AZ82 is a selective kinesin-like protein KIFC1 (HSET/KIFC1) inhibitor, with a K i of 43 nM and an IC 50 of 300 nM for KIFC1.
In Vitro
AZ82 is shown to specifically induce multipolar spindles in BT-549 cells, but not in cancer cells with normal centrosome number, such as HeLa. AZ82 binds specifically to KIFC1/MT complex but not to KIFC1 or MT alone. Treatment with AZ82 caused centrosome declustering in BT-549 breast cancer cells with amplified centrosomes. AZ82 inhibits both processes with an IC 50 of 0.90 ± 0.09 μM for mant-ATP binding and 1.26 ± 0.51 μM for mant-ADP releasing. MCE has not independently confirmed the accuracy of these methods. They are for reference only.
This compound belongs to the class of organic compounds known as n-acyl-alpha amino acids and derivatives. These are compounds containing an alpha amino acid (or a derivative thereof) which bears an acyl group at its terminal nitrogen atom.
External Descriptors
Not available
1. Djoumbou Feunang Y, Eisner R, Knox C, Chepelev L, Hastings J, Owen G, Fahy E, Steinbeck C, Subramanian S, Bolton E, Greiner R, and Wishart DS. ClassyFire: Automated Chemical Classification With A Comprehensive, Computable Taxonomy. Journal of Cheminformatics, 2016, 8:61.
Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Propiedades químicas y físicas
Solubilidad
DMSO : 125 mg/mL (222.96 mM; Need ultrasonic)
Peso molecular
560.6
XLogP3
5.800
Hydrogen Bond Donor Count
3
Hydrogen Bond Acceptor Count
9
Rotatable Bond Count
10
Exact Mass
560.207 Da
Monoisotopic Mass
560.207 Da
Topological Polar Surface Area
121.000 Ų
Heavy Atom Count
39
Formal Charge
0
Complexity
819.000
Isotope Atom Count
0
Defined Atom Stereocenter Count
2
Undefined Atom Stereocenter Count
0
Defined Bond Stereocenter Count
0
Undefined Bond Stereocenter Count
0
The total count of all stereochemical bonds
0
Covalently-Bonded Unit Count
1
Calculadoras de soluciones
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Reseñas
Reseñas de cliente
Application Protocols
No validated, item-specific protocols are provided for AZ82. The following generic workflow is commonly applied to small-molecule library members in biochemical or cell-based assays. Adapt to your system and consult the SDS.
Stock preparation:
Weigh under dry conditions. Prepare a 10–50 mM stock in anhydrous DMSO. Vortex and, if needed, sonicate briefly. Record exact concentration.
Aliquoting and storage:
Dispense single-use aliquots (e.g., 10–50 μL) in low-bind tubes or plates. Seal tightly, purge with inert gas if feasible, and store at −20 °C (see Storage & Reconstitution).
Working solution:
Dilute the DMSO stock into assay buffer or media to the desired concentration, keeping final DMSO at or below assay tolerance (commonly ≤0.1–0.5% v/v). Mix thoroughly to prevent local supersaturation.
Controls:
Include vehicle controls matched for solvent and positive/negative controls relevant to the assay modality. Consider detergent controls (0.01–0.05% nonionic) to identify aggregation artifacts.
Data quality checks:
Inspect for precipitation/turbidity. Optionally filter (0.22 μm) or centrifuge before readout. Verify stability over the assay window by LC–MS where critical.
These steps are general templates and not validated for this specific item.
Biological Roles
Item-specific biological roles, targets, or pathways for AZ82 are not specified in the product data. No mechanism-of-action or endogenous role can be asserted without structural/target information.
General notes for small-molecule tools (not item-specific):
Small molecules in discovery libraries are often assessed for their ability to modulate enzymes, receptors, ion channels, transporters, or protein–protein interactions.
Putative biological roles are established empirically through dose–response experiments, structure–activity relationship (SAR) follow-up, and orthogonal validation assays.
Off-target profiling and selectivity panels (e.g., kinases, GPCRs, CYPs) help contextualize observed phenotypes and minimize misannotation.
Caveats:
Do not ascribe biological function or therapeutic relevance to this item without supporting data. All uses are for research only, and any biological inferences must be validated experimentally.
Buffer Applications
AZ82 is not a buffering agent, and no buffer-system role is specified for this item. However, as a small-molecule library compound, it may be dosed into buffered media for assays. The following general points apply:
Vehicle control:
Match final DMSO/organic co-solvent concentration in control wells/tubes to that used with compound (commonly 0.1–0.5% v/v) to isolate compound effects from solvent effects.
Buffer compatibility checks:
Verify compound solubility upon dilution into common assay buffers (e.g., PBS, HBSS, HEPES-buffered media). Inspect for precipitation or turbidity immediately and after incubation at assay temperature.
Surfactants:
For aggregation-prone molecules, include a small amount of nonionic detergent (e.g., 0.01–0.05% Tween-20 or Pluronic F-127) if compatible with the assay to mitigate colloidal aggregation artifacts.
Adsorption:
Hydrophobic compounds may adsorb to plastic; precondition plates/tubes with buffer containing 0.1% serum albumin or use low-bind plastics to improve delivery fidelity.
Green Alternatives
No specific process chemistry is associated with this library compound in the provided data. For routine solution preparation and analytics, consider greener choices where feasible:
Solvent selection hierarchy (general):
Prefer water where possible for dilutions and quenching.
Use ethanol or isopropanol as greener organic solvents when compatible, before resorting to acetonitrile, DMF, or halogenated solvents.
DMSO has favorable safety/green metrics relative to DMF/NMP in many lab contexts and is widely accepted in screening workflows.
Practical substitutions (examples):
Replace DMF with ethanol or isopropanol for preliminary solubility checks if compound allows.
Use miniaturized assay formats (384/1536-well) to reduce solvent waste.
Implement sealed plates for DMSO stocks to limit evaporation and reduce replenishment volume.
Waste and EHS:
Segregate halogenated from non-halogenated waste. Rinse vials with small volumes of greener solvent before disposal where allowed.
Trade-offs:
Greener solvents may reduce solubility for hydrophobic compounds; balance environmental benefits with data quality. Validate that alternative solvents do not alter assay readouts (include vehicle controls).
Pharmaceutical Uses
No pharmacopeial status, dosage-form role, or excipient application is specified for AZ82. This product is supplied strictly for research use only and is not intended for human or veterinary applications.
General, non-clinical context (not item-specific):
In preclinical discovery, small molecules from libraries may be evaluated for developability attributes (e.g., solubility, chemical stability) and preliminary formulation compatibility for in vitro or exploratory in vivo research. Such work is distinct from clinical/formulation use and must follow institutional approvals.
If formulation screening is pursued, typical vehicles tested include aqueous buffers with minimal cosolvent, DMSO/PEG400 mixtures, or lipid-based systems—selected strictly based on research objectives and safety governance.
No therapeutic claims are made or implied for this item.
Physical Properties
Item-specific properties (specifications):
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Melting point (MP): Not specified for this item; refer to CoA/Spec Sheet.
Boiling point (BP): Not specified for this item; refer to CoA/Spec Sheet.
Density, refractive index, UV cutoff, water/peroxide/metal limits: Not specified for this item; refer to CoA/Spec Sheet.
Solubility: Not specified for this item; refer to CoA/Spec Sheet.
Literature/general guidance (not item-specific):
Small molecules used as screening tools commonly dissolve well in DMSO; some are soluble in DMF, ethanol, or acetonitrile. Aqueous solubility can vary widely and may require co-solvent or pH adjustment if ionizable.
If a UV–Vis chromophore is present (unknown here), typical analytical wavelengths fall in 210–300 nm for monitoring by HPLC.
Practical tips (general):
Determine solubility empirically: start at 10 mM in anhydrous DMSO, sonicate/gently warm if needed; avoid prolonged high heat.
For buffer compatibility, prepare a small test dilution (e.g., 1:1000 DMSO into buffer) and inspect for precipitation; filter through 0.22 μm if required.
Document any observed MP/appearance upon receipt to aid future QC trending.
Quality and Grades
Item-specific grade/purity: Not specified for this item; refer to CoA/Spec Sheet.
What to expect on the CoA (general guidance):
Assay/purity method (e.g., HPLC/UPLC area %, LC–MS purity), with solvent system and detection wavelength.
Identity confirmation (e.g., MS m/z, NMR key peaks, or full spectral data).
Residual solvents, water (Karl Fischer), and if applicable, counterion content for salts.
Implications for use:
For biochemical and cell-based assays, high chemical purity and a clean impurity profile reduce off-target and assay-interference risks.
If UV analytics are planned, low-UV background solvents and disclosure of chromophore are useful; in absence of data, verify by running a quick scan (200–400 nm).
Recommended incoming QC (general):
Visual inspection, MP (if solid), LC–MS purity check, and 1H NMR if structure is available.
Verify lot-to-lot consistency where critical experiments depend on compound performance.
Stabilizers/additives:
None are specified for this item. If any stabilizer or salt form is present, it will be listed on the CoA/label; adjust calculations accordingly.
Reaction and Applications
Manufacturer Applications: No item-specific application notes were provided. AZ82 is listed within a small-molecule/compound library category. The guidance below covers typical research applications of such compounds.
Biochemical target screening (general):
Use in enzyme inhibition/activation, receptor binding, or transporter assays. Begin with a broad concentration range (e.g., 0.03–30 μM) to establish preliminary potency curves while avoiding compound aggregation artifacts (include 0.01–0.1% nonionic detergent if appropriate).
Cell-based assays:
Assess functional responses (reporter gene, viability, signaling readouts). Confirm lack of overt cytotoxicity at working concentrations using orthogonal viability dyes.
Counter-screens and orthogonal validation:
Rule out pan-assay interference (PAINS) and redox/metal-chelating liabilities using appropriate counterscreens. Confirm activity in label-free or alternative detection formats to avoid fluorescence/absorbance interference.
Analytical support:
LC–MS to track stability in assay media, microsomal stability (if ADME characterization is relevant), and solubility/turbidity checks across concentration.
Notes:
Without a disclosed structure or known functional group set, no specific synthetic or named-reaction applications can be recommended for this item. Its primary value is as a potential tool/lead in discovery biology once target activity is established experimentally.
Reaction Conditions
Not applicable to this item in the absence of structural information and without a stated role as a reagent or catalyst.
General guidance if derivatization is later intended (not item-specific):
Establish identity and purity by LC–MS/NMR first.
Run small-scale scouting reactions with conservative conditions and orthogonal analytics to monitor integrity.
Protect potentially labile functionalities (unknown here) from strong acid/base, high heat, or prolonged light exposure until compatibility is established.
Safety and Handling
Item-specific hazard data:
Signal Word: Not specified for this item; refer to SDS.
H-Statements: Not specified for this item; refer to SDS.
GHS Classification/Pictograms: Not specified for this item; refer to SDS.
General laboratory safety (defer to SDS as authoritative):
Handle in a fume hood and avoid inhalation, ingestion, and skin/eye contact. Wear appropriate PPE: lab coat, safety glasses, and suitable gloves (e.g., nitrile). If dust or aerosols are possible, use respiratory protection per institutional policy.
First aid (general): rinse eyes/skin with water for ≥15 minutes if exposure occurs; remove contaminated clothing. Seek medical attention as needed. If inhaled, move to fresh air; if ingested, rinse mouth and consult medical services.
Storage incompatibilities (general): keep away from strong oxidizers/acids/bases unless compatibility is known. Protect from moisture and light until specific stability data are available.
Spill/cleanup: contain, avoid dust, absorb with inert material, and dispose per local regulations. Prevent release to drains.
Fire-fighting: use CO2, dry chemical, or foam; combustion may produce COx/NOx/halides depending on structure (unknown here). Firefighters should wear self-contained breathing apparatus.
Research use only: Not for diagnostic, clinical, or human/animal consumption. Always consult the product SDS and institutional EHS guidance before use.
Solvent Selection
Item-specific solubility data are not provided. The following is general, target-agnostic guidance suitable for small molecules in screening workflows:
Primary stock solvent:
DMSO (anhydrous) is typically the first choice for 10–50 mM stocks due to broad solvency and assay compatibility at ≤0.5% v/v in most biological assays.
Alternative solvents (if DMSO is unsuitable):
DMF (good solvency; consider cytotoxicity, hygroscopicity), ethanol (greener, volatile), acetonitrile (miscible with water, volatile), or isopropanol (less volatile, often acceptable in biochem assays at ≤1%).
Aqueous working solutions:
Prepare by serial dilution of the organic stock into buffer with vigorous mixing to avoid local supersaturation; keep final organic co-solvent ≤0.1–1% v/v depending on biological tolerance.
pH/ionization:
If the compound is ionizable (unknown here), solubility may improve with pH adjustment. Perform small-scale pH scans (e.g., pH 5–9) to locate maximal solubility compatible with assay biology.
Practical tips:
Warm (≤37 °C) and brief sonication can aid dissolution. Filter 0.22 μm before sensitive measurements. Record clear vs. turbid outcomes at intended assay concentrations.
Selection rationale:
Choose the least toxic, most volatile solvent compatible with the assay to simplify removal and minimize background effects. Validate solvent effects with matching vehicle controls.
Storage and Reconstitution
Item-specific conditions (from Product Data):
Storage: Store at −20 °C
Shipping: Ice chest + ice pads
General guidance for small-molecule solids or DMSO solutions (not item-specific):
Upon receipt: Allow the sealed container to equilibrate to room temperature before opening to prevent moisture condensation. If supplied as a solution, keep cold and protected from light; return to −20 °C promptly after aliquoting.
Reconstitution:
If solid: Prepare a concentrated stock (e.g., 10–50 mM) in anhydrous DMSO. Vortex/sonicate briefly to dissolve. Avoid heating above 37 °C. Document concentration and solvent.
If solution: Verify concentration on the label/CoA. Mix gently before aliquoting.
Aliquoting:
Create single-use aliquots to minimize freeze–thaw. Use low-bind tubes/plates. If feasible, blanket headspace with inert gas and seal tightly to reduce oxidative/hydrolytic degradation.
Handling and stability:
Protect from light and moisture unless stability data indicate otherwise. Avoid repeated freeze–thaw; thaw on ice or at room temperature, use immediately, and refreeze remaining aliquots promptly.
Shelf life:
Specific retest/expiration information is not specified for this item; refer to CoA/Spec Sheet. For internal tracking, assign conservative review dates (e.g., 12 months for solids, 3–6 months for DMSO stocks) pending vendor data.
Always defer to the product’s CoA/SDS for definitive storage and stability instructions.
Structure and Identity
Brief overview: AZ82 is listed as a small-molecule library member. Structural descriptors for this specific item are not provided in the product data, so identity confirmation must rely on the CoA/SDS for this SKU.
Item-specific facts (from Product Data):
Product Name: AZ82 (SKU: A648582)
CAS: 1449578-65-7
PubChem CID: 91885438
InChIKey: 281614 (as provided; appears truncated vs. typical 27-character InChIKey; verify on CoA/Spec Sheet)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Chemical Name: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
Structural features:
Item-specific 2D/3D structural information is not provided. No assertions on rings, functional groups, or stereochemistry can be made without the structural string or a depiction.
Best practice for identity confirmation (general guidance):
Cross-check CAS and CID against authoritative databases (PubChem/Regulatory registries).
Verify full InChIKey/SMILES and molecular formula on the item’s CoA.
Authenticate received material by orthogonal methods (e.g., LC–MS for exact mass and purity profile; 1H/13C NMR if structure is available; HRMS for formula).
Synthetic Utility
Item-specific structural information for AZ82 is not provided; therefore, no reliable guidance can be given on its reactivity, functional group compatibility, or use as a synthetic reagent/building block.
General considerations (not item-specific):
If structure becomes available and the compound bears derivatizable handles (e.g., aryl halide, carboxylic acid, amine), standard transformations may be considered for probe derivatization (e.g., amide coupling, Suzuki–Miyaura, Buchwald–Hartwig, click chemistry for tag installation).
For bioconjugation or photoaffinity probe design, confirm presence/absence of sensitive motifs before introducing linkers or photoreactive groups.
Until detailed structure and purity specifications are confirmed on the CoA, treat this material as a final test article rather than a synthetic intermediate.
Target Specificity
Item-specific target information is not provided for AZ82. No claims are made regarding selectivity, potency, or off-target profiles.
General note:
If used as a putative tool compound, establish target specificity through parallel profiling (e.g., counterscreens, selectivity panels, CRISPR knock-out/knock-down rescue experiments) and confirm structure–activity relationships with close analogs.
Utilizamos cookies para garantizar el correcto funcionamiento del sitio web y, cuando esté permitido, para mejorar su experiencia. Puede gestionar sus preferencias en cualquier momento en Configuración. Más información en nuestra Política de Cookies.
¿Quieres que te enviemos un mensaje cuando tengamos descuentos disponibles?
Recordármelo más tarde
¡Gracias! Por favor, revisa tu bandeja de entrada de correo electrónico para confirmar.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.