outros serviços econômicos não estão disponíveis.
Grau
BioReagent, Estéril
Product Line
Produtos biológicos

Documentação

📋 Ficha de dados de segurança (FDS)

Documento abrangente sobre perigos, manuseamento, armazenamento e conformidade regulamentar.

<<<<<<< HEAD Baixar SDS → ======= Baixar SDS → >>>>>>> release248-p3

✅ Certificado de análise (COA)

Dados de qualidade específicos do lote. Introduza o número de lote para obter o COA exato.

Consultar COA →

📊 Ficha técnica

Resumo de referência rápida das especificações e aplicações do produto.

Ver ficha técnica →

🔬 Folha de especificações

Atributos de qualidade completos e critérios de aceitação para este grau.

Ver folha de especificações →

Dados avançados

Certificados(CoA,COO,BSE/TSE e Mapa de Análise)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Calculadoras de soluções
Revisões

Avaliações dos Clientes

Precisa de ajuda para escolher o grau?

O nosso guia de seleção de graus abrange pureza, estado do estabilizador e adequação à aplicação para todas as variantes do nosso catálogo.

Ver o guia de graus BioReagent → Ver o guia de graus Sterile →

Deseja que lhe enviemos uma mensagem quando tivermos descontos disponíveis?

Lembrar-me mais tarde

Obrigado! Por favor, verifique a sua caixa de entrada de e-mail para confirmar.

Ops! As notificações estão desativadas.